Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of different operating strategies of thermal energy storage with radiant cooling system

Thermal energy storage systems in building cooling applications have been explored extensively as a peak load-shifting technology. Thermal energy storage performance has been recognized and studied from an energy cost-savings point of view because of peak-valley price differences, but not many studies have been conducted from an energy savings viewpoint. This study experimentally investigates the performance of the energy storage-retrofitted to a ceiling-type radiant cooling system. To study the performance, a water-based storage system was designed and developed for an academic office building equipped with a radiant cooling system. The water in the storage tank was cooled to a certain storage temperature in the nighttime, and the same water was used during the daytime for meeting the cooling load. Different combinations of charging and discharging schedules were analyzed. The key objective of the study was to achieve energy savings and energy-cost savings simultaneously. This objective was accomplished by identifying the major factors contributing to the energy consumption of the storage-retrofitted cooling system and devising novel operating strategies, leading to an enhanced energy savings potential. Two operating strategies comprising 24 operating scenarios were compared and the storage was used to dispatch the load for 3 hours of the day as a full storage unit. Results showed that in hot and dry climate conditions, using the storage with the radiant cooling system offered energy savings of 3% to 14%. The energy-cost analysis was also performed using a time-of-day electricity tariff plan. The energy-cost savings varied from 17.5% to 22.4% for these operating scenarios.

25 ENERGY STORAGE↗

The influence of cooling rates on strain phase diagrams and domain structures of ferroelectric thin films: A case study of PbTiO 3

Strain engineering has been established as an effective approach to control phase equilibria, domain configurations, and functional properties of ferroelectric thin films. Temperature-strain phase diagrams have been used as powerful tools for providing insights into strain engineering. However, almost all existing phase diagrams established using the phase-field approach assume quenching conditions without considering actual cooling rates during the post-deposition annealing process of ferroelectric thin films. Within this work, we systematically investigate the influence of cooling rates on domain structures and the strain-phase diagram of ferroelectric thin films using phase-field simulations, taking PbTiO 3 thin films as a model system. We found that both the position of phase boundaries in the strain phase diagrams and the domain morphology are significantly influenced by the cooling rates. It is revealed that while the paraelectric-ferroelectric phase boundary remains invariant, the phase boundaries between single-phase and multi-phase regions tend to shift toward the corresponding multi-phase region as the cool rate reduces. Slow cooling generally leads to more ordered domain structures with increased domain size. Using the obtained equilibrium domain structures, we calculated effective thermal conductivities and found significant variations that can be tuned by the cooling rates. In conclusion, this work reveals an underexplored yet critical impact of cooling rates on phase equilibria and domain structures in ferroelectric thin films, which may inspire further fine-tuning of domains and domain walls in low-dimensional ferroelectrics for multifunctional applications.

Domain structures↗

Assessing parallel path cooling tower performance via artificial neural networks

Real-time monitoring of a research nuclear reactor, a system in which all generated power is dissipated to the environment, can be performed via analysis of the heat rejection from the cooling system. Given an inlet water temperature and flow rate, the reactor power can be well-approximated from the outlet water temperature; however, the instrumentation to measure outlet conditions may not be robust or accurate. If we know how a cooling tower performs from historical data, but cannot measure the outlet temperature, a mathematical representation of the system can be inverted to obtain the outlet water temperature that describes the cooling capacity. Unfortunately, model inversion processes are computationally expensive. To address this, an artificial neural network (ANN) is implemented to assess the performance of a multi-cell cooling tower for a nuclear reactor. This approach leverages the Merkel model to obtain an extensive data set describing performance of the cooling tower cells throughout a wide array of potential operating conditions. The Merkel model is expressed as a function of four parameters: the inlet and outlet water temperatures, inlet air wet bulb temperature, and ratio of liquid-to-gas mass flow rates (L/G), which together provide a non-dimensional number indicative of cooling tower performance, called the Merkel integral. Computing a 4-dimensional data structure that describes finite combinations of the Merkel integral, an inverse model is then generated using an ANN to determine the cell outlet water temperature from the other three model parameters along with the computed Merkel integral. Compared to traditional model inversion methods, the ANN reduces the computational time by approximately 4 orders of magnitude, with effectively no sacrifice to solution accuracy, and could be applied for different cooling towers in the event the performance curve is known. Finally, three use cases of the ANN are then reviewed: (1) determining the cell outlet water temperatures when gas flow at rated conditions (GFRC) is known, (2) performing the prior case without knowledge of the GRFC, and (3) assessing performance differences between the individual tower cells.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of cooling setpoint setback savings in commercial buildings using electricity and exterior temperature time series data

Commercial buildings account for a significant amount of total energy produced in the US, and the Heating Ventilation and Cooling (HVAC) systems are one of the most significant components of their overall consumption. In this study, we proposed a new data-driven approach to evaluate HVAC cooling systems in commercial buildings and identify savings opportunities. The focus is an investigation of the impact of thermostat setpoint setback but using only whole building, electricity data taken at 15-min intervals for the analysis. We conducted a comparative study of setpoint setback characteristics on 432 commercial buildings with 5 building usage types across the United States. To accomplish this, both piecewise and Random Forest regression algorithms were employed using electricity and exterior temperature datasets to identify operational characteristics and the effective setpoints in the building to determine the corresponding savings opportunities. Both occupied and unoccupied time periods were studied across cooling degree days (CDD), when air conditioning is typically operational. Here the results show that in commercial buildings, on average, cooling systems account for 9.5% of total consumption. When a one degree setback during the cooling season is applied, an average of approximately 1.1% of annual consumption is achieved; retail and office buildings demonstrate the highest potential for savings. Additionally, we identified that the number of cooling degree days and base to peak ratio (BPR) are the most important variables for predicting the magnitude of the consumption of cooling systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulations of the fault current limiting operation of a long-length REBCO CORC ® superconducting cable cooled by helium gas

Conductor-on-round-core (CORC®) cables composed of rare-earth-barium-copper-oxide high-temperature superconducting (HTS) tapes are of great interest for power transmission applications due to their many advantages such as high power density, light weight, and low loss. Closed circulation loops of cryogenic helium gas can be used to cool HTS cables down to low temperatures to significantly improve their current-carrying capacity. Coupled circuit-electromagnetic-thermal finite element simulations implemented in the COMSOL Multiphysics package were developed, validated, and then used for simulating the fault current limiting (FCL) performance and the cooling processes of an 8-layer CORC® cable cooled with a flow of cryogenic helium gas. In the simulations, the temperature dependence of the electrical and thermal properties of all component materials is implemented for improved accuracy. To overcome computational challenges caused by the considerable difference in geometrical scales (i.e. few-µm-thick HTS layers versus 10 m-long HTS cable), the model is divided into two separate simulations. The first simulation is performed on the transverse cross-section of the cable to calculate the electric field, heating power and temperature rise in each component of a CORC® cable during FCL operation. The heating power calculated in the first simulation is transferred to the second model to simulate the cooling of a 10 m-long cable after the fault is cleared. The effect of the helium gas flow rate on the cooling process is also investigated to develop strategic approaches for optimizing cooling systems for HTS cables with FCL capability. The simulations indicated that a 40 ms fault with a voltage drop of 20 V m −1 along the cable can result in a temperature increase from 60 K to about 165 K inside the cable, and it takes about 500 s to cool the cable back to nearly 60 K with a flow of cold helium gas at a rate of 5 g s −1 .

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strong influence of convective heat transfer efficiency on the cooling benefits of green roof irrigation

Abstract By enhancing evapotranspiration (ET), green roofs provide cooling benefits for the urban environment and are recognized as a promising heat mitigation strategy. The evaporative cooling effects of green roofs strongly depend on the soil moisture conditions and thus irrigation may be needed to sustain the cooling benefits. It has been shown that the magnitude of cooling benefits offered by green roof irrigation varies spatially, but its controlling factors remain elusive. In this study, we combine a surface energy balance (SEB) model with global simulations generated by an improved Earth System Model to illustrate the key factors controlling the cooling benefits of green roof irrigation. We employ a simple irrigation scheme, which is only active when there is no ice in soil layers and when the soil moisture is below field capacity. As a result, most of the irrigation water leaves the green roof system via ET. We find that the magnitude and also the spatial variability of the cooling benefits of green roof irrigation are controlled by the irrigation amount, and a surface energy redistribution factor that encodes the efficiencies of different SEB components in transferring heat. Further analysis indicates that the enhancement of latent heat flux due to irrigation is largely balanced by the reduction of sensible heat flux on green roofs. Therefore, the amount of irrigation needed per unit decrease of green roof surface temperature is mainly controlled by the convective heat transfer efficiency. A lower convective heat transfer efficiency (e.g. under a lower wind speed) helps reduce the amount of irrigation needed per unit decrease of green roof surface temperature. This study highlights the importance of SEB in constraining the cooling benefits of green roof irrigation and provides valuable guidance for urban planners and policy makers in terms of heat mitigation and sustainable water management.

Wang, Linying (ORCID:0000000308769220)↗

β Decay of 61 V and its Role in Cooling Accreted Neutron Star Crusts

The interpretation of observations of cooling neutron star crusts in quasipersistent x-ray transients is affected by predictions of the strength of neutrino cooling via crust Urca processes. The strength of crust Urca neutrino cooling depends sensitively on the electron-capture and β -decay ground-state-to-ground-state transition strengths of neutron-rich rare isotopes. Nuclei with a mass number of A = 61 are predicted to be among the most abundant in accreted crusts, and the last remaining experimentally undetermined ground-state-to-ground-state transition strength was the β decay of 61 V. This Letter reports the first experimental determination of this transition strength, a ground-state branching of $8.1^{+4.0}_{- 3.1}%$, corresponding to a log ft value of $5.5^{+0.2}_{-0.2}$. This result was achieved through the measurement of the β -delayed γ rays using the total absorption spectrometer SuN and the measurement of the β -delayed neutron branch using the neutron long counter system NERO at the National Superconducting Cyclotron Laboratory at Michigan State University. This method helps to mitigate the impact of the pandemonium effect in extremely neutron-rich nuclei on experimental results. The result implies that A = 61 nuclei do not provide the strongest cooling in accreted neutron star crusts as expected by some predictions, but that their cooling is still larger compared to most other mass numbers. Finally, only nuclei with mass numbers 31, 33, and 55 are predicted to be cooling more strongly. However, the theoretical predictions for the transition strengths of these nuclei are not consistently accurate enough to draw conclusions on crust cooling. With the experimental approach developed in this work, all relevant transitions are within reach to be studied in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Single and Double-Sided Jet Impingement Cooling for SiC-Based Power Modules

Efficient thermal management of power electronics systems is crucial for higher reliability. With the miniaturization of systems, high-loss-density electronics require cooling systems that can extract a large amount of heat. This study explored a liquid-jet-impingement-based direct substrate cooling system for single-sided and double-sided cooling to improve heat extraction efficiency and improve the power density by reducing the volume and mass. The cooling system was implemented for a SiC-based direct bonded copper substrate. Numerical simulations were performed to determine the effects of nozzle diameter, the number of nozzles, and nozzle array orientation on single-sided cooling and thermal performance gain over double-sided cooling. A novel manifold design was proposed that reduced the volume and mass of the manifold and still achieved the target power density. The performance of the proposed design was compared with the pin-fin-based cooling system used in the BMW I3 module, and a comparative analysis was done.

Barua, Himel↗

A Study of Temperature Distribution and Thermal Stresses in a Hot Rock Due to Rapid Cooling

Thermal stresses may be induced in a hot dry rock when a cold fluid is injected in the well. To study this problem, we look at the thermoelastic response of a hot rock that is suddenly cooled. The cooling is assumed to be either at a constant temperature or at a constant heat flux per unit depth. Our approach is to nondimensionalize the equations and perform a parametric study and look at the temperature distribution and the induced-thermal stresses. The results indicate that depending on the extent of cooling and the cooling time, thermal stresses can be induced. Numerical simulations on sandstone, with an initial uniform temperature of 473 K, are also carried out. The results show that if the cooling is due to the surface temperature maintained at 463 K (10 °C lower than the initial temperature of the hot rock), thermal stresses that are larger than the rock tensile strength could be induced. When the cooling is due to a constant surface heat flux, this temperature can be reached after about 777 days of cooling with a minimum value of a heat flux of -20 W/m.

Tran, Phuoc↗

Performance of Public Film Cooling Geometries Produced Through Additive Manufacturing

Abstract Film cooling is an essential cooling technology to allow modern gas turbines to operate at high temperatures. For years, researchers in this community have worked to improve the effectiveness of film cooling configurations by maximizing the coolant coverage and minimizing the heat flux from the hot gas into the part. Working toward this goal has generated many promising film cooling concepts with unique shapes and configurations. However, until recently, many of these designs were challenging to manufacture in actual turbine hardware due to limitations with legacy manufacturing methods. Now, with the advances in additive manufacturing, it is possible to create turbine parts using high-temperature nickel alloys that feature detailed and unique geometry features. Armed with this new manufacturing power, this study aims to build and test the promising designs from the public literature that were previously difficult or impossible to implement. In this study, different cooling hole designs were manufactured in test coupons using a laser powder bed fusion process. Each nickel alloy coupon featured a single row of engine scale cooling holes, fed by a microchannel. To evaluate performance, the overall cooling effectiveness of each coupon was measured using a matched Biot test at engine relevant conditions. The results showed that certain hole shapes are better suited for additive manufacturing than others and that the manufacturing process can cause significant deviations from the performance reported in the literature.

Engineering↗

High-performance multimode elastocaloric cooling system

Developing zero–global warming potential refrigerants has emerged as one area that helps address global climate change concerns. Various high-efficiency caloric cooling techniques meet this goal, but scaling them up to technologically meaningful performance remains challenging. We have developed an elastocaloric cooling system with a maximum cooling power of 260 watts and a maximum temperature span of 22.5 kelvin. These values are among the highest reported for any caloric cooling system. Its key feature is the compression of fatigue-resistant elastocaloric nitinol (NiTi) tubes configured in a versatile multimode heat exchange architecture, which allows the harnessing of both high delivered cooling power and large temperature spans. Our system shows that elastocaloric cooling, which only emerged 8 years ago, is a promising direction for commercializing caloric cooling.

Science & Technology - Other Topics↗

Historical Subsurface Cooling in the Tropical Pacific and Its Dynamics

Abstract Understanding how the tropical Pacific responds to rising greenhouse gases in recent decades is of paramount importance given its central role in global climate systems. Extensive research has explored the long-term trends of tropical Pacific sea surface temperatures (SSTs) and the overlying atmosphere, yet the historical change in the upper ocean has received far less attention. Here, we present compelling evidence of a prominent subsurface cooling pattern along the thermocline in the central-to-eastern tropical Pacific since 1958. This subsurface cooling has been argued to be contributing to the observed cooling or lack of warming of the equatorial cold tongue SST. We further demonstrate that different mechanisms are responsible for different parts of the subsurface cooling. In the central-to-eastern equatorial Pacific and the southeastern off-equatorial Pacific, where zonal wind stress strengthens, a pronounced subsurface cooling trend emerges just above the thermocline that is closely tied to increased Ekman pumping. In the eastern equatorial Pacific where zonal wind stress weakens, the westward surface current and eastward Equatorial Undercurrent weaken as well, resulting in reduced vertical current shear and increased ocean stability, which suppresses vertical mixing and leads to local cooling. We conclude that the historical subsurface cooling is primarily linked to dynamical adjustments of ocean currents to tropical surface wind stress changes.

Jiang, Feng↗

ELECTRON COOLING USING A PULSED AND DITHERING BEAM FROM AN ELECTROSTATIC ELECTRON COOLER

Electron cooling continues to be an invaluable technique to reduce and maintain the emittance in hadron storage rings such as the EIC and EICC where stochastic cooling is inefficient and radiative cooling is negligible. Extending the energy range of electron coolers beyond what is feasible with the conventional, electrostatic approach necessitates the use of RF fields for acceleration and, thus, a bunched electron beam. To experimentally investigate how the relative time structure of the two beams affects the cooling properties, we have set up a pulsed-beam cooling device by adding a synchronized pulsing circuit to the conventional electron source of the CSRm cooler at Institute of Modern Physics. Using both constant and modulated synchronization between electron pulses and ion bunches, we have measured the effects of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrated the detrimental effect of timing jitter as predicted by space-charge theory and simulations. Our experiment suggests a need for further investigations of specific aspects of bunched cooling such as synchro-betatron coupling and phase dithering effects when using short electron bunches to cool longer ion bunches. However, given the comparatively long IBS lifetime of higher-energy proton storage rings like the EIC, slow dithering could potentially provide an option to save cost on the electron cooler linac.

Wang, Haipeng↗

Final cooling with thick wedges for a muon collider

In the final cooling stages for a muon collider, the transverse emittances are reduced while the longitudinal emittance is allowed to increase. In previous studies, Final 4-D cooling used absorbers within very high field solenoids to cool low-momentum muons. Simulations of the systems did not reach the desired cooling design goals. In this study, we develop and optimize a different conceptual design for the final 4D cooling channel, which is based on using dense wedge absorbers. We used G4Beamline to simulate the channel and Python to generate and analyze particle distributions. We optimized the design parameters of the cooling channel and produced conceptual designs (corresponding to possible starting points for the input beam) which achieve transverse cooling in both x and y by a factor of ~3.5. These channels achieve a lower transverse and longitudinal emittance than the best design previously published.

43 PARTICLE ACCELERATORS↗

Photoinjector Generation of High-Charge Magnetized Beams for Electron-Cooling Applications

The recently announced Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory, will collide high-energy ion-beams and electron beams to pursue nuclear physics research on quark-gluon plasma's. The facility performances (luminosity) would be improved if the ion-beam emittance degradation is mitigated via a phase-space-cooling technique. One potential cooling method uses a bright electron beam to cool the ion beams. The cooling rate for this electron-cooling method depends on the transverse emittance of the cooling electron beam and could benefit from using a beam with significant canonical angular momentum dubbed as a magnetized beam. This research focuses on simulation and experimental generation and characterization of high charge magnetized electron beams with parameters comparable to those required for electron cooling at an electron-ion collider. The experiment uses the 50-MeV photo-injector available at the Fermilab Accelerator Science and Technology (FAST) Facility. The measurements are benchmarked against simulations.

43 PARTICLE ACCELERATORS↗

Tolerance Studies for the IMCC Rectilinear 6D Ionization Cooling Channel

As one of the main proposed future colliders that will enable us to reach energy scales capable of probing Beyond the Standard Model phenomena, muon colliders present unique challenges. To reach the desired luminosity, namely 1, 10, and 20 ab-1 for 3, 10, and 14 TeV, respectively, the six-dimensional emittance of the muon beam needs to be reduced significantly in a process described as muon cooling. The currently proposed system for muon cooling by the International Muon Collider Collaboration involves 6D initial cooling post-muon charge separation through rectilinear channels (A) before and rectilinear channels (B) after muon bunch merge, as well as a final 4D transverse cooling. This work focuses on the former stage of cooling with B rectilinear channels. First, we will compare its cooling performance against the rectilinear channel studied by the Muon Accelerator Program. Then, we do tolerance studies on all B stages, focusing on properties of the Radiofrequency (RF) cavities used in the channels and how they affect 6D emittance and transmission. We will evaluate the impact of these modifications on the overall performance of the rectilinear 6D cooling channel.

Karaaslan, Inci [Chicago U., EFI] (ORCID:000000033↗

Modeling of a Four-Stage Linear Ionization Cooling Channel for a Muon Collider in g4Beamline

A previous study of an eight-stage rectilinear ionization cooling channel in the ICOOL software demonstrated a five-order-of-magnitude reduction in a muon beam’s 6D emittance. In this study, we look to compare the ways ICOOL and Muons, Inc.’s g4Beamline software model ionization cooling by comparing their modeling of the first four stages of this optimized cooling channel constructed in ICOOL. We begin by identifying the parameters used to construct the optimized ionization cooling channel in ICOOL. We then reconstruct this beam in g4Beamline with identical parameter specifications and simulate the cooling of an identical input beam. Finally, we compare the two simulations based on their beam transmission, longitudinal emittance, and transverse emittance along the channel length. Through this process, we demonstrate that G4Beamline accurately reproduces transverse cooling results but predicts systematically different longitudinal emittance evolution while maintaining similar overall cooling performance, reproducing a 97.9% reduction in 6D emittance over four stages.

Keeler, Dominic [Purdue U., West Lafayette] (ORCID↗