Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

CsPbBr3 perovskite single crystals for X- and -radiation detectors

Methods were developed for the synthesis and growth of halide lead perovskites CsPbBr3, which can be used as detectors of optical, X-ray, and -radiation. The growth of single crystals was carried out by the Bridgman method in quartz ampoules using zone-refined starting material. The electro-physical properties of the inorganic perovskite lead cesium tribromide CsPbBr3 were studied. Two types of structures with Cr/CsPbBr3/Ni rectifying and Ni/CsPbBr3/Ni ohmic contacts were fabricated. The resistivity of (  7×109 Ohmcm), and the activation energy of the dark conductivity (E  0.8 eV) were determined. From the measurements of the optical transmission spectra, the CsPbBr3 energy gap at 300 K was found to be Еg = 2.27 eV. The temperature dependence of the forbidden gap (Eg(T) = 2.4 - 4*10-4 T, eV) was also determined. A significant increase in photosensitivity for the Cr/CsPbBr3/Ni structure was observed at elevated temperatures. The Cr/CsPbBr3/Ni structures were shown to be sensitive to -radiation. The FWHM of the energy resolution for 241Am source was measured to be 15.8 keV.

Sklyarchuk, V.↗

AFIP-7 Tomography – 2013 Status Report

This project seeks to assess the geometric stability of the U-Mo monolithic fuel system by evaluating the radiation-induced changes in the AFIP-7 experiment device. Neutron radiography and computed tomography (CT) provide valuable information about the post-irradiation condition of the fuel specimen. Tomographic reconstructions of the AFIP-7 fuel element will be analyzed to assess the geometric condition of the element after irradiation and provide information regarding the condition of the fuel, including gross geometric defects, bowing, twist, plate buckling, cracks, and other defects. The INL, in collaboration with Oregon State University (OSU), Missouri University of Science and Technology (Missouri S&T), and Real Time Tomography, is developing advanced neutron detector systems and tomographic reconstruction techniques to evaluate the AFIP-7 fuel element. Neutron computed tomography using the current neutron radiography technique available at the Neutron Radiography reactor (NRAD) is impractical due to the long time and high cost to produce a set of images for tomographic reconstruction. Advanced neutron radiography systems such as the micro-channel plate (MCP) detector and neutron computed radiography (CR) may reduce the time and cost of acquiring images for neutron CT. The MCP detector system tested at OSU and Missouri S&T provides neutron radiographs and has lower gamma sensitivity compared to other digital acquisition image systems. However, some significant, but not prohibitive, challenges must be overcome to make its use for imaging nuclear fuel more practical. Images taken with the MCP require significant image processing to reduce distortions and correct for the dynamic detector response. Also, the small active area of the detector (~30 mm diameter) requires the collection and combination of several images of a specimen, which may become time-consuming. The MCP is tested in low gamma dose environments, but should also be tested in the gamma field at the INL. In addition to the MCP detector system, the INL is developing neutron computed radiography (CR), which uses the same foil transfer method currently employed at the NRAD, but replaces the film with a photostimulable storage phosphor imaging plate that is sensitive to the decay radiation from the activated transfer foils. Preliminary tests show that neutron CR provides lower, but comparable spatial resolution properties to film radiography images using the transfer method technique already employed at the NRAD. However, there are many factors that affect the spatial resolution of neutron CR that can be adjusted and possibly provide spatial resolution properties that exceed film radiography. The reduction in cost of neutron CR may be significant, which would make neutron imaging more appealing to programs that would benefit from this rare and valuable capability. Because transfer method neutron radiography is expensive and time-consuming, acquisition of a full set of radiographs for tomographic reconstruction is impractical. The INL is developing tomographic reconstruction techniques that require only a small set of radiographs of the AFIP-7 fuel element. These tomosynthesis techniques are tested using archived radiographs of TREAT experiments for CT as a proof of principle. These same techniques are applied to radiographs taken with an MCP detector of a mock-up of the AFIP-7 geometry. Acquisition angle should at least match the curvature of AFIP-7 plates. Lateral (in-plane) reconstruction resolution will be best when the projection angles include views at or near the desired reconstruction view angles. The ends of the fuel plates are angled at ±17.7° relative to the center of the plate. Increasing the number of projections is desirable, but given the constraint of minimizing the number of projections, the projection acquisition angle should also span at least ±17.7° to optimize the lateral resolution of the angled reconstruction planes used to visualize the gaps at the ends of the fuel plates. If possible, enough projections should be used within the initial acquisition angle of 35.4° (±17.7°) to bring the projection angular sampling closer to 1°. Further testing will determine a more specific recommendation for the number and angular distribution of neutron radiographs that will produce the highest quality tomographic reconstruction of the AFIP-7 fuel element.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Elemental X-ray Imaging Using the Maia Detector Array: The Benefits and Challenges of Large Solid-Angle

The fundamental parameter method for quantitative SXRF and PIXE analysis and imaging using the dynamic analysis method is extended to model the changing X-ray yields and detector sensitivity with angle across large detector arrays. The method is implemented in the GeoPIXE software and applied to cope with the large solid-angle of the new Maia 384 detector array and its 96 detector prototype developed by CSIRO and BNL for SXRF imaging applications at the Australian and NSLS synchrotrons. Peak-to-background is controlled by mitigating charge-sharing between detectors through careful optimization of a patterned molybdenum absorber mask. A geological application demonstrates the capability of the method to produce high definition elemental images up to {approx}100 M pixels in size.

43 PARTICLE ACCELERATORS↗

CALDER: Cryogenic light detectors for background-free searches

The development of background-free detectors is essential for experiments searching for rare events. Bolometers, that are among the most competitive devices for the study of neutrino-less double beta decay (0νDBD) and Dark Matter interactions, suffer from the absence of techniques that allow to identify the nature of the interacting particles. This limit can be overcome by coupling the bolometer to an independent device for the measurement of the light emitted by interactions, as the combined read-out of the bolometric and light signals allows to identify and reject particles different from those of interest. CUORE, the most advanced bolometric experiment for 0νDBD searches, could disentangle the electrons produced by 0νDBD from the dangerous background due to α particles, by measuring the (tiny) Cherenkov light emitted by electrons and not by α’s. LUCIFER, a project based on ZnSe scintillating bolometers for the study of {sup 82}Se 0νDBD, would be competitive also in the search of Dark Matter interactions if equipped with light detectors that allow to distinguish and reject the background due to electrons and γ’s. These advances require cryogenic detectors characterized by noise lower than 20 eV, large active area, wide temperature range of operation, high radio-purity and ease in fabricating hundreds of channels. The CALDER collaboration aims to develop such detectors by exploiting the superb energy resolution and natural multiplexed read-out provided by Kinetic Inductance Detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A position and pulse shape discriminant p -terphenyl detector module

We present the development of a neutron detector array module made with para-terphenyl, a bright, fast, n/γ discriminating crystalline organic scintillator. The module is comprised of 2 cm × 2 cm × 2 cm p-terphenyl crystals that have been optically coupled together to create a pseudo-bar module. While only relying on two photo detectors, the module is capable of distinguishing interactions between up to eight crystals. Furthermore, the module retains the p-terphenyl’s pulse shape discrimination (PSD) capability. Together this makes the pseudo-bar module a promising position-sensitive neutron detector. Here we present characteristics of the pseudo-bar module - its timing resolution as well as its pulse shape and position discrimination capabilities, and briefly discuss future plans for utilizing an array of pseudo-bar modules in a useful neutron detector system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectrum Unfolding with the MC-15

The Multiplicity Counter 15 tube detector or MC-15 is an optimized detector designed for use in the field. It is composed of 15 3 He tubes embedded in high density polyethylene (HDPE). Recent work has explored expanding the use of the MC-15 beyond multiplicity counting to neutron dosimetry applications. Knowledge of the neutron energy spectrum information is required to use a detector as a neutron dosimeter. The MC-15 tube layout is shown in Figure 1. The unique layout makes it possible to use the detector for neutron spectroscopy via spectrum unfolding. Spectrum unfolding requires (1) energy dependence of the detector response, (2) a detector response matrix that precisely quantifies the response to mono-energetic neutrons, (3) an initial guess spectrum, (4) an unfolding algorithm, and (5) measured data (counts in the case of the MC-15). An energy dependent detector response matrix (DRM) can be constructed by considering either each of the three rows of 3 He tubes as a distinct detector or each individual tube as a distinct detector. The HDPE separating the 3 He in the MC-15 provides the distinct energy dependent response for the rows and individual tubes. In this report we detail the development of detector response matrices for the MC-15 and the application of the Los Alamos Unfolding Code (LUC) to both simulated and measured data. Three MC-15 orientations were studied: (1) standard orientation with the MC-15 front facing the source, (2) standard orientation with Cd sheet, (3) 90° orientation with the side of the MC-15 facing the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid Cherenkov detector for studying nucleosynthesis in inertial confinement fusion

Measuring gamma rays emitted from nuclear reactions gives insight into their nuclear structure. Notably, there are several nuclear reactions that produce gamma rays at ~1 MeV–3 MeV energies such as T( 4 He, γ) 7 Li, 4 He( 3 He, γ) 7 Be, and 12 C(p, γ) 13 N, which may solve questions lingering about big-bang nucleosynthesis and stellar nucleosynthesis. To observe 1 MeV–3 MeV gamma rays in an inertial confinement fusion system, a new style of the Cherenkov detector was developed using aerogel and fused silica as a Cherenkov medium. Utilizing the OMEGA laser facility, both aerogel and fused silica media were compared with the existing gas-medium Cherenkov detector to validate the concept. Furthermore, gamma ray measurements from high yield inertial confinement fusion implosions (deuterium–tritium and deuterium– 3 He) demonstrated that aerogel and fused silica were viable Cherenkov media, paving the way for a potential optimized detector to make these cross section measurements on OMEGA or the National Ignition Facility.

47 OTHER INSTRUMENTATION↗

Scintillation light detection in polycrystalline diamond using single photon detectors

Here, this study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to monocrystalline diamonds while retaining essential detection properties. Photoluminescence measurements were performed to analyze emission spectra, revealing distinct characteristics based on impurity content and crystallinity. Scintillation responses were assessed using Silicon Photomultipliers (SiPMs), demonstrating the capability of polycrystalline diamond powders to respond to alpha irradiation, albeit with reduced resolution compared to traditional scintillators. A prototype neutron detector was developed by combining diamond powder with neutron-sensitive 6 LiF, and its performance was evaluated through experimental testing and Geant4 simulations. The findings indicate that polycrystalline diamond-based detectors can achieve significant detection efficiency while remaining insensitive to gamma radiation, offering potential for portable neutron detection applications.

47 OTHER INSTRUMENTATION↗

Simulation of image detectors in radiology for determination of scatter-to-primary ratios using Monte Carlo radiation transport code MCNP/MCNPX

Purpose: The purpose of this study was to compare and validate three methods to simulate radiographic image detectors with the Monte Carlo software MCNP/MCNPX in a time efficient way. Methods: The first detector model was the standard semideterministic radiography tally, which has been used in previous image simulation studies. Next to the radiography tally two alternative stochastic detector models were developed: A perfect energy integrating detector and a detector based on the energy absorbed in the detector material. Validation of three image detector models was performed by comparing calculated scatter-to-primary ratios (SPRs) with the published and experimentally acquired SPR values. Results: For mammographic applications, SPRs computed with the radiography tally were up to 44% larger than the published results, while the SPRs computed with the perfect energy integrating detectors and the blur-free absorbed energy detector model were, on the average, 0.3% (ranging from -3% to 3%) and 0.4% (ranging from -5% to 5%) lower, respectively. For general radiography applications, the radiography tally overestimated the measured SPR by as much as 46%. The SPRs calculated with the perfect energy integrating detectors were, on the average, 4.7% (ranging from -5.3% to -4%) lower than the measured SPRs, whereas for the blur-free absorbed energy detector model, the calculated SPRs were, on the average, 1.3% (ranging from -0.1% to 2.4%) larger than the measured SPRs. Conclusions: For mammographic applications, both the perfect energy integrating detector model and the blur-free energy absorbing detector model can be used to simulate image detectors, whereas for conventional x-ray imaging using higher energies, the blur-free energy absorbing detector model is the most appropriate image detector model. The radiography tally overestimates the scattered part and should therefore not be used to simulate radiographic image detectors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity Frontier Computing at Fermilab

The Intensity Frontier (IF) experiments at Fermilab require computing, software, data handling, and infrastructure development for detector and beamline design and to extract maximum scientific output from the data. The emphasis of computing at Fermilab for many years has been on the Tevatron collider Run 2 experiments and CMS. Using the knowledge and experience gained from those experiments as well as new computing developments, preparations for computing for IF experiments are ramping up. There are many challenges in IF computing. These include event generators and detector simulation, beamline simulation, detector design and optimization, data acquisition, data handling, data analysis, and all of the associated services required. In this presentation the computing challenges and requirements will be described and the approaches being taken to address them will be shown.

43 PARTICLE ACCELERATORS↗

The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment

Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ( 0νββ ) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here, we report the detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for 0νββ decay with mK-scale calorimeters, and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE’s energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to 0νββ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.

experimental nuclear physics↗

Development and performance evaluation of an experimental fine pitch detector multislice CT scanner

The authors have developed an experimental fine pitch detector multislice CT scanner with an ultrasmall focal spot x-ray tube and a high-density matrix detector through current CT technology. The latitudinal size of the x-ray tube focal spot was 0.4 mm. The detector dimension was 1824 channels (azimuthal direction)x32 rows (longitudinal direction) at row width of 0.3125 mm, in which a thinner reflected separator surrounds each detector cell coupled with a large active area photodiode. They were mounted on a commercial 64-slice CT scanner gantry while the scan field of view (50 cm) and gantry rotation speed (0.35 s) can be maintained. The experimental CT scanner demonstrated the spatial resolution of 0.21-0.22 mm (23.8-22.7 lp/cm) with the acrylic slit phantom and in-plane 50%-MTF 9.0 lp/cm and 10%-MTF 22.0 lp/cm. In the longitudinal direction, it demonstrated the spatial resolution of 0.24 mm with the high-resolution insert of the CATPHAN phantom and 0.34 mm as the full width at half maximum of the slice sensitivity profile. In low-contrast detectability, 3 mm at 0.3% was visualized at the CTDI{sub vol} of 47.2 mGy. Two types of 2.75 mm diameter vessel phantoms with in-stent stenosis at 25%, 50%, and 75% stair steps were scanned, and the reconstructed images can clearly resolve the stenosis at each case. The experimental CT scanner provides high-resolution imaging while maintaining low-contrast detectability, demonstrating the potentiality for clinical applications demanding high spatial resolution, such as imaging of inner ear, lung, and bone, or low-contrast detectability, such as imaging of coronary artery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phenomenological Model for Predicting the Energy Resolution of Neutron-Damaged Coaxial HPGe Detectors

The peak energy resolution of germanium detectors deteriorates with increasing neutron fluence. This is due to hole capture at neutron-created defects in the crystal which prevents the full energy of the gamma-ray from being recorded by the detector. A phenomenological model of coaxial HPGe detectors is developed that relies on a single, dimensionless parameter that is related to the probability for immediate trapping of a mobile hole in the damaged crystal. As this trap parameter is independent of detector dimensions and type, the model is useful for predicting energy resolution as a function of neutron fluence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid-state image converters on the basis of the GaAs/ZnS structures

Emission-voltage characteristics and frequency dependences of the luminescence intensity of electroluminescent capacitors on the basis of the ZnS:(Cu,Al) phosphor are studied. The effect of X-ray radiation (17 keV) on the high-resistivity GaAs layers obtained by three methods is studied. The possibility to develop the detectors of the ionizing radiation with optical reading of information with the use of the GaAs/ZnS structures is shown using a mathematical simulation. It is noted that the most promising material for the development of the solid-state image converters is GaAs:Cr obtained by diffusion of Cr from the deposited layer.

36 MATERIALS SCIENCE↗

Hard x-ray response of pixellated CdZnTe detectors

In recent years, the development of cadmium zinc telluride (CdZnTe) detectors for x-ray and gamma ray spectrometry has grown rapidly. The good room temperature performance and the high spatial resolution of pixellated CdZnTe detectors make them very attractive in space-borne x-ray astronomy, mainly as focal plane detectors for the new generation of hard x-ray focusing telescopes. In this work, we investigated on the spectroscopic performance of two pixellated CdZnTe detectors coupled with a custom low noise and low power readout application specific integrated circuit (ASIC). The detectors (10x10x1 and 10x10x2 mm{sup 3} single crystals) have an anode layout based on an array of 256 pixels with a geometric pitch of 0.5 mm. The ASIC, fabricated in 0.8 mum BiCMOS technology, is equipped with eight independent channels (preamplifier and shaper) and characterized by low power consumption (0.5 mW/channel) and low noise (150-500 electrons rms). The spectroscopic results point out the good energy resolution of both detectors at room temperature [5.8% full width at half maximum (FWHM) at 59.5 keV for the 1 mm thick detector; 5.5% FWHM at 59.5 keV for the 2 mm thick detector) and low tailing in the measured spectra, confirming the single charge carrier sensing properties of the CdZnTe detectors equipped with a pixellated anode layout. Temperature measurements show optimum performance of the system (detector and electronics) at T=10 deg.C and performance degradation at lower temperatures. The detectors and the ASIC were developed by our collaboration as two small focal plane detector prototypes for hard x-ray multilayer telescopes operating in the 20-70 keV energy range.

36 MATERIALS SCIENCE↗

On the Matter of Dark Matter

The mission of the USS Enterprise was to “boldly go where no one has gone before.” And so it is with Particle Physicist John Orrell as he seeks to solve the conundrum of elusive dark matter. It’s a mystery that PNNL scientists have chased for more than 25 years. And, if dark matter is discovered, it will change our entire understanding of how the universe was formed. The first experiments to locate dark matter were conducted underground using specialized, radiation detector technology developed at PNNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Materials for Gamma Radiation Sensors

Sensors used for spectroscopic measurements of gamma radiation are most often scintillator or semiconductor materials. An overview is provided in this chapter on the materials and development techniques used in producing spectroscopic gamma radiation sensors. Challenges that prevent a perfect sensor are discussed along with the reasons why some sensor materials are ubiquitous despite their performance limitations. The types of sensors commonly used as detectors are discussed along with their key physical properties and electronic characteristics. Materials commonly utilized in radiation detectors are then reviewed to highlight how sensor materials have advanced since the earliest gamma detectors were developed

Johns, Paul M.↗