Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Methods for Analyzing the Benefits and Costs of Distributed Photovoltaic Generation to the U.S. Electric Utility System

This report outlines the methods, data, and tools that could be used at different levels of sophistication and effort to estimate the benefits and costs of DGPV. In so doing, we identify the gaps in current benefit-cost-analysis methods, which we hope will inform the ongoing research agenda in this area. The focus of this report is primarily on benefits and costs from the utility or electricity generation system perspective. It is intended to provide useful background information to utility and regulatory decision makers and their staff, who are often being asked to use or evaluate estimates of the benefits and cost of DGPV in regulatory proceedings. Understanding the technical rigor of the range of methods and how they might need to evolve as DGPV becomes a more significant contributor of energy to the electricity system will help them be better consumers of this type of information. This report is also intended to provide information to utilities, policy makers, PV technology developers, and other stakeholders, which might help them maximize the benefits and minimize the costs of integrating DGPV into a changing electricity system.

14 SOLAR ENERGY↗

High Energy Yield Distributed Architecture for Large Commercial and Utility-Scale PV Systems

Photovoltaic energy has come a long way from its early days when small cells were fabricated in the labs in the early 50s. While it took a long time for PV modules to mature into what we now see in the market and in rooftops across the world, the power electronics has been lagging behind & was always the weakest point in the PV plant, being responsible for the majority of failures & robbing the PV plants of their full potential by losing precious Watts in the process of converting power from DC to AC. Since the early days of PV power, it has been recognized that the modules need to operate at their maximum power point in order to extract as much power as is available from the PV modules at a given time of day and year. Numerous maximum power point devices were developed to do just this. While effective at extracting as much power as they can, soon after there was a realization that in a PV installation where a central inverter is used, many losses occur, hence energy yield losses. This has led to thinking about alternative architectures where the maximum power point tracking (MPPT) is performed much closer to the modules rather than at a central inverter. Several architectures were proposed ranging from a microinverter, microconverter, string inverter, string optimizer, and to a multi-string inverter or optimizer. While these architectures promise to increase the energy yield by 5% to 25% (depending where MPPT is located), & recovering losses due to shading, soiling, mismatch … there were no real studies and implementations in the field to corroborate these numbers. The program that GE Global Research proposed & received funding for is aimed at a type of distributed architectures, namely the dc architectures where only the MPPT function is distributed across the PV plant. Further, the project is concerned with choosing the right architecture for large scale commercial & utility scale plants but not residential installations. Findings from Task 1- Define Requirements & Develop Architecture- showed that for large scale commercial & utility PV plants, locating the MPPT at the string level with a string size of >3kW is the most cost effective solution & that the increase in energy yield of 6% to 8% is more than enough to make up for the increased cost due to additional power electronics. Our study also shows that in addition to an increase in energy yield, having a dc/dc converter at the string level brings additional benefits such as increased array visibility, allowing for increased monitoring and diagnostics; high and constant dc bus voltage which allows for reducing losses further and optimizing the inverter; and ability to detect ground and arc faults. Task 2 focused on designing a suitable dc/dc converter that meets the requirements defined in Task 1: Efficiency, Cost, & Reliability. For this task, we surveyed and simulated all candidate topologies known by the practitioners in the field. We also generated a novel topology, simulated it, & compared it to existing topologies. Our novel topology being a partial power processing converter came out on top due to its simplicity (fewer parts), it high efficiency, its reliability, and its lower cost. In the remaining tasks of the project, we built the hardware, tested it first in the lab, then in the field and once we worked out all the bugs and issues and were confident our system was robust, we installed it on the rooftop and started collecting the data by mid-Q3 2012. We shared our work with the scientific community in the form of conference & Journal papers, hence contributing to the general understanding of this technology area. The methods, techniques, and hardware developed under this project have all been tested in the field over long periods of time, and under many conditions and have been shown to be robust and reliable. The converters built and developed under this program have been in operation in the field since mid-June 2012, and no hardware failures have been recorded. While some software issues have been seen, none have been showstoppers. The cost analysis of the hardware showed that it meets the cost target set in the requirement document developed in the trade-off study. Improving the performance of solar installations for commercial and utility scale plants contributes to reducing their cost of ownership, hence spreading them to a larger section of the society and making them affordable. Our project contributed to the understanding of the distributed architectures, showed that PV plants’ cost of electricity can be reduced through additional power electronics which allows for harvesting more energy from the plant. When the project started in 2009, the cost of PV energy was still high, hence there was a real need to increase the energy yield, hence reduce the levelized cost of electricity (LCOE). While costs have come down significantly, the need for increasing the energy yield is still relevant, hence the project results, hardware, and techniques developed are still pertinent today. By taking this project from concept to rooftop demonstration, we showed that the technology is mature enough, robust enough, and has the potential to be used by many more customers, hence benefiting the public in general through the spread of PV energy, which ultimately contributes to reducing our dependency on fossil fuel, improving the environment, and creating more jobs.

14 SOLAR ENERGY↗

What is the Impact of Utility Demand Charges on a DCFC host

The PEV Electric Vehicle Supply Equipment (EVSE) delivered by The EV Project included both AC Level 2 and DCFC units. Over 100 of these dual-port Blink DC fast chargers were deployed by The EV Project. These DCFCs were installed in workplaces and in publicly accessible locations near traffic hubs, retail centers, parking lots, restaurants, and similar locations. The Blink DCFC is capable of charging at power up to 60 kW. Its dual-port design sequences the charge from one port to the other, delivering power to only one of two vehicles connected at a time. The actual power delivered through a port is determined by the PEV’s on-board battery management system (BMS). Both the power and the total energy used to recharge a PEV can represent a significant cost for the charging site host. Many electric utilities impose fees for power demand as part of their commercial rate structure. The demand charge incurred by a customer is related to the peak power used during a monthly billing cycle. This is in contrast to the cumulative total energy usage that is the more familiar utility charge seen for most residential services. A demand charge is typically assessed for the highest average power over any 15 minute interval during the monthly billing cycle. One objective of The EV Project was to identify and elucidate the motivations and barriers to potential DCFC site hosts. The application of electric utility demand charges is one such potential barrier. This subject was introduced in the paper: DC Fast Charge - Demand Charge Reduction1. It discussed demand charge impact in general terms in order to focus on potential mitigation actions. This paper identifies specific cases in order to quantify the impact of demand charges on EV Project DCFC hosts.

33 ADVANCED PROPULSION SYSTEMS↗

Charting the Emergence of Corporate Procurement of Utility-Scale PV

Through July 2017, corporate customers contracted for more than 2,300 MW of utility-scale solar. This paper examines the benefits, challenges, and outlooks for large-scale off-site solar purchasing through four pathways: PPAs, retail choice, utility partnerships (green tariffs and bilateral contracts with utilities), and by becoming a licensed wholesale seller of electricity. Each pathway differs based on where in the United States it is available, the value provided to a corporate off-taker, and the ease of implementation. The paper concludes with a discussion of future pathway comparison, noting that to deploy more corporate off-site solar, new procurement pathways are needed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Charting the Emergence of Corporate Procurement of Utility-Scale PV

Corporations and other institutions have contracted for more than 2300 MW of off-site solar, using power purchase agreements, green tariffs, or bilateral deals with utilities. This paper examines the benefits, challenges, and outlooks for large-scale off-site solar purchasing in the United States. Pathways differ based on where they are available, the hedge value they can provide, and their ease of implementation. The paper features case studies of an aggregate PPA (Massachusetts Institute of Technology, Boston Medical Center, and Post Office Square), a corporation exiting their incumbent utility (MGM Resorts), a utility offering large scale renewables to corporate customers (Alabama Powers Renewable Procurement Program), and a company with approval to sell energy into wholesale markets (Google Energy Inc.).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterization of PTO and Idle Behavior for Utility Vehicles

This report presents the results of analyses performed on utility vehicle data composed primarily of aerial lift bucket trucks sampled from the National Renewable Energy Laboratory's Fleet DNA database to characterize power takeoff (PTO) and idle operating behavior for utility trucks. Two major data sources were examined in this study: a 75-vehicle sample of Odyne electric PTO (ePTO)-equipped vehicles drawn from multiple fleets spread across the United States and 10 conventional PTO-equipped Pacific Gas and Electric fleet vehicles operating in California. Novel data mining approaches were developed to identify PTO and idle operating states for each of the datasets using telematics and controller area network/onboard diagnostics data channels. These methods were applied to the individual datasets and aggregated to develop utilization curves and distributions describing PTO and idle behavior in both absolute and relative operating terms. This report also includes background information on the source vehicles, development of the analysis methodology, and conclusions regarding the study's findings.

54 ENVIRONMENTAL SCIENCES↗

California Publicly-Owned Utilities (POUs) – LBNL ‘Beyond Widgets’ Project. Task: ambient lighting and occupancy-based plug load control. System Program Manual

This program manual contains detailed technical information for implementing an incentive program for task-ambient lighting and occupancy-based plug load control. This manual was developed by Lawrence Berkeley National Laboratory, in collaboration with the California Publicly-Owned Utilities (CA POUs) as a partner in the ‘Beyond Widgets’ program funded by the U.S. Department of Energy Building Technologies Office. The primary audience for this manual is the program staff of the various CA POUs. It may also be used by other utility incentive programs to help develop similar programs. It is anticipated that the content of this manual be utilized by the CA POU staff for developing related documents such as the Technical Resource Manual and other filings pertaining to the rollout of an energy systems-based rebate incentive program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Cost of Saving Electricity Through Energy Efficiency Programs Funded by Utility Customers: 2009–2015

The average cost to utilities to save a kilowatt-hour (kWh) in the United States is 2.5 cents, according to the most comprehensive assessment to date of the cost performance of energy efficiency programs funded by electricity customers. These costs are similar to those documented earlier. Cost-effective efficiency programs help ensure electricity system reliability at the most affordable cost as part of utility planning and implementation activities for resource adequacy. Building on prior studies, Berkeley Lab analyzed the cost performance of 8,790 electricity efficiency programs between 2009 and 2015 for 116 investor-owned utilities and other program administrators in 41 states. The Berkeley Lab database includes programs representing about three-quarters of total spending on electricity efficiency programs in the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovative Utility Offerings at the Distribution Edge: Case Studies from Around the Globe

The global evolution of the electricity sector - from deregulation, to higher penetrations of DERs, to digitization and changing consumer preferences - has delivered the utility industry to an inflection point. The vertically integrated, regulated model that persisted over most of the 20th century is undergoing a transformation, and utilities worldwide are responding with new approaches to the provision of products and services. This report catalogs several of these innovative approaches to incorporate new technologies such as electric vehicles, meet societal goals for a cleaner, more efficient electricity system, and empower consumers to make smarter energy choices and provide system benefits. The report comprises a series of 10 case studies across six continents, and features solutions touching on energy supply, energy efficiency, lighting, transport, data, heating and cooling, and rural/off-grid solutions. The diversity of products, programs, and markets documented illustrates the extent of the shift underway. Ultimately, the report demonstrates that utilities will continue to serve as critical partners in a global energy transition, and have been actively engaged in securing their position as such.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operationalizing Synchrophasors for Enhanced Grid Reliability and Asset Utilization

The report discusses the development of production-grade synchrophasor software applications. The objective is to improve system reliability and asset utilization for offline as well as real-time considerations, as per the Department of Energy (DOE) guidelines specified by Funding Opportunity Announcement (FOA) DE-FOA-0001492. On the one hand, we have developed grid management applications on how to transform synchrophasor-based monitoring into operator guidance, and commercial grade tools addressing industry needs such as NERC Reliability Standards (MOD 26, MOD 27 and MOD 33). On the other hand, with the wide industrial adoption in mind, the developed applications have been fully discussed with utility partners and installed in the utility partners site including 6 field tests. The Model Validation and Calibration software module has been integrated into GE’s PhasorAnalyticsTM. The first commercial contract has been signed even before the close date of this project. The Angle-based Grid Management (AGM), Fast Voltage Security Assessment (FastVSA), Enhanced Islanding Monitoring(EIM) and Enhanced Disturbance Management (EDM) have been integrated into GE’s Grid Stability Assessment line of applications in e-terra Suite of EMS product.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving the Economic Viability of Biological Utilization of Coal Power Plant CO 2 by Improved Algae Productivity and Integration with Wastewater Treatment

The overall goal of this project was to improve the cost-effectiveness of systems using algae to capture and beneficially utilize CO 2 from the flue gas of coal-fired power plants. Algal biomass cultivation is an attractive alternative for carbon capture and utilization because it can uptake more CO 2 per land area than any other photosynthetic crop. Also, the resulting biomass can be used to make valuable large-market commodity products, such as biofuels and animal feed. However, the use of algal carbon capture has been limited by several factors including: (1) high costs for growing algae (>$\$1,300$/ton), (2) large land requirements for algae cultivation, and (3) environmental concerns about the large amount of water and nutrient inputs needed for growing algae. This project has taken direct aim at resolving these key limitations and demonstrated several viable approaches to improve the economic and environmental feasibility of algal carbon capture. In particular, this project demonstrated a significant increase in average annual algal productivity from baseline values of 8 g/m 2 -day to above 20 g/m 2 -day. This supports a much lower projected cost of algae production (<$\$500$/ton) and reduces land requirements by more than 50%. Additionally, this project confirmed the ability to grow multiple algae species with wastewater nutrients, which facilitates the potential for substantial new revenue streams for algae cultivation based on tipping fees for nutrient laden wastewater. This study highlighted that there is more potential value in wastewater nutrient treatment credits than in the primary commodity products made from algae. The use of wastewater inputs also mitigates the concerns associated with the large amount of water needed for growing algae. The algal biomass grown for this project using wastewater and simulated flue gas inputs were characterized for potential use as an animal feed ingredient. The algae had a protein content in the range of 35-40%, which is between some common commodity animal feed products— distiller’s grains (~25-30% protein) and soybean meal (45-50% protein). In-vitro digestion tests using cattle rumen fluids, showed that this algae biomass was best suited for use as “bypass protein”, which is digested in the animal intestine. Based on the protein content and amino acid profile of the algae grown in this study, it was estimated to have market value in the range of $\$190$-$\$280$/ton. There is potential for higher value feed products if the algae content of omega-3 fatty acids or antioxidants is accounted for. This project also did small scale demonstration of forward osmosis algae dewatering and nanofiltration of hydrothermal liquefaction aqueous products, which were shown to improve the cost and energy balance for producing algal products. When all the improvements demonstrated in this study were included in techno-economic analysis, it showed there was a viable pathway to profitable algal CO 2 utilization with a payback period in the range of six to ten years.

01 COAL, LIGNITE, AND PEAT↗

Cybersecurity for Energy Systems: Foundational Concepts for Bangladesh Electric Utilities [Slides]

This slide deck was developed for a training for the Northern Electricity Supply Company (NESCO) in Rajshahi, Bangladesh. The topics include: understanding the cybersecurity landscape in power utilities, fundamentals of cybersecurity for power utilities, regulatory compliance and standards, and best practices and strategies. The concepts in this slide deck are relevant for electric utilities throughout Bangladesh.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Updated Life Cycle Assessment of Utility-Scale Solar Photovoltaic Systems Installed in the United States

Given the high deployment targets for solar photovoltaics (PV) needed to meet U.S. decarbonization goals, and the limited carbon budget remaining to limit global temperature rise, accurate accounting of the energy-use and greenhouse-gas emissions over the life-cycle of PV systems is needed. In the United States, most PV systems are large utility-scale systems which use single-axis trackers and central inverters, which are not commonly examined in existing life-cycle assessment (LCA) literature. In this study, we present a cradle-to-grave LCA of a typical silicon U.S. utility PV (UPV) installation which is consistent with the utility system features documented in the annual NREL PV system cost benchmark reports. We analyze and present results for four main metrics: cumulative energy demand (CED), greenhouse gas (GHG) emissions, energy payback time (EPBT), and carbon payback time (CPBT). We consider six primary manufacturing options: three based on an imported PV module supply chain (comparing low-carbon imports, high-carbon imports, and average imports), and three based on a potential domestic PV module supply chain (comparing low-carbon U.S. regions, high-carbon U.S. regions, and average U.S. regions). These manufacturing options were then paired with installation locations to create six main cases: low-carbon options were installed in Phoenix (Arizona), high-carbon options were installed in Seattle (Washington), and average options were installed in Fredonia (Kansas). These locations were selected to represent a range of irradiance and grid mixes in the United States, in order to illustrate the likely range of EPBTs and CPBTs possible across the United States. For all six cases, a sensitivity analysis for end-of-life (EOL) handling was explored to capture current and future management options: landfilling, partial recycling, and high-quality recycling. For the purposes of this report, the benchmark system was defined to use an average imported supply chain with partial recycling, installed in Fredonia (Kansas). CED results show ratios at or below 0.1 MJ oil-eq /MJgenerated which demonstrates efficient use of primary energy resources (below a 1:1 ratio), and represents a slight improvement over previous results in literature. GHG emissions per kWh range from 10-36 g CO 2 e, which are consistent with or lower than previous results published by NREL and IEA-PVPS. We use a graphical approach for calculating EPBT and CPBT in this report, which improves upon methods typically used in literature by accounting for non-linearity and avoiding data quality issues associated with long-term projections. EPBT was determined to vary from 0.5 to 1.2 years, with a benchmark EPBT of 0.6 years; CPBT was shown to vary from 0.8 to 20 years, with benchmark CPBT of 2.1 years, which is lower than other estimates from recent literature (typically >2 years).

14 SOLAR ENERGY↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

The University of Illinois Urbana-Champaign (UIUC) is spearheading a front-end engineering design (FEED) study of a Direct Air Capture and Utilization System (DACUS) that can remove 5,000 tonnes/yr net CO2 from ambient air, utilizing it in the production of concrete. The designed system, if built, would be larger than any currently existing DAC collector. Such carbon negative technologies are critical to meeting the goals of the DOE’s program to accelerate climate-critical technology. DAC is a promising new technology for reducing the greenhouse gas in the atmosphere but is expensive, partly due to the energy required to capture and then release CO2 during the process. By integrating CarbonCapture Technologies Inc. DAC collector at United States Steel's Gary Works and utilizing steel plant's waste heat, energy, and location so energy & transportation costs can be minimized. CarbonCapture has developed an innovative DAC system using novel adsorbents to cost- effectively capture CO2. The captured, liquified CO2 will be trucked to ready-mix concrete plants across Illinois, Indiana, & Wisconsin, where CarbonCure will inject it into concrete during the mixing process. The carbon dioxide reacts with concrete, mineralizing into calcium carbonate (CaCO3), sequestering the CO2 into the concrete, and reducing the amount of cement, the manufacturing of which is among the major sources of CO2 emissions. This FEED study demonstrates a full CO2 value chain for DACUS from industrial facilities. It also provided an opportunity to assess the impact of this holistic approach on job creation, regional economic impact, and environmental justice.

Carbon management, ccus, carbon capture, utilizati↗

Modeling Substrate Utilization, Metabolite Production, and Uranium Immobilization in Shewanella oneidensis Biofilms

In this study, we developed a two-dimensional mathematical model to predict substrate utilization and metabolite production rates in Shewanella oneidensis MR-1 biofilm in the presence and absence of uranium (U). In our model, lactate and fumarate are used as the electron donor and the electron acceptor, respectively. The model includes the production of extracellular polymeric substances (EPS). The EPS bound to the cell surface and the EPS distributed in the biofilm were considered bound EPS (bEPS) and loosely associated EPS (laEPS), respectively. COMSOL ® Multiphysics finite element analysis software was used to solve the model numerically (model file provided in the Supplementary Material). The input variables of the model were the lactate and fumarate concentrations, cell density, EPS density, half saturation constant for fumarate, and diffusion coefficients of the substrates and metabolites. To estimate unknown parameters and calibrate the model, we used a custom designed biofilm reactor placed inside a nuclear magnetic resonance (NMR) microimaging and spectroscopy system and measured substrate utilization and metabolite production rates. From these data we estimated the yield coefficients, maximum substrate utilization rate, half saturation constant for lactate, stoichiometric ratio of fumarate and acetate to lactate and stoichiometric ratio of succinate to fumarate. These parameters are critical to predicting the activity of biofilms and are not available in the literature. Lastly, the model was used to predict uranium immobilization in S. oneidensis MR-1 biofilms by considering reduction and adsorption processes in the cells and in the EPS. We found that the majority of immobilization was due to cells, and that EPS were less efficient at immobilizing U. Furthermore, most of the immobilization occurred within the top 10 µm of the biofilm. To the best of our knowledge, this research is one of the first biofilm immobilization mathematical models based on experimental observation. It has the ability to predict the relative contributions to U immobilization of laEPS, bEPS and cells.

59 BASIC BIOLOGICAL SCIENCES↗

Financial Impacts of Net-Metered Distributed PV on a Prototypical Western Utility’s Shareholders and Ratepayers

Distributed solar photovoltaic (DPV) under net-energy metering with volumetric retail electricity pricing has raised concerns among utilities and regulators about adverse financial impacts for shareholders and ratepayers. Using a pro forma financial model, we estimate the financial impacts of different DPV deployment levels on a prototypical Western U.S. investor-owned utility under a varied set of operating conditions that would be expected to affect the value of DPV. Our results show that the financial impacts on shareholders and ratepayers increase as the level of DPV deployment increases, though the magnitude is small even at high DPV penetration levels. Even rather dramatic changes in DPV value result in modest changes to shareholder and ratepayer impacts, but the impacts on the former are greater than the latter (in percentage terms). The range of financial impacts are driven by differences in the amount of incremental capital investment that is deferred, as well as the amount of incremental distribution operating expenses that are incurred. While many of the impacts appear relatively small (on a percentage basis), they demonstrate how the magnitude of impacts depend critically on utility physical, financial, and operating characteristics.

14 SOLAR ENERGY↗

Potential Energy, Demand, Emissions, and Cost Savings Distributions for Buildings in a Utility’s Service Area

Several companies, universities, and national laboratories are developing urban-scale energy modeling that allows the creation of a digital twin of buildings for the simulation and optimization of real-world, city-sized areas. Prior to simulation-based assessment, a baseline of savings for a set of utility-defined use cases was established to clarify the initial business case for specific energy efficient building technologies. In partnership with a municipal utility, 178,337 OpenStudio and EnergyPlus models of buildings in the utility’s 1400 km 2 service area were created, simulated, and assessed with measures for quantifying energy, demand, cost, and emissions reductions of each building. The method of construction and assumptions behind these models is discussed, definitions of example measures are provided, and distribution of savings across the building stock is provided under a maximum technical adoption scenario.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗