Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “active distribution systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Job Scheduler-Driven Power Gateway for High Performance Computing

Power gateways in the form of a microgrid can incorporate multiple distributed energy resources (DER) in either grid forming or grid following mode and support high performance computing (HPC) power profiles including the large load-follow requirements observed in multi-user HPC systems. The microgrid’s flexibility to operate in either grid forming or grid following mode and to actively switch between these modes enables baseline power from multiple non-baseline DER while maintaining high power quality metrics for the HPC system. But this enormous flexibility in demand response and time of use shifting is generally programmed independently of any integration with an HPC job scheduler which can better inform the load shaping by the microgrid. While there are many existing approaches where the HPC job scheduler takes in information from the grid to make queue scheduling decisions, this work takes the opposite view and explores a scheduler where the jobs in the queue can directly impact the settings of the grid. Several HPC scheduler strategies are tested where the jobs in the queue directly impact the settings of a microgrid designed for HPC operation which is driving a datacenter with three classes of HPC architectures. The scheduler operation is shown using a microgrid with 64 kW of solar capacity and 320 kWh of battery over a period of 21 days operating with significant low-follow swings, a throttled grid, cloudy conditions, switching between grid following and grid forming modes, and a wide range of battery states-of-charge all while maintaining high quality power metrics. The scheduler provides a mechanism for the job queue to directly impact a power gateway like a microgrid and to improve HPC power outcomes such as maximizing renewable energy usage

microgrid↗

Cyber Resilient Flexible Alternating Current Transmission Systems (XFACTS)

This report summarizes the activities conducted under the DOE-OE funded project DEOE0000897, Cyber Attack Resilient Flexible AC Systems – XFACTS. Hitachi Energy (HE), in collaboration with ABB Inc. (ABB), Bonneville Power Administration (BPA), University of Illinois at Urbana-Champaign (UIUC), Iowa State University (ISU), and University of Idaho (UI) pursued the development of a system of defense for Flexible Alternating current Transmission Systems against cyber-attacks (XFACTS). A FACTS substation enhanced with XFACTS defense mechanisms will be capable of mitigating cyberattacks especially those that seek to control electrical parameters like voltage or current and interrupt the power flow in AC lines. It empowers existing FACTS controllers and associated intelligent electronic devices to detect and mitigate malicious intents to depress system voltages, destabilize power flows, trip AC circuit breakers, corrupt currents, and voltages, even if the malicious commands and the measurements have correct syntax. The XFACTS functions utilize the physics of active power electronic systems, control and protection, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected FACTS substation devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wireless Instrumented RB Experiment Preliminary Design and Analysis

The ability to deploy new nuclear fuels for current or future reactor concepts requires carefully designed experiments to generate data to support fuel qualification. Ideally these experiments would include state of-the-art sensing to maximize the amount of in situ data that can be collected during operation. Furthermore, advanced reactor systems can take advantage of integrated in-core sensing technologies to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator’s understanding of limiting peaking factors. Before any novel sensing technologies can be readily adopted for nuclear applications, they must first demonstrate acceptable performance in test reactors. This report summarizes the preliminary design and analysis of the most highly instrumented irradiation experiment ever performed in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The Wireless Instrumented RB Experiment 2021 (WIRE-21) will test a wide range of sensors including wireless sensors being developed by Westinghouse Electric Company (WEC) that could provide in situ measurements of peak fuel temperatures and fuel rod pressurization due to fission gas release. The ability to wirelessly transmit a signal through the fuel rod’s cladding is critical to improving fuel monitoring capabilities without requiring signal penetrations through the cladding pressure boundary, which would significantly impact fuel fabrication, handling, and operation. Other sensors that will be tested in WIRE-21 include an array of thermocouples, self-powered neutron detectors (SPNDs), and spatially distributed fiber-optic temperature sensors. More generally, WIRE-21 will establish a flexible irradiation vehicle design to allow accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. This report summarizes the mechanical design for WIRE-21, the experimental test matrix, initial neutronic and thermal design analyses, and the active monitoring and control system enhancements necessary to support testing of advanced sensor technologies. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) relevant to light water reactors (LWRs), but the flexible design of the experiment vehicle allows much higher operating temperatures (>1,100°C). Neutronic calculations determine the neutron flux conditions as well as the nuclear heating within the experiments. These results are used as inputs to detailed thermal finite element calculations, which are required to evaluate the complex, three-dimensional heat transfer that occurs within WEC’s wireless sensor enclosures. Initial results show that the temperatures of the sensors’ enclosures and the metal bellows can be operated near the temperature range of LWR coolants and cladding while simultaneously increasing the temperature of a surrogate fuel material to values in the range of 800–1200°C to simulate centerline fuel temperatures during LWR operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydrogen Adsorption, Reactivity, and Catalysis on Colloidal Iron Carbide Nanoparticles

Supported iron carbide particles have long served as catalysts for CO hydrogenation (the Fischer Tropsch synthesis, FTS) and continue to be attractive. Despite this, little is known about their chemistry. Reported here is a colloidal Fe x C nanoparticle (NP) model system that allows direct observation of surface hydrogen and CO, as well as quantification of the surface H. Dodecylamine-capped Fe x C NPs (DDA-Fe x C NPs) were synthesized through solution-phase carburization of Fe NPs and form stable colloids in low-polarity organic solvents. Treatment of these colloids with H 2 or D 2 produced highly hydrogenated materials, and FTIR spectra of DDA-Fe x C-D n showed that most of the D binds to carbides, with at least four distinct v(C-D) modes. The surface C-H(D) bonds were all reactive, transferring hydrogen to alkenes and other reagents in solution. Titration and ICP measurements showed a 0.17:1 ratio of added H:total Fe, or roughly. 40 H per 1.8 nm DDA-Fe x C NP. Conversely, CO was preferentially bound to surface Fe sites, with FTIR spectra showing a single broad v(CO) that shifted with CO coverage or co-adsorption of H 2 . The DDA-Fe x C NPs were active catalysts for both olefin hydrogenation and the FTS, under mild conditions and without catalyst pre-treatment. The CO hydrogenation reactions yielded a broad distribution of long-chain linear paraffins and olefins. Though quantitative comparisons with typical FTS results are not possible because of our use of sealed batch reactors and other factors, the observations of high catalytic reactivity demonstrate the relevance of this model system to iron-carbide catalysis. DFT calculations on model slab surfaces with varying iron carbide stoichiometries revealed that the thermodynamically preferred surface adsorption sites are C for H ads and Fe for CO ads . A variety of binding sites and binding energies were found for each adsorbate. We are unaware of previous studies indicating that a diverse array of C-H bonds is the primary source of reactive H on iron carbides. Experimentally, the diversity of *C-H sites was evident in reactions with H-atom donors and abstractors of different strengths, from both the reaction stoichiometries and IR spectra. The different surface–H binding energies correlate with the v(C-D) stretching frequencies. Furthermore, these insights into complex iron carbide surfaces and catalysis could assist catalyst design, and they showcase the importance of stoichiometric studies of reaction intermediates.

08 HYDROGEN↗

Modeling and Analysis of DC Microgrids as Stochastic Hybrid Systems

This study proposes a method of predicting the influence of random load behavior on the dynamics of dc microgrids and distribution systems. This is accomplished by combining stochastic load models and deterministic microgrid models. Together, these elements constitute a stochastic hybrid system. The resulting model enables straightforward calculation of dynamic state moments, which are used to assess the probability of desirable operating conditions. Specific consideration is given to systems based on the dual active bridge (DAB) topology. Bounds are derived for the probability of zero voltage switching (ZVS) in DAB converters. A simple example is presented to demonstrate how these bounds may be used to improve ZVS performance as an optimization problem. In conclusion, predictions of state moment dynamics and ZVS probability assessments are verified through comparisons to Monte Carlo simulations.

42 ENGINEERING↗

Synthetic Ancillary Service Generator (SynAS) v1

The balance of demand and supply in the electric power grid is a crucial element to grid reliability. While balancing is typically provided by conventional power plants, with spinning generators, distributed energy resources (DER) and especially electric vehicles (EVs) pose a great potential to provide such service. This project conducted a field demonstration at the Los Angeles Air Force Base (LA-AFB) where a fleet of mixed-use bi-directional EVs were actively participating in the California Independent System Operator (CAISO) market for frequency regulation. While participation in regulation markets is promising, a major drawback in designing control systems and assessing potential revenue is the lack of example frequency regulation signals. This project introduces an open-source dataset for 143 days of four-second regulation data, and the SynAS Python module to synthetically generate frequency regulation signals of arbitrary length.

Black, DouglasR↗

Time-domain Modulation of HD 189733 Activities by Its Planet

Star–planet interaction can be studied by analyzing exoplanetary orbit and stellar rotation modulations of the transit emissions from exoplanetary systems. Here we carry out a time-domain analysis of the multiband activities of the HD 189733 star–planet system observed in X-ray, atomic lines, and broadband spectra reported in the literature. We find that the number of activities occuring at beat angles (of the planetary orbit and the stellar rotation) concentrating on a sector with a width of 108° are significantly larger than expected from a uniform distribution of activities, which indicates the existence of a major stellar active magnetic field region. The concentration of activities in this active magnetic field region shows their possible origins from the magnetic field interaction between HD 189733 and its close planet HD 189733 b.

47 OTHER INSTRUMENTATION↗

A Conceptual Framework to Describe Energy Efficiency and Demand Response Interactions

Energy efficiency (EE) and demand response (DR) resources provide important utility system and ratepayer benefits. At the same time, the rapid change in the amount and type of variable renewable energy, like solar and wind, is reshaping the role and economic value of EE and DR, and will likely affect time-dependent valuation of EE and DR measures. Utilities are increasingly interested in integrating EE and DR measures and technologies (as well as other distributed energy resources) as a strategic approach to improve their collective cost-effectiveness and performance. However, the specific EE and DR features that may be best integrated, the interplay between changing EE and DR resource potential, and the resulting utility system impacts, are not well understood. We develop a framework to identify the EE and DR attributes, system conditions, and technological factors that are likely to drive interactions between EE and DR. We apply the framework to example measures with different technology specifics (e.g., presence of controls, building type, and targeted end use) in the context of different system conditions (e.g., peak demand, load-building periods during high renewable generation output). Ultimately, the framework defines EE and DR interactions not only by the change in discretionary load (i.e., DR potential) but also by the change in likelihood of participation in EE and DR programs—as well as the change in system need for, and the overall availability of, EE and DR resources. The framework is intended to improve the integration of EE and DR in utility operational and planning activities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct root contact among neighboring plants influences activity of soil extracellular enzymes

Composition and diversity of vegetation systems can influence soil microbial activity and extracellular enzyme (EE) dynamics, which are crucial for soil carbon (C) accrual and nutrient cycling. Yet, the impact of plant interactions and competition on EE activities remains a notable knowledge gap. This study examines how direct root contact and neighboring plant identity affect the activity and spatial distribution of four key soil EEs: β-glucosidase (BGlu), chitinase, acid phosphatase (AcidP), and alkaline phosphatase (AlkP). Using three-compartment rhizoboxes with switchgrass (Panicum virgatum L.) grown alongside bush clover (Lespedeza capitata Michx.), and black-eyed Susan (Rudbeckia hirta L.), we assessed enzyme activities using zymography under conditions that either allowed or restricted direct root contact by root barriers. Results show that root proliferation and species interactions significantly influenced EE activity. While BGlu and AcidP activities were strongly correlated with root biomass, AlkP activity was consistently higher in the absence of root barriers, indicating a pronounced microbial response to plant interactions via direct/close root contacts. Additionally, soil phosphorus availability modulated enzyme activity, with higher phosphatase activities in low-P soils. Furthermore, these findings highlight the importance of root-root interactions and plant species composition in shaping soil biochemical processes.

enyzme activity↗

A Robust Hierarchical Dispatch Scheme for Active Distribution Networks Considering Home Thermal Flexibility

Distribution networks are changing from passive absorbers of electric energy to active distribution networks (ADNs) capable of operating and participating in electricity markets. In the context of residential microgrids, which is a type of ADNs, aggregated home heating, ventilation and air-conditioning (HVAC) loads present a key opportunity to drive operational and economic objectives, facilitate high renewable energy penetration, and enhance both system resiliency and flexibility. A robust, hierarchical dispatch scheme is developed and presented in this paper, which connects an upper level multi-phase distribution optimal power flow (DOPF) to a lower level model predictive control (MPC)-based HVAC fleet controller. The approach is tested and verified on a modified IEEE 13 bus system in an intraday market application. The results demonstrate that the proposed hierarchical dispatch scheme is able to drive both economic and operational objectives for the ADN operator.

Rooks, Cody D.↗

Large-scale Hydrogen Storage – Risk Assessment Seattle City Light and Port of Seattle [Abstract]

This CRADA presents the strategy that Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL) will take to support Seattle City Light (SCL), and the Port of Seattle (Port) in performing a risk assessment of large-scale hydrogen storage. Risk assessment is often used to ensure that adequate measures are taken to protect workers and the public, the environment, infrastructure, and assets. A detailed risk assessment can also be used to direct funding and upgrades, to specific components and sub-systems in order to mitigate risks to the larger system. In this way risk assessments are often employed as a part of a larger risk management strategy, with the goal of minimizing the occurrence of hazards and to identify means to limit their consequences. Risk assessment is often used to engage and inform regulators, and to communicate how specific regulations are being met. However, it is important to note that the proposed work is not intended for SCL and the Port to use in order to gain regulatory acceptance for their proposed activities. The work performed as a part of this effort will be a preliminary risk assessment for early-stage component and system designs and should be considered research and development (R&D). As such, the proposed work will be performed to a quality level and design maturity consistent with R&D and is not considered appropriate for final safety analysis and regulatory compliance purposes. Previous and on-going work at SCL and the Port demonstrated the utility of deploying hydrogen systems at the Port. The deployment of hydrogen at the Port is a part of a larger vision of using hydrogen to address a range of issues for SCL and the Port. These include large-scale fueling of MD/HD vehicles, cargo-handling equipment (CHE), and harbor vessels to reduce emissions; support of adjacent LD vehicles; support of critical port operations during extreme events (i.e., resiliency); deferral of more capital- and time-intensive electrical distribution system upgrades while still supporting evolving port operations and decarbonization efforts; facilitating electrification by establishing energy storage as a grid resource, starting at strategic port locations; creation of a flexible market resource that can be used by SCL to generate revenue via arbitrage; support of planned future maritime operations that involve heavy use of hydrogen for ocean-going vessels; and future end-use applications involving natural gas pipeline hydrogen injection. Ultimately, the success of these activities is underpinned by the deployed storage capacity. Large-scale deployment of hydrogen systems will require hydrogen storage at a scale that has not been demonstrated. In addition, the ideal location for such multi-use systems is near the end user which will often necessitate deploying into urban and/or industrial areas. A detailed risk assessment using the Port as a test case is necessary to ensure the deployment of large-scale hydrogen is successful. Many technologies have been proposed for hydrogen storage; however, these technologies need to be analyzed as they apply to an actual site. The physical infrastructure and hydrogen use cases for the Port will be analyzed, and a risk assessment for compressed hydrogen, liquified hydrogen, and Liquid Organic Hydrogen Carrier (LOHC) storage will be performed. These risk assessments will be useful for understanding how each of these technologies would perform in terms of facility and public safety. The operating states of the proposed hydrogen systems at the Port will be analyzed and incorporated into the storage risk assessment. Scalability will also be analyzed to understand how future port uses would affect the overall risk assessment. Finally, using the risk assessment as a tool to inform engagement and to gain stakeholder acceptance will be explored.

08 HYDROGEN↗

Redistribution of radionuclides in irradiated AGR-1 UCO TRISO fuel after 1800 °C safety testing

Release of radionuclides from intact tristructural-isotropic (TRISO) coated particle fuel at normal and accident conditions is a primary metric of fuel performance. The distribution of fission products and actinides in the TRISO layers of individual particles provides insight on radionuclide transport and release behavior and was determined using scanning electron microscopy analysis. Particles were isolated from an irradiated fuel compact (AGR-1 Compact 4-4-2) and analyzed as-irradiated or after individual particle safety-testing at 1800 °C for 650 h. Particles were selected for comparison based on their remaining 110mAg fission product inventory. These comparisons corroborated the observation that the 110m Ag inventory is a marker for relative irradiation temperature based on observed radionuclide distribution in the SiC layer. The comparison also indicated that the in-pile behavior influences the fission product and actinide species interactions with the TRISO layers during high temperature exposure after irradiation. The analysis confirms both palladium and uranium diffusion, as well as other species, are active in the UCO TRISO fuel system at 1800 °C and that palladium transport is active at lower temperatures relative to uranium. While diffusion across the SiC layer was observed, the intact nature of the SiC layer after the 1800 °C, 650-h exposure indicates the SiC layer maintained its functionality as a fission product barrier by mitigating release of radionuclides at beyond accident margin temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Distributed Machine Learning Workflow with PanDA and iDDS in LHC ATLAS

Machine Learning (ML) has become one of the important tools for High Energy Physics analysis. As the size of the dataset increases at the Large Hadron Collider (LHC), and at the same time the search spaces become bigger and bigger in order to exploit the physics potentials, more and more computing resources are required for processing these ML tasks. In addition, complex advanced ML workflows are developed in which one task may depend on the results of previous tasks. How to make use of vast distributed CPUs/GPUs in WLCG for these big complex ML tasks has become a popular research area. In this paper, we present our efforts enabling the execution of distributed ML workflows on the Production and Distributed Analysis (PanDA) system and intelligent Data Delivery Service (iDDS). First, we describe how PanDA and iDDS deal with large-scale ML workflows, including the implementation to process workloads on diverse and geographically distributed computing resources. Next, we report real-world use cases, such as HyperParameter Optimization, Monte Carlo Toy confidence limits calculation, and Active Learning. Finally, we conclude with future plans.

97 MATHEMATICS AND COMPUTING↗

Design Considerations for Distributed Energy Resource Honeypots and Canaries

There are now over 2.5 million Distributed Energy Resource (DER) installations connected to the U.S. power system. These installations represent a major portion of American electricity critical infrastructure and a cyberattack on these assets in aggregate would significantly affect grid operations. Virtualized Operational Technology (OT) equipment has been shown to provide practitioners with situational awareness and better understanding of adversary tactics, techniques, and procedures (TTPs). Deploying synthetic DER devices as honeypots and canaries would open new avenues of operational defense, threat intelligence gathering, and empower DER owners and operators with new cyber-defense mechanisms against the growing intensity and sophistication of cyberattacks on OT systems. Well-designed DER canary field deployments would deceive adversaries and provide early-warning notifications of adversary presence and malicious activities on OT networks. In this report, we present progress to design a high-fidelity DER honeypot/canary prototype in a late-start Laboratory Directed Research and Development (LDRD) project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interseismic Strain Accumulation between the Colorado Plateau and the Eastern California Shear Zone: Implications for the Seismic Hazard near Las Vegas, Nevada

ABSTRACT Crustal deformation in the central Basin and Range between the Colorado plateau and the Eastern California Shear Zone is active but slow, making it a challenge to assess how strain is distributed and crustal motion transferred. However, knowledge of strain rates is very important, particularly for addressing the seismic hazard for both the Las Vegas urban area and the site of the proposed Yucca Mountain nuclear waste repository, in southern Nevada. Global Positioning System (GPS) data provide important constraints, particularly now that the GPS network in the area has substantially expanded in recent years. However, because deformation is slow, it is important to mitigate any transient tectonic and nontectonic signals to obtain the most accurate long-term interseismic motion and robust estimation of strain rates. We use data from all GPS stations in the region including both long-running continuous and semicontinuous stations. We model and remove postseismic displacements at these stations using source parameters for 41 events, dating back to the 1700 Cascadia megathrust earthquake, which contribute significantly to the deformation field within the central Basin and Range. We also remove correlated noise from the time series with the common-mode component imaging technique. We find that removal of both the postseismic transients and common-mode noise substantially reduces the uncertainties and spatial variation in the velocities. We find east–west extension across the Las Vegas Valley of 0.5–0.6 mm/yr. The interseismic strain rate field, calculated with the final velocities, reveals higher strain rates through southern Nevada than in previous studies, with rates within Las Vegas Valley of 8.5±2.4×10−9 yr−1. Our results also confirm shear along the Pahranagat shear zone, but the estimated amplitude is strongly affected by postseismic relaxation.

Geochemistry & Geophysics↗

Trust Model Utilization for Energy Grid Communication

The internet information that is used by the Energy Grid of Things requires both preventative security measures as well as surveillance measures. The preventative security measures include certificates, encryption, and all of the basic security protocols as defined by published standards. The surveillance measures include monitoring information flow activities and evaluating these messages for indications of potential security attacks. We describe in this paper the utilization of a Distributed Trust Model that was developed specifically for monitoring communication within an Energy Grid of Things. The goal for the Distributed Trust Models is to provide a level of aggregate trust that a Distributed Energy Resource Management System can meet its grid service obligations, as opposed to a detailed individual Distributed Energy Resources assessment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Cyber Supply Chain Incidents with Multilayered Graph Motifs

As noted within the literature, supply chain includes people and organizations---manufacturers, integrators, and third-party vendors---that are involved in one or more stages of a product lifecycle. Since supply chains, by definition, include organizations and people, supply chain risk management activities must consider dependencies between an organization's business processes and third-party resources. Just as adversarial tactics can be implemented via techniques implemented via networked computer systems, so can such tactics be expressed via legal business relationships. A cyber incident may have an exponential impact downstream, for example, by leveraging a product's distribution channel (e.g. malicious updates in SolarWinds, buggy updates in CrowdStrike). Similarly, legitimate and legal business relationships also affect the attack surface exposure of systems, enabling long-term persistence and/or unknown impacts to product quality that are hard to detect. This paper catalogs several recent digital supply chain incidents and applies a multilayered network formalism to develop structural indicators (graph motifs) that reflect potentially-adversarial behavior. Finally, we compare and contrast the characteristics of adversarial tactics (e.g. Loss of Availability, Data Collection) that leverage cyber-physical dependencies to those that leverage legal organizational relationships.

97 - MATHEMATICS AND COMPUTING↗

An Uncertainty Management Framework for Integrated Gas-Electric Energy Systems

In many parts of the world, electric power systems have seen a significant shift toward generation from renewable energy and natural gas. Because of their ability to flexibly adjust power generation in real time, gas-fired power plants are frequently seen as the perfect partner for variable renewable generation. However, this reliance on gas generation increases interdependence and propagates uncertainty between power grids and gas pipelines and brings coordination and uncertainty management challenges. To address these issues, we propose an uncertainty management framework for uncertain, but bounded gas consumption by gas-fired power plants. The admissible ranges are computed based on a joint optimization problem for the combined gas and electricity networks, which involves chance-constrained scheduling for the electric grid and a novel robust optimization formulation for the natural-gas network. This formulation ensures feasibility of the integrated system with a high probability, while providing a tractable numerical formulation. A key advance with respect to existing methods is that our method is based on a physically accurate, validated model for transient gas pipeline flows. Our case study benchmarks our proposed formulation against methods that ignore how reserve activation impacts the fuel use of gas power plants and only consider predetermined gas consumption. Here, the results demonstrate the importance of considering uncertainty to avoid operating constraint violations and curtailment of gas to the generators.

24 POWER TRANSMISSION AND DISTRIBUTION↗