Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “demand potential”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Near-Surface Plasma Characterization of the 12.5-kW NASA TDU1 Hall Thruster

To advance the state-of-the-art in Hall thruster technology, NASA is developing a 12.5-kW, high-specific-impulse, high-throughput thruster for the Solar Electric Propulsion Technology Demonstration Mission. In order to meet the demanding lifetime requirements of potential missions such as the Asteroid Redirect Robotic Mission, magnetic shielding was incorporated into the thruster design. Two units of the resulting thruster, called the Hall Effect Rocket with Magnetic Shielding (HERMeS), were fabricated and are presently being characterized. The first of these units, designated the Technology Development Unit 1 (TDU1), has undergone extensive performance and thermal characterization at NASA Glenn Research Center. A preliminary lifetime assessment was conducted by characterizing the degree of magnetic shielding within the thruster. This characterization was accomplished by placing eight flush-mounted Langmuir probes within each discharge channel wall and measuring the local plasma potential and electron temperature at various axial locations. Measured properties indicate a high degree of magnetic shielding across the throttle table, with plasma potential variations along each channel wall being less than or equal to 5 eV and electron temperatures being maintained at less than or equal to 5 eV, even at 800 V discharge voltage near the thruster exit plane. These properties indicate that ion impact energies within the HERMeS will not exceed 26 eV, which is below the expected sputtering threshold energy for boron nitride. Parametric studies that varied the facility backpressure and magnetic field strength at 300 V, 9.4 kW, illustrate that the plasma potential and electron temperature are insensitive to these parameters, with shielding being maintained at facility pressures 3X higher and magnetic field strengths 2.5X higher than nominal conditions. Overall, the preliminary lifetime assessment indicates a high degree of shielding within the HERMeS TDU1, effectively mitigating discharge channel erosion as a life-limiting mechanism.

Lifetime↗

Seismic Assessment of a Long-Term Lunar Habitat

The establishment of secure earth-independent long-term lunar habitats has been envisioned by numerous government agencies and private companies. Recent advancements in assessing seismic hazards caused by shallow moonquakes have highlighted the importance of incorporating this phenomenon into the design of robust and resilient lunar structures. However, further research is required to explore lunar habitat design that considers seismic loads. This paper proposes assessing the structural response of a lunar habitat made of sulfur concrete covered with a regolith layer. The numerical model of the structure is subjected to gravitational, internal pressure and seismic loads. The seismic analysis of the structure is carried out using spectral and nonlinear time history methods. Conditional mean spectra for shallow moonquakes with return periods of 75, 475, 970 and 2475 years are used in the seismic analysis. The records used for the temporal analyses were ground motions that agree with a preliminary seismic hazard on the Moon. The results of temporal analyses reveal that shallow moonquakes with return periods greater than 475 years can lead to the loss of the global stability of the structure. Consequently, the findings imply that seismic loads have the potential to impose unacceptable demands on lunar structures constructed from in-situ materials like sulfur concrete. Hence, it is imperative to incorporate seismic considerations in the design process for developing resilient and long-term lunar habitats.

Lunar habitat↗

Parallel Hybrid Turboprop Performance Modeling and Optimization

NASA’s Electrified Powertrain Flight Demonstration (EPFD) project conducts ground and flight tests of integrated Megawatt (MW) class hybrid-electric powertrain systems on regional turboprop aircraft demonstrators. To meet the increased demand for assessment of potential capabilities and benefits from these novel vehicle configurations, NASA is developing tooling and models to estimate the performance of hybridized regional turboprops. This paper covers the development of a parametrically driven performance model for a De Havilland Canada Dash 8-400 (Q400) regional turboprop integrated with a novel parallel hybrid architecture using the Gascon framework. Gascon is a modern reimplementation of the General Aviation Synthesis Program (GASP) built using the Condor mathematical modeling framework in Python. Within Gascon, a parametric representation of the parallel hybrid architecture was synthesized, which features the electric motor coupled to the power turbine. This capability allows for in-the-loop optimization of the parametric parallel hybrid architecture to characterize the mission capabilities and fuel savings of the design and determine optimal power scheduling strategies for efficient electric power management for a given mission. The study shows that a fuel savings of up to 20% can be achieved, but that increased fuel savings comes at the expense of payload capacity.

Gascon↗

Parallel Hybrid Turboprop Performance Modeling and Optimization

NASA’s Electrified Powertrain Flight Demonstration (EPFD) project conducts ground and flight tests of integrated Megawatt (MW) class hybrid-electric powertrain systems on regional turboprop aircraft demonstrators. To meet the increased demand for assessment of potential capabilities and benefits from these novel vehicle configurations, NASA is developing tooling and models to estimate the performance of hybridized regional turboprops. This paper covers the development of a parametrically driven performance model for a De Havilland Canada Dash 8-400 (Q400) regional turboprop integrated with a novel parallel hybrid architecture using the Gascon framework. Gascon is a modern reimplementation of the General Aviation Synthesis Program (GASP) built using the Condor mathematical modeling framework in Python. Within Gascon, a parametric representation of the parallel hybrid architecture was synthesized, which features the electric motor coupled to the power turbine. This capability allows for in-the-loop optimization of the parametric parallel hybrid architecture to characterize the mission capabilities and fuel savings of the design and determine optimal power scheduling strategies for efficient electric power management for a given mission. The study shows that a fuel savings of up to 20% can be achieved, but that increased fuel savings comes at the expense of payload capacity.

Gascon↗

California Statewide PEV Infrastructure Assessment; NREL (National Renewable Energy Laboratory)

This presentation discusses how the California Statewide Plug-In Electric Vehicle (PEV) Infrastructure Assessment provides a framework for understanding the potential energy (kWh) and demand (MW) impacts of PEV market growth; how PEV travel simulations can inform the role of public infrastructure in future market growth; and how ongoing assessment updates and Alternative Fuels Data Center outreach can help coordinate stakeholder planning and decision making and reduce uncertainties.

33 ADVANCED PROPULSION SYSTEMS↗

Feasibility of Development of Geothermal Deep Direct-Use District Heating and Cooling system at West Virginia University Campus-Morgantown, WV

The Morgantown campus of West Virginia University (WVU) is uniquely positioned to host the first geothermal deep direct-use district heating and cooling (GDHC) system in the eastern United States. While much of the eastern United States does not have elevated heat flow, the Morgantown region of West Virginia is unique in exhibiting sufficient temperatures at the depth of a formation, the Tuscarora, which is expected to support a desirable flow rate of geofluid. Temperature and flow rate were identified in the 2006 MIT Future of Geothermal Energy Report to be the two most critical factors in minimizing the cost of geothermal energy. The WVU campus site offers surface demand coupled with the potential subsurface viability. Specifically, the existing district heating and cooling system that is in use year round will be leveraged. Absorption chilling systems are used to cool the campus in the summer and provide hot water circulating heat in the winter. Our overall project objectives are to 1) collect local information on these critical factors to understand the uncertainty and reduce the risk associated with developing the geothermal resource for use in a WVU campus GDHC system, and 2) complete an optimized design for the GDHC system by minimizing the delivered Levelized Cost of Heat (LCOH). A Tuscarora geological model was built based on core analysis and permeability measurements using data from nearby wells. This geological model is then translated into a reservoir model. iTOUGH2/EOS1 is used to simulate the subsurface portion of a GDHC system using two well configurations: 1) a pair of vertical wells, and 2) a pair of horizontal wells. The performance of both configurations is evaluated based on achievable flow rates and production fluid temperatures; the recommended well configuration is selected based on the expected GDHC system performance. The thermal breakthrough and reservoir productivity increased for horizontal well configuration however, the well-head LCOH for vertical well horizontal well configuration is higher than vertical wells due to the additional cost of horizontal drilling. To minimize the delivered LCOH, we perform an integrated surface-to-subsurface optimization of the full GDHC system. The economic and performance analysis of the GDHC system is evaluated for two cases: 1) using existing district heating and cooling facilities, and 2) by converting the current WVU campus steam infrastructure to a hot water system. The optimized GDHC system will be selected by minimizing the LCOH over these two possible configurations.

15 GEOTHERMAL ENERGY↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Demographic Information Incorporated Household Energy Consumption Analysis: Preprint

The high energy consumption from residential buildings provides them large potential to participate in demand response programs. To design appropriate demand response programs for residential buildings, it is important for electric utilities to know the energy consumption characteristics for different types of households so that utilities can send requests to the groups with a higher possibility to successfully respond. In this paper, we develop a load model to generate synthetic load profiles for different types of households incorporating demographical information including Current Population Survey data set and American Time Use Survey data set. The details of each data set and the details of the load models are presented. The synthetic household load profiles are generated by the load model and clustered into different groups based on state, age, number of occupants, income level, and city of the household. The average energy consumption characteristics for different groups of households are analyzed and compared, which will help electric utilities issue demand response signals to appropriate households.

building loads↗

Demographic Information Incorporated Household Energy Consumption Analysis

The high energy consumption from residential buildings provides them large potential to participate in demand response programs. To design appropriate demand response programs for residential buildings, it is important for electric utilities to know the energy consumption characteristics for different types of households so that utilities can send requests to the groups with a higher possibility to successfully respond. In this paper, we develop a load model to generate synthetic load profiles for different types of households incorporating demographical information including Current Population Survey data set and American Time Use Survey data set. The details of each data set and the details of the load models are presented. The synthetic household load profiles are generated by the load model and clustered into different groups based on state, age, number of occupants, income level, and city of the household. The average energy consumption characteristics for different groups of households are analyzed and compared, which will help electric utilities issue demand response signals to appropriate households.

building loads↗

Characterizing the Benefits of Seismic Isolation of Nuclear Structures in Terms of Reduced Risk and Cost

Seismic isolation is a mature technology that has been implemented in many civil structures, including buildings, bridges, liquid natural gas tanks, and off shore oil platforms, both in the United States and other countries, to mitigate the damaging effects of earthquakes. Seismic isolation has also been used in nuclear structures in France and South Africa, but not yet in the United States: neither in the Department of Energy facilities nor in commercial nuclear power plants (NPPs). This is primarily due to a lack of guidelines, codes and standards for the analysis, design and construction specific to seismically isolated nuclear structures. However, seismic isolation of nuclear structures has seen increased research interest in the recent years and the recently published national consensus standard, America Society of Civil Engineers (ASCE) Standard 4-16 'Seismic analysis of safety related nuclear structures', now incorporates language and commentary (Chapter 12) for seismically isolating surface or near-surface-mounted nuclear facilities, including NPPs. Seismic isolation substantially reduces horizontal seismic loads (demands) on structures, systems, and components. Reduction in demand results in four potential benefits: (1) economic: reduction in capital cost, (2) increased safety: reduction in the mean annual frequency of unacceptable performance, (3) insurance: protection against increases in the known seismic hazard after construction by minimizing the effort to re-qualify and re-certify structures, systems and components, and (4) recertification: the opportunity to certify an existing NPP design for a region of higher seismic hazard. Item (2) above, an increase in safety (reduction of seismic risk), was explored in Huang et al., wherein it was demonstrated that the implementation of seismic isolation reduced seismic risk in nuclear power plant structures. Studies that assess item (1) have not been performed although the use of isolation may lead to large reductions in the capital cost of safety-related nuclear facilities. Funding provided by Nuclear Safety Research and Development in the Department of Energy (DOE) allowed the authors to develop a framework for assessing the economic benefits and reductions in seismic risk afforded by the use of seismic (base) isolation. The framework includes probabilistic risk assessment and estimation of overnight capital costs (OCC's) of a sample generic DOE nuclear facility (GDNF). The project is documented in detail in Bolisetti et al. and Yu et al., and key results are presented here. The GDNF considered in this study is based on a facility constructed at the Idaho National Laboratory. The GDNF is a two-story reinforced concrete building with an embedded basemat and is founded on soft rock at the boundary of Site Class B and Site Class C (B/C boundary) as characterized by ASCE/SEI Standard 7. The GDNF is assumed to handle radiological materials, and its structure, systems and components (SSC's) are designed to effectively confine these materials in the event of an internal failure. The GDNF is populated with components that are generic to safety-related nuclear structures. A single system, which is intended to confine a loss of materials-at-risk (MAR) to the interior of the structure, is chosen for this study. Accordingly, a hypothetical event tree and fault tree are assumed for risk assessment. The isolation system for the GDNF is designed per Chapter 12 of ASCE/SEI 4-16 but is not optimized. The isolation system consists of 38 lead rubber bearings installed in one horizontal plane below the basemat. Details of the GDNF, including the SSC's, event tree and fault tree, and isolation system, are presented in the project report and Yu et al.. This study includes seismic risk assessment and cost estimation for four cases: (1) the GDNF is located at a site of low to moderate seismic hazard and is constructed on a conventional (non-isolated) foundation; (2) the GDNF is located at the same site as case 1, but is seismically isolated; (3) the GDNF is located at a site of high seismic hazard and is constructed on a conventional foundation; and (4) the GDNF is located at the same site of high seismic hazard as case 3, but is seismically isolated. In this study, the DOE site at Idaho National Laboratory (INL) is chosen as the low to moderate seismic hazard site for cases 1 and 2, and the Los Alamos National Laboratory (LANL) is chosen as the high seismic hazard site for cases 3 and 4.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

UZrCN Synthesis via Arc Melting - A Novel Synthesis Study

The next generation of nuclear reactors for both power production and space nuclear propulsion require fuel that is more durable, thermally stable, and more thermally conductive to support rapid heat transfer. High temperature gas reactors (HTGR), advanced gas reactors (AGR), and space-based nuclear thermal propulsion (NTP) are advanced reactor concepts that require a fuel type that can withstand high temperatures (1000-2900K) and flow of corrosive gas coolants such as helium, hydrogen, and carbon dioxide. One fuel with the potential to meet these demanding requirements is uranium-zirconium-carbonitride (UZrCN). UZrCN has many favorable fuel qualities compared to other eligible fuel forms such as uranium dioxide (UO2) and uranium mononitride (UN) that could support the aforementioned reactor concepts. UZrCN has an exceptionally high operating temperature and thermal conductivity which are highly desirable to improve reactor economics and safety. It far exceeds the properties of UO2 which is the most common fuel form in the United States. UZrCN also surpasses UN in terms of thermal conductivity and operating temperature by eliminating the dissociation problem UN has at 1700K. UZrCN could improve gas reactor performance and enable NTP technologies; however, it is an under-researched fuel that lacks rigorous scientific study. In recent efforts by the Idaho National Laboratory, a variety of novel methods to produce this fuel composition have been explored. One such method is via arc melting of uranium, zirconium, and carbon under a nitrogen atmosphere. Alloy fabrication using arc melting has been utilized for close to 150 years now and is well-understood as a method for rapid alloy prototyping. This process will be used to perform in-situ nitriding to form UZrCN.

36 MATERIALS SCIENCE↗

UZrCN Formation via Arc Melting – A Novel Synthesis Study

The next generation of nuclear reactors for both power production and space nuclear propulsion require fuel that is more durable, thermally stable, and more thermally conductive to support rapid heat transfer. High temperature gas reactors (HTGR), advanced gas reactors (AGR), and space-based nuclear thermal propulsion (NTP) are advanced reactor concepts that require a fuel type that can withstand high temperatures (1000-2900K) and flow of corrosive gas coolants such as helium, hydrogen, and carbon dioxide. One fuel with the potential to meet these demanding requirements is uranium-zirconium-carbonitride (UZrCN). UZrCN has many favorable fuel qualities compared to other eligible fuel forms such as uranium dioxide (UO2) and uranium mononitride (UN) that could support the aforementioned reactor concepts. UZrCN has an exceptionally high operating temperature and thermal conductivity which are highly desirable to improve reactor economics and safety. It far exceeds the properties of UO2 which is the most common fuel form in the United States. UZrCN also surpasses UN in terms of thermal conductivity and operating temperature by eliminating the dissociation problem UN has at 1700K. UZrCN could improve gas reactor performance and enable NTP technologies; however, it is an under-researched fuel that lacks rigorous scientific study. In recent efforts by the Idaho National Laboratory, a variety of novel methods to produce this fuel composition have been explored. One such method is via arc melting of uranium, zirconium, and carbon under a nitrogen atmosphere. Alloy fabrication using arc melting has been utilized for close to 150 years now and is well-understood as a method for rapid alloy prototyping. This process will be used to perform in-situ nitriding to form UZrCN.

36 MATERIALS SCIENCE↗

Demand Response and Energy Storage Integration Study

Demand response and energy storage resources present potentially important sources of bulk power system services that can aid in integrating variable renewable generation. While renewable integration studies have evaluated many of the challenges associated with deploying large amounts of variable wind and solar generation technologies, integration analyses have not yet fully incorporated demand response and energy storage resources. This report represents an initial effort in analyzing the potential integration value of demand response and energy storage, focusing on the western United States. It evaluates two major aspects of increased deployment of demand response and energy storage: (1) Their operational value in providing bulk power system services and (2) Market and regulatory issues, including potential barriers to deployment.

25 ENERGY STORAGE↗

Optimization Framework to Assess the Demand Response Capacity of a Water Distribution System

As large electricity consumers, water distribution system (WDS) pumping stations have the potential to become meaningful participants in demand response (DR) programs. The authors propose an optimization framework for assessing the DR capacity of a WDS and identifying the optimal bidding strategy for maximizing WDS revenue in the DR spot market. The proposed mixed integer linear programming (MILP) model overcomes computational constraints of previous DR optimization models by adopting a preprocessing procedure to minimize the number of binary variables and implementing a convex relaxation technique to linearize the hydraulic equations. The proposed MILP model also explicitly accounts for varying levels of risk tolerance of WDS operators by varying the recovery period over which pumping returns to business-as-usual operation. The optimization framework is implemented on a skeletonized 48-node WDS model that includes 7 pumps, 6 tanks, and 39 pipes. Using a simulated DR event and water consumption profile, the authors derive the optimal DR supply curves (i.e., compensation price versus load curtailment quantity) and revenue potential of the WDS under six scenarios for DR participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hourly Load Profile Dataset for Electric Airport Ground Support Equipment in the United States

Currently, there are limited data on the magnitude and timing of electricity demand from electric ground support equipment (eGSE) across U.S. airports. To address this gap, this study presents a modeling approach for estimating hourly annual electricity demand from eGSE at the 50 largest U.S. commercial airports. These datasets, accessible at data.nrel.gov/submissions/279, provide critical insights into the potential grid impacts and electricity demand associated with eGSE adoption.

33 ADVANCED PROPULSION SYSTEMS↗