Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Specimen Holder For Flammability Tests

Fixture holds sheet specimens for flammability tests. Frame and clamps designed to minimize local overstress on specimen. Heat capacity of fixture low, interfering less with interpretation of results of test by drawing less heat away from specimen. Accepts films, fabrics, foams, and other sheets, rigid or flexible. Specimens thin or thick, or of variable thickness. Bent to accommodate curved rigid specimens. Also used for such other tests as particle-impact tests.

Rucker, Michelle A.↗

NASA and Advanced Air Mobility (AAM) National Campaign (NC) Tech Talk: Integrated Data Product

NASA Advanced Air Mobility (AAM) National Campaign has hosted multiple flight tests in a effort to promote public confidence and accelerate the realization of emerging aviation markets for passenger and cargo transportation in urban, suburban, rural, and regional environments. The goals and objectives for each flight test are intended to assess the performance of the vehicle’s capacity to operate safely, efficiently, and sustainably in urban areas. The Airspace Test and Infrastructure (ATI) team processes the flight data to evaluate the effectiveness of air vehicle and airspace management integration, while its analysis capabilities support the assessment of the efficacy of proposed vehicles and ground systems required to enable the vehicles’ operations. The ATI data services team creates many products from the data, first by transforming and merging the data into a single Integrated Data Product (IDP). This aligns data from many sources by time, so that, for example, the winds that impacted a flight can be aligned with its ground track and speed. A detailed IDP enables many types of statistical computation and visualizations that help researchers understand what transpired during the flight and how it can be explained. This Tech Talk will give an overview of the IDP process, including examples of the resulting products created by the data services team. It will also share an application that will allow participants to perform their own data analysis.

National Campaign, Advanced Air Mobility, Integrat↗

Lithium-Ion Battery Testing Capable of Simulating “Ultralow” Lunar Temperatures

The first-ever lithium-ion battery cycler capable of testing the coin and pouch cells under ultralow (≤40 °C) temperatures down to -175 °C to simulate extreme climates found in the lunar and space missions, high-altitude air vehicles, polar regions of Earth, and military expeditionary missions is enthusiastically reported. The extremely cold temperatures are achieved through a tailored extreme low-temperature system (ELTS) with liquid nitrogen flow and the ability to reach temperatures between -175 and 25 °C, using 1 kΩ and 1 MΩ resistors at varying currents of 1–4 mA and 1–4 μA, respectively, is validated. Employing the ELTS, Li 4 Ti 5 O 12 (LTO)||Li cells with 1 m lithium bis(fluorosulfonyl)imide in cyclopentyl methyl ether as an electrolyte developed in this research group are charged and discharged at room temperature (cycling rate C/5), -20 (C/10), -40 (C/40), and -60 °C (C/50), which exhibited discharge capacities of 159.04, 119.12, 101.79, and 33.06 mAh g -1 , respectively. Moreover, the LTO||Li cell produced a reversible capacity of 7.12 mAh g -1 tested at -100 °C for the first time.

25 ENERGY STORAGE↗

Low pCO2 Air-Polarized CO2 Concentrator Development

Life Systems completed a Ground-based Space Station Experiment Development Study Program which verifies through testing the performance and applicability of the electrochemical Air-Polarized Carbon Dioxide Concentrator (APC) process technology for space missions requiring low (i.e., less than 3 mm Hg) CO2 partial pressure (pCO2) in the cabin atmosphere. Required test hardware was developed and testing was accomplished at an approximate one-person capacity CO2 removal level. Initially, two five-cell electrochemical modules using flight-like 0.5 sq ft cell hardware were tested individually, following by their testing at the integrated APC system level. Testing verified previously projected performance and established a database for sizing of APC systems. A four person capacity APC system was sized and compared with four candidate CO2 removal systems. At its weight of 252 lb, a volume of 7 cu ft and a power consumption of 566 W while operating at 2.2 mm Hg pCO2, the APC was surpassed only by an Electrochemical Depolarized CO2 Concentrator (EDC) (operating with H2), when compared on a total equivalent basis.

Schubert, Franz H.↗

Non-gassing nickel-cadmium battery electrodes and cells: Testing of 25 Ah cells

The testing of 30 practical size, experimental 25 ampere hour cells constructed as part of an earlier negative limited cell development program is discussed. The test results showed that the negative limited cell is a possible means of developing a long-lived secondary cell. The cells were tested for 500 cycles using an accelerated regime approximating a 90-minute orbit period. Three groups of ten cells were tested at 0,25, and 40 C. The cycle data showed that the negative limited cells had higher degradation rates at the higher operating temperatures. At the conclusion of 500 cycles, the three groups had average capacities of 16.83, 12.74, and 5.71 ampere hours for testing at 0, 25, 40 C, respectively. The conditioning capacities of these cells was in the 25 ampere hours range. The internal cell pressures of the three groups was also temperature dependent and was, in general, in the 2 psig range during the course of the test program. No periodic variation of the internal pressure with the state-of-charge was observed except with some cells tested at 40 C.

Luksha, E.↗

Detecting gear tooth fracture in a high contact ratio face gear mesh

This paper summarized the results of a study in which three different vibration diagnostic methods were used to detect gear tooth fracture in a high contact ratio face gear mesh. The NASA spiral bevel gear fatigue test rig was used to produce unseeded fault, natural failures of four face gear specimens. During the fatigue tests, which were run to determine load capacity and primary failure mechanisms for face gears, vibration signals were monitored and recorded for gear diagnostic purposes. Gear tooth bending fatigue and surface pitting were the primary failure modes found in the tests. The damage ranged from partial tooth fracture on a single tooth in one test to heavy wear, severe pitting, and complete tooth fracture of several teeth on another test. Three gear fault detection techniques, FM4, NA4*, and NB4, were applied to the experimental data. These methods use the signal average in both the time and frequency domain. Method NA4* was able to conclusively detect the gear tooth fractures in three out of the four fatigue tests, along with gear tooth surface pitting and heavy wear. For multiple tooth fractures, all of the methods gave a clear indication of the damage. It was also found that due to the high contact ratio of the face gear mesh, single tooth fractures did not significantly affect the vibration signal, making this type of failure difficult to detect.

Zakrajsek, James J.↗

Lithium D-cell study

The purpose of this contract is to evaluate parametrically the effects of various factors including the electrolyte type, electrolyte concentration, depolarizer type, and cell configuration on lithium cell electrical performance and safety. This effort shall allow for the selection and optimization of cell design for future NASA applications while maintaining close ties with WGL's continuous improvements in manufacturing processes and lithium cell design. Taguchi experimental design techniques are employed in this task, and allow for a maximum amount of information to be obtained while requiring significantly less cells than if a full factorial design were employed. Acceptance testing for this task is modeled after the NASA Document EP5-83-025, Revision C, for cell weights, OCV's and load voltages. The performance attributes that are studied in this effort are fresh capacity and start-up characteristics evaluated at two rates and two temperatures, shelf-life characteristics including start-up and capacity retention, and iterative microcalorimetry measurements. Abuse testing includes forced over discharge at two rates with and without diode protection, temperature tolerance testing, and shorting tests at three rates with the measurement of heat generated during shorting conditions.

Size, P.↗

A Dendrite-Resistant Sodium/Porous-Carbon Anode for Solid-State Batteries – Strategies and Challenges for Low-Pressure Operation

Sodium solid-state batteries (Na-SSB) have gained interest recently due to the abundance of Na over Li, but they still tend to fail due to dendrites under practical current densities and cycling capacities. To overcome this, Na-SSBs are frequently tested with impractically high applied pressure. In this work, a porous carbon interfacial layer is utilized in conjunction with Na-ß”-Al2O3 solid electrolytes to enable Na-cycling at milder cell pressures. This sodium/porous carbon layer enables improved solid-state Na cycling in symmetric cells, up to a current density of 10 mA cm-2 at 25 °C. Cycling up to 1 mAh cm-2 is challenging with low pressure, but 1 mAh cm-2 capacity can be reliably cycled at 1 mA cm-2 at an elevated temperature of 60 °C in symmetric cells. Finally, the evolution of the interface and sodium/carbon anode is evaluated with cryogenic ion-milling and cross-sectional imaging revealing that, depending on testing temperature, pressure, current density, and capacity, void formation, Na-extraction from porous carbon, delamination of the porous carbon matrix, or a combination of these occurs at the interface between Na-metal and BASE. Despite this, excellent dendrite resistance is achieved, and a full-cell design utilizing a Na-transition metal oxide cathode is still able to achieve an areal capacity of ~ 2.7 mAh cm-2 at 0.125 mA cm-2. This work demonstrates an alternative pathway toward a Na-metal anode for Na-SSBs without the requirement of excessive stack pressure.

low-cost↗

Ultra-high-voltage Ni-rich layered cathodes in practical Li metal batteries enabled by a sulfonamide-based electrolyte

By increasing the charging voltage, a cell specific energy of >400 Wh kg-1 is in principle achievable with LiNi0.8Mn0.1Co0.1O2 in lithium-metal batteries (LMBs). However, stable cycling of high-nickel cathodes at ultra-high voltages is extremely challenging. Here we report that a rationally designed sulfonamide-based electrolyte enables stable cycling of commercial LiNi0.8Co0.1Mn0.1O2 with a cut-off voltage up to 4.7 V in LMBs. In contrast to commercial carbonate electrolytes, the electrolyte not only suppresses side reactions, intergranular cracking, transition-metal dissolution, and impedance growth on the cathode side, but also enables highly reversible Li metal stripping and plating leading to compact morphology and low pulverization. Our LMB delivers a specific capacity >230 mAh g-1 and an average Coulombic efficiency >99.65% over 100 cycles. Even under harsh testing conditions, the 4.7 V LMB can retain >88% capacity for 90 cycles, demonstrating significant advances in practical LMBs.

36 MATERIALS SCIENCE↗

Performance characteristics of an electric vehicle lead-acid battery pack at elevated temperatures

Discharge testing data electric car battery pack over initial electrolyte temperature variations between 27 and 55 C are presented. The tests were conducted under laboratory conditions and then compared to detailed electric vehicle simulation models. Battery discharge capacity increased with temperature for constant current discharges, and battery energy capacity increased with temperature for constant power discharges. Dynamometer tests of the electric test vehicle showed an increase in range of 25% for the higher electrolyte temperature.

Chapman, P.↗

Durability Study of a High-Pressure Common Rail Fuel Injection System Using Lubricity Additive-Dosed Gasoline-Like Fuel—Improved Endurance with Upgraded Hardware

Gasoline compression ignition (GCI) is a promising combustion technology that can help the commercial transportation sector achieve operational flexibility and meet upcoming criteria pollutant regulations. However, high-pressure fuel injection systems (>1000 bar) are needed to enable GCI and fully realize its benefits compared to conventional diesel combustion. This work is a continuation of previous durability studies that identified three key technical risks after running gasoline-like fuel through a heavy-duty, common rail injection system: (i) cavitation damage to the inlet check valve of the high-pressure pump, (ii) loss of injector fueling capacity, (iii) cavitation erosion of the injector nozzle holes. Upgraded hardware solutions were tested on a consistent 400- to 800-hour NATO durability cycle with the same gasoline-like fuel as previous studies. The upgraded pump showed no signs of abnormal wear or cavitation damage to the inlet check valve. In contrast to previous studies, there were no signs of pump performance degradation observed after 400 hours of testing. Material selection and design upgrades were also made to the injector which, only showed a 6.5% loss in fueling capacity after 800 hours of durability testing compared to 49.3% previously. Finally, geometric nozzle hole features such as higher inlet radius of curvature and higher K-factor were found to correlate with reduced cavitation erosion. However, mitigation of eccentric radial needle motion (i.e., wobble) is likely needed to further suppress cavitation. In general, the results from this study indicate there are viable hardware-based solutions for improving the endurance of high-pressure systems when running with gasoline-like fuel.

33 ADVANCED PROPULSION SYSTEMS↗

The Use of Dynamic Visual Acuity as a Functional Test of Gaze Stabilization Following Space Flight

After prolonged exposure to a given gravitational environment the transition to another is accompanied by adaptations in the sensorimotor subsystems, including the vestibular system. Variation in the adaptation time course of these subsystems, and the functional redundancies that exist between them make it difficult to accurately assess the functional capacity and physical limitations of astro/cosmonauts using tests on individual subsystems. While isolated tests of subsystem performance may be the only means to address where interventions are required, direct measures of performance may be more suitable for assessing the operational consequences of incomplete adaptation to changes in the gravitational environment. A test of dynamic visual acuity (DVA) is currently being used in the JSC Neurosciences Laboratory as part of a series of measures to assess the efficacy of a countermeasure to mitigate postflight locomotor dysfunction. In the current protocol, subjects visual acuity is determined using Landolt ring optotypes presented sequentially on a computer display. Visual acuity assessments are made both while standing and while walking at 1.8 m/s on a motorized treadmill. The use of a psychophysical threshold detection algorithm reduces the required number of optotype presentations and the results can be presented immediately after the test. The difference between the walking and standing acuity measures provides a metric of the change in the subject s ability to maintain gaze fixation on the visual target while walking. This functional consequence is observable regardless of the underlying subsystem most responsible for the change. Data from 15 cosmo/astronauts have been collected following long-duration (approx. 6 months) stays in space using a visual target viewing distance of 4.0 meters. An investigation of the group mean shows a change in DVA soon after the flight that asymptotes back to baseline approximately one week following their return to earth. The performance of some subjects nicely parallels the stereotypical recovery curve observed in the group mean data. Others show dramatic changes in DVA from one test day to another. These changes may be indicative of a re-adaptation process that is not characterized by a steady improvement with the passage of time, but is instead a dynamic search for appropriate coordinative strategy to achieve the desired gaze stabilization goal. Ground-based data have been collected in our lab using DVA with one of the goals being to improve the DVA test itself. In one of these studies, the DVA test was repeated using a visual target viewing distance of 0.5 meters. While walking, the relative contributions of the otoliths and semi-circular canals that are required to stabilize gaze are affected by visual target viewing distance. It may be possible to exploit this using the current treadmill DVA test to differentially assess changes in these vestibular subsystems. The postflight DVA evaluations currently used have been augmented to include the near target version of the test. Preliminary results from these assessments, as well as the results from the ground-based tests will also be reported. DVA provides a direct measure of a subject's ability to see clearly in the presence of self-motion. The use of the current tests for providing a functionally relevant metric is evident. However, it is possible to expand the scope of DVA testing to include scenarios other than walking. A facility for measuring DVA in the presence of passive movements is being created. Using a mechanized platform to provide the perturbation, it should be possible to simulate aircraft and automobile vibration profiles. Used in conjunction with the far and near visual displays this facility should be able to assess a subject s ability to clearly see distant objects as well as those that appear on the dashboard or instrument control panel during functionally relevant situations.

Peters, B. T.↗

Performance and Safety Tests on Samsung 18650 Li-ion Cells: Two Cell Designs

In order to meet the applications for space shuttle in future, two types of Samsung cells, with capacity 1800 mAh and 2000 mAh, have been investigated. The studies focused on: (1) Performance tests: completed 250 cycles at various combinations of charge/discharge C rates and discharge capacity measurements at various temperatures; and (2) Safety tests: overcharge and overdischarge, heat abuse, short circuit, internal and external short, and vibration, vacuum, and drop tests

Deng, Yi↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Long-term cyclability of Li 4 Ti 5 O 12 /LiMn 2 O 4 cells using carbonate-based electrolytes for behind-the-meter storage applications

Li 4 Ti 5 O 12 /LiMn 2 O 4 (LTO/LMO) chemistry was evaluated as a potential candidate for behind-the-meter storage (BTMS) applications. Its long-term cycle performance at 45 °C was tested using ethylene carbonate (EC) and propylene carbonate (PC) solvent electrolytes. Over 1000 cycles, LTO/LMO cells exhibited ~80% capacity retention and Coulombic efficiency higher than 99.96%. Electrochemical test results showed the major degradation mode of LTO/LMO cells arises from continuous electrolyte decomposition at the LTO anode and loss of Li inventory. EC and PC electrolytes created distinct surface layers, where the EC reduction products were more effective in passivating the LTO electrode surface. Dissolution and migration of Mn from the cathode was probed as Mn 2+ species distributed throughout the surface layer at the anode. By utilizing a prelithiated LTO electrode, the LTO/LMO cell performance was significantly enhanced with EC electrolyte. On the other hand, PC electrolyte resulted in accelerated electrolyte decomposition at the lithiated LTO surface due to the lack of surface passivation. Thus, mitigating parasitic reactions at the LTO electrode is the key to developing successful LTO/LMO cells.

25 ENERGY STORAGE↗

Degradation and Modeling of Large-Format Commercial Lithium-Ion Cells as a Function of Chemistry, Design, and Aging Conditions

Demand for large-format (>10 Ah) lithium-ion batteries has increased substantially in recent years, due to the growth of both electric vehicle and stationary energy storage markets. The economics of these applications is sensitive to the lifetime of the batteries, and end-of-life can either be due to energy or power limitations. Despite this, there is little information from cell manufacturers on the sensitivity of cell degradation to environmental conditions or battery use. This work reports accelerated aging test data from four commercial large-format lithium-ion batteries from three manufacturers, with varying design (thickness, casings, ...), chemistry (lithium-iron-phosphate (LFP) or lithium-nickel-manganese-cobalt-oxide positive electrodes (NMC), with graphite (Gr) negative electrodes), and capacity (50 to 250 Amp hours). The tested LFP|Gr cell is found to be relatively insensitive to cycling conditions like temperature or voltage window, while NMC|Gr cells have varying sensitivity. Degradation trends are further investigated by training predictive models: simple polynomial trend lines, a semi-empirical reduced-order model, and an empirical reduced-order model identified using machine-learning based on symbolic regression. Calendar and cycle life are simulated over a variety of conditions to directly compare the various batteries. Cell size and thickness are found to substantially impact sensitivity to temperature during cycle aging, while electrode chemistry impacts depth-of-discharge sensitivity. Real-world battery lifetime is evaluated by simulating residential energy storage and commercial frequency containment reserve systems in several U.S. climate regions. Predicted lifetime across cell types varies from 7 years to 20+ years, though all cells are predicted to have at least 10 year life in certain conditions.

battery lifetime↗

Ultrasonic nondestructive diagnosis of lithium-ion batteries with multiple frequencies

Accurately estimating the state of charge (SoC) in battery management systems (BMSs) requires the measurement of numerous parameters and advanced algorithms. This work studies multifrequency ultrasonic waves to estimate the SoC of Li-ion batteries by sensing the material changes during charge/discharge. A pouch-type LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) graphite battery cell is designed and fabricated with a capacity of 2.4 Ah. Different ultrasonic testing setups are explored to determine the optimal testing parameters for the battery. An ultrasonic monitoring system is developed to monitor the battery during charge/discharge at 750 kHz, 1 MHz, and 1.5 MHz. Signal processing algorithms are proposed for extracting three ultrasonic features—amplitude, wave velocity, and attenuation. In a three-cycle test, the amplitude histories do not show clear correlations with the SoC. The wave velocities of all three frequencies have an approximately linear relationship with the SoC, which can be used for SoC estimation. Hysteresis behavior is observed for the wave velocity in terms of a larger slope in the discharge process and velocity drop after a close charge/discharge cycle. The wave attenuation is able to capture the material phase transitions during charge/discharge.

25 ENERGY STORAGE↗

Application of Intelligent Load Control to Manage Building Loads to Support Rapid Growth of Distributed Renewable Generation

Electricity utilities are faced with the mounting challenge of providing a stable supply of power to meet the growing demand while also integrating rapid growth in distributed variable renewable generation. Traditional means of balancing short- and long-term supply and demand imbalance will be expensive. Alternative approaches of using flexible loads in buildings are needed to mitigate the imbalance at a lower cost. This paper shows how the intelligent load control (ILC) process can be used to manage loads in buildings by dynamically prioritizing loads for curtailment using both quantitative and qualitative criteria. The ILC process can be deployed on low-cost computing platforms without the need for any additional sensing. ILC was first validated in a simulation environment to provide two grid service use cases: (1) managing monthly peak electricity demand and (2) managing buildings’ electricity consumption during a capacity bidding event. After being successfully tested in a simulation environment, ILC was deployed on real buildings to manage electricity consumption to provide two different use cases under different outdoor operating conditions. Both the simulation tests and the real building experiments were deployed using VOLTTRON™, a distributed sensing and control platform. The results from the tests and experiments showed that ILC was able to manage the controllable loads (heat pumps) in the building to maintain the electricity consumption at the desired level without a significant impact on occupant comfort. Overall, the results demonstrate that the ILC allows coordination of the controllable loads and provides a more intelligent means of load management than the traditional duty-cycling approach.

Kim, Woohyun↗