Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Phase-locked servo system

A phase lock servo system is described for synchronizing the rotation of a slip ring assembly with the rotation of an air bearing table so that a minimum of torque will be imparted through cables extending from the slip ring assembly to the air bearing table as such is rotated. The system includes two servo loops. The first servo loop includes a rate gyroscope carried on the air bearing table which generates a signal through a summing junction to be compared with a signal coming from a tachometer coupled to the slip ring assembly. The corrective signal is applied to a torque motor for rotating the slip ring assembly. The second servo loop includes a pair of photo detector cells which generate pulses responsive to the rotation of the air bearing table and slip ring assembly which are fed through a phase detector, and a variable gain amplifier to the summing junction circuit to provide a fine adjustment for rotating the slip ring assembly.

Burdin, C.↗

Blackbody cavity radiometer has rapid response

Fast response, spectrally linear standard detector in the form of a blackbody cavity radiometer calibrates rapidly responding photodetectors against a calibrated standard detector. A power amplifier with maximum available gain reduces error signal without stability loss. It may be used as a blackbody radiator by manipulation of the bridge variable arm.

Haley, F. C.↗

Self-tuning bandpass filter

An electronic filter is described which simultaneously maintains a constant bandwidth and a constant center frequency gain as the input signal frequency varies, and remains self-tuning to that center frequency over a decade range. The filter utilizes a field effect transistor (FET) as a voltage variable resistance in the bandpass frequency determining circuit. The FET is responsive to a phase detector to achieve self-tuning.

Deboo, G. J.↗

Intruder detection system

An intruder detection system is described. The system contains a transmitter which sends a frequency modulated and amplitude modulated signal to a remote receiver in response to a geophone detector which responds to seismic impulses created by the intruder. The signal makes it possible for an operator to determine the number of intruders and the manner of movement.

Lee, R. D.↗

Optimal optoacoustic detector design

Optoacoustic detectors are used to measure pressure changes occurring in enclosed gases, liquids, or solids being excited by intensity or frequency modulated electromagnetic radiation. Radiation absorption spectra, collisional relaxation rates, substance compositions, and reactions can be determined from the time behavior of these pressure changes. Very successful measurements of gaseous air pollutants have, for instance, been performed by using detectors of this type together with different lasers. The measuring instrument consisting of radiation source, modulator, optoacoustic detector, etc. is often called spectrophone. In the present paper, a thorough optoacoustic detector optimization analysis based upon a review of its theory of operation is introduced. New quantitative rules and suggestions explaining how to design detectors with maximal pressure responsivity and over-all sensitivity and minimal background signal are presented.

Rosengren, L.-G.↗

A reinterpretation of the reported energetic particle fluxes in the vicinity of Mercury

During the Mercury flyby of Mariner 10, observations of large fluxes of energetic electrons (energies in excess of 0.3 MeV) and protons (energies between 0.53 and 1.9 MeV) were reported by Simpson et al. (1974). The reported simultaneous enhancements of protons and electrons in the magnetic field of Mercury have raised some perplexing planetology questions. It is shown here that the response of the proton detector in the Mariner 10 experiment is most plausibly attributable to the pileup of low-energy electrons rather than the presence of protons in the vicinity of Mercury. Further, the reported lower-limit electron differential spectrum exponent of at least 9 and the 300-keV electron fluxes are probably in quantitative error, especially where the count rates are highest. It is concluded that no 'new' acceleration mechanism has been identified at Mercury.

Armstrong, T. P.↗

Polarization by a tilted absorbing glass plate

Formulas for the response of an optical detector to the transmitted component of a tilted absorbing glass plate are derived in terms of the angle of incidence, the thickness of the plate, and the absorption coefficient and index of refraction of the glass. Numerical results are discussed for detectors of various sizes compared to the width of the incident beam and thickness of the plate.

Walraven, R. L.↗

Pulsed multiwavelength laser ranging system for measuring atmospheric delay

A multiwavelength laser ranging system has been designed for measuring atmospheric path delay in satellite laser ranging systems. The instrument measures the difference between the propagation times of 532 and 355 nm pulses as a measure of integrated air density. The present design uses a frequency-tripled dye mode-locked Nd:YAG laser as a pulse source and subnanosecond response time photomultipliers as detectors. Studies indicate that recovery of the atmospheric path delay in satellite ranging to the 1-cm level will require the differential arrival time measurements with an accuracy of 3-7 ps. Initial horizontal path test results are presented.

Abshire, J. B.↗

LANDSAT-4 MSS and Thematic Mapper data quality and information content analysis

LANDSAT-4 thematic mapper (TM) and multispectral scanner (MSS) data were analyzed to obtain information on data quality and information content. Geometric evaluations were performed to test band-to-band registration accuracy. Thematic mapper overall system resolution was evaluated using scene objects which demonstrated sharp high contrast edge responses. Radiometric evaluation included detector relative calibration, effects of resampling, and coherent noise effects. Information content evaluation was carried out using clustering, principal components, transformed divergence separability measure, and supervised classifiers on test data. A detailed spectral class analysis (multispectral classification) was carried out to compare the information content of the MSS and TM for a large number of scene classes. A temperature-mapping experiment was carried out for a cooling pond to test the quality of thermal-band calibration. Overall TM data quality is very good. The MSS data are noisier than previous LANDSAT results.

Anuta, P.↗

Landsat-4 MSS and Thematic Mapper data quality and information content analysis

Landsat-4 Thematic Mapper and Multispectral Scanner data were analyzed to obtain information on data quality and information content. Geometric evaluations were performed to test band-to-band registration accuracy. Thematic Mapper overall system resolution was evaluated using scene objects which demonstrated sharp high contrast edge responses. Radiometric evaluation included detector relative calibration, effects of resampling, and coherent noise effects. Information content evaluation was carried out using clustering, principal components, transformed divergence separability measure, and numerous supervised classifiers on data from Iowa and Illinois. A detailed spectral class analysis (multispectral classification) was carried out on data from the Des Moines, IA area to compare the information content of the MSS and TM for a large number of scene classes.

Anuta, P. E.↗

Cerenkov light images of EAS produced by primary gamma

It is shown that it should be possible to distinguish very effectively between background hadronic showers and TeV gamma ray showers from a point source on the basis of the width, length and orientation of the Cerenkov light images of the shower, seen in the focal plane of a focusing mirror, even with a relatively coarse pixel size such as employed in the Mt. Hopkins detector. Predictions of the response of this system to air showers are presented.

Hillas, A. M.↗

Gamma-hadron families and scaling violation

For three different interaction models we have simulated gamma-hadron families, including the detector (Pamir emulsion chamber) response. Rates of gamma families, hadrons, and hadron-gamma ratios were compared with experiments.

Gaisser, T. K.↗

Extrapolation of Earth-based solar irradiance measurements to exoatmospheric levels for broad-band and selected absorption-band observations

Techniques for extrapolating Earth-based spectral band measurements of directly transmitted solar irradiance to equivalent exoatmospheric signal levels were used to aid in determining system gain settings of the Halogen Occultation Experiment (HALOE) sunsensor system being developed for the NASA Upper Atmosphere Research Satellite and for the Stratospheric Aerosol and Gas (SAGE) 2 instrument on the Earth Radiation Budget Satellite. A band transmittance approach was employed for the HALOE sunsensor which has a broad-band channel determined by the spectral responsivity of a silicon detector. A modified Langley plot approach, assuming a square-root law behavior for the water vapor transmittance, was used for the SAGE-2 940 nm water vapor channel.

Reagan, J. A.↗

A cavity radiometer for Earth albedo measurement, phase 1

Radiometric measurements of the directional albedo of the Earth requires a detector with a flat response from 0.2 to 50 microns, a response time of about 2 seconds, a sensitivity of the order of 0.02 mw/sq cm, and a measurement uncertainty of less than 5 percent. Absolute cavity radiometers easily meet the spectral response and accuracy requirements for Earth albedo measurements, but the radiometers available today lack the necessary sensitivity and response time. The specific innovations addressed were the development of a very low thermal mass cavity and printed/deposited thermocouple sensing elements which were incorporated into the radiometer design to produce a sensitive, fast response, absolute radiometer. The cavity is applicable to the measurement of the reflected and radiated fluxes from the Earth surface and lower atmosphere from low Earth orbit satellites. The effort consisted of requirements and thermal analysis; design, construction, and test of prototype elements of the black cavity and sensor elements to show proof-of-concept. The results obtained indicate that a black body cavity sensor that has inherently a flat response from 0.2 to 50 microns can be produced which has a sensitivity of at least 0.02 mw/sq cm per micro volt ouput and with a time constant of less than two seconds. Additional work is required to develop the required thermopile.

Source record↗

Techniques for fire detection

An overview is given of the basis for an analysis of combustable materials and potential ignition sources in a spacecraft. First, the burning process is discussed in terms of the production of the fire signatures normally associated with detection devices. These include convected and radiated thermal energy, particulates, and gases. Second, the transport processes associated with the movement of these from the fire to the detector, along with the important phenomena which cause the level of these signatures to be reduced, are described. Third, the operating characteristics of the individual types of detectors which influence their response to signals, are presented. Finally, vulnerability analysis using predictive fire modeling techniques is discussed as a means to establish the necessary response of the detection system to provide the level of protection required in the application.

Bukowski, Richard W.↗

Extrapolation of earth-based solar irradiance measurements to exoatmospheric levels for broad-band and selected absorption-band observations

Techniques for extrapolating earth-based spectral band measurements of directly transmitted solar irradiance to equivalent exoatmospheric signal levels were used to aid in determining system gain settings of the Halogen Occultation Experiment (HALOE) sunsensor being developed for the NASA Upper Atmosphere Research Satellite and for the Stratospheric Aerosol and Gas (SAGE) 2 instrument on the Earth Radiation Budget Satellite. A band transmittance approach was employed for the HALOE sunsensor which has a broad-band channel determined by the spectral responsivity of a silicon detector. A modified Langley plot approach, assuming a square-root law behavior for the water vapor transmittance, was used for the SAGE-2 940 nm water vapor channel.

Reagan, John A.↗

Image reconstruction of IRAS survey scans

The IRAS survey data can be used successfully to produce images of extended objects. The major difficulties, viz. non-uniform sampling, different response functions for each detector, and varying signal-to-noise levels for each detector for each scan, were resolved. The results of three different image construction techniques are compared: co-addition, constrained least squares, and maximum entropy. The maximum entropy result is superior. An image of the galaxy M51 with an average spatial resolution of 45 arc seconds is presented, using 60 micron survey data. This exceeds the telescope diffraction limit of 1 minute of arc, at this wavelength. Data fusion is a proposed method for combining data from different instruments, with different spacial resolutions, at different wavelengths. Data estimates of the physical parameters, temperature, density and composition, can be made from the data without prior image (re-)construction. An increase in the accuracy of these parameters is expected as the result of this more systematic approach.

Bontekoe, Tj. Romke↗