Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A real time, low cost, data acquisition telecommunication network

The real time, low cost data acquisition communication network described features the use of asynchronous ASCII code transmissions operating at 30 characters per second on the dial-up telephone system. The network features an elaborate, but easily generated error checking system, operating in a line-by-line demand-response mode. The system is readily adaptable for any low speed computer-to-computer data transmissions requiring high reliability in data transmission. The network was developed for the acquisition of prelaunch wind data from the Eastern Test Range at Cape Kennedy.

Schulte, R. R.↗

Instrumentation and data acquisition systems

A comprehensive and integrated measurement system was identified and a design and development effort initiated to meet the criteria imposed by the National Transonic Facility operating environment. Specific measurement areas receiving concentrated attention include: data acquisition, force measurement, pressure instrumentation, flow visualization techniques, model attitude and model deformation measurement, and temperature measurement. The NTF instrument complex will be centered around four 32-bit, 1-microsecond-cycle-time central processing units connected in a multipoint-distributed network configuration. The principal activities to be supported by these computers are: (1) data base management and processing; (2) research measurement data acquisition and display; (3) tunnel and model control; and (4) process monitoring and communication control. The distributed network approach was chosen to modularize the functional software into definable and implementable parts by the various groups involved in the design and to permit use of similar hardware configurations to improve reliability and maintainability.

Guarino, J. F.↗

A high-voltage-isolated automated data acquisition system

A data acquisition system for electric-arc heated, high-temperature wind tunnel facilities has been developed; the high voltage isolation of the system exceeds 50 kV. A closed loop, optically coupled data system acquires transducer signals from high-temperature, arc-generated plasmas used for reentry testing. The data acquisition system monitors on-line tests, stores data on magnetic tape, and prints out a paper tape. The system has 400 data channels: 200 low-voltage programmable channels and 200 high-voltage sequential channels.

Cox, J.↗

Use of a priori statistics to minimize acquisition time for RFI immune spread spectrum systems

The optimum acquisition sweep strategy was determined for a PN code despreader when the a priori probability density function was not uniform. A psuedo noise spread spectrum system was considered which could be utilized in the DSN to combat radio frequency interference. In a sample case, when the a priori probability density function was Gaussian, the acquisition time was reduced by about 41% compared to a uniform sweep approach.

Holmes, J. K.↗

Escort - A data acquisition and display system to support research testing

A combination of a central minicomputer and test-site microcomputers has been adopted to provide on-line data acquisition and display service for a large number of different research programs. By integrating the data acquisition and recording functions in the minicomputer/microcomputer system, rapidly updated displays of selected data in terms of engineering units may be obtained. The system described here is primarily designed for steady-state test conditions, but may also provide data on slow transients associated with changing experimental conditions. Application of the system to full-scale jet engine tests, ion thruster assessments and anechoic chamber analyses are mentioned.

Miller, R. L.↗

Effect of vibration on retention characteristics of screen acquisition systems

The design of surface tension propellant acquisition systems using fine-mesh screen must take into account all factors that influence the liquid pressure differentials within the system. One of those factors is spacecraft vibration. Analytical models to predict the effects of vibration have been developed. A test program to verify the analytical models and to allow a comparative evaluation of the parameters influencing the response to vibration was performed. Screen specimens were tested under conditions simulating the operation of an acquisition system, considering the effects of such parameters as screen orientation and configuration, screen support method, screen mesh, liquid flow and liquid properties. An analytical model, based on empirical coefficients, was most successful in predicting the effects of vibration.

Tegart, J. R.↗

Analytical models and system topologies for remote multispectral data acquisition and classification

Simple analytical models are presented of the radiometric and statistical processes that are involved in multispectral data acquisition and classification. Also presented are basic system topologies which combine remote sensing with data classification. These models and topologies offer a preliminary but systematic step towards the use of computer simulations to analyze remote multispectral data acquisition and classification systems.

Huck, F. O.↗

Improvements and modifications to the NASA microwave signature acquisition system

A user oriented description of the modified and upgraded Microwave Signature Acquisition System is provided. The present configuration of the sensor system and its operating characteristics are documented and a step-by-step operating procedure provides instruction for mounting the antenna truss assembly, readying the system for data acquisition, and for controlling the system during the data collection sequence. The resulting data products are also identified.

Jean, B. R.↗

Turbojet blade vibration data acquisition design and feasibility testing

A turbojet blade vibration data acquisition system was designed to allow the measurement of blade vibration. The data acquisition system utilizing 96 microprocessors to gather data from optical probes, store, sort and transmit to the central computer is described. Areas of high technical risk were identified and a two-microprocessor system was breadboarded and tested to investigate these areas. Results show that the system was feasible and that low technical risk would be involved in proceeding with the complete system fabrication.

Frarey, J. L.↗

The acquisition, storage, and dissemination of LANDSAT and other LACIE support data

Activities performed at the LACIE physical data library are described. These include the researching, acquisition, indexing, maintenance, distribution, tracking, and control of LACIE operational data and documents. Much of the data available can be incorporated into an Earth resources data base. Elements of the data collection that can support future remote sensing programs include: (1) the LANDSAT full-frame image files; (2) the microfilm file of aerial and space photographic and multispectral maps and charts that encompasses a large portion of the Earth's surface; (3) the map/chart collection that includes various scale maps and charts for a good portion of the U.S. and the LACIE area in foreign countries; (4) computer-compatible tapes of good quality LANDSAT scenes; (5) basic remote sensing data, project data, reference material, and associated publications; (6) visual aids to support presentation on remote sensing projects; and (7) research acquisition and handling procedures for managing data.

Abbotts, L. F.↗

Cardiopulmonary data acquisition system. Version 2.0, volume 1: User's guide

The Cardiopulmonary Data Acquisition System is a computerized method of both collecting and analyzing physiological data on subjects during a treadmill or ergometer stress test in the clinic. The real time acquisition of the physiological data, such as, heart rate, blood pressure, work load, and respiratory gases is accomplished by an LSI-11 microcomputer which displays this data on a hard copy terminal. The data are also concurrently stored on a mass storage device and anytime after the test period a selectable number of copies of the plots or minute reports can be reproduced at the terminal.

Source record↗

Mars sample return: Site selection and sample acquisition study

Various vehicle and mission options were investigated for the continued exploration of Mars; the cost of a minimum sample return mission was estimated; options and concepts were synthesized into program possibilities; and recommendations for the next Mars mission were made to the Planetary Program office. Specific sites and all relevant spacecraft and ground-based data were studied in order to determine: (1) the adequacy of presently available data for identifying landing sities for a sample return mission that would assure the acquisition of material from the most important geologic provinces of Mars; (2) the degree of surface mobility required to assure sample acquisition for these sites; (3) techniques to be used in the selection and drilling of rock a samples; and (4) the degree of mobility required at the two Viking sites to acquire these samples.

Nickle, N.↗

Development of a simple, self-contained flight test data acquisition system

A low cost flight test data acquisition system, applicable to general aviation airplanes, was developed which meets criteria for doing longitudinal and lateral stability analysis. Th package consists of (1) a microprocessor controller and data acquisition module; (2) a transducer module; and (3) a power supply module. The system is easy to install and occupies space in the cabin or baggage compartment of the airplane. All transducers are contained in these modules except the total pressure tube, static pressure air temperature transducer, and control position transducers. The NASA-developed MMLE program was placed on a microcomputer on which all data reduction is done. The flight testing program undertaken proved both the flight testing hardware and the data reduction method to be applicable to the current field of general aviation airplanes.

Renz, R. R. L.↗

Discriminator aided phase lock acquisition for suppressed carrier signals

A discriminator aided technique for acquisition of phase lock to a suppressed carrier signal utilizes a Costas loop which is initially operated open loop and control voltage for its VCXO is derived from a phase detector that compares the VCXO to a reference frequency thus establishing coarse frequency resolution with the received signal. Then the Costas loop is closed with the low-pass filter of the channel having a bandwidth much greater (by a factor of about 10) than in the I channel so that a frequency discriminator effect results to aid carrier resolution. Finally, after carrier acquisition, the Q-channel filter of the Costas loop is switched to a bandwidth substantially equal to that of the I-channel for carrier tracking.

Carson, L. M.↗

NASA tracking and data acquisition in the 1990s - High earth orbit and planetary spacecraft support

It is pointed out that during the decade of the 1980's the Deep Space Network (DSN) and the ground stations of the Ground Spaceflight Tracking Data Network (GSTDN) will have been consolidated into one ground-based network to provide services for tracking and data acquisition for NASA deep space probes and highly elliptical earth orbiters. The Tracking and Data Relay Satellite System (TDRSS) will have been implemented to handle low earth orbiters. Anticipated solar system exploration missions of the 1990's are discussed, and a description is presented of the new tracking and data acquisition requirements for supporting these missions. The technology options needed to meet these new requirements are identified, and the impact of these technology options on the consolidated DSN is discussed. Attention is given to the evolution of the DSN of the 1980's into the DSN of the year 2000.

Smith, J. G.↗

NASA tracking and data acquisition in the 1990's - Support for low earth orbit missions

Requirements related to increases in data volume for missions projected for the 1990's could be met by increasing the number of satellites in the Tracking and Data Relay Satellite System (TDRSS) constellation or by providing a new tracking and data acquisition satellite system having greater capacity (gigabits), increased reliability, and more direct user-to-relay connectivity. The program to develop the heir to TDRSS for the 1990's, has been defined as Tracking and Data Acquisition System (TDAS). A description is presented of the system architectural considerations which have to be studied in order to develop a cost effective TDAS. Attention is given to basic TDAS design parameters, TDAS spacecraft architectures, system considerations, technology considerations, and TDAS constellation options involving 2, 3, and 4 satellites.

Schwartz, J. J.↗

Development of a simple, self-contained flight test data acquisition system

The system concepts and the flight test program results for a NASA designed in-flight data acquisition system are described. The system draws power from a rechargeable battery pack and intrudes on the aircraft systems only with a total pressure probe, a static pressure probe, and control position transducers, which are simply taped to the frame. A 4000 byte microcomputer forms the heart of the data recording system for cassette tape storage, and is expansion coupled to an eight-bit interactive microcomputer which interfaces with a transducer package for 16-channel demultiplexing. The transducers, ranges, and accuracies are listed, and a five/sec data acquisition rate minimum requirement is noted, although a 10/sec rate is used. The system components are detailed, along with the control and data processing procedures, and the results of dynamic flight testing are presented.

Renz, R. R. L.↗

Performance analysis for the expanding search PN acquisition algorithm

An approach is described for approximating the cumulative probability distribution of the acquisition time of the serial pseudonoise (PN) search algorithm. The results are applicable to both variable and fixed dwell time systems. The theory is developed for the case where some a priori information is available on the PN code epoch (reacquisition problem or acquisition of very long codes). Also considered is the special case of a search over the whole code. The accuracy of the approximation is demonstrated by comparisons with published exact results for the fixed dwell time algorithm.

Braun, W. R.↗