Understanding Differences in California Climate Projections Produced by Dynamical and Statistical Downscaling

Abstract We compare historical and end‐of‐century temperature and precipitation patterns over California from one dynamically downscaled simulation using the Weather Research and Forecast (WRF) model and two simulations statistically downscaled using Localized Constructed Analogs (LOCA). We uniquely separate causes of differences between dynamically and statistically based future climate projections into differences in historical climate (gridded observations versus regional climate model output) and differences in how these downscaling techniques explicitly handle future climate changes (numerical modeling versus analogs). In these methods, solutions between different downscaling techniques differ more in the future compared to the historical period. Changes projected by LOCA are insensitive to the choice of driving data. Only through dynamical downscaling can we simulate physically consistent regional springtime warming patterns across the Sierra Nevada, while the statistical simulations inherit an unphysical signal from their parent Global Climate Model (GCM) or gridded data. The results of our study clarify why these different techniques produce different outcomes and may also provide guidance on which downscaled products to use for certain impact analyses in California and perhaps other Mediterranean regimes.

54 ENVIRONMENTAL SCIENCES↗

Studies on morphology of Langmuir-Blodgett films of stearic acid deposited with different orientation of substrates with respect to compression

The Langmuir monolayer at an air-water interface shows remarkably different surface pressure – area isotherm, when measured with the surface normal of a Wilhemly plate parallel or perpendicular to the direction of compression of the monolayer. Such difference arises due to difference in stress exerted by the monolayer on the plate in different direction. In this article, we report the effect of changing the direction of substrate normal with respect to the compression of the monolayer during Langmuir-Blodgett (LB) film deposition on the morphology of the films. The morphology of the LB film of stearic acid was studied using an atomic force microscope (AFM). The morphology of the LB films was found to be different due to difference in the stress in different directions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE DIFFERENT EVOLUTION OF GAS AND DUST IN DISKS AROUND SUN-LIKE AND COOL STARS

Planet formation is profoundly impacted by the properties of protoplanetary disks and their central star. However, how disk properties vary with stellar parameters remains poorly known. Here, we present the first comprehensive, comparative Spitzer/IRS study of the dust and gas properties of disks around young Sun-like stars (K1-M5) and cool stars/brown dwarfs (M5-M9). The comparison of these two large samples of over 60 sources reveal major differences in the evolution of both the dust and gas components. We report the first detection of organic molecules in disks around brown dwarfs. The detection rate statistics and the line flux ratios of HCN and C{sub 2}H{sub 2} show a striking difference between the two samples, demonstrating a significant underabundance of HCN relative to C{sub 2}H{sub 2} in the disk surface of cool stars. We propose this to originate from the large difference in the UV irradiation around the two types of sources. The statistical comparison of the 10 {mu}m silicate emission features also reveals a difference between the two samples. Cool stars and brown dwarfs show weaker features arising from more processed silicate grains in the disk atmosphere. These findings complement previous indications of flatter disk structures and longer disk lifetimes around cool stars. Our results highlight important differences in the chemical and physical evolution of protoplanetary disks as a function of stellar mass, temperature, and radiation field which should be taken into account in planet formation models. We note that the different chemistry of preplanetary materials in the disk may also influence the bulk composition and volatile content of the forming planets. In particular, if exogenous HCN has played a key role in the synthesis of prebiotic molecules on Earth as proposed, then prebiotic chemistry may unfold differently on planets around cool stars.

99 GENERAL AND MISCELLANEOUS↗

The magnetic field and polarization properties of radio galaxies in different accretion states

We use the integrated polarized radio emission at 1.4 GHz (Π{sub 1.4 GHz}) from a large sample of active galactic nuclei (AGN; 796 sources at redshifts z<0.7) to study the large-scale magnetic field properties of radio galaxies in relation to the host galaxy accretion state. We find a fundamental difference in Π{sub 1.4 GHz} between radiative-mode AGN (i.e., high-excitation radio galaxies (HERGs) and radio-loud QSOs) and jet-mode AGN (i.e., low-excitation radio galaxies (LERGs)). While LERGs can achieve a wide range of Π{sub 1.4 GHz} (up to ∼30%), the HERGs and radio-loud QSOs are limited to Π{sub 1.4 GHz}≲15%. A difference in Π{sub 1.4 GHz} is also seen when the sample is divided at 0.5% of the total Eddington-scaled accretion rate, where the weakly accreting sources can attain higher values of Π{sub 1.4 GHz}. We do not find any clear evidence that this is driven by intrinsic magnetic field differences of the different radio morphological classes. Instead, we attribute the differences in Π{sub 1.4 GHz} to the local environments of the radio sources, in terms of both the ambient gas density and the magnetoionic properties of this gas. Thus, not only are different large-scale gaseous environments potentially responsible for the different accretion states of HERGs and LERGs, we argue that the large-scale magnetized environments may also be important for the formation of powerful AGN jets. Upcoming high angular resolution and broadband radio polarization surveys will provide the high-precision Faraday rotation measure and depolarization data required to robustly test this claim.

79 ASTRONOMY AND ASTROPHYSICS↗

THE LINE WIDTH DIFFERENCE OF NEUTRALS AND IONS INDUCED BY MHD TURBULENCE

We address the problem of the different line widths of coexistent neutrals and ions observed in molecular clouds and explore whether this difference can arise from the effects of magnetohydrodynamic (MHD) turbulence acting on partially ionized gas. Among the three fundamental modes of MHD turbulence, we find that fast and slow modes do not contribute to line width differences. We focus on the Alfvénic component, and consider the damping of Alfvén modes by taking into account both neutral-ion collisions and neutral viscosity. We confirm that the line width difference can be explained by the differential damping of the Alfvénic turbulence in ions and the hydrodynamic turbulence in neutrals, and find it strongly depends on the properties of MHD turbulence. We consider various regimes of turbulence corresponding to different media magnetizations and turbulent drivings. In the case of super-Alfvénic turbulence, when the damping scale of Alfvénic turbulence is below the Alfvénic scale l{sub A}, the line width difference does not depend on magnetic field strength. In other turbulence regimes, however, the dependence is present and evaluation of magnetic field from the observed line width difference is possible.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-422: Correlation Between 2D Passing Rates and 3D Dose Differences for Pretreatment VMAT QA

Purpose: Volumetric modulated arc therapy (VMAT) quality assurance (QA) is typically using QA methods and action levels taken from fixedbeam intensity-modulated radiotherapy (IMRT) QA methods. However, recent studies demonstrated that there is no correlation between the percent gamma passing rate (%GP) and the magnitude of dose discrepancy between the planned dose and the actual delivered dose for IMRT. The purpose of this study is to investigate whether %GP is correlated with clinical dosimetric difference for VMAT. Methods: Twenty nasopharyngeal cancer (NPC) patients treated with dual-arc simultaneous integrated boost VMAT and 20 esophageal cancer patients treated with one-arc VMAT were enrolled in this study. Pretreatment VMAT QA was performed by a 3D diode array ArcCheck. Acceptance criteria of 2%/2mm, 3%/3mm, and 4%/4mm were applied for 2D %GP. Dose values below 10% of the per-measured normalization maximum dose were ignored.Mean DVH values obtained from 3DVH software and TPS were calculated and percentage dose differences were calculated. Statistical correlation between %GP and percent dose difference was studied by using Pearson correlation. Results: The %GP for criteria 2%/2mm, 3%/3mm, and 4%/4mm were 82.33±4.45, 93.47±2.31, 97.13±2.41, respectively. Dose differences calculated from 3DVH and TPS for beam isocenter, mean dose of PTV, maximum dose of PTV, D2 of PTV and D98 of PTV were -1.04±3.24, -0.74±1.71, 2.92±3.62, 0.89±3.29, -1.46±1.97, respectively. No correction were found between %GP and dose differences. Conclusion: There are weak correlations between the 2D %GP and dose differences calculated from 3DVH. The %GP acceptance criteria of 3%/3mm usually applied for pretreatment QA of IMRT and VMAT is not indicating strong clinical correlation with 3D dose difference. 3D dose reconstructions on patient anatomy may be necessary for physicist to predict the accuracy of delivered dose for VMAT QA.

60 APPLIED LIFE SCIENCES↗

Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

Purpose: A surface electronic brachytherapy (EBT) device is in fact an x-ray source collimated with specific applicators. Low-energy (<100 kVp) x-ray beam dosimetry faces several challenges that need to be addressed. A number of calibration protocols have been published for x-ray beam dosimetry. The media in which measurements are performed are the fundamental difference between them. The aim of this study was to evaluate the surface dose rate of a low-energy x-ray source with small field applicators using different calibration standards and different small-volume ionization chambers, comparing the values and uncertainties of each methodology. Methods: The surface dose rate of the EBT unit Esteya (Elekta Brachytherapy, The Netherlands), a 69.5 kVp x-ray source with applicators of 10, 15, 20, 25, and 30 mm diameter, was evaluated using the AAPM TG-61 (based on air kerma) and International Atomic Energy Agency (IAEA) TRS-398 (based on absorbed dose to water) dosimetry protocols for low-energy photon beams. A plane parallel T34013 ionization chamber (PTW Freiburg, Germany) calibrated in terms of both absorbed dose to water and air kerma was used to compare the two dosimetry protocols. Another PTW chamber of the same model was used to evaluate the reproducibility between these chambers. Measurements were also performed with two different Exradin A20 (Standard Imaging, Inc., Middleton, WI) chambers calibrated in terms of air kerma. Results: Differences between surface dose rates measured in air and in water using the T34013 chamber range from 1.6% to 3.3%. No field size dependence has been observed. Differences are below 3.7% when measurements with the A20 and the T34013 chambers calibrated in air are compared. Estimated uncertainty (with coverage factor k = 1) for the T34013 chamber calibrated in water is 2.2%–2.4%, whereas it increases to 2.5% and 2.7% for the A20 and T34013 chambers calibrated in air, respectively. The output factors, measured with the PTW chambers, differ by less than 1.1% for any applicator size when compared to the output factors that were measured with the A20 chamber. Conclusions: Measurements using both dosimetric protocols are consistent, once the overall uncertainties are considered. There is also consistency between measurements performed with both chambers calibrated in air. Both the T34013 and A20 chambers have negligible stem effect. Any x-ray surface brachytherapy system, including Esteya, can be characterized using either one of these calibration protocols and ionization chambers. Having less correction factors, lower uncertainty, and based on measurements, performed in closer to clinical conditions, the TRS-398 protocol seems to be the preferred option.

60 APPLIED LIFE SCIENCES↗

SU-F-T-430: Validation of IBEAM Evo Couch Top for Different Relative Electron Density (RED) Combination During Photon Beam Dose Calculation in Monaco− Treatment Planning System

Purpose: Validation of iBEAM™ evo couch-top for different relative electron density (RED) combination during photon beam dose calculation in Monaco− TPS. Methods: The iBEAM™ evo couch-top has two layers:outer carbon fiber (CF) and inner foam core (FC). To study the beam intensity attenuation of couch-top, measured doses were compared with doses calculated for different REDs. Measurements were performed in solid water phantom with PTW-0.125cc ion-chamber positioned at center of the phantom with 5.3cm thickness slabs placed above and below the chamber. Similarly, in TPS, iBEAM™ evo couch-top was simulated and doses were calculated for different RED combinations (0.2CF-0.2FC, 0.4CF-0.2FC, 0.6CF-0.2FC, 0.8CF-0.2FC, and 1.0CF-0.2FC) by using Monte Carlo dose calculation algorithm in Monaco TPS (V5.1). Doses were measured for every 10 degree gantry angle separation, 10×10cm{sup 2} field size and 6MV photons. Then, attenuation is defined as the ratio of output at posterior gantry angle to output of its opposed anterior gantry angle (e.g.225°/45°). output fluctuation with different gantry angle was within ±0.21%. To confirm above results, dose-planes were measured for five pelvic VMAT plans (360°arc) in PTW two-dimensional array and compared with different calculated dose-planes of above-mentioned couch REDs. Gamma pass rates<1.00) were analyzed for 3%/2mm criteria. Results: Measured and calculated attenuation was in good agreement for the RED combination of 0.2CF-0.2FC and difference was within ±0.515%. However, other density combination showed difference of ±0.9841%, ±1.667%, ±2.9241% and ±2.8832% for 0.4CF-0.2FC, 0.6CF-0.2FC, 0.8CF-0.2FC, and 1.0CF-0.2FC, respectively. Maximum couch-top attenuation was observed at 110°–120° and 240°–250° and decreases linearly as the gantry angle approaches 180°. Moreover, gamma pass rate confirmed the above results and showed maximum pass rate of 96.23% for 0.2CF-0.2FC, whereas others were 95.72%, 95.12%, 94.31% and 93.24%. Conclusion: RED value of 0.2CF-0.2FC was found to be suitable for accurate couch-top modeling for 6MV photon beam Monte Carlo calculations in Monaco TPS.

07 ISOTOPE AND RADIATION SOURCES↗

SU-G-IeP4-10: Microimaging for Different Degrees of Human Cavernous Hemangioma of Liver by Using In-Line Phase-Contrast Imaging CT

Purpose: Cavernous hemangioma of the liver (CHL) is the most common benign solid tumor of the liver. In this study, we quantitative assessment the different degrees of CHL from microscopic viewpoint by using in-line phase-contrast imaging CT (ILPCI-CT). Methods: The experiments were performed at x-ray imaging and biomedical application beamline (BL13W1) of Shanghai Synchrotron Radiation Facility (SSRF) in China. Three typical specimens at different stages, i.e., mild, moderate and severe human CHL were imaged using ILPCI-CT at 16keV without contrast agents. The 3D visualization of different degrees of CHL samples were presented using ILPCI-CT. Additionally, quantitative evaluation of the CHL features, such as the range of hepatic sinusoid equivalent diameters in different degrees of CHL samples, the ratio of the hepatic sinusoid to the CHL tissue, were measured. Results: The planar image clearly displayed the dilated hepatic sinusoids in microns. There was no normal hepatic vascular found in the all CHL samples. Different stages of CHL samples were presented with vivid shapes and stereoscopic effects by using 3D visualization. The equivalent diameters of hepatic sinusoids in three degrees CHL were different. The equivalent diameters of the hepatic sinusoids in mild CHL, range from 60 to 120 µm. The equivalent diameters of the hepatic sinusoids in moderate CHL, range from 65 to 190 µm. The equivalent diameters of the hepatic sinusoids in severe CHL, range from 95 to 215 µm. The ratio of the hepatic sinusoid to the mild, moderate and severe CHL tissue were 3%, 16% and 21%, respectively. Conclusion: The results show that the high degree of sensitivity of the ILPCI-CT technique and demonstrate the feasibility of accurate visualization of different stage human CHL. ILPCI-CT may offers a potential use in non-invasive study and analysis of CHL.

60 APPLIED LIFE SCIENCES↗

Colonization of Naive Roots from Populus tremula × alba Involves Successive Waves of Fungi and Bacteria with Different Trophic Abilities

ABSTRACT Through their roots, trees interact with a highly complex community of microorganisms belonging to various trophic guilds and contributing to tree nutrition, development, and protection against stresses. Tree roots select for specific microbial species from the bulk soil communities. The root microbiome formation is a dynamic process, but little is known on how the different microorganisms colonize the roots and how the selection occurs. To decipher whether the final composition of the root microbiome is the product of several waves of colonization by different guilds of microorganisms, we planted sterile rooted cuttings of gray poplar obtained from plantlets propagated in axenic conditions in natural poplar stand soil. We analyzed the root microbiome at different time points between 2 and 50 days of culture by combining high-throughput Illumina MiSeq sequencing of the fungal ribosomal DNA internal transcribed spacer and bacterial 16S rRNA amplicons with confocal laser scanning microscopy observations. The microbial colonization of poplar roots took place in three stages, but bacteria and fungi had different dynamics. Root bacterial communities were clearly different from those in the soil after 2 days of culture. In contrast, if fungi were also already colonizing roots after 2 days, the initial communities were very close to that in the soil and were dominated by saprotrophs. They were slowly replaced by endophytes and ectomycorhizal fungi. The replacement of the most abundant fungal and bacterial community members observed in poplar roots over time suggest potential competition effect between microorganisms and/or a selection by the host. IMPORTANCE The tree root microbiome is composed of a very diverse set of bacterial and fungal communities. These microorganisms have a profound impact on tree growth, development, and protection against different types of stress. They mainly originate from the bulk soil and colonize the root system, which provides a unique nutrient-rich environment for a diverse assemblage of microbial communities. In order to better understand how the tree root microbiome is shaped over time, we observed the composition of root-associated microbial communities of naive plantlets of poplar transferred in natural soil. The composition of the final root microbiome relies on a series of colonization stages characterized by the dominance of different fungal guilds and bacterial community members over time. Our observations suggest an early stabilization of bacterial communities, whereas fungal communities are established following a more gradual pattern.

59 BASIC BIOLOGICAL SCIENCES↗

How Do Environmental Conditions Influence Vertical Buoyancy Structure and Shallow-to-Deep Convection Transition across Different Climate Regimes?

Abstract We developed an entraining parcel approach that partitions parcel buoyancy into contributions from different processes (e.g., adiabatic cooling, condensation, freezing, and entrainment). Applying this method to research-quality radiosonde profiles provided by the Atmospheric Radiation Measurement (ARM) program at six sites, we evaluated how atmospheric thermodynamic conditions and entrainment influence various physical processes that determine the vertical buoyancy structure across different climate regimes as represented by these sites. The differences of morning buoyancy profiles between the deep convection (DC)/transition cases and shallow convection (SC)/nontransition cases were used to assess preconditions important for shallow-to-deep convection transition. Our results show that for continental sites such as the U.S. Southern Great Plains (SGP) and west-central Africa, surface conditions alone are enough to account for the buoyancy difference between DC and SC cases, although entrainment further enhances the buoyancy difference at SGP. For oceanic sites in the tropical west Pacific, humidity dilution in the lower to middle free troposphere (~1–6 km) and temperature mixing in the middle to upper troposphere (>4 km) have the most important influences on the buoyancy difference between DC and SC cases. For the humid central Amazon region, entrainment in both the boundary layer and the lower free troposphere (~0–4 km) have significant contributions to the buoyancy difference; the upper-tropospheric influence seems unimportant. In addition, the integral of the condensation term, which represents the parcel’s ability to transform available water vapor into heat through condensation, provides a better discrimination between DC and SC cases than the integral of buoyancy or the convective available potential energy (CAPE).

54 ENVIRONMENTAL SCIENCES↗

Microbiome differences in sugarcane and metabolically engineered oilcane accessions and their implications for bioenergy production

Abstract Oilcane is a metabolically engineered sugarcane ( Saccharum spp. hybrid) that hyper-accumulates lipids in its vegetable biomass to provide an advanced feedstock for biodiesel production. The potential impact of hyper-accumulation of lipids in vegetable biomass on microbiomes and the consequences of altered microbiomes on plant growth and lipid accumulation have not been explored so far. Here, we explore differences in the microbiome structure of different oilcane accessions and non-modified sugarcane. 16S SSU rRNA and ITS rRNA amplicon sequencing were performed to compare the characteristics of the microbiome structure from different plant compartments (leaf, stem, root, rhizosphere, and bulk soil) of four greenhouse-grown oilcane accessions and non-modified sugarcane. Significant differences were only observed in the bacterial microbiomes. In leaf and stem microbiomes, more than 90% of the entire microbiome of non-modified sugarcane and oilcane was dominated by similar core taxa. Taxa associated with Proteobacteria led to differences in the non-modified sugarcane and oilcane microbiome structure. While differences were observed between multiple accessions, accession 1566 was notable in that it was consistently observed to differ in its microbial membership than other accessions and had the lowest abundance of taxa associated with plant-growth-promoting bacteria. Accession 1566 is also unique among oilcane accessions in that it has the highest constitutive expression of the WRI 1 transgene. The WRI 1 transcription factor is known to contribute to significant changes in the global gene expression profile, impacting plant fatty acid biosynthesis and photomorphogenesis. This study reveals for the first time that genetically modified oilcanes associate with distinct microbiomes. Our findings suggest potential relationships between core taxa, biomass yield, and TAG in oilcane accessions and support further research on the relationship between plant genotypes and their microbiomes.

09 BIOMASS FUELS↗

Comparison and investigation of production of specific nuclides by different fission yield data

Generally, passive gamma spectroscopy (PGS) is known as a useful technique for nondestructive measurement of burnup and nuclide production in normal spent nuclear fuel. However, PGS can be used not only for normal spent fuel, but also for molten fuel generated in severe accidents involving core meltdowns. In such cases, it is estimated by the radioactivity ratios of specific nuclides. At the time of the decommissioning of the Three Mile Island's unit 2 reactor, fission products (FPs) such as Cs{sup 134}, Cs{sup 137}, Ce{sup 144}, Eu{sup 154}, Ru{sup 106}, and Sb{sup 125} were concerned. The radioactivity ratios are estimated by numerical simulations. However, there are various uncertainties in numerical simulations. In this study, we evaluated the effect of the difference in fission yield data. We compared the productions of concerned nuclides of Three Mile Island's unit 2 reactor by using Tokyo-tech and JENDL FP Fission Yields Data File 2011(FPY- 2011). Tokyo-tech is newly created by Tsubakihara et al. at Tokyo Institute of Technology. FPY-2011 is currently the latest fission yield data in Japan. In the concerned nuclides, the relative difference (Tokyo-tech/FPY-2011 -1) in the production of Sb{sup 125} is 4.5% and that of Eu{sup 154} is -5.6%. The relative difference in the production of Sb{sup 125} is found to be caused by the difference in the independent yields of Sn{sup 125}, In{sup 125}, Cd{sup 125}, Ag{sup 125}, and Pd{sup 125}. The relative difference in Eu{sup 154} is found to be caused by the relative difference in the production of Sm{sup 152} and the relative difference in the cumulative yield of Eu{sup 153}.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Conserved Developmental Patterning Network Produces Quantitatively Different Output in Multiple Species of Drosophila

Differences in the level, timing, or location of gene expression can contribute to alternative phenotypes at the molecular and organismal level. Understanding the origins of expression differences is complicated by the fact that organismal morphology and gene regulatory networks could potentially vary even between closely related species. To assess the scope of such changes, we used high-resolution imaging methods to measure mRNA expression in blastoderm embryos of Drosophila yakuba and Drosophila pseudoobscura and assembled these data into cellular resolution atlases, where expression levels for 13 genes in the segmentation network are averaged into species-specific, cellular resolution morphological frameworks. We demonstrate that the blastoderm embryos of these species differ in their morphology in terms of size, shape, and number of nuclei. We present an approach to compare cellular gene expression patterns between species, while accounting for varying embryo morphology, and apply it to our data and an equivalent dataset for Drosophila melanogaster. Our analysis reveals that all individual genes differ quantitatively in their spatio-temporal expression patterns between these species, primarily in terms of their relative position and dynamics. Despite many small quantitative differences, cellular gene expression profiles for the whole set of genes examined are largely similar. This suggests that cell types at this stage of development are conserved, though they can differ in their relative position by up to 3–4 cell widths and in their relative proportion between species by as much as 5-fold. Quantitative differences in the dynamics and relative level of a subset of genes between corresponding cell types may reflect altered regulatory functions between species. Our results emphasize that transcriptional networks can diverge over short evolutionary timescales and that even small changes can lead to distinct output in terms of the placement and number of equivalent cells.

59 BASIC BIOLOGICAL SCIENCES↗

In vitro toxicity assessment of uranium particulates on different human lung epithelial cell models

Inhalation of uranium aerosols produced via human activities such as mining can pose a threat to human respiratory systems. Uranium oxide particulates emit short-range alpha particles that elicit DNA and direct damage, beyond associated physiochemical heavy-metal toxicity, to internal epithelial tissues. The availability of reliable in vitro models to study radiation exposure can greatly enhance our ability to understand and combat the biological impacts of exposure. However, the toxicological effects of alpha emissions and/or the oxidation states of uranium particulates vary across different human lung epithelial cell models and have not been systematically compared. We have endeavored to address this limitation by comparing impacts in three different human lung cell models: primary human bronchial and tracheal epithelial cells, primary human small airway epithelial cells, and human adenocarcinoma alveolar basal epithelial cells. Other studies have mainly investigated the toxicity of depleted uranium. Here, we compared the exposure of uranium oxide particulates (U 3 O 8 and UO 3 ) of different enrichment states on the chosen cell systems. Each cell model was exposed to 0.1, 1, 10, 50, 100, and 500 µg/mL of depleted U 3 O 8 , highly-enriched U 3 O 8 , and natural UO 3 particulates for 24 hours in submerged monolayer cultures. We compared viability and superoxide dismutase activity results across cell lines and uranium enrichment/ oxidative states. The results showed that 1) the oxide state of the particulates affected cell viability, implying that uranium’s different oxidation states contribute to different toxicological responses, and 2) each cell model reacts differently when exposed to uranium oxides, which may provide insights into the mechanistic processes associated with the exposure of radiological particulates on different biological systems. For instance, increased uranium enrichment corresponds to increased toxicity for the primary cells, but not for the immortalized cells. Our study shows that a holistic approach that incorporates similarities between model systems and types of radionuclides is required to truly develop empirical solutions for radiation exposure.

59 BASIC BIOLOGICAL SCIENCES↗

Visual Fixations in Basketball Shooting: Differences between Shooting Conditions

Basketball is a sport where shooting is one of the most important factors that determines the success or failure of the teams. Therefore, basketball players need to shoot the ball accurately. The present study aimed to evaluate whether different shooting conditions influence the visual behavior of athletes. For this, the Tobbi Pro Glasses 3 equipment was used to evaluate the time of the first fixation, the number of fixations, and the total time of fixations in the basket, during the shooting movement. Different distances to the basket, simulated gym audience noise, and shooting with opposition were considered. A group of 18 athletes with an average age of 22 ± 3.72 years and an average basketball practice experience of 12.5 ± 4.52 years performed 10 valid shots from different distances and different shooting angles, with different restrictions, namely, shooting with simulated opposition and gym audience noise. Statistically significant differences between shooting with opposition and baseline, in terms of the number of fixations and the total time of fixation, were found. Regarding shooting with gym audience noise, differences only occur for the total time of fixations in one position. Despite this, in all variables and positions, the values were lower in shooting with constraints compared to the baseline.

Amaro, Catarina M. (ORCID:0000000303343503)↗

Finite difference methods for transient signal propagation in stratified dispersive media

Explicit difference equations are presented for the solution of a signal of arbitrary waveform propagating in an ohmic dielectric, a cold plasma, a Debye model dielectric, and a Lorentz model dielectric. These difference equations are derived from the governing time-dependent integro-differential equations for the electric fields by a finite difference method. A special difference equation is derived for the grid point at the boundary of two different media. Employing this difference equation, transient signal propagation in an inhomogeneous media can be solved provided that the medium is approximated in a step-wise fashion. The solutions are generated simply by marching on in time. It is concluded that while the classical transform methods will remain useful in certain cases, with the development of the finite difference methods described, an extensive class of problems of transient signal propagating in stratified dispersive media can be effectively solved by numerical methods.

Lam, D. H.↗

Qualitative differences between on-orbit and transition RCS control

Two separate reaction control system (RCS) digital autopilots (DAPs) evolved from one original Space Shuttle orbital autopilot concept. A computer overload forced this evolution. Part of the overload problem was due to unique performance requirements imposed on the RCS controller during each of several different flight regimes. The two resultant RCS DAPs yield different effector responses because they rely on different sources of sensory input and they process data differently. This paper describes the evolution of the two RCS controllers and illustrates their behavioral differences. The transition autopilot, used in orbital insertion and deorbit, is sensitive to orbiter flexure due to its feedthrough character. The on-orbit autopilot is sensitive to transient rate control degradation from large disturbances due to feed-forward rate estimation. Simulation results and flight data are used to illustrate performance differences between the two autopilots under various conditions. These include computer failures where electronic stringing and procedural reconfiguration differences affect autopilot behavior.