At least 397 records · Page 22

A methodology to develop multi-physics dynamic fuel cell system models validated with vehicle realistic drive cycle data

Fuel cell (FC) technology has been identified as a technically attractive solution to decarbonize the transportation sector, especially for heavy-duty vehicles. In this context, the industry and the scientific community are in need of advanced fuel cell systems (FCS) models that are able to replicate real -world operating conditions. Due to the scarcity of said models in the open literature, this study aimed to develop a comprehensive methodology to calibrate and validate multi -physics dynamic FCS models. Therefore, the key contribution of this paper is the detailed description of the calibration process for each component and the calibration order. The specific focus here was to accurately describe the behavior of the FC stack as well as the cathode, anode, and cooling circuits of the balance of plant. The model was calibrated with the aid of experimental data from a Toyota Mirai FC electric vehicle, which was predominantly retrieved from the vehicle's Controller Area Network (CAN) bus system thereby negating the need for major intrusion into the powertrain system. The validation process was deemed successful with the model being able to truthfully replicate the characteristics of the FC vehicle operated on the World-wide harmonized Light duty Test Cycle (WLTC) 3b and US06 driving cycle. The time -resolved physical parameters such as the cathode pressure, mass flow, or the FC stack temperature were captured with high fidelity, while the overall performance parameters such as the H2 consumption in the stack and the system, and the compressor energy consumption were predicted accurately with a deviation lower than 0.47%, 1.75% and 1.89% with respect to the experimental data, respectively.

Lopez-Juarez, Marcos↗

CFD modeling of turbulent air flow in self-heated gyroid TPMS structures: Thermal-hydraulic performance and validation

The application of mathematically derived geometries, such as triply periodic minimal surface (TPMS) lattices, has garnered significant interest across various fields, including the nuclear sector, due to their superior thermal-hydraulic characteristics for heat transfer compared to traditional plain or finned tubes. Here, this study validates a computational fluid dynamics (CFD) model, evaluates different turbulence models and CFD model settings, and performs uncertainty quantification to provide a comprehensive analysis. Despite extensive research on CFD modeling of TPMS lattices, such as gyroid and diamond geometries, there is a notable lack of publicly available literature providing comprehensive details on numerical analysis aspects, including convergence and methodological best practices. This study embarks on a benchmark analysis of a gyroid geometry to evaluate its thermal-hydraulic performance under turbulent flow conditions and scrutinize various CFD model configurations. The main contributions of this work include validating the CFD model, assessing and comparing different turbulence models, and enhancing pressure drop and temperature prediction capabilities. The results aim to support the development of methodologies needed to benchmark and enhance numerical analysis techniques for TPMS lattices. This work seeks to complement the existing body of knowledge, support the development of TPMS reactor concepts, and improve best practices for CFD modeling of TPMS lattices, ultimately advancing methodologies to support future applications in this domain.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

On the validity and limitations of 1D model for heat and mass transfer performance evaluation in a multilayer binder-free desiccant dehumidifier: isothermal dehumidification with internal cooling

Efficient humidity control is essential for maintaining indoor thermal comfort, yet conventional vapor-compression-based dehumidifiers are energy-intensive. Employing separate sensible and latent cooling through desiccant-coated heat exchangers (DCHEs) combined with evaporative coolers offers energy savings of up to 80 % compared to conventional systems. However, the dehumidification performance of DCHEs remains limited due to the use of polymer binders for coating desiccant materials onto heat exchange surfaces. In our previous study, we developed a multilayer fixed-bed binder-free desiccant dehumidifier (MFBDD) that demonstrated high dehumidification capacity and low pressure drop compared to rotary desiccant wheels. Nevertheless, its potential for further enhancement through internal cooling and the use of step-shaped adsorption isotherms has not been explored. In this study, a physics-based one-dimensional (1D) transient model is developed and validated to capture the coupled heat and mass transfer processes in the MFBDD and extended to simulate internal cooling using a high-capacity composite metal–organic framework, MIL-101/GO-6 (water uptake ≈1.6 g/g within 35–47 % RH). The model enables detailed analysis of local air and bed temperature dynamics and quantifies how internal cooling affects the dehumidification performance under a wide range of operating conditions. Results show that integrating internal cooling and using MIL-101/GO-6 enhance mass adsorbed, moisture removal capacity, and dehumidification effectiveness by 50 %–99 % compared with the M.S. Gel baseline. The study further reveals that achieving near-isothermal operation requires simultaneous enhancement of the convective heat transfer coefficient and heat exchange surface area. In conclusion, this work provides the first detailed physical insight into the interplay between internal cooling and step-shaped isotherms in a binder-free desiccant device and establishes a validated modeling framework for scaling up and system-level performance evaluation of next-generation energy-efficient dehumidification systems.

Heat and mass transfer↗

Validation of the TOPAS Monte Carlo toolkit for HDR brachytherapy simulations

The goal of this work is to validate the user-friendly Geant4-based Monte Carlo toolkit TOol for PArticle Simulation (TOPAS) for brachytherapy applications. Brachytherapy simulations performed with TOPAS were systematically compared with published TG-186 reference data. The photon emission energy spectrum, the air-kerma strength, and the dose-rate constant of the model-based dose calculation algorithm (MBDCA)-WG generic Ir-192 source were extracted. For dose calculations, a track-length estimator was implemented. Additionally, the four Joint AAPM/ESTRO/ABG MBDCA-WG test cases were evaluated through histograms of the local and global dose difference volumes. A prostate, a palliative lung, and a breast case were simulated. For each case, the dose ratio map, the histogram of the global dose difference volume, and cumulative dose-volume histograms were calculated. The air-kerma strength was (9.772 ± 0.001) × 10 -8 U Bq -1 (within 0.3% of the reference value). The dose-rate constant was 1.1107 ± 0.0005 cGy h -1 U -1 (within 0.01% of the reference value). For all cases, at least 96.9% of voxels had a local dose difference within [-1%, 1%] and at least 99.9% of voxels had a global dose difference within [-0.1%, 0.1%]. The implemented track-length estimator scorer was more efficient than the default analog dose scorer by a factor of 237. For all clinical cases, at least 97.5% of voxels had a global dose difference within [-1%, 1%]. Dose-volume histograms were consistent with the reference data. TOPAS was validated for high-dose-rate brachytherapy simulations following the TG-186 recommended approach for MBDCAs. Built on top of Geant4, TOPAS provides broad access to a state-of-the-art Monte Carlo code for brachytherapy simulations.

59 BASIC BIOLOGICAL SCIENCES↗

Validation and application of a multiphase CFD model for hydrodynamics, temperature field and RTD simulation in a pilot-scale biomass pyrolysis vapor phase upgrading reactor

Accurate prediction of transport phenomena is critical for VPU reactor design, optimization, and scale-up. The current study focused on the validation and application of a multiphase CFD model within an open-source code MFiX for hydrodynamics, temperature field, and residence time distribution (RTD) simulation in a non-reacting circulating fluidized bed riser for biomass pyrolysis vapor phase upgrading (VPU). First, an Eulerian-Eulerian approach three-dimensional CFD model was employed to simulate the pilot-scale VPU riser on the supercomputer Joule. Excellent quantitative agreement between experimental and simulated results was achieved for pressure drops and temperature field in a range of operating conditions. Then the validated multiphase CFD model was applied to predict gas and solid residence time distributions (RTDs) since prediction and analysis of RTD is an important tool to study the complex multiphase flow behavior and mixing inside chemical reactors. The predictions show that solid mean residence time is 3.5 times the gas residence time; the solid RTD is more sensitive to the process gas flow rate than the solids circulation rate.

09 BIOMASS FUELS↗

Physical model and experimental validation of a high temperature proton exchange membrane electrochemical hydrogen pump cell for efficient single-stage extraction of low concentration hydrogen gas

There is interest in valorization of existing natural gas infrastructure to facilitate the co-transportation of hydrogen via blending of hydrogen gas initially at limited concentrations of 1–20 vol% H2 and to subsequently extract hydrogen at fuel cell quality standards (SAE J2719/ISO14687-2). High temperature proton exchange membrane electrochemical hydrogen pump (HT-PEM EHP) based on phosphoric acid doped polybenzimidazole (PA-PBI) exhibits good performance at elevated temperatures (>120 °C), which provides desirable tolerance to non-methane natural gas constituents that are problematic for lower temperature based EHP. To better understand the suitability of the HT-PEM EHP for such gas separation processes, a two-dimensional model of EHP based on PA-PBI was developed. The model is validated for several relevant operating conditions and across cells with differing amounts of phosphoric acid content in the electrodes. Operando micro x-ray computed tomography (CT) imaging of an HT-PEM EHP was used to further validate physical parameters and assumptions of the model. The impacts of pressure, relative humidity of the anode feed, and concentration of feed gases on separation performance are investigated. This study shows that a specific energy of separation of 5.1 kWh/kg H2 at a hydrogen recovery factor (HRF) of 50 vol% can be achieved in a single stage with the EHP, producing fuel cell quality hydrogen purity of 99.99 vol% H2 from a 2 vol% H2/CH4 feed blend, while pressurizing the product H2 at a pressure ratio of 1.3 relative to feed pressure.

Stansberry, John M↗

Validation of process simulation workflow for thermosetting prepreg platelet molding compounds

Continuous carbon fiber prepreg slit and cut into rectangular platelets has proven to be a useful material for net shape molding of semi-structural and structural components in the aerospace and automotive industries. Furthermore, to assist the designer in use of these prepreg platelet molding compounds, sometimes called carbon fiber sheet molding compounds, simulation tools are required that can predict the as-manufactured fiber orientation state which has a significant impact on the resulting performance. Herein, an analysis workflow for design-enabling predictions is demonstrated for a double dome geometry with two different initial charge configurations. Here, the workflow is validated through comparison with experimental short shots, orientation state, and stiffness trends. Significantly, to complete the validation, a method is proposed for determining the confidence bounds on measured orientation state enhancing the results of optical microscopy which can only produce a small sample of platelet orientations.

36 MATERIALS SCIENCE↗

Validating corrosion models: Influence of physical properties

In chloride containing environments, two metals in physical contact can undergo galvanic corrosion limiting the lifetime of components. Being able to accurately predict galvanic corrosion damage distributions over time has not been widely presented in literature. Therefore, Finite Element Method (FEM) corrosion models were experimentally validated for two galvanic couples as a function of governing equations, environment, anode material, anode:cathode ratio, and time. Carbon steel/stainless steel (CS/SS) and zinc/stainless steel (Zn/SS) galvanic couples were exposed to NaCl solutions at room temperatures for up to 14 days. For the galvanic couples and environments, the Laplace equation with variable conductivity and reactions was sufficient to model the experimental corrosion damage. Increasing the chloride concentration for the CS/SS galvanic couple, regardless of the anode:cathode ratio, decreased the observed and modeled corrosion damage. Decreasing the anode:cathode ratio (i.e., increasing the cathode length), increased the experimentally observed and modeled corrosion damage. For small anode:cathode ratios, the governing equations deviate over long time periods with the Nernst-Plank equation being conservative. For the Zn/SS galvanic couple, the cathode length controls the dominant cathodic reduction reaction. For small cathode lengths, the hydrogen evolution reaction is dominant. For larger cathode lengths, the oxygen reduction reaction is dominant. The results are discussed with regard to the influence of solution chemistry, ohmic drop, and governing reactions. Overall, validated FEM models were presented, and the resultant models, physics, and mechanisms can be applied to other corrosion scenarios with confidence.

Carbon steel↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

Measurement-driven, model-based estimation of residual stress and its effects on fatigue crack growth. Part 1: Validation of an eigenstrain model

The objective of this paper is to validate a measurement-driven, model-based approach to estimate residual stress (RS) in samples machined from quenched aluminum stock. Model input is derived from measurement of RS in the parent stock. Validation is performed for prismatic T-sections removed from bars at different locations. We find RS predicted agrees with RS measured, by contour and neutron diffraction methods, with root-mean-square model-measurement difference of 22 MPa. Follow-on work (in Part 2) applies the RS estimation to samples representative of aircraft structures and examines the effects of RS on fatigue crack growth in the RS-bearing samples.

36 MATERIALS SCIENCE↗

Multi-scale dynamic modeling and validation of radial flow fixed bed contactors for post-combustion CO 2 capture using bench scale and pilot plant data

Here, in this work, a multi-scale model of a radial flow fixed bed contactor packed with a carbon sorbent is developed and validated with laboratory-scale and pilot plant scale dynamic data. For the lab scale system, the model results were compared with low, medium and high gas and sweep flowrates, yielding root mean square error (RMSE) of 0.80, 0.63, 0.96 CO 2 mol%, respectively, for the outlet CO 2 concentration profile considering the entire A-D cycle. For the bed outer temperature profile, maximum RMSE was found to be 5.5 °C considering all flowrates and entire A-D cycles. An experimental campaign was developed and applied to a pilot plant at Technology Center Mongstad (TCM), Norway. Approaches were developed for pre-processing of data including consideration of the effect of gas mixing, measurement delay, and determination of cyclic steady-state conditions. Considering profiles during A-D cycles for all test runs, it was found that the maximum RMSE for pressure drop, temperature for the outer section of the bed, temperature for the middle section of the bed, and outlet CO 2 concentration profile remained less than 1.5 mbar, 3.5 °C, 2.8 °C, and 1.3 CO 2 mol%, respectively. The validated model was used to perform sensitivity studies on several key design operating variables for the adsorption-desorption cycle. It was found that the flow rate and concentration of flue gas have dominant nonlinear effects on the breakthrough time while the desorption time was strongly affected by the sweep gas flowrate for the specific sorbent being evaluated in this study.

20 FOSSIL-FUELED POWER PLANTS↗

Development, validation, and verification of multi-pass thermo-mechanical welding simulations using the open-source MOOSE framework: NeT TG4 benchmark weldment

This study develops and validates a sequentially coupled thermo-mechanical welding simulation for the three-pass 316L stainless steel NeT TG4 benchmark weldment using the open-source Multiphysics Object-Oriented Simulation Environment (MOOSE) and the Nuclear Engineering Material model Library (NEML). A diffused ellipsoidal heat source was calibrated against thermocouple data and weld macrographs to accurately model the fusion zone geometry and transient thermal fields. Material hardening is represented using the Lemaitre-Chaboche mixed isotropic-kinematic hardening model, while four annealing models - no annealing, single-stage at 1050 °C and 1300 °C, and two-stage at 800 °C/1300 °C - were implemented to assess the impact of annealing models on the accuracy of the predicted welding-induced plasticity, distortions, and residual stresses. The predictions were validated against experimental measurements and benchmarked against results from commercial software, demonstrating that thermo-mechanical MOOSE welding simulations achieve comparable accuracy with enhanced computational efficiency. This work highlights the potential of using open-source finite element frameworks like MOOSE for advanced manufacturing simulations.

Ji, Wendy [Australian Nuclear Science and Technolo↗

Low Activity Waste Glass Optimization with Property Models from Machine Learning, Part 2: Experimental Validation and Active Learning

The United States Department of Energy is responsible for managing legacy nuclear waste stored in underground tanks at the Hanford Site. To treat the waste, it is planned as the current baseline to separately vitrify low-activity waste (LAW) and high-level waste fractions. Previously, machine learning (ML) based glass property models (e.g., chemical durability, viscosity, electrical conductivity and SO3 solubility) were developed with prediction uncertainties. A waste glass optimization approach was then established to enable the capability of using these ML models in LAW glass formulation. In this study, the previous ML models were first experimentally validated, and the results were incorporated back into the database to update the ML models. The updated models and formulations showed increased waste loading while reducing the failure rate, demonstrating improved predictive accuracy, reduced uncertainties, and the effectiveness of active learning in guiding high-dimensional, nonlinear LAW glass design. This represents the first experimental validation of ML based LAW glass formulation, with practical benefits such as higher waste loading, shorter mission duration, and lower operational risk.

Lu, Xiaonan (ORCID:0000000179708148)↗

An experimentally validated mesoscale model for the effective thermal conductivity of U-Zr fuels

An experimentally validated mesoscale model was developed to simulate the effective thermal conductivity (ETC) of metallic U and U–Zr nuclear fuels. The effects of microstructure, temperature, composition, and interfacial thermal resistance (ITR) were investigated. Companion experiments were conducted to validate the model. The numerical simulations clearly demonstrate that accounting for the interface (Kapitza) thermal resistance and Zr precipitation is necessary to improve the model predictions. The dependence of the effective Kapitza resistance of depleted-U and U-10Zr on temperature was determined. Finally, for both materials, the largest difference between the model calculations and the experimental data was about 4.5%, which is within the precision of the experimental measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dissolved gas recovery from water using a sidestream hollow-fiber membrane module: First principles model synthesis and steady-state validation

This paper presents a first-principles model for the recovery of dissolved gases from liquids using a sidestream hollow-fiber membrane module. The model avoids the use of new empirical coefficients, thus providing a parametric understanding of the process behavior for future design and optimization of membrane modules. This type of first-principles model could be particularly useful when gas recovery is beneficial to biological or chemical reactions of interest, such as the acetogenesis reactions in two-stage anaerobic digesters. The steady-state behavior of the model was validated against both new experimental data for the recovery of H 2 , CH 4 and H 2 –CH 4 mixtures from pure water, as well as existing published data. The modeled gas recovery predictions agreed with experimental data to an absolute average error of 13%, and an average R value of 0.98. Parametric analysis of mixed-gas recovery suggests possible key transition points in the composition of the recovered gases. For example, at 40 °C, increasing trans-membrane pressure while keeping hydraulic residence time (HRT) under 0.5 s will result in an increase in the ratio of H 2 to CH 4 recovered. Otherwise, increasing trans-membrane pressure will instead decrease the ratio of H 2 to CH 4 recovered. The model has potential to be extended to transient analysis, but has yet to be validated with transient experimental data. Furthermore, this model was successfully implemented in both Python and MATLAB, and provides valuable insights for future net-energy optimization for anaerobic digestion systems with in-situ gas recovery.

Anaerobic Digestion↗

Inhibition of asphaltene aggregation using deep eutectic solvents: COSMO-RS calculations and experimental validation

Asphaltene precipitation/deposition adversely affects various oil and gas processes, such as oil recovery, transportation, and petroleum processing. The resulting increase in viscosity of crude oil decreases distillate yields creating unstable phase separation. Deep eutectic solvents (DESs) have recently gained interest as inhibitors of asphaltene aggregation. The goal of the present study is to derive the mechanism of inhibition of petroleum asphaltene aggregation by a novel screening of DESs. An archipelago-based chemical structure of asphaltene was adopted for performing quantum chemical calculations. The structure was used in the conductor-like screening model for real solvents (COSMO-RS) model to screen potential DESs for asphaltene precipitation. It was found that DESs containing thymol were the most promising of the 153 DES combinations screened. The COSMO-RS predictions were validated experimentally using solubility data of asphaltene in DESs. Among the studied DESs, thymol-diphenyl ether provided the highest solubility for asphaltene, which was further validated using the experimental and the COSMO-RS predicted data. In addition, to characterize the structural interactions between asphaltene and DESs, Fourier transform infrared (FTIR) spectroscopy and nuclear magnetic resonance (NMR) measurements were performed. It was found that strong interaction between asphaltene and the DESs is responsible for the higher asphaltene dispersion. Finally, the present approach opens pathways to rationally design and understand the impact of structural variation of DESs based on their interactions with asphaltene.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Verification of the sensitivity and uncertainty-based criticality safety validation techniques: ORNL’s SCALE case study

The use of sensitivity and uncertainty-based techniques has been well-developed in the neutronic community for criticality safety applications. Sensitivity techniques calculate the first-order relative variations in keff due to relative cross-section variations by isotope, reaction type, and incident neutron energy. The result is a vector of sensitivity coefficients which is folded with prior cross-section uncertainties to calculate the so-called similarity indices. Similarity indices are integral quantities which serve as useful mathematical measures for assessing the relevance of existing or new experiments to given application conditions, representing design systems for which the models are to be validated. Despite their importance for a wide range of validation activities, the peer-reviewed literature is non-existent on the development of rigorous verification analysis for their calculated values. Thus, this manuscript proposes a simple non-intrusive method to calculate similarity indices, serving as an independent verification tool for their evaluation. The manuscript derives the theoretical basis for the proposed verification analysis. Next, the verification analysis is applied to the ORNL’s SCALE code suite which employs adjoint-based methods to calculate similarity indices. Numerical experiments using a number of well-known benchmark experiments are employed to verify the calculation of the similarity indices.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗