Characteristics of Cryogenic Hydrogen Releases Under Unignited and Ignited Conditions

Hydrogen is increasingly being used in the public sector as a fuel for vehicles. Due to the high density of hydrogen in its liquid phase, fueling stations that receive deliveries of and store hydrogen as a liquid are more practical for high volume stations. There is a critical need for validated models to assess the risk at hydrogen fueling stations with cryogenic hydrogen on-site. In this work, a cryogenic hydrogen release experiment generated controlled releases of cryogenic hydrogen in the laboratory. We measured the maximum ignition distance, flame length and the radiative heat flux and developed correlations to calculate the ignition ditance and the radiative heat flux. We also measured the concentration and temperature fields of releases under unignited conditions and used these measurements to validate a model for these cryogenic conditions. This study provides critical information on the development of models to inform the safety codes and standards of hydrogen infrastructure.

08 HYDROGEN↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vesse l relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overview and Status of the Long-Baseline Neutrino Facility Far Detectors Cryogenics System

The Sanford Underground Research Facility (SURF) will host the Far Detectors of the Deep Underground Neutrino Experiment (DUNE), an international multi-kiloton Long-Baseline neutrino experiment that will be installed about a mile underground in Lead, SD. Detectors will be located inside four cryostats filled with almost 70,000 metric tons of ultrapure liquid argon, with a level of impurities lower than 100 parts per trillion of oxygen equivalent. The cryogenics infrastructure supporting this experiment is provided by the Long- Baseline Neutrino Facility (LBNF). This contribution presents modes of operation, layout and main features of the LBNF Far Detectors cryogenics system, which is composed of the following subsystems: argon receiving facilities, nitrogen system, argon distribution system, argon purification and regeneration systems, argon circulation system, argon condensers system, internal cryogenics, miscellaneous items, and process controls. An international engin eering tea m is designing these systems and will manufacture, install, test, commission, and qualify them. This contribution describes the main features, performance, functional requirements, and modes of operation of the LBNF Far Detectors cryogenics system. It also presents the status of the design, along with present and future needs to support the DUNE experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Validation of a Cryogenic Dilatometer

This project focuses on the design and development of a cryogenic dilatometer capable of measuring the thermal expansion of materials at extremely low temperatures. Understanding how materials change dimension with temperature is critical for applications involving cryogenic environments, particularly laminated systems housing superconducting magnets, where small dimensional changes can significantly affect performance and reliability. To address this, a dilatometer system was designed to operate within a liquid nitrogen environment while accurately measuring displacements caused by thermal contraction. The purpose of this device is to determine the coefficient of thermal expansion (CTE) of a material. The design process involved defining functional requirements, developing mechanical and thermal concepts for the measurement apparatus, selecting appropriate materials compatible with cryogenic temperatures, and integrating sensors capable of detecting small dimensional changes. The resulting system aims to provide a practical and repeatable method for evaluating material thermal expansion at cryogenic temperatures, supporting research into composite use in superconducting applications that require accurate characterization of material behavior in low-temperature environments.

Schmitt, Nicholas [Northern Illinois U.]↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

FOS: Physical sciences↗

Carbon fiber composites for cryogenic filament-wound vessels

Advanced unidirectional and bidirectional carbon fiber/epoxy resin composites were evaluated for physical and mechanical properties over a cryogenic to room temperature range for potential application to cryogenic vessels. The results showed that Courtaulds HTS carbon fiber was the superior fiber in terms of cryogenic strength properties in epoxy composites. Of the resin systems tested in ring composites, CTBN/ERLB 4617 exhibited the highest composite strengths at cryogenic temperatures, but very low interlaminar shear strengths at room temperature. Tests of unidirectional and bidirectional composite bars showed that the Epon 828/Empol 1040 resin was better at all test temperatures. Neither fatigue cycling nor thermal shock had a significant effect on composite strengths or moduli. Thermal expansion measurements gave negative values in the fiber direction and positive values in the transverse direction of the composites.

Larsen, J. V.↗

Shuttle cryogenic supply system optimization study. Volume 5A-1: Users manual for math models

The Integrated Math Model for Cryogenic Systems is a flexible, broadly applicable systems parametric analysis tool. The program will effectively accommodate systems of considerable complexity involving large numbers of performance dependent variables such as are found in the individual and integrated cryogen systems. Basically, the program logic structure pursues an orderly progression path through any given system in much the same fashion as is employed for manual systems analysis. The system configuration schematic is converted to an alpha-numeric formatted configuration data table input starting with the cryogen consumer and identifying all components, such as lines, fittings, and valves, each in its proper order and ending with the cryogen supply source assembly. Then, for each of the constituent component assemblies, such as gas generators, turbo machinery, heat exchangers, and accumulators, the performance requirements are assembled in input data tabulations. Systems operating constraints and duty cycle definitions are further added as input data coded to the configuration operating sequence.

Source record↗

The Langley cryogenic high Reynolds number wind-tunnel program

A pilot version of a new type of transonic tunnel was placed in operation in the fall of 1973. In the tunnel the cryogenic method is used to obtain a high Reynolds number. The cryogenic concept employs low temperatures to increase the Reynolds number through reducing the viscous forces rather than increasing the inertia forces. The cryogenic approach offers the desired Reynolds-number increase with no increase in dynamic pressure, and therefore no increase in model loads. A series of aerodynamic experiments have been made in the pilot tunnel to confirm the cryogenic concept at transonic speeds. A brief description is given of the project for a large tunnel which has evolved from the investigations.

Polhamus, E. C.↗

Materials and construction techniques for cryogenic wind tunnel facilities for instruction/research use

The results of the cryogenic wind tunnel program conducted at NASA Langley Research Center are presented to provide a starting point for the design of an instructional/research wind tunnel facility. The advantages of the cryogenic concept are discussed, and operating envelopes for a representative facility are presented to indicate the range and mode of operation. Special attention is given to the design, construction and materials problems peculiar to cryogenic wind tunnels. The control system for operation of a cryogenic tunnel is considered, and a portion of a linearized mathematical model is developed for determining the tunnel dynamic characteristics.

Morse, S. F.↗

The cryogenic transonic wind tunnel for high Reynolds number research

Based on theoretical studies and experience with a low speed cryogenic tunnel and with the transonic cryogenic tunnel, the cryogenic wind tunnel concept has been shown to offer many advantages with respect to the attainment of full scale Reynolds number at reasonable levels of dynamic pressure in a ground based facility. The unique modes of operation available in a pressurized cryogenic tunnel make possible for the first time the separation of Mach number, Reynolds number, and aeroelastic effects.

Kilgore, R. A.↗

Cryogenic wind tunnels: Unique capabilities for the aerodynamicist

The cryogenic wind-tunnel concept as a practical means for improving ground simulation of transonic flight conditions. The Langley 1/3-meter transonic cryogenic tunnel is operational, and the design of a cryogenic National Transonic Facility is undertaken. A review of some of the unique capabilities of cryogenic wind tunnels is presented. In particular, the advantages of having independent control of tunnel Mach number, total pressure, and total temperature are highlighted. This separate control over the three tunnel parameters will open new frontiers in Mach number, Reynolds number, aeroelastic, and model-tunnel interaction studies.

Hall, R. M.↗

Experimental investigation to validate use of cryogenic temperatures to achieve high Reynolds numbers in boattail pressure testing

An investigation has been conducted in the Langley 1/3 meter transonic cryogenic tunnel to validate the use of cryogenic temperatures to achieve high Reynolds numbers in nozzle boattail pressure testing. Tests were conducted at 0 degree angle of attack and at Mach numbers of 0.60, 0.85, and 0.90 on two wing-body configurations with differing boattail geometries. Test data were obtained by using two different techniques, the cryogenic method and the conventional method, to obtain the same Reynolds number. Later, the test data obtained from the two techniques on boattail pressure coefficient distributions and pressure drag coefficients were compared; results from the comparisons show excellent repeatability for all test conditions and indicate no measurable errors when using cryogenic temperatures to achieve high Reynolds numbers for nozzle boattail pressure testing.

Reubush, D. E.↗

Cryogenics for spacecraft

It is pointed out that cryogenic engineering has been an integral part of space research almost from the beginning of the space age because of the significant performance advantages available from cryogenically fueled rocket engines. In recent years, space-related cryogenic engineering has expanded from booster engines to include spacecraft systems because of the vastly improved performance available from cooled detectors and systems. The requirements for detector cooling in space are examined, taking into account earth observation, atmospheric measurements, infrared astronomy, X-ray astronomy, gamma-ray astronomy, radio astronomy, relativity measurements, magnetic field measurements, time measurements, and data processing. A description is presented of 1978-1981 U.S. spacecraft cryogenic detector systems.

Vorreiter, J. W.↗

Synthesis of a control model for a liquid nitrogen cooled, closed circuit, cryogenic nitrogen wind tunnel and its validation

The details of the efforts to synthesize a control-compatible multivariable model of a liquid nitrogen cooled, gaseous nitrogen operated, closed circuit, cryogenic pressure tunnel are presented. The synthesized model was transformed into a real-time cryogenic tunnel simulator, and this model is validated by comparing the model responses to the actual tunnel responses of the 0.3 m transonic cryogenic tunnel, using the quasi-steady-state and the transient responses of the model and the tunnel. The global nature of the simple, explicit, lumped multivariable model of a closed circuit cryogenic tunnel is demonstrated.

Balakrishna, S.↗

Review of design and operational characteristics of the 0.3-meter transonic cryogenic tunnel

The fundamentals of cryogenic testing are validated both analytically and experimentally employing the 0.3-m transonic cryogenic tunnel. The tunnel with its unique Reynolds number capability has been used for a wide variety of aerodynamic tests. Techniques regarding real-gas effects have been developed and cryogenic tunnel conditions are set and maintained accurately. It is shown that cryogenic cooling, by injecting nitrogen directly into the tunnel circuit, imposes no problems with temperature distribution or dynamic response characteristics.

Ray, E. J.↗

Cryogenic systems for spacecraft

It is noted that the use of cryogenic components on spacecraft, already quite common, will likely increase in the future. Attention is given to a number of applications including earth observation, atmospheric measurements, infrared astronomy and magnetic field measurements. These applications are discussed with regard to their cryogenic requirements. Further, four cryogenic instruments provided by the United States to be launched on spacecraft in the near future are described. Finally, other missions being planned that will use cryogenic instrumentation are also considered.

Vorreiter, J. W.↗

Real-gas effects 1: Simulation of ideal gas flow by cryogenic nitrogen and other selected gases

The thermodynamic properties of nitrogen gas do not thermodynamically approximate an ideal, diatomic gas at cryogenic temperatures. Choice of a suitable equation of state to model its behavior is discussed and the equation of Beattie and Bridgeman is selected as best meeting the needs for cryogenic wind tunnel use. The real gas behavior of nitrogen gas is compared to an ideal, diatomic gas for the following flow processes: isentropic expansion; normal shocks; boundary layers; and shock wave boundary layer interactions. The only differences in predicted pressure ratio between nitrogen and an ideal gas that may limit the minimum operating temperatures of transonic cryogenic wind tunnels seem to occur at total pressures approaching 9atmospheres and total temperatures 10 K below the corresponding saturation temperature, where the differences approach 1 percent for both isentropic expansions and normal shocks. Several alternative cryogenic test gases - air, helium, and hydrogen - are also analyzed. Differences in air from an ideal, diatomic gas are similar in magnitude to those of nitrogen. Differences for helium and hydrogen are over an order of magnitude greater than those for nitrogen or air. Helium and hydrogen do not approximate the compressible flow of an ideal, diatomic gas.

Hall, R. M.↗

Onset of condensation effects in cryogenic wind tunnels

The onset of condensation effects in cryogenic wind tunnels which limits their minimum operating temperatures is examined. If this onset of effects occurs below saturation temperature, then the tunnels may be operated at the lower temperatures and additional benefits to cryogenic tunnel operation resulting in increased Reynolds number capability and reduced operating costs. Both homogeneous and heterogeneous nucleation processes are discussed as they pertain to continuous flow cryogenic wind tunnels. Examples from condensation experiments in the 0.3 m Transonic Cryogenic Tunnel are also reviewed.

Hall, R. M.↗