Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controller development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

NSTX-U research advancing the physics of spherical tokamaks

Abstract The objectives of NSTX-U research are to reinforce the advantages of STs while addressing the challenges. To extend confinement physics of low- A , high beta plasmas to lower collisionality levels, understanding of the transport mechanisms that set confinement performance and pedestal profiles is being advanced through gyrokinetic simulations, reduced model development, and comparison to NSTX experiment, as well as improved simulation of RF heating. To develop stable non-inductive scenarios needed for steady-state operation, various performance-limiting modes of instability were studied, including MHD, tearing modes, and energetic particle instabilities. Predictive tools were developed, covering disruptions, runaway electrons, equilibrium reconstruction, and control tools. To develop power and particle handling techniques to optimize plasma exhaust in high performance scenarios, innovative lithium-based solutions are being developed to handle the very high heat flux levels that the increased heating power and compact geometry of NSTX-U will produce, and will be seen in future STs. Predictive capabilities accounting for plasma phenomena, like edge harmonic oscillations, ELMs, and blobs, are being tested and improved. In these ways, NSTX-U researchers are advancing the physics understanding of ST plasmas to maximize the benefit that will be gained from further NSTX-U experiments and to increase confidence in projections to future devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of a Nearly Autonomous Management and Control (NAMAC) System for Advanced Reactors (Final Report for ARPA-E Project)

The project formulates a technical basis for, and preliminary development of, a Nearly Autonomous Management and Control (NAMAC) system in advanced reactors. The system is intended to provide recommendations to operators during plant operation. The NAMAC system utilizes simulation-informed, data/knowledge-driven, AI-guided, plant-data-assimilated real-time operating procedures to effectively support the operator in risk-informed management of plant operations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Particle Mass Flow Control and Measurement for High-Temperature Particle Receivers

This work is developing particle flow control and measurement methods for next-generation concentrating solar power systems employing particle-based technologies. Particle receivers are being pursued to provide substantial performance improvements through higher temperatures (>700 °C) for more efficient and cost-effective CSP systems with direct storage for electricity generation, process heating, thermochemistry, and solar fuels production. This specific work will develop technologies that enable more efficient particle receivers and scalable methods to accommodate variable irradiances during commercial on-sun operation. The development of next-generation particle-receiver systems and methods with potentially high consequences for improved performance and cost savings for CSP applications is an appropriate role for the government.

14 SOLAR ENERGY↗

Stabilizing the Grid and Reducing Utility Bills Through Price-Responsive Controls for Heat Pump Water Heaters

The electricity grid is facing increasing challenges in cost-effectively balancing supply and demand. These challenges are exacerbated by increased penetration of photovoltaics, which causes mid-day overproduction, and electrification of gas appliances, which increases peak-period electricity demand. Decarbonization requires shifting building loads from fossil-intensive high-cost times to renewable-intensive low-cost times while maintaining quality of service to occupants. Utilities and ISO’s are investigating new ways of incentivizing this load shifting. One promising method is the use of Highly Dynamic Prices (HDPs). HDPs feature continuously changing prices that reflect real-time grid generation and distribution costs and capacity constraints, and thus incentivize consumers to shift their loads. California’s CPUC CalFUSE proposal and Hawaii’s recent changes demonstrate that electricity tariffs are moving towards this model. For this to work however, loads must have the capability to respond to these prices. Heat pump water heaters (HPWHs) are an ideal device for this purpose because their storage tanks decouple delivery of domestic hot water from electricity consumption. The storage enables control strategies that consume midday solar power to increase the energy stored in the tank, then provide evening peak domestic hot water services using the stored energy. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls for many flexible loads - including HPWHs - in response to HDP. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of the on-board controller in a residential, integrated HPWH . The price-responsive controls a) shift load in ways that consume additional midday solar power to help stabilize the grid and reduce overall emissions, b) ensure that occupants receive equal or better hot water delivery service, and c) minimize the operating cost for each home in the fleet. On the grid level, the resulting shift will reduce utility operating costs and emissions, and can avoid expensive system capacity expansions. The control approach is customized to each home based on typical hot water consumption patterns. HPWH controllers, whether on the device or remotely, will receive a schedule of CTA-2045-B signals or set temperature adjustments customized to the current HDP price schedule and home. Simulation results for a fleet of 148 HPWHs on a summer day in Berkeley, California show cost savings of 29% and high price electricity consumption reductions of 80%, while maintaining full quality of service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unified Universal Control and Coordination of Inverter-Based Resources, and Validation for a PV + Battery Hybrid Plant

As renewable energy deployment grows, hybrid power plants (HPPs) combining photovoltaic (PV) and battery systems must evolve to offer both energy and grid stability services. These systems typically include a mix of grid-following (GFL) and grid-forming (GFM) inverters, presenting unique coordination and control challenges. This Department of Energy–funded project developed and validated a Unified Universal Control and Coordination (UUCC) framework for such PV + battery hybrid plants, enabling seamless and stable operation, including ultrafast black start, autonomous synchronization, and robust frequency and voltage regulation, under different grid conditions. The project significantly advanced the understanding of inverter-based resource (IBR) control by developing and validating three complementary system-level approaches for hybrid GFL/GFM operation: 1. A combined Virtual Resistance (VR)-based GFL and Virtual Oscillator Control (VOC)-based GFM method, where each inverter type is governed by a specialized control strategy. Together, these achieve stable, fast-response coordination, eliminating inrush current and enabling smooth black start and grid synchronization across a wide range of grid strengths. 2. A Deadbeat-based UUCC strategy, which uses discrete-time, switching-cycle-level control for both GFL and GFM inverters. This approach replaces traditional PI/PLL control with a control parameter-free, high-bandwidth framework that supports stable LVRT and instantaneous synchronization under all conditions. 3. A benchmark comparison with Siemens’ commercial GFM microgrid controller, which provided a fast baseline platform. The commercial approach decoupled v & f control was implemented on a commercial microgrid controller.The baseline commercial benchmark helped highlight superior transient response and black start performance offered by the deadbeat and VOC approaches. These technical contributions offer substantial improvements over conventional inverter control schemes, which often rely on slow phase-locked loop (PLL)-based synchronization, require careful control parameters tuning, and prone to unstable in weak grids with GFL inverters and in stiff grid with GFM inverters therefore challenging for hybrid GFL+GFM under all grid conditions. The deadbeat-based UUCC framework enables simpler, faster, and more robust operation of hybrid IBR systems using wide-bandgap (WBG) devices such as SiC power semiconductors. The rapid expansion of hybrid distributed energy resources (DERs), including residential and commercial PV-BESS installations such as Tesla Powerwall, PV with vehicle-to-grid (V2G) capability, and other integrated configurations, presents complex operational challenges for medium-voltage radial distribution feeders. These networks are subject to frequent disturbances such as faults, switching operations, rapid reclosing sequences, and feeder reconfigurations, all of which introduce dynamic stress on IBRs. In addition, planned feeder segmentation and deliberate islanding for resilience will require DERs that can autonomously perform blackstart, establish voltage and frequency references, and resynchronize with the main grid. The advanced deadbeat-based UUCC control and blackstart functionalities developed in this project directly address these requirements, enabling decentralized and autonomous operation of inverter-dominated DERs in distribution systems under a wide range of fault and reconfiguration scenarios. From a public benefit perspective, these innovations enable more reliable and cost-effective integration of renewable energy into distribution networks. The ability to autonomously black start and stabilize grids under varying grid conditions support accelerates recovery from outages and support decentralized resilient energy systems. By reducing system complexity and improving performance, this project lays critical groundwork for future inverter-dominated power grids that are clean, reliable, and accessible to all.

14 SOLAR ENERGY↗

Dynamic P-Q Capability and Abnormal Operation Analysis of a Wind Turbine with Doubly-Fed Induction Generator

After several accidents occurred in wind farms in the United States and around the world, the subsynchronous oscillation (SSO) issues in grid-connected wind farms have gained serious attention. Particularly, these issues have caused significant challenges to wind turbines with a doubly fed induction generator (DFIG) because it is connected to the grid via both its stator and rotor paths. Traditionally, a P-Q capability chart is utilized to assure the safe operation boundary for a synchronous generator. But the energy conversion characteristics of a DFIG wind turbine are completely different. A critical factor to affect the reliable operation of a DFIG wind turbine is the rated current and pulse-width modulation (PWM) saturation constraints of its power converters. These constraint conditions can be affected by the wind turbine rotating speed and grid conditions. However, a detailed study of DFIG P-Q capability from these perspectives has not been conducted, which has hindered adequate understanding of many abnormal wind turbine operations reported in the literature and the development of advanced control technologies to overcome the challenges. The proposed study in this paper considers vector control implementation to DFIG power electronic converters in the dq reference frame, and the models and algorithms developed for the P-Q capability study have addressed specific DFIG power converter constraints that are different from those of a traditional synchronous generator. The paper especially focuses on exploring the dynamic natures of DFIG P-Q capability under uncertain and variable conditions to explore the root causes of many abnormal operations of DFIG wind turbines reported in the literature. The proposed study is validated through an electromagnetic transient simulation model of a grid-connected DFIG wind turbine. The proposed study has the potential to lead to the development of new DFIG control technologies that can help overcome the challenges for many abnormal operations of DFIG wind turbines.

17 WIND ENERGY↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Data-driven building energy modeling with feature selection and active learning for data predictive control

Three gaps impede the development of cost-effective and accurate data-driven building energy modeling/models (DBEM) for energy forecasting and predictive control strategies. Gap 1: data bias is common in building operation data, but this topic is hardly studied in DBEM; Gap 2: high data dimensionality is common in DBEM, but a systematic and scalable methodology is lacking to solve the problem; Gap 3: the interactions between data bias and high dimensionality have not been systematically studied for DBEM and predictive control in buildings. In this work, to address the three gaps mentioned above, we develop a framework that integrates active learning and feature selection for DBEM used for whole building data predictive control (or DPC, which is a branch of model predictive control). The framework provides a systematic methodology and automatic workflow that starts with raw data from building automation systems to the establishment of data-driven energy models for DPC controllers. The developed strategies and framework are evaluated in a virtual testbed based on EnergyPlus and BCVTB. Improved performance and reduced computational complexity are observed from the DBEM built with the developed framework, as well as the DPC controller based on that DBEM, indicating the effectiveness of the developed framework.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Driven Modeling of a High Capacity Cryogenic System for Control Optimization

The Cryogenic Moderator System (CMS) is responsible for maintaining a steady flow of cold neutrons for numerous physics experiments at the Spallation Neutron Source (SNS) in Oak Ridge National Laboratory (ORNL). Sudden losses in beam power, known as beam trips, cause a major disturbance to the CMS due to large step changes in cooling demands. Ongoing efforts on upgrading the neutron beam power from 1.4 to 2.0MW are expected to generate larger transients that can further strain the CMS subsystems if they are not properly controlled. To manage such disturbances, four flow valves and one electric heater are adjusted by five decentralized proportional-integral-derivative (PID) controllers. However, the original PID gains were calibrated empirically based only on tracking performance and not based on disturbance rejection. To address this issue without compromising current CMS operations, a control-oriented model was developed to recalibrate the PID controllers offline. The zero-dimensional (0-D) model was based on simple physics-based principles and data-driven system identification techniques. The CMS was broken into several subsystems for analysis, each of which corresponds to a parametric model tied to the thermodynamic states of the working fluid. The model parameters were identified using the nonlinear least squares method where the residuals were calculated from available sensor data. Simulation results show that the proposed model can capture the dynamics of the CMS at steady state and during beam trips.

Maldonado Puente, Bryan↗

Pressure feedback control of electro-hydraulic actuators using fixed displacement hydraulic machines

This paper presents the development of a control strategy for Electro-Hydraulic Actuator (EHA) systems based on fixed displacement hydraulic machines. Although some previous studies on EHAs show benefits in terms of energy efficiency and regeneration capability compared to conventional hydraulic systems, few studies focus on the dynamic performance of EHAs. Unlike traditional valve-controlled systems, an EHA based on a fixed displacement pump typically relies on variation of the electric motor shaft speed to control the actuator velocity. This study shows that pressure feedback can be used to control the speed of the electric machine, thus achieving the required actuator/machine dynamic response. A simulation model is developed by including the EM, the hydraulic system, and the actuation system, which can give a realistic prediction of the EHA performance for a typical duty cycle. An open-circuit EHA previously proposed by the authors is used to validate the control strategy, and the simulation results show superior dynamic performance, exhibiting a reduction in response time and oscillatory behavior, compared to a feedforward EHA controller. Following the method presented in this study, it is possible to design a controller with a pressure feedback strategy for EHA systems with different size and actuation requirements

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent Surrogate Model Development: Boosting Computational Efficiency for Autonomous Control of Advanced Reactors

Advanced reactors promise enhanced safety, greater efficiency, and waste reductions. To fully realize these benefits, it is crucial to address the need for autonomous or semi-autonomous control systems that require fewer operators. This research primarily supports the MARVEL autonomous control system, which requires real-time operation. However, the current RELAP5 reactor thermal hydraulic transient simulation is excessively time-consuming. Therefore, this study aims to leverage deep learning techniques to develop a surrogate model, providing a more efficient and accurate alternative for real-time performance. The model was trained using a combination of one-timestep prediction and scheduled sampling. It was then used for recursive prediction of the reactor state. This developed surrogate model significantly improves computational efficiency, achieving a 12 times acceleration.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Development of prechamber enabled mixing-controlled combustion strategy for ultra-low methane emissions from lean burn natural gas engines

This numerical study explores the optimization of Prechamber Enabled Mixing-Controlled Combustion (PC-MCC) using natural gas in heavy-duty engines, aiming to enhance combustion efficiency to minimize methane slip and NOx emissions. The approach involves a prechamber ignition system, distinct from conventional spark ignition (SI) systems, to initiate combustion of direct injected natural gas. By leveraging the robust ignition characteristics of the prechamber, the PC-MCC method demonstrates significant potential in achieving efficient combustion akin to diesel engines but with lower greenhouse gas emissions. The research evaluates the effects of various geometric and operational parameters on the combustion process and emissions, including prechamber volume, nozzle diameter, direct injector (DI) geometry, and engine operating strategies. Computational Fluid Dynamics (CFD) simulations are utilized, focusing on a heavy-duty, single-cylinder engine modeled after the Caterpillar C9.3B engine. Key findings indicate that a prechamber volume of 3 cc, coupled with a nozzle diameter of 2.75 mm for two prechamber holes, strikes an optimal balance between combustion efficiency and emissions reduction. This configuration ensures robust combustion across a range of operating conditions while maintaining methane slip within targeted limits. Further investigation into DI geometry shows the significance of the injector umbrella angle and nozzle diameter in shaping the fuel-air mixing and combustion dynamics. An umbrella angle of 130° and a nozzle diameter of 300 microns are identified as optimal, promoting rapid and efficient combustion with minimized methane and NOx emissions. The study also investigates the impact of injection timing and pressure, highlighting their roles in controlling combustion timing and influencing emissions levels. Advanced injection timing is found to be crucial in achieving the desired low methane slip, whereas retarded injection timing assists to reduce NOx emissions while having a slight increase in methane emissions. Operating strategies incorporating various levels of Exhaust Gas Recirculation (EGR) are assessed for their effectiveness in further reducing emissions. The research demonstrates that a judicious combination of internal hot EGR and careful calibration of DI pressure and SOI timing can achieve significant reductions in NOx emissions while keeping methane slip under control. Specifically, an internal EGR level of 15%–25%, combined with DI pressures of 200–300 bar and injection timings at or after top dead center, is recommended. These findings contribute valuable insights into the development of advanced combustion techniques for natural gas engines, offering a viable pathway to reduce methane slip without compromising engine efficiency or performance. The PC-MCC system presents a promising solution for the future of heavy-duty natural gas engine technology to reduce methane emissions.

Nsaif, Osama↗

Developing More Efficient Wind Turbines: A Survey of Control Challenges and Opportunities

Wind energy has received considerable attention during the past two decades, owing to its vital role in battling both the energy crisis and global climate change. Wind energy has grown to become the most significant nonconventional renewable energy source. Today, modern wind turbines (WTs) are controlled to offer several functionalities that improve their flexibility at a level similar to conventional power sources. However, until now, there have been few reports in the literature summarizing and listing WT control concepts to encourage industry and academia to pursue improvements in developing more efficient WTs and bridge the gap between businesses and universities. Hence, this article focuses on a thoughtful investigation into developing better and more efficient WTs, detailing different issues involved in wind energy generation, such as WT components, control systems, operational modes, and, especially, new research and development trends.

17 WIND ENERGY↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

Model-free control for frequency response support in microgrids utilizing wind turbines

Islanded microgrids integrated with renewable energy resources bring additional challenges to the primary frequency control due to their power-electronic interfaced generations. Developing an efficient control strategy for inertia emulation and frequency response support of microgrids is becoming an important issue. Wind turbine dynamics, however, will degrade the emulated inertial and primary responses with most traditional control strategies. On the other hand, compensation methods often require the knowledge of system models at the design stage and state estimation for feedback once deployed online. To overcome these challenges, this paper explores a model-free control (MFC) strategy to emulate the desired inertia and support the frequency response of a diesel-wind microgrid system. Additionally, the proposed MFC strategy utilizes a model reference concept to obtain guaranteed inertial response and improve the frequency response of microgrids. This work considers different control strategies with different operating points. The proposed controller is implemented and verified using the modified 33-bus full nonlinear model of the three-phase diesel-wind system in Simulink. Simulation results demonstrate the improved frequency response by precisely emulating the desired inertia using the MFC strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and Evaluation of Occupancy-Aware Model Predictive Control for Residential Building Energy Efficiency and Occupant Comfort

The residential sector accounts for 25% of global primary energy consumption. Two methods have previously been proposed to reduce residential energy use associated with the provision of occupant thermal comfort: 1. Occupancy-based HVAC control, operating systems only during confirmed occupancy, and 2. model predictive control (MPC), harnessing a mathematical model and forecasts to find optimal operating strategies. Previous studies estimate the average energy savings of the two methods individually in the range of 21% and 16%, respectively. The research presented herein was carried out to evaluate the energy savings potential in residential buildings by combining both approaches across different climates, house vintages, and occupancy patterns. Occupancy and eight different physical modalities (e.g. CO2 and VOC) data were collected from five homes for time periods of 4–9 weeks. Collected data sets were used to train occupancy prediction models suggested by an extensive literature survey of occupancy model types. The trained prediction models were combined with MPC and detailed EnergyPlus building simulation models to evaluate residential building performance in terms of annual energy savings and thermal comfort, along with discomfort exceedance metrics. Multiple home types and regions were analyzed to understand regional and climate-dependent potential. Based on actual field data, the occupancy models had a prediction inaccuracy between 8% and 35% across the investigated homes. Average occupancy for the collected data ranged from 56% to 86%, a typical range reported in the literature. Building simulations were conducted for three control scenarios: conventional thermostatic control, occupancy-based, and occupancy-based MPC. The results indicate that all advanced strategies improve upon the conventional control, with some scenarios cutting energy use in half with only occasional incurrence of discomfort. The findings indicate that occupancy-aware model predictive residential building control has the potential to drastically reduce energy use and associated emissions while maintaining occupant comfort for both new and existing buildings.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Gaussian process regression for radiological contamination mapping- Applied to optimal motion planning for mobile sensor platforms [Slides]

Want to achieve best representative characterization of the entire area efficiently and accurately-Unmanned aerial/ground vehicles (UAV/UGVs) for contamination mapping. Some major challenges include: Limited battery life (move smart), Human operated (fully autonomous controls) and Many measurements (predictive mapping capabilities). The objective: Develop fully autonomous controls for mobile sensor platforms to improve efficiency and maintain performance.

61 RADIATION PROTECTION AND DOSIMETRY↗