Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume of fluid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Instantaneous stroke volume in man during lower body negative pressure /LBNP/

Results of an examination of the instantaneous time course of the stroke volume (SV) and cardiac output (Q) in response to the onset and release of -50 torr lower body negative pressure (LBNP) are reported. Six male subjects were sealed into a LBNP box up to the iliac crest while being monitored by echocardiograph for centerlamina blood velocity, fluid displacement, stroke volume, heart rate, and leg volume. Particular use was made of pulsed ultrasonic Doppler velocity meters for measuring the blood velocities and flow dynamics. Measurements were made of the subjects continuously beginning from 20 sec prior to and one min after LBNP onset and release. A linear fall in the SV was observed with LBNP at 49% of the baseline value after 33 sec. A 62% drop, the lowest, was detected after 8 min of LBNP. The leg volume was inversely related to Q for the duration of the experiment.

Loeppky, J. A.↗

Biostereometric analysis of body form

Four-camera stereophotogrammetry of Skylab crewmen, preflight and postflight, revealed a loss of volume of one to one and one-half liters from the legs, much of which was replaced during the first 4 postflight days. It is estimated that about one third of the loss represents partial atrophy due to relative disuse in zero-gravity, the remainder being due to a deficit in body fluid. Reduction in volume of the abdomen has also been noted.

Whittle, M. W.↗

Cryogenic Calcite: A Morphologic and Isotopic Analog to the ALH84001 Carbonates

Martian meteorite ALH84001 carbonates preserve large and variable microscale isotopic compositions, which in some way reflect their formation environment. These measurements show large variations (>20%) in the carbon and oxygen isotopic compositions of the carbonates on a 10-20 micron scale that are correlated with chemical composition. However, the utilization of these data sets for interpreting the formation conditions of the carbonates is complex due to lack of suitable terrestrial analogs and the difficulty of modeling under non-equilibrium conditions. Thus, the mechanisms and processes are largely unknown that create and preserve large microscale isotopic variations in carbonate minerals. Experimental tests of the possible environments and mechanisms that lead to large microscale isotopic variations can help address these concerns. One possible mechanism for creating large carbon isotopic variations in carbonates involves the freezing of water. Carbonates precipitate during extensive CO2 degassing that occurs during the freezing process as the fluid s decreasing volume drives CO2 out. This rapid CO2 degassing results in a kinetic isotopic fractionation where the CO2 gas has a much lighter isotopic composition causing an enrichment of 13C in the remaining dissolved bicarbonate. This study seeks to determine the suitability of cryogenically formed carbonates as analogs to ALH84001 carbonates. Specifically, our objective is to determine how accurately models using equilibrium fractionation factors approximate the isotopic compositions of cryogenically precipitated carbonates. This includes determining the accuracy of applying equilibrium fractionation factors during a kinetic process, and determining how isotopic variations in the fluid are preserved in microscale variations in the precipitated carbonates.

Niles, P. B.↗

On the Response of a Herschel–Bulkley Fluid Due to a Moving Plate

In this paper, we study the boundary-layer flow of a Herschel–Bulkley fluid due to a moving plate; this problem has been experimentally investigated by others, where the fluid was assumed to be Carbopol, which has similar properties to cement. The computational fluid dynamics finite volume method from the open-source toolbox/library OpenFOAM is used on structured quad grids to solve the mass and the linear momentum conservation equations using the solver “overInterDyMFoam” customized with non-Newtonian viscosity libraries. The governing equations are solved numerically by using regularization methods in the context of the overset meshing technique. The results indicate that there is a good comparison between the experimental data and the simulations. The boundary layer thicknesses are predicted within the uncertainties of the measurements. The simulations indicate strong sensitivities to the rheological properties of the fluid.

36 MATERIALS SCIENCE↗

Validation of Spectral Analysis as a Noninvasive Tool to Assess Autonomic Regulation of Cardiovascular Function

A major focus of our program has been to develop a sensitive noninvasive procedure to quantify early weightlessness-induced changes in cardiovascular function or potential dysfunction. Forty studies of healthy young volunteers (10 men and 10 women, each studied twice) were conducted to determine changes in the sympatho-vagal balance of autonomic control of cardiovascular regulation during graded headward and footward blood volume shifts. Changes in sympatho-vagal balance were classified by changes in the mean levels and spectral content of cardiovascular variables and verified by changes in circulating levels of catecholamines and pancreatic polypeptide. Possible shifts in intra/extravascular fluid were assessed from changes in hematocrit and plasma mass density while changes in the stimulus to regulate plasma volume were determined from Plasma Renin Activity (PRA). Autonomic blockade was used to unmask the relative contribution of sympathetic and parasympathetic efferent influences in response to 10 min each of 0, 20 and 40 mmHg Lower Body Negative Pressure (LBNP) and 15 and 30 mmHg Positive Pressure (LBPP). The combination of muscarinic blockade with graded LBNP and LBPP was used to evoke graded increases and decreases in sympathetic activity without parasympathetic contributions. The combination of beta blockade with graded LBNP and LBPP was used to produce graded increases and decreases in parasympathetic activity without beta sympathetic contributions. Finally, a combination of both beta and muscarinic blockades with LBNP and LBPP was used to determine the contribution from other, primarily alpha adrenergic, sources. Mean values, spectral analyses and time frequency analysis of R-R interval (HR), Arterial Pressure (AP), peripheral blood flow (RF), Stroke Volume (SV) and peripheral resistance (TPR) were performed for all phases of the study. Skin blood Flow (SF) was also measured in other studies and similarly analyzed. Spectra were examined for changes in three frequency regions (low 0.006 - 0.005 Hz (LF), mid 0.05 - 0.15 Hz (W), and high 0.15 - 0.45 Hz (EF)). The primary objective of the study was to indicate which changes in the mean values and/or spectra of cardiovascular variables consistently correlated with changes in sympatho-vagal balance in response to headward and footward fluid shifts. A secondaey objective was to quantify the vascular and extravascular fluid shifts evoked by LBNP and LBPP. The principal hypothesis being tested was that headward fluid shifts would evoke an increase in parasympathetic activity and footward fluid shifts would evoke an increase in sympathetic activity both of which would be detected by spectral analysis and verified by circulating hormones. Hematocrit (HCT), plasma mass density and plasma renin activity increased with muscarinic blockade and with LBNP, a response indicative of a plasma shift to extravascular spaces. Beta blockade alone or after muscarinic blockade had no effect on HCT or plasma mass density. With respect to intravascular fluid volume distribution, LBNP and LBPP produced sufficient upper body vascular fluid shifts to evoke appropriate autonomic regulatory responses.

Knapp, Charles F.↗

Physiologic adaptation of man in space; Proceedings of the Seventh International Man in Space Symposium, Houston, TX, Feb. 10-13, 1986

Topics discussed in this volume include space motion sickness, cardiovascular adaptation, fluid shifts, extravehicular activity, general physiology, perception, vestibular response modifications, vestibular physiology, and pharmacology. Papers are presented on the clinical characterization and etiology of space motion sickness, ultrasound techniques in space medicine, fluid shifts in weightlessness, Space Shuttle inflight and postflight fluid shifts measured by leg volume changes, and the probability of oxygen toxicity in an 8-psi space suit. Consideration is also given to the metabolic and hormonal status of crewmembers in short-term space flights, adaptive changes in perception of body orientation and mental image rotation in microgravity, the effects of a visual-vestibular stimulus on the vestibulo-ocular reflex, rotation tests in the weightless phase of parabolic flight, and the mechanisms of antimotion sickness drugs.

Holland, Albert W.↗

Cardiovascular Adaptations to Long Duration Head-Down Tilt Bed Rest

INTRODUCTION: Orthostatic hypotension is a serious risk for crewmembers returning from spaceflight. Numerous cardiovascular mechanisms have been proposed to account for this problem, including vascular and cardiac dysfunction, which we studied during bed rest. METHODS: Thirteen subjects were studied before and during bed rest. Statistical analysis was limited to the first 49-60 days of bed rest, and compared to pre-bed rest data. Ultrasound data were collected on vascular and cardiac structure and function. Tilt testing was conducted for 30 minutes or until presyncopal symptoms intervened. RESULTS: Plasma volume was significantly reduced by day 7 of bed rest. Flow-mediated dilation in the leg was significantly increased at bed rest day 49. Arterial responses to nitroglycerin differed in the arm and leg, but did not change as a result of bed rest. Intimal-medial thickness markedly decreased at bed rest days 21, 35 and 49. Several cardiac functional parameters including isovolumic relaxation time, ejection time and myocardial performance index were significantly increased (indicating a decrease in cardiac function) during bed rest. There was a trend for decreased orthostatic tolerance following 60 days of bed rest. DISCUSSION: These data suggest that 6 head-down tilt bed rest alters cardiovascular structure and function in a pattern similar to short duration spaceflight. Additionally, the vascular alterations are primarily seen in the lower body, while vessels of the upper body are unaffected. KEY WORDS: spaceflight, orthostatic intolerance, hypotension, fluid-shift, plasma volume

Platts, Steven H.↗

Heat transfer in directly-irradiated high-temperature solid–gas flows laden with polydisperse particles

Heat transfer in directly-irradiated high-temperature solid–gas flows laden with polydisperse particles is investigated using a novel transient three-dimensional computational fluid dynamics model. The model couples particle–gas hydrodynamics of solid–gas flows laden with polydisperse particles, radiative heat transfer in non-grey absorbing, emitting and anisotropically-scattering multi-component participating media, conduction heat transfer in the gas phase, and interfacial convection heat transfer. The multiphase particle-in-cell method is used to predict high-fidelity solid–gas flow characteristics, such as the local discrete particle size distribution, with increased computational efficiency by combining the advantages of both Eulerian and Lagrangian methods. The multi-component radiative transfer model is implemented using an advanced collision-based Monte Carlo ray-tracing method. The number of the prescribed discrete particle components is found to be the key parameter affecting the computational accuracy and efficiency, which primarily depends on the size distribution of the particles. For the model particle–gas flow featuring free-falling Gamma-distributed ceramic particles exposed to concentrated solar irradiation, the particle volume fraction, radiative, fluid flow and thermal characteristics appear to converge with the increasing number of the discrete particle components. Five particle components are sufficient to obtain physically meaningful results. A further increase in the number of the particle components only slightly increases the accuracy of the numerical predictions at the expense of a rapidly increasing computational time. For five particle components, the particle vertical velocity at the receiver exit for particles with the diameter of 43.4 μm is 57% of that for the particles with the diameter of 202.8 μm. The temperatures of these two particle components increase from the initial ambient values by factors of 2 and 1.2, respectively, during the simulation time. In conclusion, the model developed allows for increased fidelity of particle–gas flow simulations with significant radiative effects.

97 MATHEMATICS AND COMPUTING↗

Estimates of fluid and energy balances of Apollo 17

Fluid and caloric balance has been calculated for the Apollo 17 crew. This included measurement of nitrogen, water, and caloric value of the ingested food and the volume and nitrogen content of the excreted urine and feces. Body composition changes were determined from total body water and extracellular fluid volume differences. The body composition measurements made it possible to divide the weight loss into lean body mass and adipose tissue losses. From this division a caloric equivalent was calculated. These tissue losses indicated that the caloric requirements of the mission were considerably greater than the actual caloric intake. The 3.3 kilo mean loss of body weight represented 1 kilo of lean body mass and 2.3 kilos of adipose tissue. Calculated fluid balance was more positive during the mission than during the control period. These changes are unlike the body composition and fluid balance changes reported in bedrested subjects.

Johnson, P. C.↗

Exploring the impact of surface topography on Rayleigh-Bénard dry convection in the Pi cloud chamber using OpenFOAM: In cylindrical and rectangular geometries

The Pi convection-cloud chamber can generate steady-state turbulence in both rectangular and cylindrical shapes via Rayleigh-Bénard convection (RBC) by maintaining warm bottom and cold top surfaces. Although most experiments in the Pi chamber were conducted in cylindrical shapes, all previous Pi chamber simulations were conducted in a rectangular shape due to the limitations of those models to discretize a cylindrical domain when using the finite difference method therein. Here, we use OpenFOAM, an open-source finite-volume-based Computational Fluid Dynamics (CFD) software package, to conduct Large-Eddy Simulation (LES) of dry RBC in the Pi chamber at high Rayleigh numbers (10 8 to 10 9 ). Results show that large-scale circulation (LSC) direction varies in the chamber with a constant side wall temperature. Imposing a slight temperature imbalance at the side wall ranging from 0.1 to 0.7 degrees can lock the LSC, aligning better with Pi chamber observations, particularly at higher Rayleigh numbers. In addition, we examine the impact of surface topography on LSC and heat transfer in RBC systems within cylindrical and rectangular shapes under varying conditions. Results show that roughing top/bottom surfaces by adding bars of a few tens millimeters height can strengthen thermal plumes and enhance temperature fluctuations in the chamber. Furthermore, we observe that different bar height configurations lead to notable changes in LSC orientation and thermal stratification, highlighting the complex interactions between surface features and convection patterns. This finding highlights how surface topography and chamber geometry affect Rayleigh-Bénard convection, improving understanding of turbulent heat transfer and atmospheric boundary-layer processes. Direct Numerical Simulations (DNS) are also conducted to validate LES results. In conclusion, while LES effectively captures qualitative behaviors seen in DNS, it tends to underestimate velocity variances near walls, illustrating a trade-off between computational efficiency and accuracy.

54 ENVIRONMENTAL SCIENCES↗

Stress Controls Rupture Extent and Maximum Magnitude of Induced Earthquakes

Abstract Seismic hazard forecasts of induced seismicity often require estimates of the maximum possible magnitude ( M max ). Empirical models suggest that maximum magnitudes, or expected number of earthquakes, are related to the volume of injected fluid. We perform a suite of 3D physics‐based earthquake simulations with rate‐ and state‐dependent friction, systematically varying the area of the pressurized region and the amplitude of the initial homogeneous or heterogeneous shear stress. Using the resulting catalog we explore the conditions that result in pressure‐controlled versus runaway ruptures that extend outside the pressurized zone. We find that proposed empirical scaling laws correctly predict M max when shear stresses are further from failure (≤90% of maximum shear stress) and for high amplitude stress fields. Runaway ruptures are observed for higher initial shear stresses and smoother stress fields. In these cases, runaway ruptures occur early after the onset of injection and rarely preceded by foreshock activity.

58 GEOSCIENCES↗

Coupled Electro-Thermal Analysis of Permanent Magnet Synchronous Motor for Electric Vehicles

Permanent magnet synchronous motors (PMSM) are extensively used in electric vehicles. However, high internal heat generation and inefficient heat dissipation often limit the operational reliability, and longevity of the PMSM. Therefore, proper quantification of heat generation in electric motor and advanced embedded motor cooling techniques remain topics of immense interest. In order to accurately predict electro-magnetic performance, i.e., efficiency, component-wise heat losses and the corresponding temperature distribution of a jacket cooled machine, this paper presents a two-way iteratively coupled electro-thermal modeling framework. Finite element based software Motor-CAD has been utilized for electro-magnetic performance calculation of BMW i3 PMSM. Finite volume based computational fluid dynamics/heat transfer (CFD/HT) software ANSYS® FLUENT® has been employed to simulate the temperature distribution of the PMSM, using the electro-magnetic losses as heat input. Computed heat losses, stator, winding, rotor, and magnet temperatures are utilized as coupling parameters between the electro-magnetic and thermal models. A conventional one-way coupling algorithm has also been developed and compared to the newly proposed two-way coupling algorithm. Numerical results confirm that at high current density, one-way coupling algorithm significantly over-predicts the motor temperature compared to the two-way algorithm. A comprehensive analysis has been carried out to characterize the influences of current density, speed, and forced convection heat transfer coefficient on the heat losses, overall efficiency, and maximum temperature of the PMSM. Lastly, an efficiency map has been interpreted from the coupled electro-magnetic simulation.

42 ENGINEERING↗

Performance Evaluation of Engineered Geothermal Systems Using Discrete Fracture Network Simulations

Electrical power production from geothermal energy has a solid record of success for permeable reservoirs such as The Geysers in northern California and geothermal systems in Iceland and New Zealand, among other places. Such permeable reservoirs, however, represent only a small fraction of the available heat energy in the earth’s shallow crust. Most of the available energy resides in rocks with insufficient permeability and storage to produce commercial volumes of heated fluids.

15 GEOTHERMAL ENERGY↗

A detailed analysis of the erythropoietic control system in the human, squirrel, monkey, rat and mouse

The erythropoiesis modeling performed in support of the Body Fluid and Blood Volume Regulation tasks is described. The mathematical formulation of the species independent model, the solutions to the steady state and dynamic versions of the model, and the individual species specific models for the human, squirrel monkey, rat and mouse are outlined. A detailed sensitivity analysis of the species independent model response to parameter changes and how those responses change from species to species is presented. The species to species response to a series of simulated stresses directly related to blood volume regulation during space flight is analyzed.

Nordheim, A. W.↗

Computer simulation studies in fluid and calcium regulation and orthostatic intolerance

The systems analysis approach to physiological research uses mathematical models and computer simulation. Major areas of concern during prolonged space flight discussed include fluid and blood volume regulation; cardiovascular response during shuttle reentry; countermeasures for orthostatic intolerance; and calcium regulation and bone atrophy. Potential contributions of physiologic math models to future flight experiments are examined.

Source record↗

Ageing and water homeostasis

This review outlines current knowledge concerning fluid intake and volume homeostasis in ageing. The physiology of vasopressin is summarized. Studies have been carried out to determine orthostatic changes in plasma volume and to assess the effect of water ingestion in normal subjects, elderly subjects, and patients with dysautonomias. About 14% of plasma volume shifts out of the vasculature within 30 minutes of upright posture. Oral ingestion of water raises blood pressure in individuals with impaired autonomic reflexes and is an important source of noise in blood pressure trials in the elderly. On the average, oral ingestion of 16 ounces (473ml) of water raises blood pressure 11 mmHg in elderly normal subjects. In patients with autonomic impairment, such as multiple system atrophy, strikingly exaggerated pressor effects of water have been seen with blood pressure elevations greater than 75 mmHg not at all uncommon. Ingestion of water is a major determinant of blood pressure in the elderly population. Volume homeostasis is importantly affected by posture and large changes in plasma volume may occur within 30 minutes when upright posture is assumed.

Review↗

Gas Foil Bearings for Space Propulsion Nuclear Electric Power Generation

The choice of power conversion technology is critical in directing the design of a space vehicle for the future NASA mission to Mars. One candidate design consists of a foil bearing supported turbo alternator driven by a helium-xenon gas mixture heated by a nuclear reactor. The system is a closed-loop, meaning there is a constant volume of process fluid that is sealed from the environment. Therefore, foil bearings are proposed due to their ability to use the process gas as a lubricant. As such, the rotor dynamics of a foil bearing supported rotor is an important factor in the eventual design. The current work describes a rotor dynamic analysis to assess the viability of such a system. A brief technology background, assumptions, analyses, and conclusions are discussed in this report. The results indicate that a foil bearing supported turbo alternator is possible, although more work will be needed to gain knowledge about foil bearing behavior in helium-xenon gas.

Howard, Samuel A.↗