Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “color sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Electrochemical techniques and mechanisms for the corrosion of metals and alloys in sub- and supercritical aqueous systems

Corrosion has become a decisive factor hindering supercritical water technologies' long-cycle, safe implementation. Electrochemical experiments performed in supercritical aqueous systems can capture essential, real-time information about the micro/nanoscale processes of corrosion and their kinetics. As a starting point, this paper first summarizes the critical chemical properties of supercritical aqueous systems and analyzes their role in determining the duality of corrosion mechanisms (whether electrochemical or chemical micro-processes predominate). Next, it reviews the available electrochemical techniques such as pH sensors, electrochemical noise measurements, and related applications for quantitatively elaborating the corrosion issues in supercritical aqueous systems. With thick and heavy colors, a series of mechanistic models, such as the mixed potential model and the coupled environment models were introduced from the fundamental theories to the related applications, which have been applied widely in ambient and subcritical aqueous systems and exhibit great values and potential to be employed in high-density supercritical water environments. The passivity, depassivation, and passivity breakdown of metals and alloys in terms of the Point Defect Model (PDM) were also successfully implemented and discussed. Further, the newly built SCW_PDM describes the film growth kinetics at the atomic level of metals and alloys in supercritical water and is being developed to quantitatively analyze and resolve a series of corrosion issues such as the passivity breakdown and the stress corrosion cracking that occur in supercritical aqueous systems. This review is helpful by promoting the development of the electrochemical corrosion theory in supercritical aqueous systems and by identifying corrosion prevention and control methods for the safe implementation of relevant supercritical water technologies.

36 MATERIALS SCIENCE↗

Functional organic materials for electronics industries

Topics closely related with organic, high molecular weight material synthesis are discussed. These are related to applications such as display, recording, sensors, semiconductors, and I.C. correlation. New materials are also discussed. General principles of individual application are not included. Materials discussed include color, electrochromic, thermal recording, organic photoconductors for electrophotography, and photochromic materials.

Shibayama, K.↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (∼13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ∼100 μm spot on a target at a working distance of ∼48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ∼370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ∼ 800 – 4000 cm−1 (250 to 273 nm) and the fluorescence region (274 to ∼370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

Rohit Bhartia↗

The first 300 sols of the SHERLOC investigation on the Mars 2020 rover

The Mars2020 mission is NASA’s latest flagship mission to Mars. The spacecraft launched in July 2020, and landed in Jezero crater on February 18, 2021 at the Octavia Butler Landing site. The rocks and sediments of Jezero crater have been argued to have preserved records of past, potentially habitable environments. The mission is characterizing the field site by analyzing chemistry, looking for organics and searching for potential biosignatures. The Scanning Habitable Environments with Ra-man and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm mounted instrument. SHERLOC combines imaging with UV resonance Raman and native deep UV fluorescence spectroscopy to identify potential biosignatures and understand the aqueous history of the Jezero Region. WATSON (Wide Angle Topographic Sensor for Operations and eNgineering), a refight of the Mars Hand Lens Imager (MAHLI) on the Curiosity rover is capable of color imaging over a wide range of resolutions (from infinity to 13.1 micron/pixel) and is used for both science and engineering. A second imager, the Autofocusing Con-textual Imager (ACI), produces gray scale images at 10.1 micron/pixel resolution at a 48 mm range.

A. E. Murphy↗

RGB wavefront sensor for turbulence mitigation

A compact adaptive optics system for long-range horizontal paths imaging that improves degraded images. The system uses a filter that corresponds to the three colors in a typical color detector element, one or more optic elements, a deformable mirror, and a detector. Focus errors, due to turbulence, in the image recorded by the detector element show up as image shifts in the three distinct color images. The shifts and statistics of these shifts between these simultaneous images are used to create control signals for the deformable mirror resulting in a compact adaptive optic system for horizontal paths without need for a point source located at the distance scene being imaged. Analysis of the relative pixel shifts in various regions of the image provides third order statistics revealing tip/tilt and additional Zernikes modes that are used to control a deformable mirror without the need for a guide star/point-source.

O'Neill, Mary Dominique↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗

Chemochromic Hydrogen Leak Detectors

At NASA, hydrogen safety is a key concern for space shuttle processing. Leaks of any level must be quickly recognized and addressed due to hydrogen s lower explosion limit. Chemo - chromic devices have been developed to detect hydrogen gas in several embodiments. Because hydrogen is odorless and colorless and poses an explosion hazard, there is an emerging need for sensors to quickly and accurately detect low levels of leaking hydrogen in fuel cells and other advanced energy- generating systems in which hydrogen is used as fuel. The device incorporates a chemo - chromic pigment into a base polymer. The article can reversibly or irreversibly change color upon exposure to hydrogen. The irreversible pigment changes color from a light beige to a dark gray. The sensitivity of the pigment can be tailored to its application by altering its exposure to gas through the incorporation of one or more additives or polymer matrix. Furthermore, through the incorporation of insulating additives, the chemochromic sensor can operate at cryogenic temperatures as low as 78 K. A chemochromic detector of this type can be manufactured into any feasible polymer part including injection molded plastic parts, fiber-spun textiles, or extruded tapes. The detectors are simple, inexpensive, portable, and do not require an external power source. The chemochromic detectors were installed and removed easily at the KSC launch pad without need for special expertise. These detectors may require an external monitor such as the human eye, camera, or electronic detector; however, they could be left in place, unmonitored, and examined later for color change to determine whether there had been exposure to hydrogen. In one type of envisioned application, chemochromic detectors would be fabricated as outer layers (e.g., casings or coatings) on high-pressure hydrogen storage tanks and other components of hydrogen-handling systems to provide visible indications of hydrogen leaks caused by fatigue failures or other failures in those systems. In another type of envisioned application, chemochromic detectors of this type could be optoelectronically instrumented for monitoring to provide measured digital indications of color changes indicative of the presence of hydrogen.

Roberson, Luke↗

SeaWiFS technical report series. Volume 13: Case studies for SeaWiFS calibration and validation, part 1

Although the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Calibration and Validation Program relies on the scientific community for the collection of bio-optical and atmospheric correction data as well as for algorithm development, it does have the responsibility for evaluating and comparing the algorithms and for ensuring that the algorithms are properly implemented within the SeaWiFS Data Processing System. This report consists of a series of sensitivity and algorithm (bio-optical, atmospheric correction, and quality control) studies based on Coastal Zone Color Scanner (CZCS) and historical ancillary data undertaken to assist in the development of SeaWiFS specific applications needed for the proper execution of that responsibility. The topics presented are as follows: (1) CZCS bio-optical algorithm comparison, (2) SeaWiFS ozone data analysis study, (3) SeaWiFS pressure and oxygen absorption study, (4) pixel-by-pixel pressure and ozone correction study for ocean color imagery, (5) CZCS overlapping scenes study, (6) a comparison of CZCS and in situ pigment concentrations in the Southern Ocean, (7) the generation of ancillary data climatologies, (8) CZCS sensor ringing mask comparison, and (9) sun glint flag sensitivity study.

Hooker, Stanford B.↗

Fiber-Optic Ammonia Sensors

Reversible, colorimetric fiber-optic sensors are undergoing development for use in measuring concentrations of ammonia in air at levels relevant to human health [0 to 50 parts per million (ppm)]. A sensor of this type includes an optical fiber that has been modified by replacing a portion of its cladding with a polymer coat that contains a dye that reacts reversibly with ammonia and changes color when it does so. The change in color is measured as a change in the amount of light transmitted from one end of the fiber to the other. Responses are reversible and proportional to the concentration of ammonia over the range from 9 to 175 ppm and in some cases the range of reversibility extends up to 270 ppm. The characteristic time for the response of a sensor to rise from 10 to 90 percent of full scale is about 25 seconds. These sensors are fully operational in pure carbon dioxide and are not adversely affected by humidity. This work was done by Michael T. Carter

Carter, Michael T.↗

Uncertainty Assessment of the SeaWiFS On-Orbit Calibration

Ocean color climate data records require water-leaving radiances with 5% absolute and 1% relative accuracies as input. Because of the amplification of any sensor calibration errors by the atmospheric correction, the 1% relative accuracy requirement translates into a 0.1% long-term radiometric stability requirement for top-of-the atmosphere radiances. The rigorous on-orbit calibration program developed and implemented for SeaWiFS by the NASA Ocean Biology Processing Group (OBPG) Calibration and Validation Team (CVT) has allowed the CVT to maintain the stability of the radiometric calibration of SeaWiFS at 0.13% or better over the mission. The uncertainties in the resulting calibrated top-of-the-atmosphere (TOA) radiances can be addressed in terms of accuracy (biases in the measurements), precision (scatter in the measurements), and stability (repeatability of the measurements). The calibration biases of lunar observations relative to the USGS RObotic Lunar Observatory (ROLO) photometric model of the Moon are 2-3%. The biases from the vicarious calibration against the Marine Optical Buoy (MOBY) are 1-2%. The precision of the calibration derived from the solar calibration signal-tonoise ratios are 0.16%, from the lunar residuals are 0.13%, and from the vicarious gains are 0.10%. The long-term stability of the TOA radiances, derived from the lunar time series, is 0.13%. The stability of the vicariouslycalibrated TOA radiances, incorporating the uncertainties in the MOBY measurements and the atmospheric correction, is 0.30%. These results allow the OBPG to produce climate data records from the SeaWiFS ocean color data.

Eplee, Robert E., Jr.↗

Radiometric comparison of two ocean color scanners Nimbus-7/CZCS and OSTA-1/OCE

On November 14, 1981 the area around the Gibraltar Strait was observed by two different ocean color scanners: a Space Shuttle-borne Ocean Color Experiment and Coastal Zone Color Scanner (Nimbus-7/CZCS). This presented an opportunity to study the gradual degradation of the CZCS sensitivity by comparing the two sensors. Upwelling radiances from eleven targets were compared. The results of the analysis indicate that the CZCS sensitivities at channels 1 and 2 are down to 65 percent and 78 percent. However, the evidence for channels 3 and 4 deterioration could not be found.

Kim, H. H.↗

Thinking Outside of the Blue Marble: Novel Ocean Applications Using the VIIRS Sensor

While planning for future space-borne sensors will increase the quality, quantity, and duration of ocean observations in the years to come, efforts to extend the limits of sensors currently in orbit can help shed light on future scientific gains as well as associated uncertainties. Here, we present several applications that are unique to the polar orbiting Visual Infrared Imaging Radiometer Suite (VIIRS), each of which challenge the threshold capabilities of the sensor and provide lessons for future missions. For instance, while moderate resolution polar orbiters typically have a one day revisit time, we are able to obtain multiple looks of the same area by focusing on the extreme zenith angles where orbital views overlap, and pair these observations with those from other sensors to create pseudo-geostationary data sets. Or, by exploiting high spatial resolution (imaging) channels and analyzing patterns of synoptic covariance across the visible spectrum, we can obtain higher spatial resolution bio-optical products. Alternatively, non-traditional products can illuminate important biological interactions in the ocean, such as the use of the Day-Night-Band to provide some quantification of phototactic behavior of marine life along light polluted beaches, as well as track the location of marine fishing vessel fleets along ocean fronts. In this talk, we explore ways to take full advantage of the capabilities of existing sensors in order to maximize insights for future missions.

ocean color↗

150 Shades of Green: Using the Full Spectrum of Remote Sensing Reflectance to Elucidate Color Shifts in the Ocean

This article proposes a simple and intuitive classification system by which to define full spectral remote sensing reflectance (Rrs(λ)) data with a quantitative output that enables a more manageable handling of spectral information for aquatic science applications. The weighted harmonic mean of the Rrs(λ) wavelengths outputs an Apparent Visible Wavelength (in units of nanometers), representing a one-dimensional geophysical metric of color that is inherently correlated to spectral shape. This dimensionality reduction of spectral information combined with the output along a continuum of wavelength values offers a robust and user-friendly means to describe and analyze spectral Rrs(λ) in terms of spatial and temporal trends and variability. The uncertainty in the algorithm's estimation of spectral shape is demonstrated on a global scale, in addition to the utility of the algorithm to discern spectral-spatial-temporal trends in the ocean, on a per-pixel basis for the entire 22 year continuous ocean color (SeaWiFS and MODIS-Aqua) time-series. This technique can be applied to datasets of varying multi- and hyper-spectral resolutions, providing continuity between heritage and future satellite sensors, and further enabling an effective means of elucidating similarities or differences in complex spectral signatures within the constraints of two dimensions. This straightforward means of conceptualizing multi-dimensional variability can help maximize the potential of the spectral information embedded in remote sensing data.

ocean color↗

Big Cypress Water Resources: Using Earth Observations to Assess Water Quality in Big Cypress Reservation, FL

Upstream agricultural development and runoff are driving harmful algal blooms in the Big Cypress Reservation. The Seminole Tribe of Florida Environmental Resource Management Department monitors water quality in the Big Cypress Reservation, located on the north end of Big Cypress National Preserve. The Environmental Resource Management Department aims to incorporate Earth observations into its investigative approach, which consists of Geographic Information Systems and in situ water sampling. We assessed the feasibility of using Earth observations to measure harmful algal blooms over time and identify vulnerable areas. We analyzed data from multiple remote sensing platforms and sensors, including Landsat 8 Thermal Infrared Spectrometer(TIRS), Landsat 9 TIRS-2, Landsat 9 Operational Land Imager 2, Sentinel-2 MultiSpectral Instrument, and Sentinel-3 Ocean and Land Color Instrument. We determined that it was challenging to use Sentinel-3, Landsat 8, and Landsat 9 imagery for monitoring the canals within the Reservation, and that Sentinel-2 was the most capable platform for the study area. Using Sentinel-2, we created spectral indices for the detection of algal blooms. We used these indices to measure algal blooms at 8 stations across the Big Cypress Reservation. We then created time series and seasonal decompositions of in situ water sample data and indices to visualize relationships between datasets, along with correlation matrices. Our correlations were not conclusive. However, we found that the spectral indices have the potential to detect algal blooms. Lastly, we evaluated Maxar WorldView-3 imagery and found that using data from sensors with higher spatial resolutions would improve results.

Remote sensing↗

Airborne lidar/radiometric measurements of cirrus cloud parameters and their application to LOWTRAN radiance evaluations

SRI has assembled an airborne lidar/radiometric instrumentation suite for mapping cirrus cloud distribution and analyzing cirrus cloud optical properties. Operation of upward viewing infrared radiometers from an airborne platform provides the optimum method of measuring high altitude cold cloud radiative properties with minimum interference from the thermal emission by the earth's surface and lower atmospheric components. Airborne installed sensors can also operate over large regional areas including water, urban, and mountain surfaces and above lower atmospheric convective clouds and haze layers. Currently available sensors installed on the SRI Queen Air aircraft are illustrated. Lidar and radiometric data records are processed for real time viewing on a color video screen. A cirrus cloud data example is presented as a black and white reproduction of a color display of data at the aircraft altitude of 12,000 ft, the 8 to 14 micron atmospheric radiation background was equivalent to a blackbody temperature of about -60 C and, therefore, the radiometer did not respond strongly to low density cirrus cloud concentrations detected by the lidar. Cloud blackbody temperatures (observed by radiometer) are shown plotted against midcloud temperatures (derived from lidar observed cloud heights and supporting temperature profiles) for data collected on 30 June and 28 July.

Uthe, Edward E.↗

An image recorded by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The airborne visible/infrared imaging spectrometer (AVIRIS) is described, and an example of a false-color image recorded by this device is provided. The AVIRIS is capable of sensing in 209 visible and near-infrared wavebands with an 11km swath and a 20m spatial resolution. Evaluation flights for AVIRIS were made at an altitude of approximately 20km x 10.2km of low-lying and relatively flat irrigated land near Yuba City and Sacramento, California. Raw data were converted from digital numbers to radiance and radiometrically corrected at the NASA Jet Propulsion Laboratory. Notch filtering in the frequency domain of the image was used to remove periodic noise. The illustration of both spatial and spectral properties on the false-color image are explained. AVIRIS is designed to be flown in an ER-2 aircraft and will serve as a test-bed sensor for the High-Resolution Imaging Spectrometer (HIRIS) planned for the Earth Observing System.

Curran, Paul J.↗

An atlas of monthly mean distributions of GEOSAT sea surface height, SSMI surface wind speed, AVHRR/2 sea surface temperature, and ECMWF surface wind components during 1988

Monthly mean global distributions for 1988 are presented with a common color scale and geographical map. Distributions are included for sea surface height variation estimated from GEOSAT; surface wind speed estimated from the Special Sensor Microwave Imager on the Defense Meteorological Satellite Program spacecraft; sea surface temperature estimated from the Advanced Very High Resolution Radiometer on NOAA spacecrafts; and the Cartesian components of the 10m height wind vector computed by the European Center for Medium Range Weather Forecasting. Charts of monthly mean value, sampling distribution, and standard deviation value are displayed. Annual mean distributions are displayed.

Halpern, D.↗

Decadal Changes in Global Ocean Annual Primary Production

The Sea-viewing Wide Field-of-View Sensor (SeaWiFS) has produced the first multi-year time series of global ocean chlorophyll observations since the demise of the Coastal Zone Color Scanner (CZCS) in 1986. Global observations from 1997-present from SeaWiFS combined with observations from 1979-1986 from the CZCS should in principle provide an opportunity to observe decadal changes in global ocean annual primary production, since chlorophyll is the primary driver for estimates of primary production. However, incompatibilities between algorithms have so far precluded quantitative analysis. We have developed and applied compatible processing methods for the CZCS, using modern advances in atmospheric correction and consistent bio-optical algorithms to advance the CZCS archive to comparable quality with SeaWiFS. We applied blending methodologies, where in situ data observations are incorporated into the CZCS and SeaWiFS data records, to provide improvement of the residuals. These re-analyzed, blended data records provide maximum compatibility and permit, for the first time, a quantitative analysis of the changes in global ocean primary production in the early-to-mid 1980's and the present, using synoptic satellite observations. An intercomparison of the global and regional primary production from these blended satellite observations is important to understand global climate change and the effects on ocean biota. Photosynthesis by chlorophyll-containing phytoplankton is responsible for biotic uptake of carbon in the oceans and potentially ultimately from the atmosphere. Global ocean annual primary decreased from the CZCS record to SeaWiFS, by nearly 6% from the early 1980s to the present. Annual primary production in the high latitudes was responsible for most of the decadal change. Conversely, primary production in the low latitudes generally increased, with the exception of the tropical Pacific. The differences and similarities of the two data records provide evidence of how the Earth's climate may be changing and how ocean biota respond. Furthermore, the results have implications for the ocean carbon cycle.

Gregg, Watson↗