Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Levelized Cost of Charging Electric Vehicles

This data set includes the levelized cost of charging (LCOC) and lifetime fuel cost savings (LFCS) values as reported in "Levelized Cost of Charging of Electric Vehicles in the United States." Values are reported at the state and national levels for battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs). The data set also includes the four annual direct current fast charging (DCFC) station load profiles used to approximate the levelized cost of DCFC charging. Each profile provides 15-min resolved power requirements for one full year. Borlaug, B., Salisbury, S., Gerdes, M., and Muratori, M., Levelized Cost of Charging Electric Vehicles in the United States, Joule (2020), https://doi.org/10.1016/j.joule.2020.05.013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Levelized Cost of Charging Electric Vehicles

This data set includes the levelized cost of charging (LCOC) and lifetime fuel cost savings (LFCS) values as reported in "Levelized Cost of Charging of Electric Vehicles in the United States." Values are reported at the state and national levels for battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs). The data set also includes the four annual direct current fast charging (DCFC) station load profiles used to approximate the levelized cost of DCFC charging. Each profile provides 15-min resolved power requirements for one full year. Borlaug, B., Salisbury, S., Gerdes, M., and Muratori, M., Levelized Cost of Charging Electric Vehicles in the United States, Joule (2020), https://doi.org/10.1016/j.joule.2020.05.013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decentralized oscillator-based converter control

A device includes a control unit that includes an oscillator circuit. The control unit is configured to generate, based on the oscillator circuit, at least one switching signal. The device also includes a direct current (DC)-to-DC conversion circuit comprising at least one electronic switch that is operatively coupled to the control unit. The DC-to-DC conversion circuit is configured to convert, based on the at least one switching signal, a DC input voltage to a DC output voltage, and the control unit is further configured to input, to the oscillator circuit, a current signal that is generated based on a measured output current of the DC-to-DC conversion circuit.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Converter with phase-offset switching

Various examples are directed to electrical converters and systems for operating the same. An electrical converter may comprise a first converter module configured to receive a first direct current (DC) input and provide a first output. The first converter module may comprise a first switch modulated according to a first switch control signal. A second converter module may be configured to receive a second DC input and provide a second output. The second converter module may be connected in series with the first converter module. The second converter module may comprise a second switch modulated according to a second switch control signal. A phase of the first switch control signal may be offset from a phase of the second switch control signal by a first phase offset.

Bhowmik, Shibashis↗

Variable loop gain using excessive regeneration for a delayed wide-area control system

Disclosed are methods and systems for adjusting a High Voltage Direct Current (HVDC) compensator output signal to an HVDC system to reduce control loop modulus due to excessive time delay of sensor measurements. Two different time windows, a Short-Time Variance Window (STVW) and an Extended-Time Variance Window (ETVW) may be examined for detection of increased energy. To detect increased energy the HVDC compensator output signal may be passed through a bandpass filter, then variances for the STVW and ETVW may be generated to produce corresponding test statistics. The STVW and ETVW test statistics may be compared to hypothesis test thresholds and have binary logic based on the hypothesis test comparisons used to generate a gain. The gain may then be multiplied times the original HVDC feedback compensator output such that the adjusted HVDC feedback compensator output reduces the control loop modulus when applied to the HVDC system.

Roberson, Dakota↗

Fault-tolerant power-distribution modules for a power plant

Embodiments are directed to fault-tolerant power-distribution modules (PDM). A PDM is included in a power plant to provide a portion of the power generated by the plant as a direct current (DC) signal for the operation of the plant. A power-distribution system distributes a portion of the power generated by the plant to one or more PDMs, as an alternating current (AC) signal. The PDMs provide electrical power to various plant loads. The plant loads may be related to the safety of the operation of the power plant. At least one of the plant loads is a non-safety related load. A PDM may be a DC power supply. The power plant may include one or more power-generating module (PGM) assemblies. At least one of the PGM assemblies may include a nuclear reactor. Accordingly, the power plant may be a modular nuclear power plant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inverter communications using output signal

Technologies for communicating information from an inverter configured for the conversion of direct current (DC) power generated from an alternative source to alternating current (AC) power are disclosed. The technologies include determining information to be transmitted from the inverter over a power line cable connected to the inverter and controlling the operation of an output converter of the inverter as a function of the information to be transmitted to cause the output converter to generate an output waveform having the information modulated thereon.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of Material Condition on Stress Corrosion Crack Initiation of Cold-Worked Alloy 600 in Simulated PWR Primary Water

The effect of material condition and grain boundary (GB) carbides on stress corrosion crack (SCC) initiation was evaluated on a cold-worked Alloy 600 heat in the solution annealed and thermally treated conditions. SCC initiation response of these material conditions were investigated by constant load testing in simulated pressurized water reactor primary coolant environments. Direct current potential drop technique was used for in-situ detection of SCC initiation. With periodic examination of the specimens, evolution of precursor damage including intergranular attack and short cracks was carefully documented and compared to data previously obtained from unstressed coupons with the same material conditions and were exposed to the same environment. Results revealed a predominant role of mechanical factors in the development of precursor damage with no apparent improvement of GB carbides on SCC initiation resistance.

Zhai, Ziqing↗

Crack Initiation Behavior of Cold-Worked Alloy 690 in Simulated PWR Primary Water - Role of Starting Microstructure, Applied Stress and Cold Work on Precursor Damage Evolution

Long-term stress corrosion crack (SCC) initiation behavior in Alloy 690 is being evaluated by constant load tensile testing in simulated pressurized water reactor primary water. Seven commercial Alloy 690 heats with different starting microstructures and cold-work levels are being tested at either 90% or 100% of the material yield stress. Previous studies have revealed grain boundary (GB) cavity formation after 7,110 to 9,220 hours of exposure in certain thermally treated (TT) Alloy 690 heats in highly cold-worked (CW) conditions, serving as precursors to intergranular cracks. This paper summarizes the new characterization results for the evolution of GB cavities in four Alloy 690TT heats in 21% and 31%CW conditions loaded at yield stress after 18,400 hours of exposure. Link-up of GB cavities has led to formation of long internal creep cracks, resulting in crack initiation detected by direct current potential drop in a highly CW Alloy 690TT heat with uniform, semi-continuous distribution of small GB carbides. In comparison, highly CW materials featuring larger and more widely spaced GB carbides did not show a significant increase in GB cavity density or size. Quantitative assessments were performed on GB cavity evolution in highly CW specimens for two Alloy 690TT heats demonstrating the strong dependence of GB cavity evolution on applied stress and starting GB microstructure.

Zhai, Ziqing↗

Advanced High-Fidelity Lumped EMT Grid Modelling & Comparison

There is increased interest in performing electromagnetic transient (EMT) studies of large power grids for stability purposes. The large power grids may not represent the entire grid, but portions of interest. For example, studies are being performed to identify the impact of extreme events on solar power plants in California that requires the EMT model of the grid in California, but not the complete western interconnection (WI) grid model to which the grid in California is connected. The EMT models of grids are necessary to perform integration studies of large power electronics systems like utility-scale photovoltaic (PV) systems, high-voltage direct current (HVdc) systems, flexible alternating current transmission systems (FACTs), and others. Traditionally, models of grids available to utilities are the transient stability (TS) models. Hence, it assumes significance to identify methods of developing high-fidelity EMT models for portions of the grid (of interest) from the information available in the existing TS models of the entire grid. In this paper, a conversion mechanism along with upgradation based on data-driven methods is applied to develop EMT models of grids. The conversion mechanism utilizes information from TS models of grids to generate EMT models of grids. These models can be extracted for the required portion of the grid. While these models adequately represent the local voltage behaviour of the grid, they are inadequate in representing the frequency behaviour of the grid. The data-driven methods are applied to identify frequency dynamics of the grid, and the EMT models are upgraded with the data-driven methods. The resulting upgraded EMT models of grids can perform the studies mentioned above. These models are tested under contingencies of interest to validate the developed models.

Debnath, Suman↗

Direct-DC Power in Buildings: Identifying the Best Applications Today for Tomorrow’s Building Sector

Driven by the increased use of direct current (DC) sources (photovoltaics, battery storage) and DC end-use devices (electronics, solid-state lighting, efficient motors), DC power distribution in buildings and DC microgrids have been proposed as a way to achieve greater efficiency, cost savings, and resiliency in a transitioning building sector. Despite these important benefits, several market and technological barriers inhibit the development of DC distribution, and the market for DC in buildings is still largely in the demonstration phase. Therefore, to jumpstart this technology, a clear path forward must emerge at this early stage of deployment. The goal of this paper is to define specific end-use cases for which DC distribution in buildings is a value proposition today by defining clear efficiency and resiliency benefits while addressing barriers to implementation. The paper begins with a technology and market assessment of DC distribution equipment, end uses, and technology standards. That is followed by results from an expert elicitation of DC power and building end-use professionals (e.g., electrical designers, building operators, engineers) and reports on-site visits and lessons learned from successful (and less successful) field deployments of DC distribution projects in North America. We present specific adoption pathways at the community and building level that can be implemented today, and evaluate them using qualitative and quantitative metrics, such as technology and market readiness, energy savings, and resiliency.

building-level electrical distribution↗

Hybrid EMT-TS Simulation Strategies to Study High Bandwidth MMC-Based HVdc Systems

Modular multilevel converters (MMCs) are widely used in the design of modern high-voltage direct current (HVdc) transmission system. High-fidelity dynamic models of MMCs-based HVdc system require small simulation time step and can be accurately modeled in electro-magnetic transient (EMT) simulation programs. The EMT program exhibits slow simulation speed and limitation on the size of the model and brings certain challenges to test the high-fidelity HVdc model in system-level simulations. This paper presents the design and implementation of a hybrid simulation framework, which enables the co-simulation of the EMT model of Atlanta-Orlando HVdc line and the transient stability (TS) model of the entire Eastern Interconnection system. This paper also introduces the implementation of two high-fidelity HVdc line models simulated at different time steps and discusses a dedicated method for sizing the buffer areas on both sides of the HVdc line. The simulation results of the two HVdc models with different sizes of buffer areas are presented and compared.

Liu, Yuan↗

Micro-inverter assembly for use in a photovoltaic system and method of making same

A micro-inverter assembly for use in a photovoltaic system includes a housing, a direct current (DC)-to-alternating current (AC) micro-inverter disposed within the housing, and a DC connector electrically coupled to the DC-to-AC micro-inverter. The DC connector is positioned within a recess formed in a bottom surface of the housing such that at least one electrical contact of the DC connector is accessible from outside the housing. According to alternative embodiments, the DC connector comprises a plug-and-play connector constructed for one of a rotational engagement and a translational engagement with a DC connector of a photovoltaic (PV) panel.

Cioffi, Philip Michael↗

Power converter circuitry for photovoltaic devices

Power converter circuitry includes a direct current (DC) input comprising a first DC input node and a second DC input node, an alternating current (AC) output comprising a first AC output node coupled to the first DC input node and a second AC output node, a first boost switch coupled between the second DC input node and a boost intermediate node, a second boost switch coupled between the boost intermediate node and a common node, a boost inductor coupled between the boost intermediate node and the first DC input node, a link capacitor coupled between the second DC input node and the common node, a first half-bridge switch coupled between the second DC input node and a half-bridge intermediate node, a second half-bridge switch coupled between the half-bridge intermediate node and the common node, and a half-bridge inductor coupled between the half-bridge intermediate node and the second AC output node.

Ayyanar, Rajapandian↗

Direct-DC Power in Buildings: Identifying the Best Applications Today for Tomorrow’s Building Sector

Driven by the increased use of direct current (DC) sources (photovoltaics, battery storage) and DC end-use devices (electronics, solid-state lighting, efficient motors), DC power distribution in buildings and DC microgrids have been proposed as a way to achieve greater efficiency, cost savings, and resiliency in a transitioning building sector.Despite these important benefits, several market and technological barriers inhibit the development of DC distribution, and the market for DC in buildings is still largely in the demonstration phase. Therefore, to jumpstart this technology, a clear path forward must emerge at this early stage of deployment. The goal of this paper is to define specific end-use cases for which DC distribution in buildings is a value proposition today by defining clear efficiency and resiliency benefits while addressing barriers to implementation.The paper begins with a technology and market assessment of DC distribution equipment, end uses, and technology standards. That is followed by results from an expert elicitation of DC power and building end-use professionals (e.g., electrical designers, building operators, engineers) and reports on-site visits and lessons learned from successful (and less successful) field deployments of DC distribution projects in North America. We present specific adoption pathways at the community and building level that can be implemented today, and evaluate them using qualitative and quantitative metrics, such as technology and market readiness, energy savings, and resiliency.

Vossos, Evangelos↗

Optoelectronic memristor devices including one or more solid electrolytes with electrically controllable optical properties

An optoelectronic memristor includes a first electrode, a second electrode, and a solid electrolyte in between that is in electrical communication with the first electrode and the second electrode. The solid electrolyte has an electronic conductivity of about 10 −10 Siemens/cm to about 10 −4 Siemens/cm at room temperature. The first electrode, and optionally the second electrode, can be optically transparent at a specific wavelength and/or a wavelength range. A direct current (DC) voltage source is employed to apply an electric field across the solid electrolyte, which induces a spatial redistribution of ionic defects in the solid electrolyte. In turn, this causes a change in electrical resistance of the solid electrolyte. The application of the electric field can also cause a change in an optical property of the solid electrolyte at the specific wavelength, and/or at the wavelength range (or a portion thereof).

Defferriere, Thomas↗

Motor and drive arrangement for refrigeration system

A heat exchanger system includes a heat exchanger coil circulating a first heat transfer fluid therethrough, and a fan at least partially surrounded by the heat exchanger coil to urge a flow of air through the heat exchanger coil to dissipate thermal energy from the first heat transfer fluid. A brushless direct current fan motor is located the fan to urge rotation of the fan and an ancillary electrical component operably connected to the heat exchanger system and electrically isolated from the first heat transfer fluid.

Feng, Yinshan↗

Improvements to the Powder Processing of near-Final Shape alnico Magnets

Alnico permanent magnets (PMs), a recent PM system of interest as an attractive rare earth-free PM alternative, have advantageous high operating temperature and magnetic saturation with the potential for utilization in electric machines, e.g. interior-PM motors found in electric vehicles, if current directional solidification methods can be replaced by a true mass production approach. Recently, two unique alnico compositions, termed Full-Co and Co-lean, with improved coercivity, were gas atomized, compression molded, and vacuum sintered (4h at 1240°C) to high densities of 97.8% and 99.3%, respectively. However, the Co-lean remained fine grained isotropic magnets and the Full-Co grains were not textured, lowering magnetic strength in spite of attempts to grow large textured grains by a stress-biased solid state grain alignment method to convert them to high energy anisotropic magnets. It was hypothesized that oxidation during de-binding in air left many prior particle boundary oxides within the sintered microstructure that hindered grain growth and texturing during the stress-biased texturing procedure and prevented the desired abnormal grain growth (AGG). Here we explored a vacuum de-binding step that was linked (in-place) to vacuum sintering and found that the Co-lean exhibited faster uniform grain growth that doubled the average grain size (40 μm to 80 μm). Linked vacuum de-binding and sintering of Full-Co produced some AGG after only 1 h of 1240°C sintering. A new direction for promoting AGG (and stress-biased texturing) in alnico is being explored that utilizes a fundamental analysis of systems with second phase particles that either inhibit or boost grain growth. This effort explores the influence of vacuum de-binding linked to a series of lower sintering temperatures at a fixed time (4h) to see if oxide particle size and volume fraction can be changed to promote AGG conditions in alnico. Surprising qualitative results indicate that AGG may be promoted for vacuum sintering at less than 1200°C.

Rinko, Emily↗