Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electro-optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Parallel Processing Systems for Passive Ranging During Helicopter Flight

The complexity of rotorcraft missions involving operations close to the ground result in high pilot workload. In order to allow a pilot time to perform mission-oriented tasks, sensor-aiding and automation of some of the guidance and control functions are highly desirable. Images from an electro-optical sensor provide a covert way of detecting objects in the flight path of a low-flying helicopter. Passive ranging consists of processing a sequence of images using techniques based on optical low computation and recursive estimation. The passive ranging algorithm has to extract obstacle information from imagery at rates varying from five to thirty or more frames per second depending on the helicopter speed. We have implemented and tested the passive ranging algorithm off-line using helicopter-collected images. However, the real-time data and computation requirements of the algorithm are beyond the capability of any off-the-shelf microprocessor or digital signal processor. This paper describes the computational requirements of the algorithm and uses parallel processing technology to meet these requirements. Various issues in the selection of a parallel processing architecture are discussed and four different computer architectures are evaluated regarding their suitability to process the algorithm in real-time. Based on this evaluation, we conclude that real-time passive ranging is a realistic goal and can be achieved with a short time.

Sridhar, Bavavar↗

Numerical Simulations of Self-Focused Pulses Using the Nonlinear Maxwell Equations

This paper will present results in computational nonlinear optics. An algorithm will be described that solves the full vector nonlinear Maxwell's equations exactly without the approximations that are currently made. Present methods solve a reduced scalar wave equation, namely the nonlinear Schrodinger equation, and neglect the optical carrier. Also, results will be shown of calculations of 2-D electromagnetic nonlinear waves computed by directly integrating in time the nonlinear vector Maxwell's equations. The results will include simulations of 'light bullet' like pulses. Here diffraction and dispersion will be counteracted by nonlinear effects. The time integration efficiently implements linear and nonlinear convolutions for the electric polarization, and can take into account such quantum effects as Kerr and Raman interactions. The present approach is robust and should permit modeling 2-D and 3-D optical soliton propagation, scattering, and switching directly from the full-vector Maxwell's equations. Abstract of a proposed paper for presentation at the meeting NONLINEAR OPTICS: Materials, Fundamentals, and Applications, Hyatt Regency Waikaloa, Waikaloa, Hawaii, July 24-29, 1994, Cosponsored by IEEE/Lasers and Electro-Optics Society and Optical Society of America

Goorjian, Peter M.↗

Solid State Laser

The Titan-CW Ti:sapphire (titanium-doped sapphire) tunable laser is an innovation in solid-state laser technology jointly developed by the Research and Solid State Laser Divisions of Schwartz Electro-optics, Inc. (SEO). SEO is producing the laser for the commercial market, an outgrowth of a program sponsored by Langley Research Center to develop Ti:sapphire technology for space use. SEO's Titan-CW series of Ti:sapphire tunable lasers have applicability in analytical equipment designed for qualitative analysis of carbohydrates and proteins, structural analysis of water, starch/sugar analyses, and measurements of salt in meat. Further applications are expected in semiconductor manufacture, in medicine for diagnosis and therapy, and in biochemistry.

Source record↗

Vision Test in Seconds

Acuity Systems, Inc. developed an electro-optical instrument under a grant from NASA to measure the visual performance of pilots. Transferred from Ames Research Center, this instrument now allows you to have your eyes tested in seconds by relatively unskilled operators. The device automatically measures refractive error of eye and prints out proper prescription for glasses. The unit also detects cataracts and glaucoma.

Source record↗

Lead Poison Detection

With NASA contracts, Whittaker Corporations Space Science division has developed an electro-optical instrument to mass screen for lead poisoning. Device is portable and detects protoporphyrin in whole blood. Free corpuscular porphyrins occur as an early effect of lead ingestion. Also detects lead in urine used to confirm blood tests. Test is inexpensive and can be applied by relatively unskilled personnel. Similar Whittaker fluorometry device called "drug screen" can measure morphine and quinine in urine much faster and cheaper than other methods.

Source record↗

Aerospace Measurements: Challenges and Opportunities

New aerospace research initiatives offer both challenges and opportunities to rapidly-emerging electronics and electro-optics technology. Defining and implementing appropriate measurement technology development programs in response to the aeronautical ground facility research and testing needs of the new initiatives poses some particularly important problems. This paper discusses today's measurement challenges along with some of the technological opportunities which offer some hope for meeting the challenges, and describes measurement technology activities currently underway in the Langley Research Center's Instrument Research Division to address modern aerospace research and design engineering requirements. Projected and realized benefits and payoffs from the ongoing measurement and instrumentation efforts will be emphasized. A discussion of future trends in the aerospace measurement technology field will be included.

Conway, Bruce A.↗

Microbe Detector

The AutoMicrobic System (AMS) represents years of intensive research and development by McDonnell Douglas Corp. that originated with a NASA study aimed at development of a fully automated microbial detection and identification system for spacecraft use. A urine specimen is placed into the system, where it is subjected to different freeze-dried microbe nutrients for the nine most common pathogens. An electro-optical scanner studies each specimen once an hour through a 4-to-13 hour cycle, operating automatically. Changes in cell growths on each culture are monitored by computer. The presence of pathogens is indicated when growth reaches a predetermined level. The system also enumerates the pathogens and specifies the type. Developed initially to handle urine testing, AMS soon is expected to allow analyses of blood, spinal fluid, and other body fluids. An additional capability under development is "susceptibility testing," or the determination of which microbe-killing agents-such as penicillin or other antibiotics-would be most effective in eliminating the pathogens. The whole process of detecting, identifying, and enumerating the pathogens and determining susceptibility is accomplished in less half the time required for the manual procedure. The AMS minimizes human error, reduces technician time , and increases laboratory output.

Source record↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Kuppermann, Aron↗

Frequency doubled, cavity dumped feedback laser

Higher efficiency in cavity dumping and frequency doubling in a laser used to produce modulated output beam pulses is achieved by deflecting light out of the resonant cavity to a third mirror through a frequency doubler using an electro-optic modulator and a polarizing beamsplitter in the resonant cavity, or using just an acousto-optic modulator to deflect light out of the laser cavity in response to a control signal (electric or acoustic). The frequency doubler in front of the third mirror rotates the frequency doubled light so that it will pass out of the laser cavity through the polarizing beamsplitter, while undoubled frequency light is reflected by the polarizing beamsplitter back into the gain medium of the laser. In the case of using a type-II frequency doubler, a dichroic beamsplitter deflects out the frequency doubled light and passes the undoubled frequency light to the polarizing beamsplitter for return to the laser gain medium. If an acousto-optic modulator is used, it deflects light out of the primary laser cavity, so a polarizing beamsplitter is not needed, and only a dichroic beamsplitter is needed to separate frequency doubled light out of the path from the third mirror.

Sipes, Jr., Donald L.↗

Method of making a semiconductor device assembly

The invention is a semiconductor device assembly and method of making the same. A mounting plate has positioning means for positioning the plate relative to a header, a first mounting surface of the plate is attached to the header and a semiconductor device is attached to a second mounting surface of the mounting plate. The assembly is made by forming the mounting plate, positioning the mounting plate relative to the header by the positioning means, attaching the first mounting surface to the header and the semiconductor device to the second mounting surface. Another method of making the assembly is by defining and etching a mounting plate and attaching the first mounting surface to the header and the semiconductor device to the second mounting surface. This assembly and process provides an efficient means for mounting semiconductor devices and in particular electro-optic devices such as lasers.

Dholakia, Anil R.↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Boettger, Heinz G.↗

Semiconductor device assembly and method of making same

The invention is a semiconductor device assembly and method of making the same. A mounting plate has positioning means for positioning the plate relative to a header, a first mounting surface of the plate is attached to the header and a semiconductor device is attached to a second mounting surface of the mounting plate. The assembly is made by forming the mounting plate, positioning the mounting plate relative to the header by the positioning means, attaching the first mounting surface to the header and the semiconductor device to the second mounting surface. Another method of making the assembly is by defining and etching a mounting plate and attaching the first mounting surface to the header and the semiconductor device to the second mounting surface. This assembly and process provides an efficient means for mounting semiconductor devices and in particular electro-optic devices such as lasers.

Dholakia, Anil R.↗

A Method of Monitoring Non-Resonant Raman Lidar Returns During Daylight Hours

A method for using non-resonant Raman lidar during daytime hours is presented. A dual (or quadruple) arrangement of electro-optical channels is set up in the lidar receiver. Each channel contains its own optical spectral response as determined by an appropriate set of interference filters. The incoming signal is split and fed into two channels, filtered (simultaneously) and then inserted into the input terminals of an operational amplifier. The difference signal is selected and amplified whereas the common portion of the signal is highly attenuated (Common Mode Re.jection Ratio = 75-80db). For the present hardware, daylight intensities 10(exp 2)-10(exp 3) times Raman signals are received simultaneously. Mean values of intensities of daylight signals which give rise to a constant differences merely shift the value of the measured variable at the ground. These mean value signals have their common part highly attenuated. The differences of the fluctuation portions of the daylight signal represents a noise signal. Identical (space-time) optical paths for each component of the daylight signal produce the same fluctuational spectra in each channel. Hence noise levels, much less than signal levels, are anticipated. First a N2-H2 ) signal pair is differenced. Then an N2-O2 pair is differenced and used for instrumental normalization purposes. Signal levels to be encountered are quite well known as a result of prior field work. Improved optical design of laser system can reduce mean value of daylight intensities by 10(exp 2). Thus the mean daylight intensity can be set equal to the expected signal levels by more advanced optical design. Performance characteristics of photomultiplier pairs are discussed in this connection.

Cooney, John↗

Space applications.

Laser in space application, discussing electro- optical devices

ELECTRO-OPTICS↗