Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Multiple Waveband Temperature Sensor (MWTS)

This slide presentation reviews the development of Multiple Waveband Temperature Sensor (MWTS). The MWTS project will result in a highly stable, monolithically integrated, high resolution infrared detector array sensor that records registered thermal imagery in four infrared wavebands to infer dynamic temperature profiles on a laser-irradiated ground target. An accurate surface temperature measurement of a target in extreme environments in a non-intrusive manner is required. The development challenge is to: determine optimum wavebands (suitable for target temperatures, nature of the targets and environments) to measure accurate target surface temperature independent of the emissivity, integrate simultaneously readable multiband Quantum Well Infrared Photodetectors (QWIPs) in a single monolithic focal plane array (FPA) sensor and to integrate the hardware/software and system calibration for remote temperature measurements. The charge was therefore to develop and demonstrate a multiband infrared imaging camera with the detectors simultaneously sensitive to multiple distinct color bands for front surface temperature measurements Wavelength ( m) measurements. Amongst the requirements are: that the measurement system will not affect target dynamics or response to the laser irradiation and that the simplest criterion for spectral band selection is to choose those practically feasible spectral bands that create the most contrast between the objects or scenes of interest in the expected environmental conditions. There is in the presentation a review of the modeling and simulation of multi-wave infrared temperature measurement and also a review of the detector development and QWIP capacities.

infrared photodector↗

Lunar Scout Infrared Detector (LSIRD): Simple low-cost imaging spectrometer

A novel design for a compact, light weight, imaging spectrometer has been proposed for an orbiting Lunar mapping mission. Simple in design, its dual arm optical system employs a transmission grating and a dichroic mirror to provide continous two-octave spectral response. The grating's first order wavelengths are reflected into the SWIR arm, while the second order wavelenghts are transmitted to the VNIR arm. The instrument design is that of a push broom camera. It uses one of the detector(s) dimensions for spectral selection, the other detector(s) dimension for cross-track spatial selection, and the foward motion of the platform (in this case, a spececraft) for down-track spatial coverage.

Lunar↗

Investigation Of Prandtl-Ishlinskii Hysteresis Compensation for Deep Space Optical Communications Pointing Control

This paper studies the simulated performance of the Deep Space Optical Communication (DSOC) laser downlink pointing control system that has a pointing requirement at the sub-microradian scale. To achieve the required pointing precision, the DSOC Flight Laser Transceiver (FLT) point-ahead mirror (PAM) employs piezoelectric actuators, which are widely used in precision applications due to their high motion resolution, rapid response, and high output forces. However, a piezoelectric actuator's performance is often limited by nonlinearities in their response, most significantly hysteresis. To study the effect of hysteresis on our simulated pointing performance, an invertible hysteresis model is developed using the Classical Prantdl-Ishlinskii (CPI) method. The simulation includes models of DSOC hardware and electronic system components based on key parameters (bias, frequency response, noise), with the hysteresis modeled in the PAM piezo actuator dynamics. A Proportional-Integral controller provides feedback with measurements from two potential sources: strain gauge sensors or a photon-counting camera. To compensate for hysteresis behavior, a feedforward inverse CPI hysteresis model is implemented in the control system. Two CPI models are built using different sampling methods (uniform sampling and cosine spacing) and controller performance is compared. For the maximum command range of ±400 μrad at 1 mHz, results show that the feedforward combined with feedback control reduces output tracking error by 50% or 58% (to 0.20 or 0.38 μrad) compared to feedback control alone (from 0.40 or 0.90 μrad), corresponding to the uniform-sampled and cosine-sampled CPI models, respectively.

Marinello, Lindsey A.↗

Self-pulsing in a low-current hollow cathode discharge: From Townsend to glow discharge

We investigate the self-pulsing phenomenon of a low current cavity discharge in a cylindrical hollow cathode in pure argon. The waveforms of pulsed current and voltage are measured, and the time-averaged and time-resolved images of hollow cathode discharge are recorded by using high-speed intensified charge coupled device camera. The results show that the self-pulsing is a mode transition between low-current stage of Townsend discharge and high-current stage of glow discharge. During the self-pulsing, the current rising time relates to the dissipation of space charges, and the decay time relates to the reconstruction of the virtual anode by the accumulation of positive ions. Whether or not space charges can form and keep the virtual anode is responsible for the discharge mode and hence plays an important role in the self-pulsing phenomenon in low current hollow cathode discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observational Investigation of Solar Interior and Atmosphere

The Imaging Vector Magnetograph (IVM) has been modified to make it easier to observe at more than one spectral line. The cell holding the blocking filter has been replaced by a four-position filter wheel, so that changing to a different line is a matter of a few minutes rather than the several hours it used to take to disassemble the cell and install a new filter. Three new filters have been obtained, for Na 1589.6 nm, Fe 1630.25 nm, and H 1656.3 nm. The new filters have better bandpass profiles than the ones they replaced: somewhat wider, with flatter tops and steeper wings. This results in a reduction of parasitic light coming from adjacent Fabry-Perot orders, from seven percent to about two percent, and flattens the apparent continuum. The Mees CCD Imaging Spectrograph (MCCD) was upgraded under this grant, with a new control computer and data system. The camera was replaced with a faster, larger-format frame-transfer camera. Final integration of the upgrades is not yet complete, but tests indicate that the system cadence will be improved by a factor of five to ten, while increasing the spatial coverage by a factor of two (depending on observation options). Synoptic observations with the IVM and MCCD continue to be conducted daily, to the extent permitted by the fact that we have a single observer responsible for the observations. The older Haleakala Stokes Polarimeter is also used to make a daily vector magnetogram, normally of the region selected by the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) duty scientists. This instrument, however, is showing its age to the extent that its maintenance is becoming something of a challenge. We also run a white light full-disk imager and a video H alpha prominence camera, continuously during times of observations. Of particular interest, we obtained rapid-cadence observations of the 2003 July 15 white light flare with both the IVM and MCCD. The vector magnetograms show no obvious difference between the preflare and postflare configurations. The photospheric magnetogram sequence and H alpha spectra we obtained can be combined with spacecraft observations to construct a rather detailed picture of the events of this flare. Several papers are in preparation.

Kuhn, Jeffrey R.↗

Radiological Considerations Supporting the American Medical Isotope Producer Niowave

This report provides a summary of work performed by Savannah River National Laboratory (SRNL) during FY22 in support of Niowave, an American Medical Isotope Production (AMIP) facility. SRNL served in a technical support role, funded by NA-231, supporting Niowave in the beginning of non radiological functional testing of their airport facility in FY22. Through this agreement, SRNL provides Niowave access to subject matter experts (SMEs) for questions that may arise during the drafting of engineering plans, facility policies, and/or response procedures. This report summarizes discussions between SRNL and Niowave about guidance concerning issues with the floor of the hot cells, dispersible removable contamination (beta emitting fission product), hot cell operation specifically utilization of cameras or mirrors, and the process for removing contaminated waste from the hot cell. Lessons learned and other various resources provided to Niowave by SRNL during FY22 are referenced in this report. This work was funded through NNSA’s Office of Material Management and Minimization, Conversion Office (NA-231).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CCDs at Lick Observatory

Improved sensitivity to light and uniformity of response has been obtained using various surface treatments of thinned CCDs. Procedures are described and some results are shown. The Lick Observatory data acquisition system is briefly described. A new thermoelectrically-cooled CCD camera for telescope guiding has been designed and built. The camera is described and preliminary results at the telescope are given.

Robinson, Lloyd B.↗

A First Order Wavefront Estimation Algorithm for P1640 Calibrator

P1640 calibrator is a wavefront sensor working with the P1640 coronagraph and the Palomar 3000 actuator adaptive optics system (P3K) at the Palomar 200 inch Hale telescope. It measures the wavefront by interfering post-coronagraph light with a reference beam formed by low-pass filtering the blocked light from the coronagraph focal plane mask. The P1640 instrument has a similar architecture to the Gemini Planet Imager (GPI) and its performance is currently limited by the quasi-static speckles due to non-common path wavefront errors, which comes from the non-common path for the light to arrive at the AO wavefront sensor and the coronagraph mask. By measuring the wavefront after the coronagraph mask, the non-common path wavefront error can be estimated and corrected by feeding back the error signal to the deformable mirror (DM) of the P3K AO system. Here, we present a first order wavefront estimation algorithm and an instrument calibration scheme used in experiments done recently at Palomar observatory. We calibrate the P1640 calibrator by measuring its responses to poking DM actuators with a sparse checkerboard pattern at different amplitudes. The calibration yields a complex normalization factor for wavefront estimation and establishes the registration of the DM actuators at the pupil camera of the P1640 calibrator, necessary for wavefront correction. Improvement of imaging quality after feeding back the wavefront correction to the AO system demonstrated the efficacy of the algorithm.

Wavefront sensing↗

The Alignment and Phasing System for the Thirty Meter Telescope: Risk Mitigation and Status Update

Alignment and Phasing System (APS) is responsible for the optical alignment via starlight of the approximately 12,000 degrees of freedom of the primary, secondary and tertiary mirrors of Thirty Meter Telescope (TMT). APS is based on the successful Phasing Camera System (PCS) used to align the Keck Telescopes. Since the successful APS conceptual design in 2007, work has concentrated on risk mitigation, use case generation, and alignment algorithm development and improvement. Much of the risk mitigation effort has centered around development and testing of prototype APS software which will replace the current PCS software used at Keck. We present an updated APS design, example use cases and discuss, in detail, the risk mitigation efforts.

Optical Alignment↗

Investigating high speed phenomena in laser plasma interactions using dilation x-ray imager (invited)

The DIlation X-ray Imager (DIXI) is a new, high-speed x-ray framing camera at the National Ignition Facility (NIF) sensitive to x-rays in the range of ≈2–17 keV. DIXI uses the pulse-dilation technique to achieve a temporal resolution of less than 10 ps, a ≈10× improvement over conventional framing cameras currently employed on the NIF (≈100 ps resolution), and otherwise only attainable with 1D streaked imaging. The pulse-dilation technique utilizes a voltage ramp to impart a velocity gradient on the signal-bearing electrons. The temporal response, spatial resolution, and x-ray sensitivity of DIXI are characterized with a short x-ray impulse generated using the COMET laser facility at Lawrence Livermore National Laboratory. At the NIF a pinhole array at 10 cm from target chamber center (tcc) projects images onto the photocathode situated outside the NIF chamber wall with a magnification of ≈64×. DIXI will provide important capabilities for warm-dense-matter physics, high-energy-density science, and inertial confinement fusion, adding important capabilities to temporally resolve hot-spot formation, x-ray emission, fuel motion, and mix levels in the hot-spot at neutron yields of up to 10{sup 17}. We present characterization data as well as first results on electron-transport phenomena in buried-layer foil experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new absolute extreme ultraviolet image system designed for studying the radiated power of the Joint Texas Experimental Tokamak discharges

A bolometer imaging system mounted on different toroidal and poloidal locations used for radiation observation has been developed in the Joint Texas Experimental Tokamak (J-TEXT tokamak). Three miniature pinhole AXUV16ELG (16 elements absolute extreme ultraviolet silicon photodiodes) array cameras, which are settled down in the same toroidal position but in three different poloidal places, can provide a broad viewing angle that covers the whole plasma cross-section, and hence can measure the total radiated power and provide the radiated emissive profile, while nine AXUV10EL (10 elements absolute extreme ultraviolet silicon photodiodes) array cameras are divided into three groups and will be mounted on different toroidal locations to observe the toroidal radiated power distribution. Among these detectors, one element of the AXUV16ELG array is absolutely calibrated by the synchrotron radiation source to verify the system reliability. Although there are some discrepancies between the typical responsivity given by IRD Co. and the calibrated results, it is confirmed that the discrepancies have no major effect on the final result after the simulation. The details of the system as well as observations are presented in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MEASURING HIGH-PRECISION ASTROMETRY WITH THE INFRARED ARRAY CAMERA ON THE SPITZER SPACE TELESCOPE

The Infrared Array Camera (IRAC) on the Spitzer Space Telescope currently offers the greatest potential for high-precision astrometry of faint mid-IR sources across arcminute-scale fields, which would be especially valuable for measuring parallaxes of cold brown dwarfs in the solar neighborhood and proper motions of obscured members of nearby star-forming regions. To more fully realize IRAC's astrometric capabilities, we have sought to minimize the largest sources of uncertainty in astrometry with its 3.6 and 4.5 μm bands. By comparing different routines that estimate stellar positions, we have found that Point Response Function (PRF) fitting with the Spitzer Science Center's Astronomical Point Source Extractor produces both the smallest systematic errors from varying intra-pixel sensitivity and the greatest precision in measurements of positions. In addition, self-calibration has been used to derive new 7th and 8th order distortion corrections for the 3.6 and 4.5 μm arrays of IRAC, respectively. These corrections are suitable for data throughout the mission of Spitzer when a time-dependent scale factor is applied to the corrections. To illustrate the astrometric accuracy that can be achieved by combining PRF fitting with our new distortion corrections, we have applied them to archival data for a nearby star-forming region, arriving at total astrometric errors of ∼20 and 70 mas at signal to noise ratios of 100 and 10, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

The Feasibility of Motion Tracking Camera System for Magnetic Suspension Wind Tunnel Tests

The Entry Systems Modeling (ESM) Program at NASA has actively participated in the re-development of the Magnetic Suspension Balance System (MSBS) at the six-inch subsonic wind tunnel at NASA Langley Research Center. This initiative aims to enhance the MSBS system's capabilities, enabling the testing of stingless entry vehicle models at supersonic speeds. To achieve this, control algorithms are required to ensure magnetic levitation control and stability for models during free-oscillation dynamic responses. Currently, the system relies on electromagnetic position sensors to provide real-time 3 degrees of freedom in a rigid body. While this approach has proven successful for subsonic speeds, expanding testing under higher pressure conditions may necessitate the incorporation of real-time roll and pitch measurements to quantify the dynamic stability characteristics of the models in free-oscillation. In collaboration with Old Dominion University, the team at NASA Langley Research Center proposes the implementation of a motion-tracking camera system. This system will provide real-time five degrees of freedom output, which will be utilized within a closed feedback control system and a two-step system identification model to isolate aerodynamic forces from their corresponding magnetic forces. The motion-tracking cameras will offer precise and accurate control over the levitation system, facilitating precise and repeatable experiments within the wind tunnel. The real-time feedback provided by the cameras enables prompt adjustments to ensure the maintenance of stable levitation throughout the testing process.

Entry Systems Modeling↗

The Feasibility of Motion Tracking Camera System for Magnetic Suspension Wind Tunnel Tests

The Entry Systems Modeling (ESM) Program at NASA has actively participated in the re-development of the Magnetic Suspension Balance System (MSBS) at the six-inch subsonic wind tunnel at NASA Langley Research Center. This initiative aims to enhance the MSBS system's capabilities, enabling the testing of stingless entry vehicle models at supersonic speeds. To achieve this, control algorithms are required to ensure magnetic levitation control and stability for models during free-oscillation dynamic responses. Currently, the system relies on electromagnetic position sensors to provide real-time 3 degrees of freedom in a rigid body. While this approach has proven successful for subsonic speeds, expanding testing under higher pressure conditions may necessitate the incorporation of real-time roll and pitch measurements to quantify the dynamic stability characteristics of the models in free-oscillation. In collaboration with Old Dominion University, the team at NASA Langley Research Center proposes the implementation of a motion-tracking camera system. This system will provide real-time five degrees of freedom output, which will be utilized within a closed feedback control system and a two-step system identification model to isolate aerodynamic forces from their corresponding magnetic forces. The motion-tracking cameras will offer precise and accurate control over the levitation system, facilitating precise and repeatable experiments within the wind tunnel. The real-time feedback provided by the cameras enables prompt adjustments to ensure the maintenance of stable levitation throughout the testing process.

Entry Systems Modeling↗

Is flat fielding safe for precision CCD astronomy?

The ambitious goals of precision cosmology with wide-field optical surveys such as the Dark Energy Survey (DES) and the Large Synoptic Survey Telescope (LSST) demand precision CCD astronomy as their foundation. This in turn requires an understanding of previously uncharacterized sources of systematic error in CCD sensors, many of which manifest themselves as static effective variations in pixel area. Such variation renders a critical assumption behind the traditional procedure of flat fielding—that a sensor's pixels comprise a uniform grid—invalid. In this work, we present a method to infer a curl-free model of a sensor's underlying pixel grid from flat-field images, incorporating the superposition of all electrostatic sensor effects—both known and unknown—present in flat-field data. We use these pixel grid models to estimate the overall impact of sensor systematics on photometry, astrometry, and PSF shape measurements in a representative sensor from the Dark Energy Camera (DECam) and a prototype LSST sensor. Applying the method to DECam data recovers known significant sensor effects for which corrections are currently being developed within DES. For an LSST prototype CCD with pixel-response non-uniformity (PRNU) of 0.4%, we find the impact of "improper" flat fielding on these observables is negligible in nominal .7'' seeing conditions. Furthermore, these errors scale linearly with the PRNU, so for future LSST production sensors, which may have larger PRNU, our method provides a way to assess whether pixel-level calibration beyond flat fielding will be required.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Source Characterization. Year 2 of 3 Summary

The neutron scatter camera (NSC), an imaging spectrometer for fission energy neutrons, is an established and proven detector for nuclear security applications such as weak source detection of special nuclear material (SNM), arms control treaty verification, and emergency response. Relative to competing technologies such as coded aperture imaging, time-encoded imaging, neutron time projection chamber, and various thermal neutron imagers, the NSC provides excellent event-by-event directional information for signal/background discrimination, reasonable imaging resolution, and good energy resolution. Its primary drawback is very low detection efficiency due to the requirement for neutron elastic scatters in two detector cells. We will develop a singlevolume double-scatter neutron imager, in which both neutron scatters can occur in the same large active volume. If successful, the efficiency will be dramatically increased over the current NSC cell-based geometry. If the detection efficiency approaches that of e.g. coded aperture imaging, the other inherent advantages of double-scatter imaging would make it the most attractive fast neutron detector for a wide range of security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

KidSat: Image User's Manual

The goal of KidSat was to provide young students with the opportunity to participate directly in the NASA space program and to enhance learning in the process. The KidSat pilot project was focused on using a color digital camera, mounted on the space shuttle, to take pictures of the Earth. These could be used to enhance middle school curricula. The project not only benefited middle school students, who were essentially the Science Team, responsible for deciding where to take pictures, but it also benefited high school students and undergraduates, who were essentially the Project Team, responsible for the development and implementation of the project. KidSat flew on three missions as part of the pilot project: STS-76, STS-81, and STS-86. This document describes the goals, project elements, results, and data for the three KidSat missions that made up the pilot program. It serves as a record for this pilot project and may be used as a reference for similar projects. It can also be a too] in using the data to its fullest extent. The KidSat Web page remains on-line at http://kidsat.jpl.nasa.gov/kidsat, and the images may be downloaded in their full resolution.

Way, JoBea↗

Calculation of spatial response of 2D beam emission spectroscopy diagnostic on MAST

The beam emission spectroscopy (BES) turbulence diagnostic on MAST is to be upgraded in June 2010 from a one-dimensional trial system to a two-dimensional imaging system (8 radialx4 poloidal channels) based on a newly developed avalanche photodiode array camera. The spatial resolution of the new system is calculated in terms of the point spread function to account for the effects of field-line curvature, observation geometry, the finite lifetime of the excited state of the beam atoms, and beam attenuation and divergence. It is found that the radial spatial resolution is {approx}2-3 cm and the poloidal spatial resolution {approx}1-5 cm depending on the radial viewing location. The absolute number of detected photons is also calculated, hence the photon noise level can be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗