A new approach to active vibration isolation for microgravity space experiments

A new method was developed to design an active vibration isolation system for microgravity space experiments. This method yields the required controller transfer functions for a specified transmissibility ratio. Hence, it is a straightforward task to guarantee that the desired vibration isolation performance is achieved at each frequency. The theory for such a controller design was presented by considering a single degree of freedom system. In addition, the magnitude of the input required by the new method has been found to be less than that used by a standard phase lead/lag compensator.

Sinha, Alok↗

A new approach to controller design for microgravity isolation systems

A new method has been developed to design an active vibration isolation system for microgravity space experiments. This method yields the required controller transfer functions for a specified transmissibility. Hence, it is a straightforward task to guarantee that the desired vibration isolation performance is achieved at each frequency. The theory for such a controller design has been presented by considering a single degree of freedom system. The magnitude of the control force required by the new method has been found to be less than that used by a standard phase lead/lag compensator.

Sinha, A.↗

Stochastic robustness synthesis for a benchmark problem

Stochastic robustness analysis guides the synthesis of robust linear quadratic Gaussian (LQG) regulators for a benchmark control problem. Probabilities of exceeding allowable design limits, including stability, setting time, and control usage, are estimated by Monte Carlo evaluation. Robust, low-gain compensators that fulfill objectives are designed by numerically minimizing quadratic functions of these probabilities. The method is straightforward and makes use of uncomplicated design principles.

Stengel, Robert F.↗

Delivery of cardiopulmonary resuscitation in the microgravity environment

The microgravity environment presents several challenges for delivering effective cardiopulmonary resuscitation (CPR). Chest compressions must be driven by muscular force rather than by the weight of the rescuer's upper torso. Airway stabilization is influenced by the neutral body posture. Rescuers will consist of crew members of varying sizes and degrees of physical deconditioning from space flight. Several methods of CPR designed to accommodate these factors were tested in the one G environment, in parabolic flight, and on a recent shuttle flight. Methods: Utilizing study participants of varying sizes, different techniques of CPR delivery were evaluated using a recording CPR manikin to assess adequacy of compressive force and frequency. Under conditions of parabolic flight, methods tested included conventional positioning of rescuer and victim, free floating 'Heimlich type' compressions, straddling the patient with active and passive restraints, and utilizing a mechanical cardiac compression assist device (CCAD). Multiple restrain systems and ventilation methods were also assessed. Results: Delivery of effective CPR was possible in all configurations tested. Reliance on muscular force alone was quickly fatiguing to the rescuer. Effectiveness of CPR was dependent on technique, adequate restraint of the rescuer and patient, and rescuer size and preference. Free floating CPR was adequate but rapidly fatiguing. The CCAD was able to provide adequate compressive force but positioning was problematic. Conclusions: Delivery of effective CPR in microgravity will be dependent on adequate resuer and patient restraint, technique, and rescuer size and preference. Free floating CPR may be employed as a stop gap method until patient restraint is available. Development of an adequate CCAD would be desirable to compensate for the effects of deconditioning.

Barratt, M. R.↗

Precise Stabilization of the Optical Frequency of WGMRs

Crystalline whispering gallery mode resonators (CWGMRs) made of crystals with axial symmetry have ordinary and extraordinary families of optical modes. These modes have substantially different thermo-refractive constants. This results in a very sharp dependence of differential detuning of optical frequency on effective temperature. This frequency difference compared with clock gives an error signal for precise compensation of the random fluctuations of optical frequency. Certain crystals, like MgF2, have turnover points where the thermo-refractive effect is completely nullified. An advantage for applications using WGMRs for frequency stabilization is in the possibility of manufacturing resonators out of practically any optically transparent crystal. It is known that there are crystals with negative and zero thermal expansion at some specific temperatures. Doping changes properties of the crystals and it is possible to create an optically transparent crystal with zero thermal expansion at room temperature. With this innovation s stabilization technique, the resultant WGMR will have absolute frequency stability The expansion of the resonator s body can be completely compensated for by nonlinear elements. This results in compensation of linear thermal expansion (see figure). In three-mode, the MgF2 resonator, if tuned at the turnover thermal point, can compensate for all types of random thermal-related frequency drift. Simplified dual-mode method is also available. This creates miniature optical resonators with good short- and long-term stability for passive secondary frequency ethalon and an active resonator for active secondary frequency standard (a narrowband laser with long-term stability).

Savchenkov, Anatoliy↗

Astrometric "Core-shifts" at the Highest Frequencies

We discuss the application of a new VLBI astrometric method named "Source/Frequency Phase Referencing" to measurements of "core-shifts" in radio sources used for geodetic observations. We detail the reasons that astrometrical observations of 'core-shifts' have become critical in the era of VLBI2010. We detail how this new method allows the problem to be addressed at the highest frequencies and outline its superior compensation of tropospheric errors.

Rioja, Maria↗

Thermal Infrared Radiometric Calibration of the Entire Landsat 4, 5, and 7 Archive (1982-2010)

Landsat's continuing record of the thermal state of the earth's surface represents the only long term (1982 to the present) global record with spatial scales appropriate for human scale studies (i.e., tens of meters). Temperature drives many of the physical and biological processes that impact the global and local environment. As our knowledge of, and interest in, the role of temperature on these processes have grown, the value of Landsat data to monitor trends and process has also grown. The value of the Landsat thermal data archive will continue to grow as we develop more effective ways to study the long term processes and trends affecting the planet. However, in order to take proper advantage of the thermal data, we need to be able to convert the data to surface temperatures. A critical step in this process is to have the entire archive completely and consistently calibrated into absolute radiance so that it can be atmospherically compensated to surface leaving radiance and then to surface radiometric temperature. This paper addresses the methods and procedures that have been used to perform the radiometric calibration of the earliest sizable thermal data set in the archive (Landsat 4 data). The completion of this effort along with the updated calibration of the earlier (1985 1999) Landsat 5 data, also reported here, concludes a comprehensive calibration of the Landsat thermal archive of data from 1982 to the present

Schott, John R.↗

The Extrapolation of High Altitude Solar Cell I(V) Characteristics to AM0

The high altitude aircraft method has been used at NASA GRC since the early 1960's to calibrate solar cell short circuit current, ISC, to Air Mass Zero (AMO). This method extrapolates ISC to AM0 via the Langley plot method, a logarithmic extrapolation to 0 air mass, and includes corrections for the varying Earth-Sun distance to 1.0 AU and compensating for the non-uniform ozone distribution in the atmosphere. However, other characteristics of the solar cell I(V) curve do not extrapolate in the same way. Another approach is needed to extrapolate VOC and the maximum power point (PMAX) to AM0 illumination. As part of the high altitude aircraft method, VOC and PMAX can be obtained as ISC changes during the flight. These values can then the extrapolated, sometimes interpolated, to the ISC(AM0) value. This approach should be valid as long as the shape of the solar spectra in the stratosphere does not change too much from AMO. As a feasibility check, the results are compared to AMO I(V) curves obtained using the NASA GRC X25 based multi-source simulator. This paper investigates the approach on both multi-junction solar cells and sub-cells.

Snyder, David B.↗

First Order Reliability Application and Verification Methods for Semistatic Structures

Escalating risks of aerostructures stimulated by increasing size, complexity, and cost should no longer be ignored by conventional deterministic safety design methods. The deterministic pass-fail concept is incompatible with probability and risk assessments, its stress audits are shown to be arbitrary and incomplete, and it compromises high strength materials performance. A reliability method is proposed which combines first order reliability principles with deterministic design variables and conventional test technique to surmount current deterministic stress design and audit deficiencies. Accumulative and propagation design uncertainty errors are defined and appropriately implemented into the classical safety index expression. The application is reduced to solving for a factor that satisfies the specified reliability and compensates for uncertainty errors, and then using this factor as, and instead of, the conventional safety factor in stress analyses. The resulting method is consistent with current analytical skills and verification practices, the culture of most designers, and with the pace of semistatic structural designs.

Verderaime, Vincent↗

Flight calibration of compensated and uncompensated pitot-static airspeed probes and application of the probes to supersonic cruise vehicles

Static pressure position error calibrations for a compensated and an uncompensated XB-70 nose boom pitot static probe were obtained in flight. The methods (Pacer, acceleration-deceleration, and total temperature) used to obtain the position errors over a Mach number range from 0.5 to 3.0 and an altitude range from 25,000 feet to 70,000 feet are discussed. The error calibrations are compared with the position error determined from wind tunnel tests, theoretical analysis, and a standard NACA pitot static probe. Factors which influence position errors, such as angle of attack, Reynolds number, probe tip geometry, static orifice location, and probe shape, are discussed. Also included are examples showing how the uncertainties caused by position errors can affect the inlet controls and vertical altitude separation of a supersonic transport.

Webb, L. D.↗

Precision signal power measurement

Accurate estimation of signal power is an important Deep Space Network (DSN) consideration. Ultimately, spacecraft power and weight is saved if no reserve transmitter power is needed to compensate for inaccurate measurements. Spectral measurement of the received signal has proved to be an effective method of estimating signal power over a wide dynamic range. Furthermore, on-line spectral measurements provide an important diagnostic tool for examining spacecraft anomalies. Prototype equipment installed at a 64-m-diameter antenna site has been successfully used to make measurements of carrier power and sideband symmetry of telemetry signals received from the Mariner Mars 1971 spacecraft.

Winkelstein, R.↗

A methodology for designing robust multivariable nonlinear feedback control systems

This paper presents an outline of a methodology for the design of nonlinear dynamic compensators for nonlinear multivariable systems with guarantees of closed-loop stability, robustness, and performance. The method is an extension of the Linear-Quadratic-Gaussian with Loop-Transfer-Recovery (LQG/LTR) methodology for linear systems, thus hinging upon the idea of constructing an approximate nonlinear inverse operator for the plant. A major feature of the method is a unification of both the state-space and Input-Output formulations. The major results of the paper are: (1) Properties of the solution of certain optimal control problems; (2) New results on nonlinear estimation, including a new nonlinear observer with certain guaranteed properties; (3) The Loop Operator Recovery (LOR) procedure, and (4) Inclusion of command-following and disturbance rejection with a goal of a closed-loop stable, robust system.

Grunberg, D. B.↗

Conceptual design of pointing control systems for space station gimballed payloads

A conceptual design of the control system for Payload Pointing Systems (PPS) is developed using classic Proportional-Integral-Derivatives (PID) techniques. The major source of system pointing error is due to the disturbance-rich environment of the space station in the form of gimbal baseplate motions. These baseplate vibrations are characterized using Fast Fourier Transform (FFT) techniques. Both time domain and frequency domain dynamic models are developed to assess control system performance. Three basic methods exist for the improvement of PPS pointing performance: increase control system bandwidth, add Image Motion Compensation, and/or reduce (or change) the baseplate disturbance environment.

Hughes, Robert O.↗

Reaction-compensation technology for microgravity laboratory robots

Robots operating in the microgravity environment of an orbiting laboratory should be capable of manipulating payloads such that the motion of the robot does not disturb adjacent experiments. The current results of a NASA Lewis Research Center technology program to develop smooth, reaction-compensated manipulation based on both mechanism technology and trajectory planning strategies are present. Experimental validation of methods to reduce robot base reactions through the use of redundant degrees of freedom is discussed. Merits of smooth operation roller-driven robot joints for microgravity manipulators are also reviewed.

Rohn, Douglas A.↗

Gravity anomalies, compensation mechanisms, and the geodynamics of western Ishtar Terra, Venus

Pioneer Venus line-of-sight orbital accelerations were utilized to calculate the geoid and vertical gravity anomalies for western Ishtar Terra on various planes of altitude z sub 0. The apparent depth of isostatic compensation at z sub 0 = 1400 km is 180 + or - 20 km based on the usual method of minimum variance in the isostatic anomaly. An attempt is made here to explain this observation, as well as the regional elevation, peripheral mountain belts, and inferred age of western Ishtar Terra, in terms of one or three broad geodynamic models.

Grimm, Robert E.↗

Reaction-compensation technology for microgravity laboratory robots

Robots operating in the microgravity environment of an orbiting laboratory should be capable of manipulating payloads such that the motion of the robot does not disturb adjacent experiments. The current results of a NASA Lewis Research Center technology program to develop smooth, reaction-compensated manipulation based on both mechanism technology and trajectory planning strategies are present. Experimental validation of methods to reduce robot base reactions through the use of redundant degrees of freedom is discussed. Merits of smooth operation roller-driven robot joints for microgravity manipulators are also reviewed.

Rohn, Douglas A.↗

Robust Control for Microgravity Vibration Isolation using Fixed Order, Mixed H2/Mu Design

Many space-science experiments need an active isolation system to provide a sufficiently quiescent microgravity environment. Modern control methods provide the potential for both high-performance and robust stability in the presence of parametric uncertainties that are characteristic of microgravity vibration isolation systems. While H2 and H(infinity) methods are well established, neither provides the levels of attenuation performance and robust stability in a compensator with low order. Mixed H2/H(infinity), controllers provide a means for maximizing robust stability for a given level of mean-square nominal performance while directly optimizing for controller order constraints. This paper demonstrates the benefit of mixed norm design from the perspective of robustness to parametric uncertainties and controller order for microgravity vibration isolation. A nominal performance metric analogous to the mu measure, for robust stability assessment is also introduced in order to define an acceptable trade space from which different control methodologies can be compared.

Whorton, Mark↗

Robust Control for The G-Limit Microgravity Vibration Isolation System

Many microgravity science experiments need an active isolation system to provide a sufficiently quiescent acceleration environment. The g-LIMIT vibration isolation system will provide isolation for Microgravity Science Glovebox experiments in the International Space Station. While standard control system technologies have been demonstrated for these applications, modern control methods have the potential for meeting performance requirements while providing robust stability in the presence of parametric uncertainties that are characteristic of microgravity vibration isolation systems. While H2 and H infinity methods are well established, neither provides the levels of attenuation performance and robust stability in a compensator with low order. Mixed H2/mu controllers provide a means for maximizing robust stability for a given level of mean-square nominal performance while directly optimizing for controller order constraints. This paper demonstrates the benefit of mixed norm design from the perspective of robustness to parametric uncertainties and controller order for microgravity vibration isolation. A nominal performance metric analogous to the mu measure for robust stability assessment is also introduced in order to define an acceptable trade space from which different control methodologies can be compared.

Whorton, Mark S.↗