Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “agreements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation

This study introduces a charge coupled device (CCD) area detector based optical-computed tomography (optical-CT) scanner for comprehensive verification of radiation dose distributions recorded in nonscattering radiochromic dosimeters. Defining characteristics include: (i) a very fast scanning time of {approx}5 min to acquire a complete three-dimensional (3D) dataset, (ii) improved image formation through the use of custom telecentric optics, which ensures accurate projection images and minimizes artifacts from scattered and stray-light sources, and (iii) high resolution (potentially 50 {mu}m) isotropic 3D dose readout. The performance of the CCD scanner for 3D dose readout was evaluated by comparison with independent 3D readout from the single laser beam OCTOPUS-scanner for the same PRESAGE dosimeters. The OCTOPUS scanner was considered the 'gold standard' technique in light of prior studies demonstrating its accuracy. Additional comparisons were made against calculated dose distributions from the ECLIPSE treatment-planning system. Dose readout for the following treatments were investigated: (i) a single rectangular beam irradiation to investigate small field and very steep dose gradient dosimetry away from edge effects, (ii) a 2-field open beam parallel-opposed irradiation to investigate dosimetry along steep dose gradients, and (iii) a 7-field intensity modulated radiation therapy (IMRT) irradiation to investigate dosimetry for complex treatment delivery involving modulation of fluence and for dosimetry along moderate dose gradients. Dose profiles, dose-difference plots, and gamma maps were employed to evaluate quantitative estimates of agreement between independently measured and calculated dose distributions. Results indicated that dose readout from the CCD scanner was in agreement with independent gold-standard readout from the OCTOPUS-scanner as well as the calculated ECLIPSE dose distribution for all treatments, except in regions within a few millimeters of the edge of the dosimeter, where edge artifact is predominant. Agreement of line profiles was observed, even along steep dose gradients. Dose difference plots indicated that the CCD scanner dose readout differed from the OCTOPUSscanner readout and ECLIPSE calculations by {approx}10% along steep dose gradients and by {approx}5% along moderate dose gradients. Gamma maps (3% dose-difference and 3 mm distance-to-agreement acceptance criteria) revealed agreement, except for regions within 5 mm of the edge of the dosimeter where the edge artifact occurs. In summary, the data demonstrate feasibility of using the fast, high-resolution CCD scanner for comprehensive 3D dosimetry in all applications, except where dose readout is required close to the edges of the dosimeter. Further work is ongoing to reduce this artifact.

61 RADIATION PROTECTION AND DOSIMETRY↗

Modeling the TrueBeam linac using a CAD to Geant4 geometry implementation: Dose and IAEA-compliant phase space calculations

Purpose: To create an accurate 6 MV Monte Carlo simulation phase space for the Varian TrueBeam treatment head geometry imported from cad (computer aided design) without adjusting the input electron phase space parameters. Methods: geant4 v4.9.2.p01 was employed to simulate the 6 MV beam treatment head geometry of the Varian TrueBeam linac. The electron tracks in the linear accelerator were simulated with Parmela, and the obtained electron phase space was used as an input to the Monte Carlo beam transport and dose calculations. The geometry components are tessellated solids included in geant4 as gdml (generalized dynamic markup language) files obtained via STEP (standard for the exchange of product) export from Pro/Engineering, followed by STEP import in Fastrad, a STEP-gdml converter. The linac has a compact treatment head and the small space between the shielding collimator and the divergent arc of the upper jaws forbids the implementation of a plane for storing the phase space. Instead, an IAEA (International Atomic Energy Agency) compliant phase space writer was implemented on a cylindrical surface. The simulation was run in parallel on a 1200 node Linux cluster. The 6 MV dose calculations were performed for field sizes varying from 4 x 4 to 40 x 40 cm{sup 2}. The voxel size for the 60x60x40 cm{sup 3} water phantom was 4x4x4 mm{sup 3}. For the 10x10 cm{sup 2} field, surface buildup calculations were performed using 4x4x2 mm{sup 3} voxels within 20 mm of the surface. Results: For the depth dose curves, 98% of the calculated data points agree within 2% with the experimental measurements for depths between 2 and 40 cm. For depths between 5 and 30 cm, agreement within 1% is obtained for 99% (4x4), 95% (10x10), 94% (20x20 and 30x30), and 89% (40x40) of the data points, respectively. In the buildup region, the agreement is within 2%, except at 1 mm depth where the deviation is 5% for the 10x10 cm{sup 2} open field. For the lateral dose profiles, within the field size for fields up to 30x30 cm{sup 2}, the agreement is within 2% for depths up to 10 cm. At 20 cm depth, the in-field maximum dose difference for the 30x30 cm{sup 2} open field is within 4%, while the smaller field sizes agree within 2%. Outside the field size, agreement within 1% of the maximum dose difference is obtained for all fields. The calculated output factors varied from 0.938{+-}0.015 for the 4x4 cm{sup 2} field to 1.088{+-}0.024 for the 40x40 cm{sup 2} field. Their agreement with the experimental output factors is within 1%. Conclusions: The authors have validated a geant4 simulated IAEA-compliant phase space of the TrueBeam linac for the 6 MV beam obtained using a high accuracy geometry implementation from cad. These files are publicly available and can be used for further research.

43 PARTICLE ACCELERATORS↗

Accuracy of Acuros XB and AAA dose calculation for small fields with reference to RapidArc stereotactic treatments

Purpose: To assess the accuracy against measurements of two photon dose calculation algorithms (Acuros XB and the Anisotropic Analytical algorithm AAA) for small fields usable in stereotactic treatments with particular focus on RapidArc. Methods: Acuros XB and AAA were configured for stereotactic use. Baseline accuracy was assessed on small jaw-collimated open fields for different values for the spot sizes parameter in the beam data: 0.0, 0.5, 1, and 2 mm. Data were calculated with a grid of 1 x 1 mm{sup 2}. Investigated fields were: 3 x 3, 2 x 2, 1 x 1, and 0.8 x 0.8 cm{sup 2} with a 6 MV photon beam generated from a Clinac2100iX (Varian, Palo Alto, CA). Profiles, PDD, and output factors were measured in water with a PTW diamond detector (detector size: 4 mm{sup 2}, thickness 0.4 mm) and compared to calculations. Four RapidArc test plans were optimized, calculated and delivered with jaw settings J3 x 3, J2 x 2, and J1 x 1 cm{sup 2}, the last was optimized twice to generate high (H) and low (L) modulation patterns. Each plan consisted of one partial arc (gantry 110 deg. to 250 deg.), and collimator 45 deg. Dose to isocenter was measured in a PTW Octavius phantom and compared to calculations. 2D measurements were performed by means of portal dosimetry with the GLAaS method developed at authors' institute. Analysis was performed with gamma pass-fail test with 3% dose difference and 2 mm distance to agreement thresholds. Results: Open square fields: penumbrae from open field profiles were in good agreement with diamond measurements for 1 mm spot size setting for Acuros XB, and between 0.5 and 1 mm for AAA. Maximum MU difference between calculations and measurements was 1.7% for Acuros XB (0.2% for fields greater than 1 x 1 cm{sup 2}) with 0.5 or 1 mm spot size. Agreement for AAA was within 0.7% (2.8%) for 0.5 (1 mm) spot size. RapidArc plans: doses were evaluated in a 4 mm diameter structure at isocenter and computed values differed from measurements by 0.0, -0.2, 5.5, and -3.4% for Acuros XB calculations (1 mm spot size), and of -0.1, 0.3, 6.7, and -1.2% for AAA, respectively for J3 x 3, J2 x 2, J1 x 1H, J1 x 1L RapidArc plans. Gamma Agreement Index from 2D dose analysis was higher than 95% for J3 x 3 and J2 x 2 plans, being around 80% for J1 x 1 maps. Sensitivity with respect to the dosimetric leaf gap and transmission factor MLC parameters was evaluated in the four RapidArc plans, showing the need to properly set the dosimetric leaf gap for accurate calculations. Conclusions: Acuros XB and AAA showed acceptable characteristics for stereotactic small fields if adequate tuning of configuration parameters is performed. Dose calculated for RapidArc stereotactic plans showed an acceptable agreement against point and 2D measurements. Both algorithms can therefore be considered safely applicable to stereotactic treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac

Purpose: To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for rendering the phase-space data compatible with BEAMnrc/DOSXYZnrc simulation software package is presented. Methods: Monte Carlo (MC) simulations were performed to benchmark the TrueBeam 6 MV FFF phase space data that have been released by the Varian MC Research team. The simulations to benchmark the phase space data were done in three steps. First, the original phase space which was created on a cylindrical surface was converted into a format that was compatible with BEAMnrc. Second, BEAMnrc was used to create field size specific phase spaces located underneath the jaws. Third, doses were calculated with DOSXYZnrc in a water phantom for fields ranging from 1 Multiplication-Sign 1 to 40 Multiplication-Sign 40 cm{sup 2}. Calculated percent depth doses (PDD), transverse profiles, and output factors were compared with measurements for all the fields simulated. After completing the benchmarking study, three stereotactic body radiotherapy (SBRT) VMAT plans created with the Eclipse treatment planning system (TPS) were calculated with Monte Carlo. Ion chamber and film measurements were also performed on these plans. 3D gamma analysis was used to compare Monte Carlo calculation with TPS calculations and with film measurement. Results: For the benchmarking study, MC calculated and measured values agreed within 1% and 1.5% for PDDs and in-field transverse profiles, respectively, for field sizes >1 Multiplication-Sign 1 cm{sup 2}. Agreements in the 80%-20% penumbra widths were better than 2 mm for all the fields that were compared. With the exception of the 1 Multiplication-Sign 1 cm{sup 2} field, the agreement between measured and calculated output factors was within 1%. It is of note that excellent agreement in output factors for all field sizes including highly asymmetric fields was achieved without accounting for backscatter into the beam monitor chamber. For the SBRT VMAT plans, the agreement between Monte Carlo and ion chamber point dose measurements was within 1%. Excellent agreement between Monte Carlo, treatment planning system and Gafchromic film dose distribution was observed with over 99% of the points in the high dose volume passing the 3%, 3 mm gamma test. Conclusions: The authors have presented a method for making the Varian IAEA compliant 6 MV FFF phase space file of the TrueBeam linac compatible with BEAMnrc/DOSXYZnrc. After benchmarking the modified phase space against measurement, they have demonstrated its potential for use in MC based quality assurance of complex delivery techniques.

60 APPLIED LIFE SCIENCES↗

Monte Carlo simulation of TrueBeam flattening-filter-free beams using Varian phase-space files: Comparison with experimental data

Purpose: Phase-space files for Monte Carlo simulation of the Varian TrueBeam beams have been made available by Varian. The aim of this study is to evaluate the accuracy of the distributed phase-space files for flattening filter free (FFF) beams, against experimental measurements from ten TrueBeam Linacs. Methods: The phase-space files have been used as input in PRIMO, a recently released Monte Carlo program based on thePENELOPE code. Simulations of 6 and 10 MV FFF were computed in a virtual water phantom for field sizes 3 × 3, 6 × 6, and 10 × 10 cm{sup 2} using 1 × 1 × 1 mm{sup 3} voxels and for 20 × 20 and 40 × 40 cm{sup 2} with 2 × 2 × 2 mm{sup 3} voxels. The particles contained in the initial phase-space files were transported downstream to a plane just above the phantom surface, where a subsequent phase-space file was tallied. Particles were transported downstream this second phase-space file to the water phantom. Experimental data consisted of depth doses and profiles at five different depths acquired at SSD = 100 cm (seven datasets) and SSD = 90 cm (three datasets). Simulations and experimental data were compared in terms of dose difference. Gamma analysis was also performed using 1%, 1 mm and 2%, 2 mm criteria of dose-difference and distance-to-agreement, respectively. Additionally, the parameters characterizing the dose profiles of unflattened beams were evaluated for both measurements and simulations. Results: Analysis of depth dose curves showed that dose differences increased with increasing field size and depth; this effect might be partly motivated due to an underestimation of the primary beam energy used to compute the phase-space files. Average dose differences reached 1% for the largest field size. Lateral profiles presented dose differences well within 1% for fields up to 20 × 20 cm{sup 2}, while the discrepancy increased toward 2% in the 40 × 40 cm{sup 2} cases. Gamma analysis resulted in an agreement of 100% when a 2%, 2 mm criterion was used, with the only exception of the 40 × 40 cm{sup 2} field (∼95% agreement). With the more stringent criteria of 1%, 1 mm, the agreement reduced to almost 95% for field sizes up to 10 × 10 cm{sup 2}, worse for larger fields. Unflatness and slope FFF-specific parameters are in line with the possible energy underestimation of the simulated results relative to experimental data. Conclusions: The agreement between Monte Carlo simulations and experimental data proved that the evaluated Varian phase-space files for FFF beams from TrueBeam can be used as radiation sources for accurate Monte Carlo dose estimation, especially for field sizes up to 10 × 10 cm{sup 2}, that is the range of field sizes mostly used in combination to the FFF, high dose rate beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-645: Qualification of a 2D Ionization Chamber Array for Beam Steering and Profile Measurement

Purpose: Establish a procedure for beam steering and profile measurement using a 2D ionization chamber array and show equivalence to a water scanning system. Methods: Multiple photon beams (30×30cm{sup 2} field) and electron beams (25×25cm{sup 2} cone) were steered in the radial and transverse directions using Sun Nuclear’s IC PROFILER (ICP). Solid water was added during steering to ensure measurements were beyond the buildup region. With steering complete, servos were zeroed and enabled. Photon profiles were collected in a 30×30cm{sup 2} field at dmax and 2.9 cm depth for flattened and FFF beams respectively. Electron profiles were collected with a 25×25cm{sup 2} cone and effective depth (solid water + 0.9 cm intrinsic buildup) as follows: 0.9 cm (6e), 1.9 cm (9e), 2.9 cm (12e, 16e, 20e). Profiles of the same energy, field size and depth were measured in water with Sun Nuclear’s 3D SCANNER (3DS). Profiles were re-measured using the ICP after the in-water scans. Profiles measured using the ICP and 3DS were compared by (a) examining the differences in Varian’s “Point Difference Symmetry” metric, (b) visual inspection of the overlaid profile shapes and (c) calculation of point-by-point differences. Results: Comparing ICP measurements before and after water scanning showed very good agreement indicating good stability of the linac and measurement system. Comparing ICP Measurements to water phantom measurements using Varian’s symmetry metric showed agreement within 0.5% for all beams. The average magnitude of the agreement was within 0.2%. Comparing ICP Measurements to water phantom measurements using point-by-point difference showed agreement within 0.5% inside of 80% area of the field width. Conclusion: Profile agreement to within 0.5% was observed between ICP and 3DS after steering multiple energies with the ICP. This indicates that the ICP may be used for steering electron beams, and both flattened and FFF photon beams. Song Gao: Sun Nuclear’s invitation of speak and financial support for attending the 8th QA & Dosimetry Symposium in Orlando, Florida 2015.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-487: On-Site Beam Matching of An Elekta Infinity with Agility MLC with An Elekta Versa HD

Purpose: Historically, beam matching of similar Linear Accelerators has been accomplished by sending beam data to the manufacturer to match at their factory. The purpose of this work is to demonstrate that fine beam matching can be carried out on-site as part of the acceptance test, with similar or better results. Methods: Initial scans of a 10 × 10 Percent depth dose (PDD) and a 40 × 40 beam profile at the depth of Dmax, for 6MV and 10 MV were taken to compare with the standard beam data from the Versa. The energy was then adjusted and the beam steered to achieve agreement between the depth dose and the horns of the beam profile. This process was repeated until the best agreement between PDD and profiles was achieved. Upon completion, all other clinical data were measured to verify match. This included PDD, beam profiles, output factors and Wedge factors. For electron beams PDD’s were matched and the beam profiles verified for the final beam energy. Confirmatory PDD and beam profiles for clinical field sizes, as well as Output Factors were measured. Results: The average difference in PDD’s for 6MV and 10MV were within 0.4% for both wedged and open fields. Beam profile comparisons over the central 80% of the field, at multiple depths, show agreement of 0.8% or less for both wedged and open fields. Average output factor agreement over all field sizes was 0.4% for 6MV and 0.2 % for 10MV. Wedge factors agreement was less than 0.6% for both photon energies over all field sizes. Electron PDD agreed to 0.5mm. Cone ratios agreed to 1% or less. Conclusion: This work indicates that beam matching can be carried out on-site simply and quickly. The results of this beam matching can achieve similar or better results than factory matching.

43 PARTICLE ACCELERATORS↗

Progress Report, December 2010: Improved Site Characterization And Storage Prediction Through Stochastic Inversion Of Time-Lapse Geophysical And Geochemical Data

Over the last project six months, our project activities have concentrated on three areas: (1) performing a stochastic inversion of pattern 16 seismic data to deduce reservoir permeability, (2) development of the geochemical inversion strategy and implementation of associated software, and (3) completing the software implementation of TProGS and the geostatistical analysis that provides the information needed when using the software to produce realizations of the Midale reservoir. The report partially the following deliverables: D2: Model development: MCMC tool (synthetic fluid chemistry data); deliverable completed. D4: Model development/verification: MCMC tool (TProGS, field seismic/chemistry data) work product; deliverable requirements partially fulfilled. D5: Field-based single-pattern simulations work product; deliverable requirements partially fulfilled. When completed, our completed stochastic inversion tool will explicitly integrate reactive transport modeling, facies-based geostatistical methods, and a novel stochastic inversion technique to optimize agreement between observed and predicted storage performance. Such optimization will be accomplished through stepwise refinement of: (1) the reservoir model - principally its permeability magnitude and heterogeneity - and (2) geochemical parameters - primarily key mineral volume fractions and kinetic data. We anticipate that these refinements will facilitate significantly improved history matching and forward modeling of CO{sub 2} storage. Our tool uses the Markov Chain Monte Carlo (MCMC) methodology. Deliverable D1, previously submitted as a report titled ''Development of a Stochastic Inversion Tool To Optimize Agreement Between The Observed And Predicted Seismic Response To CO{sub 2} Injection/Migration in the Weyburn-Midale Project'' (Ramirez et al., 2009), described the stochastic inversion approach that will identify reservoir models that optimize agreement between the observed and predicted seismic response. The software that implements this approach has been completed, tested, and used to process seismic data from pattern 16. A previously submitted report titled ''Model verification: synthetic single pattern simulations using seismic reflection data'', Ramirez et al. 2010, partially fulfilled deliverable D3 by summarizing verification activities that evaluate the performance of the seismic software and its ability to recover reservoir model permeabilities using synthetic seismic reflection data. A future progress report will similarly describe summarizing verification activities of the geochemical inversion software, thereby completing deliverable D3. This document includes a chapter that shows and discusses permeability models produced by seismic inversion that used seismic data from pattern 16 in Phase 1A. It partially fulfills deliverable D5: Field-based single-pattern simulations work product. The D5 work product is supposed to summarize the results of applying NUFT/MCMC to refine the reservoir model and geochemical parameters by optimizing observation/prediction agreement for the seismic/geochemical response to CO{sub 2} injection/migration within a single pattern of Phase 1A/1B. A future progress report will show inversion results for the same pattern using geochemical data, thereby completing deliverable D5. This document also contains a chapter that fulfills deliverable D2: Model development: MCMC tool (synthetic fluid chemistry data). The chapter will summarize model development activities required to facilitate application of NUFT/MCMC to optimize agreement between the observed and predicted geochemical response to CO{sub 2} injection/migration. Lastly, this document also contains a chapter that partially fulfills deliverable D4: Model development/verification: MCMC tool (TProGS, field seismic/chemistry data) work product. This work product is supposed to summarize model development activities required for (1) application of TProGS to Weyburn, (2) use of TProGS within the MCMC tool, and (3) application of the MCMC tool to address field seismic and geochemical data. The chapter included here fulfills requirements 1 and 2. Requirement 3 will be addressed in a future progress report.

58 GEOSCIENCES↗

The Challenge for Arms Control Verification in the Post-New START World

Nuclear weapon arms control treaty verification is a key aspect of any agreement between signatories to establish that the terms and conditions spelled out in the treaty are being met. Historically, arms control negotiations have focused more on the rules and protocols for reducing the numbers of warheads and delivery systems - sometimes resorting to complex and arcane procedures for counting forces - in an attempt to address perceived or real imbalances in a nation's strategic posture that could lead to instability. Verification procedures are generally defined in arms control treaties and supporting documents and tend to focus on technical means and measures designed to ensure that a country is following the terms of the treaty and that it is not liable to engage in deception or outright cheating in an attempt to circumvent the spirit and the letter of the agreement. As the Obama Administration implements the articles, terms, and conditions of the recently ratified and entered-into-force New START treaty, there are already efforts within and outside of government to move well below the specified New START levels of 1550 warheads, 700 deployed strategic delivery vehicles, and 800 deployed and nondeployed strategic launchers (Inter-Continental Ballistic Missile (ICBM) silos, Submarine-Launched Ballistic Missile (SLBM) tubes on submarines, and bombers). A number of articles and opinion pieces have appeared that advocate for significantly deeper cuts in the U.S. nuclear stockpile, with some suggesting that unilateral reductions on the part of the U.S. would help coax Russia and others to follow our lead. Papers and studies prepared for the U.S. Department of Defense and at the U.S. Air War College have also been published, suggesting that nuclear forces totaling no more than about 300 warheads would be sufficient to meet U.S. national security and deterrence needs. (Davis 2011, Schaub and Forsyth 2010) Recent articles by James M. Acton and others suggest that the prospects for maintaining U.S. security and minimizing the chances of nuclear war, while deliberately reducing stockpiles to a few hundred weapons, is possible but not without risk. While the question of the appropriate level of cuts to U.S. nuclear forces is being actively debated, a key issue continues to be whether verification procedures are strong enough to ensure that both the U.S. and Russia are fulfilling their obligations under the current New Start treaty and any future arms reduction treaties. A recent opinion piece by Henry Kissinger and Brent Scowcroft (2012) raised a number of issues with respect to governing a policy to enhance strategic stability, including: in deciding on force levels and lower numbers, verification is crucial. Particularly important is a determination of what level of uncertainty threatens the calculation of stability. At present, that level is well within the capabilities of the existing verification systems. We must be certain that projected levels maintain - and when possible, reinforce - that confidence. The strengths and weaknesses of the New START verification regime should inform and give rise to stronger regimes for future arms control agreements. These future arms control agreements will likely need to include other nuclear weapons states and so any verification regime will need to be acceptable to all parties. Currently, China is considered the most challenging party to include in any future arms control agreement and China's willingness to enter into verification regimes such as those implemented in New START may only be possible when it feels it has reached nuclear parity with the U.S. and Russia. Similarly, in keeping with its goals of reaching peer status with the U.S. and Russia, Frieman (2004) suggests that China would be more willing to accept internationally accepted and applied verification regimes rather than bilateral ones. The current verification protocols specified in the New START treaty are considered as the baseline case and are contrasted with possible alternative verification protocols that could be effective in a post-New START era of significant reductions in U.S. and other countries nuclear stockpiles. Of particular concern is the possibility of deception and breakout when declared and observed numbers of weapons are below the level considered to pose an existential threat to the U.S. In a regime of very low stockpile numbers, 'traditional' verification protocols as currently embodied in the New START treaty might prove less than adequate. I introduce and discuss a number of issues that need to be considered in future verification protocols, many of which do not have immediate solutions and so require further study. I also discuss alternatives and enhancements to traditional verification protocols, for example, confidence building measures such as burden sharing against the common threat of weapon of mass destruction (WMD) terrorism, joint research and development.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Kansas Consortium Plug-in Hybrid Medium Duty

On September 30, 2008, the US Department of Energy (DoE), issued a cooperative agreement award, DE-FC26-08NT01914, to the Metropolitan Energy Center (MEC), for a project known as “Kansas Consortium Plug-in Hybrid Medium Duty Certification” project. The cooperative agreement was awarded pursuant to H15915 in reference to H. R. 2764 Congressionally Directed Projects. The original agreement provided funding for The Consortium to implement the established project objectives as follows: (1) to understand the current state of the development of a test protocol for PHEV configurations; (2) to work with industry stakeholders to recommend a medium duty vehicle test protocol; (3) to utilize the Phase 1 Eaton PHEV F550 Chassis or other appropriate PHEV configurations to conduct emissions testing; (4) and to make an industry PHEV certification test protocol recommendation for medium duty trucks. Subsequent amendments to the initial agreement were made, the most significant being a revised Scope of Project Objectives (SOPO) that did not address actual field data since it was not available as originally expected. This project was mated by DOE with a parallel project award given to the South Coast Air Quality Management District (SCAQMD) in California. The SCAQMD project involved designing, building and testing of five medium duty plug-in hybrid electric trucks. SCAQMD had contracted with the Electric Power Research Institute (EPRI) to manage the project. EPRI provided the required match to the federal grant funds to both the SCAQMD project and the Kansas Consortium project. The rational for linking the two projects was that the data derived from the SCAQMD project could be used to validate the protocols developed by the Kansas Consortium team. At the same time, the consortium team would be a useful resource to SCAQMD in designating their test procedures for emissions and operating parameters and determining vehicle mileage. The years between award of the cooperative agreements and their completion were problematic for the US and world economies. This resulted in the President and Congress implementing the American Recovery and Reinvestment Act of 2009, abbreviated ARRA (Pub.L. 111-5), commonly referred to as the Stimulus or The Recovery Act. The stimulus money available for transportation projects encouraged the SCAQMD to seek additional funds. In August of 2009, they eventually were awarded an additional $45.5 M, and the scope of their project was expanded to 378 vehicles. However, as a consequence of the stimulus money and the inundation of DOE with applications for new project under the ARRA, the expected time table for producing and testing vehicles was significantly delayed. As a result, these vehicles were not available for validating the protocols developed by the Kansas Consortium. Therefore, in April of 2011, the Scope of Project Objectives (SOPO) for the project was revised, and limited to producing the draft protocol for PHEV certification as its deliverable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term Surveillance Plan for the Naturita, Colorado, Disposal Site

This Long-Term Surveillance Plan (LTSP) explains how the U.S. Department of Energy (DOE) will fulfill general license requirements of Title 10 Code of Federal Regulations Part 40.27 (10 CFR 40.27) as the licensee at the Naturita, CO, Disposal Site (site) and revises the original LTSP (DOE 1999). This revision incorporates changes that reflect the U.S. Nuclear Regulatory Commission (NRC) concurrence on April 15, 2014, with a request from the DOE Office of Legacy Management (LM) to terminate groundwater monitoring at the site (Appendix D). In addition, the title of the LTSP has been changed from Long-Term Surveillance Plan for the Upper Burbank Disposal Cell, Uravan, Colorado , because the town of Uravan no longer exists and the Upper Burbank disposal cell is now referred to as the Naturita disposal cell. Appendix B has been revised to include documentation of a 2003 agreement in which the Bureau of Land Management provides a right-of-way to DOE for the east and west toe drains (identified in the agreement as two storm water drainage structures) and a 2011 agreement in which Umetco Minerals Corporation (Umetco) allows DOE access to the west toe drain outlet (identified in the agreement as a diversion channel). These agreements were put in place after acceptance of the original LTSP, and they are included in this revised LTSP as a best management practice to maintain protectiveness and to inform all stewards of site conditions and controls.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Repurposing Offshore Infrastructure for Clean Energy (ROICE) vs. Decommissioning – Commercial Considerations

Abstract The Repurposing Offshore Infrastructure for Clean Energy (ROICE) Program, a collaboration of the energy industry and University of Houston, proposes extending the life of up to 1,500 oil and gas platforms in the Outer Continental Shelf of the Gulf of Mexico, USA. Rather than decommissioning or converting them to underwater reefs at the end of their oil and gas production phase, the platforms could be transformed for 10–20+ years of renewable energy development, such as green hydrogen production or carbon dioxide injection and storage, resulting in significant economic, environmental, and social benefits. ROICE has already published papers on the technical and regulatory considerations for such repurposing projects. This paper focuses on the commercial considerations needed to ensure ROICE projects are economically viable and sustainable for all involved. There are potentially many entities that can come together to progress a repurposing project, including oil and gas asset owners, operators, investors, developers, contractors, manufacturers, and regulators. This paper looks at possible combinations of these entities in a ROICE project team and the various commercial agreements that will be needed to ensure a mutually successful outcome. The paper proposes adapting existing industry agreements and templates to suit, including asset transfer agreements (ATA), asset purchase agreements (APA) and joint purchasing agreements (JOA). An ATA or APA can be drafted to address the obligations and issues involved in the sale or transfer of an existing oil and gas facility to the developer, operator, non-operating interests, and financial investors in a ROICE project, while a JOA can be drafted to govern the rights, obligations, and financial requirements of the parties involved in the development and operation.

Legge, G. [Endeavor Management, USA]↗

The Fifth International Workshop on Ice Nucleation phase 2 (FIN-02): laboratory intercomparison of ice nucleation measurements

Abstract. The second phase of the Fifth International Ice Nucleation Workshop (FIN-02)involved the gathering of a large number of researchers at the KarlsruheInstitute of Technology's Aerosol Interactions and Dynamics of the Atmosphere(AIDA) facility to promote characterization and understanding of icenucleation measurements made by a variety of methods used worldwide.Compared to the previous workshop in 2007, participation was doubled,reflecting a vibrant research area. Experimental methods involved sampling ofaerosol particles by direct processing ice nucleation measuring systems fromthe same volume of air in separate experiments using different ice nucleatingparticle (INP) types, and collections of aerosol particle samples ontofilters or into liquid for sharing amongst measurement techniques thatpost-process these samples. In this manner, any errors introduced bydifferences in generation methods when samples are shared across laboratorieswere mitigated. Furthermore, as much as possible, aerosol particle sizedistribution was controlled so that the size limitations of different methodswere minimized. The results presented here use data from the workshop toassess the comparability of immersion freezing measurement methods activatingINPs in bulk suspensions, methods that activate INPs in condensation and/orimmersion freezing modes as single particles on a substrate, continuous flowdiffusion chambers (CFDCs) directly sampling and processing particles wellabove water saturation to maximize immersion and subsequent freezing ofaerosol particles, and expansion cloud chamber simulations in which liquidcloud droplets were first activated on aerosol particles prior to freezing.The AIDA expansion chamber measurements are expected to be the closestrepresentation to INP activation in atmospheric cloud parcels in thesecomparisons, due to exposing particles freely to adiabatic cooling. The different particle types used as INPs included the minerals illite NX andpotassium feldspar (K-feldspar), two natural soil dusts representative of arable sandy loam(Argentina) and highly erodible sandy dryland (Tunisia) soils, respectively,and a bacterial INP (Snomax ® ). Consideredtogether, the agreement among post-processed immersion freezing measurementsof the numbers and fractions of particles active at different temperaturesfollowing bulk collection of particles into liquid was excellent, withpossible temperature uncertainties inferred to be a key factor in determiningINP uncertainties. Collection onto filters for rinsing versus directly intoliquid in impingers made little difference. For methods that activatedcollected single particles on a substrate at a controlled humidity at orabove water saturation, agreement with immersion freezing methods was good inmost cases, but was biased low in a few others for reasons that have not beenresolved, but could relate to water vapor competition effects. AmongstCFDC-style instruments, various factors requiring (variable) highersupersaturations to achieve equivalent immersion freezing activation dominatethe uncertainty between these measurements, and for comparison with bulkimmersion freezing methods. When operated above water saturation to includeassessment of immersion freezing, CFDC measurements often measured at orabove the upper bound of immersion freezing device measurements, but oftenunderestimated INP concentration in comparison to an immersion freezingmethod that first activates all particles into liquid droplets prior tocooling (the PIMCA-PINC device, or Portable Immersion Mode Cooling chAmber–Portable Ice Nucleation Chamber), and typically slightly underestimated INPnumber concentrations in comparison to cloud parcel expansions in the AIDAchamber; this can be largely mitigated when it is possible to raise therelative humidity to sufficiently high values in the CFDCs, although this isnot always possible operationally. Correspondence of measurements of INPs among direct sampling andpost-processing systems varied depending on the INP type. Agreement was bestfor Snomax ® particles in the temperature regimecolder than −10 ∘ C, where their ice nucleation activity is nearlymaximized and changes very little with temperature. At temperatures warmer than −10 ∘ C, Snomax ® INP measurements (allvia freezing of suspensions) demonstrated discrepancies consistent withprevious reports of the instability of its protein aggregates that appear tomake it less suitable as a calibration INP at these temperatures. ForArgentinian soil dust particles, there was excellent agreement across allmeasurement methods; measures ranged within 1 order of magnitude for INPnumber concentrations, active fractions and calculated active site densitiesover a 25 to 30 ∘ C range and 5 to 8 orders of correspondingmagnitude change in number concentrations. This was also the case for alltemperatures warmer than −25 ∘ C in Tunisian dust experiments. Incontrast, discrepancies in measurements of INP concentrations or active sitedensities that exceeded 2 orders of magnitude across a broad range of temperaturemeasurements found at temperatures warmer than −25 ∘ C in a previous study werereplicated for illite NX. Discrepancies also exceeded 2 orders of magnitude attemperatures of −20 to −25 ∘ C for potassium feldspar (K-feldspar), but these coincidedwith the range of temperatures at which INP concentrations increase rapidly atapproximately an order of magnitude per 2 ∘ C cooling forK-feldspar. These few discrepancies did not outweigh the overall positive outcomes of theworkshop activity, nor the future utility of this data set or future similarefforts for resolving remaining measurement issues. Measurements of the samematerials were repeatable over the time of the workshop and demonstratedstrong consistency with prior studies, as reflected by agreement of databroadly with parameterizations of different specific or general (e.g., soildust) aerosol types. The divergent measurements of the INP activity of illiteNX by direct versus post-processing methods were not repeated for otherparticle types, and the Snomax ® datademonstrated that, at least for a biological INP type, there is no expectedmeasurement bias between bulk collection and direct immediately processedfreezing methods to as warm as −10 ∘ C. Since particle size rangeswere limited for this workshop, it can be expected that for atmosphericpopulations of INPs, measurement discrepancies will appear due to thedifferent capabilities of methods for sampling the full aerosol sizedistribution, or due to limitations on achieving sufficient watersupersaturations to fully capture immersion freezing in direct processinginstruments. Overall, this workshop presents an improved picture of presentcapabilities for measuring INPs than in past workshops, and providesdirection toward addressing remaining measurement issues.

54 ENVIRONMENTAL SCIENCES↗

The 27-28 October 1986 FIRE IFO Cirrus case study: Comparison of radiative transfer theory with observations by satellite and aircraft

Observations of cirrus and altocumulus clouds during the First International Satellite Cloud Climatology Project Regional Experiment (FIRE) are compared to theoretical models of cloud radiative properties. Three tests are performed. First, LANDSAT radiances are used to compare the relationship between nadir reflectance ot 0.83 micron and beam emittance at 11.5 microns with that predicted for model calculations using spherical and nonspherical phase functions. Good agreement is found between observations and theory when water droplets dominate. Poor agreement is found when ice particles dominate, especially using scattering phase functions for spherical particles. Even when compared to a laboratory measured ice particle phase function, the observations show increased side scattered radiation relative to the theoretical calculations. Second, the anisotropy of conservatively scattered radiation is examined using simultaneous multiple angle views of the cirrus from LANDSAT and ER-2 aircraft radiometers. Observed anisotropy gives good agreement with theoretical calculations using the laboratory measured ice particle phase function and poor agreement with a spherical particle phase function. Third, Landsat radiances at 0.83, 1.65, and 2.21 microns are used to infer particle phase and particle size. For water droplets, good agreement is found with King Air FSSP particle probe measurements in the cloud. For ice particles, the LANDSAT radiance observations predict an effective radius of 60 microns versus aircraft observations of about 200 microns. It is suggested that this descrepancy may be explained by uncertainty in the imaginary index of ice and by inadequate measurements of small ice particles by microphysical probes.

Wielicki, Bruce A.↗

The 27-28 October 1986 FIRE IFO cirrus case study - Comparison of radiative transfer theory with observations by satellite and aircraft

Observations of cirrus and altocumulus clouds during the FIRE are compared to theoretical models of cloud radiative properties. Three tests are performed. First, radiances are used to compare the relationship between nadir reflectance ot 0.83 micron and beam emittance at 11.5 microns with that predicted for model calculations using spherical and nonspherical phase functions. Good agreement is found between observations and theory when water droplets dominate. Poor agreement is found when ice particles dominate, especially using spherical-particle phase functions (SPPFs). Even when compared to a laboratory-measured ice-particle phase function (IPPF), the observations show great side-scattered radiation than the theoretical calculations. Second, the anisotropy of conservatively scattered radiation is examined using simultaneous multiple angle views of the cirrus from Landsat and ER-2 aircraft radiometers. Observed anisotropy gives good agreement with theoretical calculations using the laboratory IPPF and poor agreement with an SPPF. Third, Landsat radiances at 0.83, 1.65, and 2.21 microns are used to infer particle phase and size. For water droplets, good agreement is found with particle-probe measurements in the cloud. For ice particles, the Landsat radiance observations predict an effective radius of 60 microns versus aircraft observations of about 200 microns. It is suggested that this discrepancy may be explained by uncertainty in the imaginary index of ice and by inadequate measurements of small ice particles by microphysical probes.

Wielicki, Bruce A.↗

Aerospace Human Factors

The following contains the final report on the activities related to the Cooperative Agreement between the human factors research group at NASA Ames Research Center and the Psychology Department at San Jose State University. The participating NASA Ames division has been, as the organization has changed, the Aerospace Human Factors Research Division (ASHFRD and Code FL), the Flight Management and Human Factors Research Division (Code AF), and the Human Factors Research and Technology Division (Code IH). The inclusive dates for the report are November 1, 1984 to January 31, 1999. Throughout the years, approximately 170 persons worked on the cooperative agreements in one capacity or another. The Cooperative Agreement provided for research personnel to collaborate with senior scientists in ongoing NASA ARC research. Finally, many post-MA/MS and post-doctoral personnel contributed to the projects. It is worth noting that 10 former cooperative agreement personnel were hired into civil service positions directly from the agreements.

Jordan, Kevin↗

Mission Study and Optics Development Support for Constellation X

This document is the Final Report for NASA Cooperative Agreement NCC5-268 between NASA Goddard Space Flight Center (GSFC) and the Smithsonian Astrophysical Observatory (SAO). The Agreement is entitled "Constellation X-ray Mission Study and Optics Development." The report is required by the terms of the Agreement. There were four modifications to the Agreement. The period of performance was from February 1, 1998 through March 31, 1999. The report summarizes the main areas of SAO activity. Other than the design and analysis related to the SXT Mirror (see Section 4.0), most of the work was carried out jointly with personnel from GSFC and Marshall Space Flight Center (MSFC). Consequently, we do not mean to imply that such activities were carried out exclusively by SAO. Rather, we have tried to describe the SAO participation in these efforts.The report summarizes the main areas of SAO activity. Other than the design and analysis related to the SXT Mirror (see Section 4.0), most of the work was carried out jointly with personnel from GSFC and Marshall Space Flight Center (MSFC). Consequently, we do not mean to imply that such activities were carried out exclusively by SAO. Rather, we have tried to describe the SAO participation in these efforts. As is appropriate to a Cooperative Agreement, SAO worked with GSFC in an integrated team mode. SAO was involved in the mission management, technology development, and mission definition. The organization is shown in Figure 1. While overall management responsibility resided with GSFC, scientific lead and subordinate responsibilities were shared between GSFC and SAO.

Tananbaum, H.↗

Constellation X-Ray Mission and Support

This Fourth Annual Report summarizes work performed by the Smithsonian Astrophysical Observatory (SAO) for NASA Goddard Space Flight Center (GSFC) under Cooperative Agreement NCC5-368. The Agreement is entitled Constellation X-ray Mission Study and SAO continues to perform work under the overall direction of Dr. Harvey Tananbaum, the SAO Principal Investigator for the program. Mr. Robert Rasche is the SAO Program Manager and is responsible for day-to-day program management at SAO and coordination with GSFC. The report summarizes the main areas of SAO activity. Most of the work has been done jointly with personnel from GSFC and Marshall Space Flight Center (MSFC). We describe SAO participation in these efforts. As is appropriate to a Cooperative Agreement, SAO continued to work with GSFC in an integrated team mode. SAO was involved in the overall mission management, technology development, scientific direction, and mission definition. While formal overall management responsibility resides with GSFC, scientific lead and subordinate responsibilities continue to be shared by GSFC and SAO. The work performed by SAO is consistent with the SAO proposal 'Constellation X-ray Mission Study and Optics Development' dated September 1997, which was the basis for establishing the Cooperative Agreement under which SAO is currently funded. Over time, the scope of the effort has expanded somewhat to accommodate the needs of the project. Work, except for meeting support and high priority program tasks, has been at a level of effort. Priorities and work progress have been closely coordinated with the Constellation-X Project Formulation Manager at GSFC. Funding limitations constrained the work accomplished during this period. Nonetheless, a significant amount of work was accomplished. Under the Agreement, SAO performed work in seven major areas of activity. These areas related to: Constellation X-ray Mission Facility Definition Team and Study Management; Science Support; Spectroscopy X-ray Telescope (SXT); Systems Engineering; Travel in Support of the Work Effort; In-house Management and Coordination.

Grady, Jean↗