Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Streamlined Approach for Environmental Restoration Plan for Corrective Action Unit 116: Area 25 Test Cell C Facility, Nevada Test Site, Nevada, Revision 1

This Streamlined Approach for Environmental Restoration (SAFER) Plan identifies the activities required for the closure of Corrective Action Unit (CAU) 116, Area 25 Test Cell C Facility. The Test Cell C (TCC) Facility is located in Area 25 of the Nevada Test Site (NTS) approximately 25 miles northwest of Mercury, Nevada (Figure 1). CAU 116 is currently listed in Appendix III of the Federal Facility Agreement and Consent Order (FFACO) of 1996 (as amended February 2008) and consists of two Corrective Action Sites (CASs): (1) CAS 25-23-20, Nuclear Furnace Piping; and (2) CAS 25-41-05, Test Cell C Facility. CAS 25-41-05 is described in the FFACO as the TCC Facility but actually includes Building 3210 and attached concrete shield wall only. CAU 116 will be closed by demolishing Building 3210, the attached concrete shield wall, and the nuclear furnace piping. In addition, as a best management practice (BMP), Building 3211 (moveable shed) will be demolished due to its close proximity to Building 3210. This will aid in demolition and disposal operations. Radiological surveys will be performed on the demolition debris to determine the proper disposal pathway. As much of the demolition debris as space allows will be placed into the Building 3210 basement structure. After filling to capacity with demolition debris, the basement structure will be mounded or capped and closed with administrative controls. Prior to beginning demolition activities and according to an approved Sampling and Analysis Plan (SAP), representative sampling of surface areas that are known, suspected, or have the potential to contain hazardous constituents such as lead or polychlorinated biphenyls (PCBs) will be performed throughout all buildings and structures. Sections 2.3.2, 4.2.2.2, 4.2.2.3, 4.3, and 6.2.6.1 address the methodologies employed that assure the solid debris placed in the basement structure will not contain contaminants of concern (COCs) above hazardous waste levels. The anticipated post-closure-posting requirements for the mounded/capped basement structure, as well as for the entire CAU, are addressed in Section 4.2.10. The site contains radiologically impacted surfaces and hazardous materials. Based on review of the historical information for CAU 116 and recent site inspections, there is sufficient process knowledge to close CAU 116 using the SAFER process. CAUs that may be closed using the SAFER process have conceptual corrective actions that are clearly identified. Consequently, corrective action alternatives can be chosen prior to completing a corrective action investigation, given anticipated investigation results. The SAFER process combines elements of the data quality objective (DQO) process and the observational approach to plan and conduct closure activities. The DQOs are used to identify the problem and define the type and quality of data needed to complete the investigation phase of the SAFER process. The purpose of the investigation phase is to verify the adequacy of existing information used to determine the chosen corrective action. The observational approach provides a framework for managing uncertainty during the planning and decision-making phases of the project. The SAFER process allows for technical decisions to be made based on information gathered during site visits, interviews, meetings, research, and a consensus of opinion by the decontamination and decommissioning (D&D) team members. Any uncertainties are addressed by documented assumptions that are verified by sampling and analysis, data evaluation, onsite observations, and contingency plans, as necessary. Closure activities may proceed simultaneously with site characterization as sufficient data are gathered to confirm or disprove the assumptions made during selection of the corrective action. If, at any time during the closure process, new information is discovered that indicates that closure activities should be revised, closure activities will be reevaluated as appropriate. Based on a detailed review of historical documentation, there is sufficient process knowledge to close CAU 116 using the SAFER process. The COC have been determined and are discussed in Section 4.1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Weak interaction rate Coulomb corrections in big bang nucleosynthesis

We have applied a fully relativistic Coulomb wave correction to the weak reactions in the full Kawano/Wagoner big bang nucleosynthesis (BBN) code. We have also added the zero-temperature radiative correction. We find that using this higher accuracy Coulomb correction results in good agreement with previous work, giving only a modest {approx}0.04% increase in helium mass fraction over correction prescriptions applied previously in BBN calculations. We have calculated the effect of these corrections on other light element abundance yields in BBN, and we have studied these yields as functions of electron neutrino lepton number. This has allowed insights into the role of the weak neutron-proton interconversion processes in the setting of the neutron-to-proton ratio during the BBN epoch. We find that the lepton capture processes' contributions to this ratio are only second order in the Coulomb correction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Drell-Yan q T resummation of fiducial power corrections at N 3 LL

We consider Drell-Yan production pp → V*X → LX at small q T << Q, where q T and Q are the total transverse momentum and invariant mass of the leptonic final state L. Experimental measurements require fiducial cuts on L, which in general introduce enhanced, linear power corrections in q T /Q. We show that they can be unambiguously predicted from factorization, and resummed to the same order as the leading-power contribution. For the fiducial q T spectrum, they constitute the complete linear power corrections. We thus obtain predictions for the fiducial q T spectrum to N 3 LL and next-to-leading-power in q T /Q. Matching to full NNLO ($α$$^{2}_{s}$), we find that the linear power corrections are indeed the dominant ones, and once included by factorization, the remaining fixed-order corrections become almost negligible below q T ≲ 40 GeV. We also discuss the implications for more complicated observables, and provide predictions for the fiducial Φ* spectrum at N 3 LL+NNLO. We find excellent agreement with ATLAS and CMS measurements of q T and Φ*. We also consider the $p$$^{ℓ}_{T}$ spectrum. We show that it develops leptonic power corrections in q T /(Q – 2$p$$^{ℓ}_{T}$), which diverge near the Jacobian peak $p$$^{ℓ}_{T}$ ~ Q/2 and must be kept to all powers to obtain a meaningful result there. Doing so, we obtain for the first time an analytically resummed result for the $p$$^{ℓ}_{T}$ spectrum around the Jacobian peak at N 3 LL+NNLO. Our method is based on performing a complete tensor decomposition for hadronic and leptonic tensors. We show that in practice this is equivalent to often-used recoil prescriptions, for which our results now provide rigorous, formal justification. Our tensor decomposition yields nine Lorentz-scalar hadronic structure functions, which for Z/γ* → ℓℓ or W → ℓν directly map onto the commonly used angular coefficients, but also holds for arbitrary leptonic final states. In particular, for suitably defined Born-projected leptons it still yields a LO-like angular decomposition even when including QED final-state radiation. Finally, we also discuss the application to q T subtractions. Including the unambiguously predicted fiducial power corrections significantly improves their performance, and in particular makes them applicable near kinematic edges where they otherwise break down due to large leptonic power corrections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of a simultaneous dual-isotope {sup 201}Tl/{sup 123}I-MIBG myocardial SPECT imaging protocol with a CZT camera for trigger zone assessment after myocardial infarction for routine clinical settings: Are delayed acquisition and scatter correction necessary?

Background: Dual-isotope {sup 201}Tl/{sup 123}I-MIBG SPECT can assess trigger zones (dysfunctions in the autonomic nervous system located in areas of viable myocardium) that are substrate for ventricular arrhythmias after STEMI. This study evaluated the necessity of delayed acquisition and scatter correction for dual-isotope {sup 201}Tl/{sup 123}I-MIBG SPECT studies with a CZT camera to identify trigger zones after revascularization in patients with STEMI in routine clinical settings. Methods: Sixty-nine patients were prospectively enrolled after revascularization to undergo {sup 201}Tl/{sup 123}I-MIBG SPECT using a CZT camera (Discovery NM 530c, GE). The first acquisition was a single thallium study (before MIBG administration); the second and the third were early and late dual-isotope studies. We compared the scatter-uncorrected and scatter-corrected (TEW method) thallium studies with the results of magnetic resonance imaging or transthoracic echography (reference standard) to diagnose myocardial necrosis. Results: Summed rest scores (SRS) were significantly higher in the delayed MIBG studies than the early MIBG studies. SRS and necrosis surface were significantly higher in the delayed thallium studies with scatter correction than without scatter correction, leading to less trigger zone diagnosis for the scatter-corrected studies. Compared with the scatter-uncorrected studies, the late thallium scatter-corrected studies provided the best diagnostic values for myocardial necrosis assessment. Conclusions: Delayed acquisitions and scatter-corrected dual-isotope {sup 201}Tl/{sup 123}I-MIBG SPECT acquisitions provide an improved evaluation of trigger zones in routine clinical settings after revascularization for STEMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone Beam Computed Tomography Number Errors and Consequences for Radiotherapy Planning: An Investigation of Correction Methods

Purpose: The potential of keV cone beam computed tomography (CBCT) for guiding adaptive replanning is well-known. There are impediments to this, one being CBCT number accuracy. The purpose of this study was to investigate CBCT number correction methods and the affect of residual inaccuracies on dose deposition. Four different correction strategies were applied to the same patient data to compare performance and the sophistication of correction-method needed for acceptable dose errors. Methods and Materials: Planning CT and CBCT reconstructions were used for 12 patients (6 brain, 3 prostate, and 3 bladder cancer patients). All patients were treated using Elekta linear accelerators and XVI imaging systems. Two of the CBCT number correction methods investigated were based on an algorithm previously proposed by the authors but only previously applied to phantoms. Two further methods, based on an approach previously suggested in the research literature, were also examined. Dose calculations were performed using scans of a 'worst' subset of patients using the Pinnacle{sup 3} version 9.0 treatment planning system and the patients' clinical plans. Results: All mean errors in CBCT number were <50 HU, and all correction methods performed well or adequately in dose calculations. The worst single dose discrepancy identified for any of the examined methods or patients was 3.0%. Mean errors in the doses to treatment volumes or organs at risk were negatively correlated with the mean error in CT number. That is, a mean CT number that was too large, averaged over the entire CBCT volume, implied an underdosing in a volume-of-interest and vice versa. Conclusions: Results suggest that (1) the correction of CBCT numbers to within a mean error of 50 HU in the scan volume provides acceptable discrepancies in dose (<3%) and (2) this is achievable with even quite unsophisticated correction methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Corrected Implicit Monte Carlo

Here in this work we develop a set of nonlinear correction equations to enforce a consistent time-implicit emission temperature for the original semi-implicit IMC equations. We present two possible forms of correction equations: one results in a set of non-linear, zero-dimensional, non-negative, explicit correction equations, and the other results in a non-linear, non-negative, Boltzman transport correction equation. The zero-dimensional correction equations adheres to the maximum principle for the material temperature, regardless of frequency-dependence, but does not prevent maximum principle violation in the photon intensity, eventually leading to material overheating. The Boltzman transport correction guarantees adherence to the maximum principle for frequency-independent simulations, at the cost of evaluating a reduced source non-linear Boltzman equation. Finally, we present numerical evidence suggesting that the Boltzman transport correction, in its current form, significantly improves time step limitations but does not guarantee adherence to the maximum principle for frequency-dependent simulations.

97 MATHEMATICS AND COMPUTING↗

Viscous corrections to electromagnetic emissivities in QCD

We provide a general framework for the derivation of the hydrodynamical corrections to the QCD electromagnetic emissivities in a viscous fluid. Here, assuming that the emission times are short in comparison to the fluid evolution time, we show that the leading corrections in the fluid gradients are controlled by the bulk and shear tensors times pertinent response functions involving the energy-momentum tensor. In a hadronic fluid phase, we detail these contributions using spectral functions. Using the vector dominance approximation, we show that the bulk viscosity correction to the photon rate is sizable, while the shear viscosity is negligible for about all frequencies. In the partonic phase near the transition temperature, we provide an assessment of the viscous corrections to the photon and dilepton emissions, using a nonperturbative quark-gluon plasma with soft thermal gluonic corrections in the form of operators of leading mass dimension. Again, the thermal bulk viscosity corrections are found to be larger than the thermal shear viscosity corrections at all energies for both the photon and dilepton in the partonic phase.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Efficient scatter distribution estimation and correction in CBCT using concurrent Monte Carlo fitting

Purpose: X-ray scatter is a significant impediment to image quality improvements in cone-beam CT (CBCT). The authors present and demonstrate a novel scatter correction algorithm using a scatter estimation method that simultaneously combines multiple Monte Carlo (MC) CBCT simulations through the use of a concurrently evaluated fitting function, referred to as concurrent MC fitting (CMCF). Methods: The CMCF method uses concurrently run MC CBCT scatter projection simulations that are a subset of the projection angles used in the projection set, P, to be corrected. The scattered photons reaching the detector in each MC simulation are simultaneously aggregated by an algorithm which computes the scatter detector response, S{sub MC}. S{sub MC} is fit to a function, S{sub F}, and if the fit of S{sub F} is within a specified goodness of fit (GOF), the simulations are terminated. The fit, S{sub F}, is then used to interpolate the scatter distribution over all pixel locations for every projection angle in the set P. The CMCF algorithm was tested using a frequency limited sum of sines and cosines as the fitting function on both simulated and measured data. The simulated data consisted of an anthropomorphic head and a pelvis phantom created from CT data, simulated with and without the use of a compensator. The measured data were a pelvis scan of a phantom and patient taken on an Elekta Synergy platform. The simulated data were used to evaluate various GOF metrics as well as determine a suitable fitness value. The simulated data were also used to quantitatively evaluate the image quality improvements provided by the CMCF method. A qualitative analysis was performed on the measured data by comparing the CMCF scatter corrected reconstruction to the original uncorrected and corrected by a constant scatter correction reconstruction, as well as a reconstruction created using a set of projections taken with a small cone angle. Results: Pearson’s correlation, r, proved to be a suitable GOF metric with strong correlation with the actual error of the scatter fit, S{sub F}. Fitting the scatter distribution to a limited sum of sine and cosine functions using a low-pass filtered fast Fourier transform provided a computationally efficient and accurate fit. The CMCF algorithm reduces the number of photon histories required by over four orders of magnitude. The simulated experiments showed that using a compensator reduced the computational time by a factor between 1.5 and 1.75. The scatter estimates for the simulated and measured data were computed between 35–93 s and 114–122 s, respectively, using 16 Intel Xeon cores (3.0 GHz). The CMCF scatter correction improved the contrast-to-noise ratio by 10%–50% and reduced the reconstruction error to under 3% for the simulated phantoms. Conclusions: The novel CMCF algorithm significantly reduces the computation time required to estimate the scatter distribution by reducing the statistical noise in the MC scatter estimate and limiting the number of projection angles that must be simulated. Using the scatter estimate provided by the CMCF algorithm to correct both simulated and real projection data showed improved reconstruction image quality.

60 APPLIED LIFE SCIENCES↗

Complete lowest order radiative corrections in semi-inclusive scattering of polarized particles

For this work, the lowest order radiative corrections to the cross section and asymmetries measured in experiments on semi-inclusive deep inelastic scattering of polarized particles were calculated. Both exact and leading log expressions were presented and discussed for the total correction that include the contributions from the processes of i) real photon emission with semi-inclusive processes, ii) loop diagrams, and iii) real photon emission with exclusive processes. Radiative corrections to the Sivers and Collins asymmetries in $\pi^+$ electroproduction were studied numerically within the kinematical conditions of modern experimental environments at Jefferson Laboratory (JLab). The Wandzura-Wilczek approximation for the semi-inclusive structure functions and MAID2007 parameterization for the six amplitudes of exclusive processes were used in numeric analyses. The results show that i) radiative effects can generate a correction comparable to the size of Sivers and Collins asymmetries at the Born level, ii) there is good agreement between the exact and leading-order corrections, iii) external functions (that is, other than the Sivers and Collins functions in the respective asymmetries) can generate a contribution to the radiative correction up to 20%, and iv) there exists a strong dependence of the radiative correction on the models for semi-inclusive and exclusive structure functions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Afterpulse correction for micro-pulse lidar to improve middle and upper tropospheric aerosol measurements

Micro-pulse lidar (MPL) measurements have been widely used in atmospheric research over the past few decades. However, the MPL afterpulse noise has a large impact on the MPL aerosol measurement in the middle and upper troposphere, and an effective correction method is still lacking. Here, a new afterpulse correction approach is presented by using measurements with low-level optically thick clouds to act as the lids blocking atmospheric signals beyond the clouds completely. Examples are provided to illustrate the effectiveness of this correction method. Using one-year 2014 MPL measurements at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) site, the impact of the correction on the aerosol measurements is quantified. The relative error (RE, %) of attenuated backscattering ratio (ABR) without the afterpulse correction is 30% and 190% at the height of 1.00 km and 9.00 km (AGL), and the RE is larger for weaker aerosol signals (ABR<2). The RE of linear depolarization ratio (LDR), which is significantly higher than that of ABR for a given aerosol layer, is highly non-linear above 3.00 km, with a value of 300%-900% for weak aerosols (ABR<2) above 3.00 km. Therefore, the afterpulse correction is critical for the middle and upper tropospheric aerosol observations. We demonstrated that our afterpulse correction can provide reasonable particle depolarization ratio (PDR) to properly identify dust aerosols. The newly developed method can be applied to long-term MPL measurements to support aerosol and mixed-phase/ice cloud interaction study at the NSA site.

54 ENVIRONMENTAL SCIENCES↗

Final corrective action study for the former CCC/USDA facility in Ramona, Kansas.

Past operations at a grain storage facility formerly leased and operated by the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) in Ramona, Kansas, resulted in low concentrations of carbon tetrachloride in groundwater that slightly exceed the regulatory standard in only one location. As requested by the Kansas Department of Health and Environment, the CCC/USDA has prepared a Corrective Action Study (CAS) for the facility. The CAS examines corrective actions to address groundwater impacted by the former CCC/USDA facility but not releases caused by other potential groundwater contamination sources in Ramona. Four remedial alternatives were considered in the CAS. The recommended remedial alternative in the CAS consists of Environmental Use Control to prevent the inadvertent use of groundwater as a water supply source, coupled with groundwater monitoring to verify the continued natural improvement in groundwater quality. The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) has directed Argonne National Laboratory to prepare a Corrective Action Study (CAS), consistent with guidance from the Kansas Department of Health and Environment (KDHE 2001a), for the CCC/USDA grain storage facility formerly located in Ramona, Kansas. This effort is pursuant to a KDHE (2007a) request. Although carbon tetrachloride levels at the Ramona site are low, they remain above the Kansas Tier 2 risk-based screening level (RBSL) and the U.S. Environmental Protection Agency (EPA) maximum contaminant level (MCL) of 5 {micro}g/L (Kansas 2003, 2004). In its request for the CAS, the KDHE (2007a) stated that, because of these levels, risk is associated with potential future exposure to contaminated groundwater. The KDHE therefore determined that additional measures are warranted to limit future use of the property and/or exposure to contaminated media as part of site closure. The KDHE further requested comparison of at least two corrective action alternatives to the 'no-action' alternative, as the basis for the Draft Corrective Action Decision for the site. The history and nature of the contamination and previous investigations are summarized in Section 2. Also included in Section 2 is an evaluation of human and environmental targets and potential exposure pathways. Section 3 describes the corrective action goals and applicable or relevant and appropriate requirements (ARARs). Section 4 describes four alternatives, Section 5 analyzes the alternatives in detail, and Section 6 compares the alternatives. Section 6 also includes a summary and a recommended corrective action.

54 ENVIRONMENTAL SCIENCES↗

Response to External Peer Review Team Report for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada National Security Site, Nye County, Nevada, Revision 1

The Underground Test Area (UGTA) Corrective Action Unit (CAU) 97, Yucca Flat/Climax Mine (YF/CM), in the northeast part of the Nevada National Security Site (NNSS) requires environmental corrective action activities to assess contamination resulting from underground nuclear testing. These activities are necessary to comply with the UGTA corrective action strategy defined in Appendix VI, Revision No. 4, of the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended). The Phase I Flow and Transport Model Document for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada National Security Site, Nye County, Nevada (N-I, 2013a) was developed and subjected to an external peer review as required by the corrective action investigation (CAI) stage of the UGTA strategy. The YF/CM Peer Review Committee (PRC) raised a number of questions and provided recommendations for supplemental analyses (in the External Peer Review Team Report for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada National Security Site, Nye County, Nevada [N-I, 2015]). The purpose of this document is to provide responses to the PRC recommendations addressing the uncertainties identified by the PRC so that sufficient confidence in the contaminant boundary forecasts is established to advance to the Corrective Action Decision Document (CADD)/Corrective Action Plan (CAP) stage and initiate model evaluations. The PRC summarized their concerns and recommendations, and presented discussions of each of these uncertainties in their report (N-I, 2015). The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) responses are summarized in Table ES-1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HEAVY ION FUSION SCIENCE VIRTUAL NATIONAL LABORATORY 1ST QUARTER 2010 MILESTONE REPORT: Simulations of fast correction of chromatic aberrations to establish physics specifications for implementation on NDCX-1 and NDCX-2

This milestone has been accomplished. The Heavy Ion Fusion Science Virtual National Laboratory has completed simulations of a fast correction scheme to compensate for chromatic and time-dependent defocusing effects in the transport of ion beams to the target plane in the NDCX-1 facility. Physics specifications for implementation in NDCX-1 and NDCX-2 have been established. This milestone has been accomplished. The Heavy Ion Fusion Science Virtual National Laboratory has completed simulations of a fast correction scheme to compensate for chromatic and time-dependent defocusing effects in the transport of ion beams to the target plane in the NDCX-1 facility. Physics specifications for implementation in NDCX-1 and NDCX-2 have been established. Focal spot differences at the target plane between the compressed and uncompressed regions of the beam pulse have been modeled and measured on NDCX-1. Time-dependent focusing and energy sweep from the induction bunching module are seen to increase the compressed pulse spot size at the target plane by factors of two or more, with corresponding scaled reduction in the peak intensity and fluence on target. A time-varying beam envelope correction lens has been suggested to remove the time-varying aberration. An Einzel (axisymmetric electric) lens system has been analyzed and optimized for general transport lines, and as a candidate correction element for NDCX-1. Attainable high-voltage holdoff and temporal variations of the lens driving waveform are seen to effect significant changes on the beam envelope angle over the duration of interest, thus confirming the utility of such an element on NDCX-1. Modeling of the beam dynamics in NDCX-1 was performed using a time-dependent (slice) envelope code and with the 3-D, self-consistent, particle-in-cell code WARP. Proof of concept was established with the slice envelope model such that the spread in beam waist positions relative to the target plane can be minimized with a carefully designed Einzel lens waveform and transport line. WARP simulations have verified the efficacy of the Einzel lens while including more detailed beam physics. WARP simulations have also indicated some unpredicted transittime effects, and methods are currently being explored to compensate and reduce this complication. We have explored the use of an Einzel lens, or system of Einzel lenses, to compensate for chromatic aberrations in the beam focal spot in the NDCX-2 target plane. The final beam manipulations in NDCX-2 (linear velocity ramp, charge neutralization, high field final focus solenoid) are similar to NDCX-1 though the NDCX-2 beam has much higher energy and current. The most relevant distinctions are that the pulse duration at the entrance to the drift compression section is tenfold shorter, and that the beam energy tenfold higher, than in NDCX-1. Placing a time-dependent, envelope angle correcting element at the neutralized drift region entrance presents a very significant challenge to voltage holdoff and voltage swing V(t) in a single Einzel lens. Placing the Einzel lens(es) further upstream reduces the required voltage risetime V'(t) to effect the necessary envelope correction, while increasing the duration over which the timedependent voltage must vary. While this simplifies the technological challenge of designing and operating a Einzel lens in NDCX-2, it does require much finer control of the correcting waveform and measurements of its effect on space-charge dominated beams over a much longer axial path length to target than in the NDCX-1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parallax-corrected VISST-derived pixel-level products from satellite GOES-16

The NASA Langley group led by William Smith produced GOES-16 satellite cloud retrievals over an approximate 10 by 10 degree region over the CACTI field campaign location. These retrievals are described here: https://www.arm.gov/capabilities/vaps/visst and are available for download here . They use algorithms historically called VISST that are now referred to as SatCORPS. More information can be found in Trepte et al. (2019), Minnis et al. (2021), and Yost et al. (2021). If using this dataset, please cite these references, the CACTI VISST dataset DOI found at the download link above, and this dataset’s DOI. The CACTI VISST pixel-level retrievals are on a 2 km spatial grid and available every 15 minutes (every 10 minutes late in the campaign), producing 21,765 files for the entire field campaign between October 2018 and April 2019. They are not corrected for parallax error, which is an offset in the actual geographical location of a cloud above the surface due to the satellite viewing the cloud partly from the side off nadir. This dataset applies a correction for parallax using the location relative to the satellite and the retrieved cloud top height above the surface, which allows the dataset to be geo-located with surface-based observations. The parallax correction for each location depends on the longitude, latitude and cloud top height above ground level (AGL) for that longitude and latitude in the original VISST files. The cloud top height AGL requires first computing the surface elevation at each VISST grid point. Data from the Advanced Spaceborne Thermal Emission and Reflection (ASTER) Global Digital Elevation Map Version 3 at 30-m resolution is projected onto the VISST grid using conservative coarsening (conserving surface elevation) in the xESMF Python package. The surface elevation is then subtracted from the VISST-retrieved cloud top height above mean sea level. These cloud top heights AGL are then combined with longitude and latitude to estimate the latitude and longitude corrections. Due to variability in cloud top height, the parallax shifts produce an irregular grid of values since higher cloud tops are shifted further than lower cloud tops. A ball tree-based neighbor search with Haversine distance is performed using the Python-based scikit-learn library to find the nearest VISST grid point to each parallax correction-shifted point. The data value of the shifted point is then assigned to that VISST grid point. In this manner, the irregular geographical shifts to correct for parallax are projected back to the rectilinear VISST grid. Because relatively higher clouds should obscure lower clouds, the variable values for the highest cloud top are preferentially chosen if two or more values are assigned to a grid point. The parallax correction should be viewed as an improved but still imperfect estimation of the cloud top locations, largely because the cloud top height is an imperfect retrieval. Please see the attached README document for further information. Users are encouraged to contact the authors with any additional questions.

54 ENVIRONMENTAL SCIENCES↗

Nonperturbative QCD corrections to electroweak observables

Nonperturbative QCD corrections are important to many low-energy electroweak observables, for example the muon magnetic moment. However, hadronic corrections also play a significant role at much higher energies due to their impact on the running of standard model parameters, such as the electromagnetic coupling. Currently, these hadronic contributions are accounted for by a combination of experimental measurements and phenomenological modeling but ideally should be calculated from first principles. Recent developments indicate that many of the most important hadronic corrections may be feasibly calculated using lattice QCD methods. To illustrate this, we will examine the lattice computation of the leading-order QCD corrections to the muon magnetic moment, paying particular attention to a recently developed method but also reviewing the results from other calculations. We will then continue with several examples that demonstrate the potential impact of the new approach: the leading-order corrections to the electron and tau magnetic moments, the running of the electromagnetic coupling, and a class of the next-to-leading-order corrections for the muon magnetic moment. Along the way, we will mention applications to the Adler function, the determination of the strong coupling constant and QCD corrections to muonic-hydrogen.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-point parallel disk correction for asymptotically nonlinear oscillatory shear

We derive exact single-point corrections for parallel disk measurements of all four asymptotically nonlinear measures under strain-controlled oscillatory shear. In this regime, sometimes called medium-amplitude oscillatory shear (MAOS), the derivatives appearing in the general stress correction are constant over the range of interest. This enables an exact single-point correction of all four shear stress components and material functions in the asymptotically nonlinear regime. This greatly simplifies the data processing and allows convenient measurements of true nonlinear material functions with parallel disk geometries. We use a strain amplitude expansion for the stress response, introducing a general non-integer strain amplitude scaling for the leading order nonlinearity, σ ~ γ α , where typically α = 3 has been assumed in the past. The stress corrections are a multiplicative amplification by a factor f(α) = α+3/4, shown for the first time for all four asymptotically nonlinear coefficients. Experimental measurements are presented for the four asymptotically nonlinear signals on an entangled polymer melt of cis-1,4-polyisoprene, using both parallel disk and cone fixtures. The polymer melt follows a cubic (α = 3) strain amplitude scaling in the MAOS regime. Furthermore, the theoretical corrections indicate a 50 % amplification of the apparent signals measured with the parallel disk fixture. The corrected (amplified) signals match the measurements with the cone.

42 ENGINEERING↗

From fault-detection to automated fault correction: A field study

A fault detection and diagnostics (FDD) tool, as addressed by this study, is a tool that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Although FDD tools can inform operators of building operational faults, currently an action is always required to correct the faults to generate energy savings. Fault auto-correction integrating with commercial FDD technology offerings can close the loop between the passive diagnostics and active control, increase the savings generated by FDD tools, and reduce the reliance on human intervention. This paper presents the field study of seven fault auto-correction algorithms implemented in commercial FDD platforms. Implementation includes software changes in the FDD tools and additional controls hardware or software changes in the BAS that were required to enable the execution of different types of auto-correction algorithms in real buildings. The routines successfully and automatically correct faults and improve the operation of large built-up Heating, Ventilation, and Air Conditioning (HVAC) systems, common in most commercial buildings. The auto-correction algorithms are tested across four buildings and three different building automation systems, following a rigorous procedure to make sure they work properly and do not negatively impact the system and building occupants. Finally, technology benefits, market drivers, and scalability changes are drawn from the implementation effort and test results, to drive future research and industry engagement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Correction of Specimen Strain Measurement in Kolsky Tension Bar Experiments on Work-Hardening Materials

Cylindrical dog-bone (or dumbbell) shaped samples have become a common design for dynamic tensile tests of ductile materials with a Kolsky tension bar. When a direct measurement of displacement between the bar ends is used to reveal the specimen strain, the actual strain in the specimen gage section is overestimated due to strain in the specimen shoulder and needs to be corrected. The currently available correction method works well for elastic-perfectly plastic materials but may not be applicable to materials that exhibit significant work-hardening behavior. Here, we developed a new specimen strain correction method for materials possessing an elastic-plastic with linear work-hardening stress-strain response. A Kolsky tension bar test of a Fe-49Co-2V alloy (known by trade names Hiperco and Permendur) was used to demonstrate the new specimen strain correction method. This new correction method was also used to correct specimen strains in Kolsky tension bar experiments on two other materials: 4140 alloy, and 304L-VAR stainless steel, which had different work-hardening behavior.

36 MATERIALS SCIENCE↗