Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “charging stations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Continuing life test of a xenon hollow cathode for a space plasma contactor

Implementation of a hollow cathode plasma contactor for charge control on the Space Station has required validation of long-life hollow cathodes. A test series of hollow cathodes and hollow cathode plasma contactors was initiated as part of the plasma contactor development program. An on-going wear-test of a hollow cathode has demonstrated cathode operation in excess of 10,000 hours with small changes in operating parameters. The discharge has experienced 10 shutdowns during the test, all of which were due to test facility failures or expellant replenishment. In all cases, the cathode was re-ignited at approximately 42 volts and resumed typical operation. This test represents the longest demonstrated stable operation of a high current (greater than 1 A) xenon hollow cathode reported to date.

Sarver-Verhey, Timothy R.↗

Extended test of a xenon hollow cathode for a space plasma contactor

Implementation of a hollow cathode plasma contactor for charge control on the Space Station has required validation of long-life hollow cathodes. A test series of hollow cathodes and hollow cathode plasma contactors was initiated as part of the plasma contactor development program. An on-going wear-test of a hollow cathode has demonstrated cathode operation in excess of 4700 hours with small changes in operating parameters. The discharge experienced 4 shutdowns during the test, all of which were due to test facility failures or expellant replenishment. In all cases, the cathode was reignited at approximately 42 volts and resumed typical operation. This test represents the longest demonstrated stable operation of a high current (greater than 1A) xenon hollow cathode reported to date.

Sarver-Verhey, Timothy R.↗

Integration issues of a plasma contactor Power Electronics Unit

A hollow cathode-based plasma contactor is baselined on International Space Station Alpha (ISSA) for spacecraft charge control. The plasma contactor system consists of a hollow cathode assembly (HCA), a power electronics unit (PEU), and an expellant management unit (EMU). The plasma contactor has recently been required to operate in a cyclic mode to conserve xenon expellant and extend system life. Originally, a DC cathode heater converter was baselined for a continuous operation mode because only a few ignitions of the hollow cathode were expected. However, for cyclic operation, a DC heater supply can potentially result in hollow cathode heater component failure due to the DC electrostatic field. This can prevent the heater from attaining the proper cathode tip temperature for reliable ignition of the hollow cathode. To mitigate this problem, an AC cathode heater supply was therefore designed, fabricated, and installed into a modified PEU. The PEU was tested using resistive loads and then integrated with an engineering model hollow cathode to demonstrate stable steady-state operation. Integration issues such as the effect of line and load impedance on the output of the AC cathode heater supply and the characterization of the temperature profile of the heater under AC excitation were investigated.

Pinero, Luis R.↗

STS-114: Discovery Crew Arrival

George Diller of NASA Public Affairs narrates the STS-114 Crew arrival at Kennedy Space Center aboard a Gulf Stream aircraft. They were greeted by Center Director Jim Kennedy. Commander Eileen Collins introduced each of her crew members and gave a brief description of their roles in the mission. Mission Specialist 3, Andrew Thomas will be the lead crew member on the inspection on flight day 2; he is the intravehicular (IV) crew member that will help and guide Mission Specialists Souichi Noguchi and Stephen Robinson during their spacewalks. Pilot James Kelly will be operating the shuttle systems in flying the Shuttle; he will be flying the space station robotic arm during the second extravehicular activity and he will be assisting Mission Specialist Wendy Lawrence during the other two extravehicular activities; he will be assisting on the rendezvous on flight day three, and landing of the shuttle. Commander Collins also mentioned Pilot Kelly's recent promotion to Colonel by the United States Air Force. Mission Specialist 1, Souichi Noguchi from JAXA (The Japanese Space Agency) will be flying on the flight deck for ascent; he will be doing three spacewalks on day 5, 7, and 9; He will be the photo/TV lead for the different types of cameras on board to document the flight and to send back the information to the ground for both technical and public affairs reasons. Mission Specialist 5, Charles Camada will be doing the inspection on flight day 2 with Mission Specialist Thomas and Pilot Kelly; he will be transferring the logistics off the shuttle and onto the space station and from the space station back to the shuttle; He will help set up eleven lap tops on board. Mission Specialist 4, Wendy Lawrence will lead the transfer of logistics to the space station; she is the space station arm operator during extravehicular activities 1 and 3; she will be carrying the 6,000 pounds of external storage platform from the shuttle payload bay over to the space station; she is also in charge of the shuttle storage. Mission Specialist 2, Stephen Robinson is the flight engineer of the shuttle; he will be doing spacewalks with Mission Specialist Noguchi; he will set up the 11 lap top computers on board. Each crew member gave a brief message to the press. Commander Eileen later gave her final message and the crew walked back to the Astronaut Corps.

Source record↗

International Space Station (ISS) Plasma Contactor Unit (PCU) Utilization Plan Assessment Update

The International Space Station (ISS) vehicle undergoes spacecraft charging as it interacts with Earth's ionosphere and magnetic field. The interaction can result in a large potential difference developing between the ISS metal chassis and the local ionosphere plasma environment. If an astronaut conducting extravehicular activities (EVA) is exposed to the potential difference, then a possible electrical shock hazard arises. The control of this hazard was addressed by a number of documents within the ISS Program (ISSP) including Catastrophic Safety Hazard for Astronauts on EVA (ISS-EVA-312-4A_revE). The safety hazard identified the risk for an astronaut to experience an electrical shock in the event an arc was generated on an extravehicular mobility unit (EMU) surface. A catastrophic safety hazard, by the ISS requirements, necessitates mitigation by a two-fault tolerant system of hazard controls. Traditionally, the plasma contactor units (PCUs) on the ISS have been used to limit the charging and serve as a "ground strap" between the ISS structure and the surrounding ionospheric plasma. In 2009, a previous NASA Engineering and Safety Center (NESC) team evaluated the PCU utilization plan (NESC Request #07-054-E) with the objective to assess whether leaving PCUs off during non-EVA time periods presented risk to the ISS through assembly completion. For this study, in situ measurements of ISS charging, covering the installation of three of the four photovoltaic arrays, and laboratory testing results provided key data to underpin the assessment. The conclusion stated, "there appears to be no significant risk of damage to critical equipment nor excessive ISS thermal coating damage as a result of eliminating PCU operations during non- EVA times." In 2013, the ISSP was presented with recommendations from Boeing Space Environments for the "Conditional" Marginalization of Plasma Hazard. These recommendations include a plan that would keep the PCUs off during EVAs when the space environment forecast input to the ISS charging model indicates floating potentials (FP) within specified limits. These recommendations were based on the persistence of conditions in the space environment due to the current low solar cycle and belief in the accuracy and completeness of the ISS charging model. Subsequently, a Noncompliance Report (NCR), ISS-NCR-232G, Lack of Two-fault Tolerance to EVA Crew Shock in the Low Earth Orbit Plasma Environment, was signed in September 2013 specifying new guidelines for the use of shock hazard controls based on a forecast of the space environment from ISS plasma measurements taken prior to the EVA [ISS-EVA-312-AC, 2012]. This NESC assessment re-evaluates EVA charging hazards through a process that is based on over 14 years of ISS operations, charging measurements, laboratory tests, EMU studies and modifications, and safety reports. The assessment seeks an objective review of the plasma charging hazards associated with EVA operations to determine if any of the present hazard controls can safely change the PCU utilization plan to allow more flexibility in ISS operations during EVA preparation and execution.

Hernandez-Pellerano, Amri↗

Cosmic Ray Energetics and Mass (CREAM)

The CREAM instrument was flown on a Long Duration Balloon in Antarctica in December 2004 and January 2005, achieving a flight duration record of nearly 42 days. It detected and recorded cosmic ray primary particles ranging in type from hydrogen to iron nuclei and in energy from 1 TeV to several hundred TeV. With the data collected we will have the world's best measurement of the energy spectra and mass composition of nuclei in the primary cosmic ray flux at these energies, close to the astrophysical knee . The instrument utilized a thin calorimeter, a transition radiation detector and a timing charge detector, which also provided time-of-flight information. The responsibilities of our group have been with the timing charge detector (TCD), and with the data acquisition electronics and ground station support equipment. The TCD utilized fast scintillators to measure the charge of the primary cosmic ray before any interactions could take place within the calorimeter. The data acquisition electronics handled the output of the various detectors, in a fashion fully integrated with the payload bus. A space-qualified flight computer controlled the acquisition, and was used for preliminary trigger information processing and decision making. Ground support equipment was used to monitor the health of the payload, acquire and archive the data transmitted to the ground, and to provide real-time control of the instrument in flight.

Coutu, Stephane↗

The Situational Awareness Sensor Suite for the ISS (SASSI): A Mission Concept to Investigate ISS Charging and Wake Effects

The complex interaction between the International Space Station (ISS) and the surrounding plasma environment often generates unpredictable environmental situations that affect operations. Examples of affected systems include extravehicular activity (EVA) safety, solar panel efficiency, and scientific instrument integrity. Models and heuristically‐derived best practices are well‐suited for routine operations, but when it comes to unusual or anomalous events or situations, especially those driven by space weather, there is no substitute for real‐time monitoring. Space environment data collected in real‐time (or near‐real time) can be used operationally for both real‐time alarms and data sources in assimilative models to predict environmental conditions important for operational planning. Fixed space weather instruments mounted to the ISS can be used for monitoring the ambient space environment, but knowing whether or not (or to what extent) the ISS affects the measurements themselves requires adequate space situational awareness (SSA) local to the ISS. This paper presents a mission concept to use a suite of plasma instruments mounted at the end of the ISS robotic arm to systematically explore the interaction between the Space Station structure and its surrounding environment. The Situational Awareness Sensor Suite for the ISS (SASSI) would be deployed and operated on the ISS Express Logistics Carrier (ELC) for long‐term "survey mode" observations and the Space Station Remote Manipulator System (SSRMS) for short‐term "campaign mode" observations. Specific areas of investigation include: 1) ISS frame and surface charging during perturbations of the local ISS space environment, 2) calibration of the ISS Floating Point Measurement Unit (FPMU), 3) long baseline measurements of ambient ionospheric electric potential structures, 4) electromotive force-induced currents within large structures moving through a magnetized plasma, and 5) wake‐induced ion waves in both electrostatic (i.e. particles) and electromagnetic modes. SASSI will advance the understanding of plasma‐boundary interaction phenomena, demonstrate a suite a sensors acting in concert to provide effective SSA, and validate and/or calibrate existing ISS space environment instruments and models.

Krause, L. Habash↗

Comparison of On-orbit and Ground Based Hollow Cathode Operation

The Plasma Contactor Units (PCUs) were developed at NASA Glenn Research Center (GRC) and Boeing for charge control on board the International Space Station (ISS). Since the first ignition of a PCU on 10/16/2000 over 3,900 hours of operation have been demonstrated on a single unit. In order to guarantee that the PCUs hollow cathode assemblies (HCAs), which emit the electrons used for charge control, would satisfy the life requirement of 18,000 hours, a ground based hollow cathode life test program was initiated at GRC. The life test program aimed at 27,000 hours of operation on a single unit to demonstrate the industry standard 1.5 times operational life requirement. As of this printing, over 18,000 hours of operation have been accumulated on a single hollow cathode. By comparing the data received from the on-orbit HCAs to the data obtained for the life test cathodes, a comparison may be drawn to determine if the on-orbit HCAs are operating normally, with a final goal of predicting lifetime. Based on the data taken thus far, it can be concluded that the on-orbit HCAs are operating within their design specifications.

Patterson, Michael↗

Hydroscanner: Instrumentation for Water Ingress Imaging in Photovoltaic Module Packaging Materials

A new iteration of the Hydroscanner prototype was designed and built during the execution of the contract. Compared to the previous designs, the communication port was changed from ethernet to USB C, since it provides a more seamless integration as a peripheral unit. An additional advantage is that one single port can be used for both communication and power up of the infrared camera. Although the power requirements are higher than the typical amount provided by a laptop computer, the camera can be run as a peripheral from a docking station when connected to a thunderbolt charging port. The software interface was modified to accommodate two imaging modes, an 8-bit and 14-bit image display. The 8-bit images use a custom colorization scheme that divides all pixels in the image into bins of equal width, such that images containing a wide range of brightness display the intermediate pixel intensities in greyscale values that enhance the contrast. The 14-bit images provide the direct readout from the focal plane array of the camera and can be saved as a text file for later processing in other software packages (MATLAB, Python).

47 OTHER INSTRUMENTATION↗

Tracking system analytic calibration activities for the Mariner Mars 1971 mission

This report describes the functions of the Tracking System Analytic Calibration activity for Mariner Mars 1971 (MM'71), its objectives for this and future missions, and the support provided to the MM'71 Navigation Team during operations. The support functions encompass calibration of tracking data by estimating physical parameters whose uncertainties represent limitations to navigational accuracy, and detailed analysis of the tracking data to uncover and resolve any anomalies. Separate articles treat the activities and results of producing calibrations for the various error sources: Deep Space Station Locations, timing and polar motion, charged particles, and the troposphere. Two other articles are also included dis- - cussing the effects of the media error sources on orbit determination and the merits of the smoothing technique used for DRIVID.

Facilities↗

The tracking system analytic calibration activity for Mariner Mars 1971: Its function and scope

The functions of the Tracking System Analytic Calibration activity for Mariner Mars 1971 (MM'71), its objectives for this and future missions, and the support provided to the MM'71 Navigation Team during operations are described. Support functions encompass calibration of tracking data by estimating physical parameters whose uncertainties represent limitations to navigational accuracy, and detailed analysis of the tracking data to uncover and resolve any anomalies. Separate articles treat the activities and results of producing calibrations for the various error sources: Deep Space Station Locations, timing and polar motion, charged particles, and the troposphere. Two other articles are also included discussing the effects of the media error sources on orbit determination and the merits of the smoothing technique used for DRIVID.

Madrid, G. A.↗

Radiation Protection Effectiveness of Polymeric Based Shielding Materials at Low Earth Orbit

Correlations of limited ionizing radiation measurements onboard the Space Transportation System (STS; shuttle) and the International Space Station (ISS) with numerical simulations of charged particle transport through spacecraft structure have indicated that usage of hydrogen rich polymeric materials improves the radiation shielding performance of space structures as compared to the traditionally used aluminum alloys. We discuss herein the radiation shielding correlations between measurements on board STS-81 (Atlantis, 1997) using four polyethylene (PE) spheres of varying radii, and STS-89 (Endeavour, 1998) using aluminum alloy spheres; with numerical simulations of charged particle transport using the Langley Research Center (LaRC)-developed High charge (Z) and Energy TRaNsport (HZETRN) algorithm. In the simulations, the Galactic Cosmic Ray (GCR) component of the ionizing radiation environment at Low Earth Orbit (LEO) covering ions in the 1< or equals Z< or equals 28 range is represented by O'Neill's (2004) model. To compute the transmission coefficient for GCR ions at LEO, O'Neill's model is coupled with the angular dependent LaRC cutoff model. The trapped protons/electrons component of LEO environment is represented by a LaRC-developed time dependent procedure which couples the AP8min/AP8max, Deep River Neutron Monitor (DRNM) and F10.7 solar radio frequency measurements. The albedo neutron environment resulting from interaction of GCR ions with upper atmosphere is modeled through extrapolation of the Atmospheric Ionizing Radiation (AIR) measurements. With the validity of numerical simulations through correlation with PE and aluminum spheres measurements established, we further present results from the expansion of the simulations through the selection of high hydrogen content commercially available polymeric constituents such as PE foam core and Spectra fiber(Registered TradeMark) composite face sheet to assess their radiation shield properties as compared to generic PE.

Badavi, Francis F.↗

Characteristics of Extreme Auroral Charging Events

The highest level spacecraft charging observed in low Earth orbit (LEO) occurs when spacecraft are exposed to energetic auroral electrons. Since auroral charging has been identified as a mechanism responsible for on-orbit anomalies and even possible satellite failures it is important to consider extreme auroral charging events as design and test environments for spacecraft to be used in high inclination LEO orbits. This paper will report on studies of extreme auroral charging events using data from the SSJ/4 and SSJ/5 precipitating electron and ion sensors on the Defense Meteorology Satellite Program (DMSP) satellites. Early studies of DMSP charging to negative potentials ≥100 V focused on statistics of the electron environment responsible for charging. Later statistical studies of auroral charging have generally focused on solar cycle dependence of charging behavior and magnitude of the maximum potential and duration of the charging events. We extend these studies to focus on more detailed investigations of extreme charging event characteristics that are required to evaluate potential threats to spacecraft systems. A collection of example auroral charging events is assembled from the DMSP data set using the criteria that "extreme auroral charging" is defined as periods with spacecraft negative potentials ≥400 V. Specific characteristics to be treated include (but are not limited to) maximum and mean potentials, time history of spacecraft potentials through the events, total charging duration and the time potentials exceed voltage thresholds, frame charging/discharging rates, and information on geographic and geomagnetic latitudes at which the events are observed. Finally, we will comment on the implications of these studies for potential auroral charging risks to the International Space Station.

Minow, Joseph I.↗

Direct Measurement of the Spectral Structure of Cosmic-Ray Electrons+Positrons in the Tev Region With Calet on the International Space Station

Detailed measurements of the spectral structure of cosmic-ray electrons and positrons from 10.6 GeV to 7.5 TeV are presented from over 7 years of observations with the CALorimetric Electron Telescope (CALET) on the International Space Station. The instrument, consisting of a charge detector, an imaging calorimeter, and a total absorption calorimeter with a total depth of 30 radiation lengths at normal incidence and a fine shower imaging capability, is optimized to measure the all-electron spectrum well into the TeV region. Because of the excellent energy resolution (a few percent above 10 GeV) and the outstanding e/p separation (10 5 ), CALET provides optimal performance for a detailed search of structures in the energy spectrum. The analysis uses data up to the end of 2022, and the statistics of observed electron candidates has increased more than 3 times since the last publication in 2018. By adopting an updated boosted decision tree analysis, a sufficient proton rejection power up to 7.5 TeV is achieved, with a residual proton contamination less than 10%. The observed energy spectrum becomes gradually harder in the lower energy region from around 30 GeV, consistently with AMS-02, but from 300 to 600 GeV it is considerably softer than the spectra measured by DAMPE and Fermi-LAT. At high energies, the spectrum presents a sharp break around 1 TeV, with a spectral index change from −3.15 to −3.91, and a broken power law fitting the data in the energy range from 30 GeV to 4.8 TeV better than a single power law with 6.9 sigma significance, which is compatible with the DAMPE results. The break is consistent with the expected effects of radiation loss during the propagation from distant sources (except the highest energy bin). We have fitted the spectrum with a model consistent with the positron flux measured by AMS-02 below 1 TeV and interpreted the electron+positron spectrum with possible contributions from pulsars and nearby sources. Above 4.8 TeV, a possible contribution from known nearby supernova remnants, including Vela, is addressed by an event-by-event analysis providing a higher proton-rejection power than a purely statistical analysis.

O. Adriani↗

Multistage Electrophoretic Separators

A multistage electrophoresis apparatus has been invented for use in the separation of cells, protein molecules, and other particles and solutes in concentrated aqueous solutions and suspensions. The design exploits free electrophoresis but overcomes the deficiencies of prior free-electrophoretic separators by incorporating a combination of published advances in mathematical modeling of convection, sedimentation, electro-osmotic flow, and the sedimentation and aggregation of droplets. In comparison with other electrophoretic separators, these apparatuses are easier to use and are better suited to separation in relatively large quantities characterized in the art as preparative (in contradistinction to smaller quantities characterized in the art as analytical). In a multistage electrophoretic separator according to the invention, an applied vertical steady electric field draws the electrically charged particles of interest from within a cuvette to within a collection cavity that has been moved into position of the cuvette. There are multiple collection cavities arranged in a circle; each is aligned with the cuvette for a prescribed short time. The multistage, short-migration-path character of the invention solves, possibly for the first time, the fluid-instability problems associated with free electrophoresis. The figure shows a prototype multistage electrophoretic separator that includes four sample stations and five collection stages per sample. At each sample station, an aqueous solution or suspension containing charged species to be separated is loaded into a cuvette, which is machined into a top plate. The apparatus includes a lower plate, into which 20 collection cavities have been milled. Each cavity is filled with an electrophoresis buffer solution. For the collection of an electrophoretic fraction, the lower plate is rotated to move a designated collection cavity into alignment with the opening of the cuvette. An electric field is then applied between a non-gassing electrode in the collection cavity and an electrolyte compartment, which is separated from the cuvette by a semipermeable membrane. The electrolyte is refreshed by circulation by use of a peristaltic pump. In subsequent steps, the lower plate is rotated to collect other electrophoretic fractions. Later, the collected fractions are removed from the collection cavities through ports that have threaded plugs. The base of the apparatus contains power supplies and a computer interface. The design includes provisions for monitoring and feedback control of cavity position, electric field, and temperature. The operation of the apparatus can easily be automated, as demonstrated by use of software that has already been written for this purpose.

Thomas, Nathan↗

Development of a DC Distribution Testbed for High-Power EV Charging

This paper explores the design and implementation of a power hardware-in-the-loop (P-HIL) setup for DC distribution infrastructure integrated with high-power charging (HPC) of electric vehicles (EVs), DC loads, and sources. The utilization of DC distribution holds significant potential for enhancing the operation of a HPC station architecture. However, there are challenges establishing a DC charging hub including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and lack of common system level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products to evaluate different use cases at rated power and voltage levels. The developed P-HIL setup features a dedicated DC charging hub, DC-coupled chargers, DC loads/sources, DC protection, and a communication architecture. The integrated P-HIL system provides a versatile testing environment to address technology and interoperability gaps and implements a smart energy management system (SEMS). This platform enables comprehensive and robust testing of COTS devices, charger prototypes, SEMS controllers and protection schemes, which together will accelerate transition to EVs at scale. The setup is tested for various use-cases at full-scale, integrating 950 V DC bus voltage, 660 kW grid-tied inverter, 150 kW COTS charger, and 100 kW energy storage system within an open-source SEMS platform.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Extrapolation of electrical breakdown currents from the laboratory to Space Station

Recent experiments conducted in a plasma chamber at NASA/MSFC on anodized aluminum coatings representative of Space Station Freedom design show that if the aluminum used as a thermal control coating is biased more than 80 V negative with respect to the plasma, the anodization will experience dielectric breakdown. As the thin anodization layer creates a capacitive charge buildup, large currents are observed during the arc. How plasma generation at the arc site can support large currents and discharge the surface charge layer is investigated. The importance for Space Station Freedom is that currents similar to those observed in the laboratory can be observed on orbit.

Vaughn, Jason A.↗

Twenty Years of Radiation Measurements in Low-Earth Orbit - What Have We Learned Space Radiation Environment?

The advent of the Space Shuttle program has made possible space radiation environment measurements spanning a wide range of altitudes and orbital inclinations over multiple solar cycles. These measurements range from routine integral dose measurements with thermoluminescent dosimeters to particle energy spectra measurements made with a charged particle telescope. This paper will review the new understanding about the space radiation environment gained from this diverse data set. Major findings from these measurements include: estimations of the westward drift rate of the South Atlantic Anomaly (SAA) of 0.28-0.49/y; evidence for a northward component to the SAA drift of 0.08-0.12/y; observation of the formation and decay of the pseudo-stable additional radiation belt following the Mar 1991 SPE and geomagnetic storm with an estimated decay e-folding time of 9-10 months; observation of a local geomagnetic east-west trapped proton exposure anisotropy with an estimated magnitude of 1.6-3.3; demonstration that the trapped proton exposure in low-Earth orbit (LEO) can be reasonably modeled as a power law function of atmospheric density in the SAA region, with best correlations obtained when the exospheric temperature saturates at 938-975 K; the actual solar cycle modulation of trapped proton exposure in LEO is less than predicted by the AP8 model; and the testing and validation of GCR flux models, radiation transport codes, and dynamic geomagnetic cutoff models. Long-term, time-resolved proportional counter measurements made aboard the Mir during the same period provides further demonstration of the solar cycle modulation of the trapped protons at low altitudes - the observed modulation is also well described as power law function of atmospheric density. These data and findings have helped to improve the overall accuracy of pre-mission crew exposure projections using various semi-empirical space environment models, radiation transport codes, and spacecraft radiation shielding models. During the rise phase of solar cycle 22 (1987-1991), the RMS error between preflight exposure projections and measured crew exposure was 73%. For the rise phase of cycle 23 (1997-2001), the preflight exposure projection RMS error has decreased to 23%. The launch and assembly of the Space Station has begun a new era of long-term LEO space environment monitoring. The radiation environment at the Space Station will be monitored with three external charged particle telescopes oriented in the velocity vector, anti-velocity vector, and zenith directions. Data from the telescopes will provide charge, mass, energy, and arrival direction for incident particles with energy to mass ratios of 13- 450 MeV/amu and Z of 1-24. The external environment data will be complimented by measurements from a portable charged particle telescope and proportional counter located inside the vehicle.

Golightly, Michael J.↗