Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Quantifying the debonding of inclusions through tomography and computational homology.

This report describes a Laboratory Directed Research and Development (LDRD) project to use of synchrotron-radiation computed tomography (SRCT) data to determine the conditions and mechanisms that lead to void nucleation in rolled alloys. The Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory (LBNL) has provided SRCT data of a few specimens of 7075-T7351 aluminum plate (widely used for aerospace applications) stretched to failure, loaded in directions perpendicular and parallel to the rolling direction. The resolution of SRCT data is 900nm, which allows elucidation of the mechanisms governing void growth and coalescence. This resolution is not fine enough, however, for nucleation. We propose the use statistics and image processing techniques to obtain sub-resolution scale information from these data, and thus determine where in the specimen and when during the loading program nucleation occurs and the mechanisms that lead to it. Quantitative analysis of the tomography data, however, leads to the conclusion that the reconstruction process compromises the information obtained from the scans. Alternate, more powerful reconstruction algorithms are needed to address this problem, but those fall beyond the scope of this project.

43 PARTICLE ACCELERATORS↗

Observation of Composite Materials Using Coupled Mechanical Testing and Computed Tomography

A coupled load frame and x-ray micro-tomography unit was used to observe damage processes occurring within model composite specimens subjected to mechanical loading. These specimens consisted of two tows of glass fiber in the form of bound loops within an epoxy matrix of cylindrical form with 3-mm diameter cross-section. Computed tomography reconstruction was used to investigate internal structure of the specimens under load. This reconstruction revealed internal cracking and progressive failure in several experiments.

36 MATERIALS SCIENCE↗

Electron Tomography: A Three-Dimensional Analytic Tool for Hard and Soft Materials Research

Three-dimensional (3D) structural analysis is essential to understand the relationship between the structure and function of an object. Many analytical techniques, such as X-ray diffraction, neutron spectroscopy, and electron microscopy imaging, are used to provide structural information. Transmission electron microscopy (TEM), one of the most popular analytic tools, has been widely used for structural analysis in both physical and biological sciences for many decades, in which 3D objects are projected into two-dimensional (2D) images. In many cases, 2D-projection images are insufficient to understand the relationship between the 3D structure and the function of nanoscale objects. Electron tomography (ET) is a technique that retrieves 3D structural information from a tilt series of 2D projections, and is gradually becoming a mature technology with sub-nanometer resolution. Distinct methods to overcome sample-based limitations have been separately developed in both physical and biological science, although they share some basic concepts of ET. Here, this review discusses the common basis for 3D characterization, and specifies difficulties and solutions regarding both hard and soft materials research. It is hoped that novel solutions based on current state-of-the-art techniques for advanced applications in hybrid matter systems can be motivated. Electron tomography produces quantitative 3D reconstructions for biological and physical sciences from sets of 2D projections acquired at different tilting angles in a transmission electron microscope. Finally, state-of-the-art techniques capable of producing 3D representations such as Pt-Pd core-shell nanoparticles and IgG1 antibody molecules are reviewed.

36 MATERIALS SCIENCE↗

Computed tomography-based texture analysis of bladder cancer: differentiating urothelial carcinoma from micropapillary carcinoma

Purpose: The purpose of the study is to determine the feasibility of using computed tomography-based texture analysis (CTTA) in differentiating between urothelial carcinomas (UC) of the bladder from micropapillary carcinomas (MPC) of the bladder. Methods: Regions of interests (ROIs) of computerized tomography (CT) images of 33 MPCs and 33 UCs were manually segmented and saved. Custom MATLAB code was used to extract voxel information corresponding to the ROI. The segmented tumors were input to a pre-existing radiomics platform with a CTTA panel. A total of 58 texture metrics were extracted using four different texture extraction techniques and statistically analyzed using a Wilcoxon rank-sum test to determine the differences between UCs and MPCs. Results: Of the 58 texture metrics extracted using the gray level co-occurrence matrix (GLCM) and gray level difference matrix (GLDM), 28 texture metrics were statistically significant (p < 0.05) for differences in tumor textures and 27 texture metrics were statistically significant (p < 0.05) for peritumoral fat textures. The remaining nine metrics extracted using histogram and fast Fourier transform analyses did not show significant differences between the textures of the tumors and their peritumoral fat. Conclusions: CTTA shows that MPC have a more heterogeneous texture compared to UC. As visual discrimination of MPC from UC from clinical CT scans are difficult, results from this study suggest that tumor heterogeneity extracted using GLCM and GLDM may be a good imaging aid in segregating MPC from UC. This tool can aid clinicians in further sub-classifying bladder cancers on routine imaging, a process which has potential to alter treatment and patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Frequency-Domain Intravascular Optical Coherence Tomography of the Femoropopliteal Artery

Purpose: Optical coherence tomography (OCT) is a catheter-based imaging method that employs near-infrared light to produce high-resolution intravascular images. The authors report the safety and feasibility and illustrate common imaging findings of frequency-domain OCT (FD-OCT) imaging of the femoropopliteal artery in a series of 20 patients who underwent infrainguinal angioplasty. Methods: After crossing the lesion of interest, OCT was performed with a dextrose saline flush technique with simultaneous obstructive manual groin compression. An automatic pullback FD-OCT device was employed (each scan acquiring 54 mm of vessel lumen in 271 consecutive frames). OCT images were acquired before and after balloon dilatation and following provisional stenting if necessary and were evaluated for baseline characteristics of plaque or in-stent restenosis (ISR), vessel wall trauma after angioplasty, presence of thrombus, stent apposition, and tissue prolapse. Imaging follow-up was not included in this study's protocol. Results: Twenty-seven obstructive lesions (18 cases of de novo atherosclerosis and 9 of ISR) of the femoropopliteal artery were imaged and 148 acquisitions were analyzed in total. High-resolution intravascular OCT imaging with effective blood clearance was achieved in 93.9%. Failure was mainly attributed to preocclusive proximal lesions and/or collateral flow. Mixed features of lipid pool areas, calcium deposits, necrotic core, and fibrosis were identified in all of the imaged atherosclerotic lesions, whereas ISR was purely fibrotic. After balloon angioplasty, OCT identified extensive intimal tears in all cases and one case of severe dissection that biplane subtraction angiography failed to identify. Conclusions: Infrainguinal frequency-domain optical coherence tomography is safe and feasible and may provide intravascular high-resolution imaging of the femoropopliteal artery during infrainguinal angioplasty procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of Cone-Beam Computed Tomography and Automatic Vessel Detection Software in Emergency Transarterial Embolization

BackgroundThis study was designed to evaluate the utility of dual phase cone beam computed tomography (DP-CBCT) and automatic vessel detection (AVD) software to guide transarterial embolization (TAE) of angiographically challenging arterial bleedings in emergency settings.MethodsTwenty patients with an arterial bleeding at computed tomography angiography and an inconclusive identification of the bleeding vessel at the initial 2D angiographic series were included. Accuracy of DP-CBCT and AVD software were defined as the ability to detect the bleeding site and the culprit arterial bleeder, respectively. Technical success was defined as the correct positioning of the microcatheter using AVD software. Clinical success was defined as the successful embolization. Total volume of iodinated contrast medium and overall procedure time were registered.ResultsThe bleeding site was not detected by initial angiogram in 20 % of cases, while impossibility to identify the bleeding vessel was the reason for inclusion in the remaining cases. The bleeding site was detected by DP-CBCT in 19 of 20 (95 %) patients; in one case CBCT-CT fusion was required. AVD software identified the culprit arterial branch in 18 of 20 (90 %) cases. In two cases, vessel tracking required manual marking of the candidate arterial bleeder. Technical success was 95 %. Successful embolization was achieved in all patients. Mean contrast volume injected for each patient was 77.5 ml, and mean overall procedural time was 50 min.ConclusionsC-arm CBCT and AVD software during TAE of angiographically challenging arterial bleedings is feasible and may facilitate successful embolization. Staff training in CBCT imaging and software manipulation is necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unenhanced Cone Beam Computed Tomography and Fusion Imaging in Direct Percutaneous Sac Injection for Treatment of Type II Endoleak: Technical Note

AimTo evaluate safety, feasibility, technical success, and clinical success of direct percutaneous sac injection (DPSI) for the treatment of type II endoleaks (T2EL) using anatomical landmarks on cone beam computed tomography (CBCT) and fusion imaging (FI).Materials and MethodsEight patients with T2EL were treated with DPSI using CBCT as imaging guidance. Anatomical landmarks on unenhanced CBCT were used for referencing T2EL location in the first five patients, while FI between unenhanced CBCT and pre-procedural computed tomography angiography (CTA) was used in the remaining three patients. Embolization was performed with thrombin, glue, and ethylene–vinyl alcohol copolymer. Technical and clinical success, iodinated contrast utilization, procedural time, fluoroscopy time, and mean radiation dose were registered.ResultsDPSI was technically successful in all patients: the needle was correctly positioned at the first attempt in six patients, while in two of the first five patients the needle was repositioned once. Neither minor nor major complications were registered. Average procedural time was 45 min and the average administered iodinated contrast was 13 ml. Mean radiation dose of the procedure was 60.43 Gy cm{sup 2} and mean fluoroscopy time was 18 min. Clinical success was achieved in all patients (mean follow-up of 36 months): no sign of T2EL was reported in seven patients until last CT follow-up, while it persisted in one patient with stability of sac diameter.ConclusionsDPSI using unenhanced CBCT and FI is feasible and provides the interventional radiologist with an accurate and safe alternative to endovascular treatment with limited iodinated contrast utilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Cone-Beam Tomography and Cross-Sectional Imaging for Volumetric and Dosimetric Calculations in Resin Yttrium-90 Radioembolization

PurposeTo compare the use of cone-beam computed tomography versus contrast-enhanced computed tomography (CT) and magnetic resonance imaging (MRI) in the calculation of liver volume and planned dose for yttrium-90 radioembolization.Materials and MethodsThe study retrospectively assessed 47 consecutive patients who underwent resin Y-90 radioembolization consecutively over a 2-year period at a single center. Volume calculation software was used to determine perfused lobar liver volumes from cone-beam CT (CBCT) images obtained during mapping angiography. CBCT-derived volumes were compared with perfused lobar volume derived from contrast-enhanced CT and MRI. Nominal activities as determined by the SIR-Spheres Microspheres Activity Calculator were similarly calculated and compared using both CBCT and conventionally acquired volumes.ResultsA total of 82 hepatic lobes were assessed in 47 patients. The mean percentage difference between combined CT-MRI- and CBCT-derived calculated lobar volumes was 25.3% (p = 0.994). The mean percentage difference in calculated dose between the two methods was 21.8 ± 24.6% (p = 0.42). Combined left and right lobar CT-derived dose difference was less than 10% in 22 lobes, between 10 and 25% in 20 lobes, between 25 and 50% in 13 lobes and greater than 50% in 5 lobes. Combined left and right lobar MRI-derived dose difference was less than 10% in 11 lobes, between 10 and 25% in 7 lobes, between 25 and 50% in 2 lobes and greater than 50% in 1 lobe.ConclusionsAlthough volume measurements derived from CT/MRI did not differ significantly from those derived from CBCT, variability between the two methods led to large and unexpected differences in calculated dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Analysis of Intra-arterial Cone-Beam Versus Conventional Computed Tomography During Hepatic Arteriography for Transarterial Chemoembolization Planning

Purpose: To compare the imaging characteristics of intra-arterial cone-beam computed tomography during hepatic arteriography (CBCTHA) versus intra-arterial computed tomography during hepatic arteriography (CTHA) for intraprocedural transarterial chemoembolization (TACE) planning. Materials and Methods: This single-institution retrospective study included 144 patients (96 men, mean age 67.9 years; 48 women, mean age 62.3 years) who underwent 181 TACE sessions between January 2015 and July 2017. Intraprocedural CBCTHA (111 procedures) or CTHA (70 procedures) was performed for TACE planning. Reformatted maximum intensity projection CBCTHA and CTHA images were reviewed by two radiologists and classified using an ordinal scoring system (for tumor identification, tumor feeder vessel identification, and streaking artifact) and a binary scoring system (for the presence of breathing motion artifact and field of view encompassing the entire liver). Data were analyzed using an F test and a z-score test. Results: There were no significant differences in demographic and tumor characteristics between the CBCTHA and CTHA patient cohorts. CTHA was superior to CBCTHA for tumor identification (P < .0001), tumor feeder vessel identification (P < .05), streaking artifact (P < .0001), and field of view encompassing the entire liver (P < .0001). There was a trend toward a lower frequency of breathing motion artifact with CTHA than with CBCTHA (1.4% vs. 10%; P = .057). Conclusion: CTHA provides improved clinical relevant imaging information compared to CBCTHA for intraprocedural TACE planning. Level of Evidence: Level III, retrospective comparative study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bone marrow examination in patients with Ewing sarcoma/peripheral primitive neuroectodermal tumor without metastasis based on {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography

Ewing sarcoma/peripheral primitive neuroectodermal tumor (ES/PNET) is an aggressive bone tumor. Bone marrow aspiration and biopsy (BMAB) has been recognized as the gold standard for assessing bone marrow status. While the latest guideline suggests the need to omit bone marrow aspiration in patients with no findings on {sup 18}F-fluorodeoxyglucose positron emission tomography ({sup 18}F-FDG PET) based on one retrospective report, there is no study using {sup 18}F-FDG PET/computed tomography (CT). We retrospectively reviewed 26 consecutive, previously untreated, ES/PNET patients. We compare the results of bone marrow aspiration and biopsy (BMAB) and those of {sup 18}F-FDG PET/CT in ES/PNET patients. All of the 21 patients without metastases on {sup 18}F-FDG PET/CT had negative BMAB. The sensitivity of bone marrow involvement in bone metastases positive patients on {sup 18}F-FDG PET/CT was 75% (3/4), and the specificity was 100% (22/22). In addition to the metastatic findings on {sup 18}F-FDG PET/CT, tumor diameter, lactate dehydrogenase level at diagnosis, and the presence or absence of bone metastasis were factors related to bone marrow involvement. It may be a reasonable option to omit BMAB in ES/PNET patients with no distant metastasis based on {sup 18}F-FDG PET/CT findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intracellular trafficking of superparamagnetic iron oxide nanoparticles conjugated with TAT peptide: 3-dimensional electron tomography analysis

Highlights: Black-Right-Pointing-Pointer We study the intracellular localisation of TAT-SPIONs using 3-D electron tomography. Black-Right-Pointing-Pointer 3-D images of TAT-SPIONs in a cell are clearly shown. Black-Right-Pointing-Pointer Release of TAT-SPIONs from endocytic vesicles into the cytoplasm is clearly shown. -- Abstract: Internalisation of nanoparticles conjugated with cell penetrating peptides is a promising approach to various drug delivery applications. Cell penetrating peptides such as transactivating transcriptional activator (TAT) peptides derived from HIV-1 proteins are effective intracellular delivery vectors for a wide range of nanoparticles and pharmaceutical agents thanks to their amicable ability to enter cells and minimum cytotoxicity. Although different mechanisms of intracellular uptake and localisation have been proposed for TAT conjugated nanoparticles, it is necessary to visualise the particles on a 3-D plane in order to investigate the actual intracellular uptake and localisation. Here, we study the intracellular localisation and trafficking of TAT peptide conjugated superparamagnetic ion oxide nanoparticles (TAT-SPIONs) using 3-D electron tomography. 3-D tomograms clearly show the location of TAT-SPIONs in a cell and their slow release from the endocytic vesicles into the cytoplasm. The present methodology may well be utilised for further investigations of the behaviours of nanoparticles in cells and eventually for the development of nano drug delivery systems.

60 APPLIED LIFE SCIENCES↗

Viewing is understanding: Graphite microstructure effects on infiltrated molten salt distribution revealed by 3D neutron tomography

Molten salt infiltration in the pore network of nuclear graphite may cause unwanted changes to graphite's local structure and mechanical and thermal properties. A detailed and comprehensive understanding of molten salt intrusion (distribution across sample cross section and penetration depth) is needed to assess its effects. Here, in this work, we report on an improved methodology for the use of neutron imaging (computed tomography) to evaluate salt penetration and distribution of a wide range of graphite grades with diverse microstructures. Neutron tomography data were acquired on the same graphite sample before and after salt intrusion; the 3D reconstructed volumes were digitally co-registered and subtracted. The difference in neutron attenuation coefficient represents direct visualization of FLiNaK (LiF–NaF–KF) salt distribution in the salt-impregnated graphite samples. This improved methodology was applied to investigate the effect of exposure times (12 h and 336 h) and of graphite microstructure when exposed to FLiNaK at 750 °C and 3 bar (gauge) pressure, starting from flowing argon at near atmospheric pressure. The results show that medium-grained and fine-grained graphites evolve to equilibrium at significantly different rates: fast salt uptake in medium-grained graphites produces salt deposits throughout the volume of graphite specimens, whereas salt infiltration in fine-grained graphites is much slower and limited to exposed surfaces.

FLiNaK infiltration↗

Analysis of moisture migration in concrete at high temperature through in-situ neutron tomography

Spalling, which is a phenomenon encountered when high-performance concrete is exposed to high temperature, can lead to large economical damage and can be a major safety hazard. Moisture distribution in concrete during exposure to fire is of paramount importance for understanding the complex mechanism of this phenomenon. To capture in its fullness this mechanism, it is crucial to account for the heterogeneous nature of concrete. In this paper, the first 3D analysis of moisture distribution in concrete at high temperature through in-situ neutron tomography is presented. The world-leading flux at the Institute Laue Langevin in Grenoble, France allowed capturing one 3D scan per minute, which is sufficient to follow the fast dehydration process. The paper describes the experimental setup with the heating system and discusses in detail the framework of the neutron tomography test. Quantitative analysis showing the effect of the aggregate size on the moisture distribution is presented.

36 MATERIALS SCIENCE↗

Energy-Dispersive X-ray Spectroscopy and Atom-probe Tomography Data Quantifying Component-Ratios of Multicomponent Nano-Precipitates in Ion-Irradiated Ceria

Samples of ~1 µm films of CeO2 doped with 2 wt% Mo, 1.5 wt% Ru, 0.75 wt% Pd, 0.5 wt% Re and 0.25 wt% Rh grown with pulsed laser deposition were irradiated with I2+ ions (610°C and 730°C, 1016 and 5×1016 I2+/cm2). For selected samples post-irradiation heat treatment was conducted (900°C, 1100°C). The specimens were sectioned with focussed ion beam milling and characterized in a transmission electron microscope with energy dispesive x-ray spectroscopy, and with atom-probe tomography. Energy dispersive x-ray spectroscopy was used to obtain elemental maps showing the distribution of dopants in the specimen after exposure. Some of these maps are discussed in detail in our companion article “Formation of multicomponent alloy particles in doped ceria under I2+ ion irradiation and thermal annealing” in the Journal of Nuclear Materials [REF]. Advanced computational analysis could be used to more accurately quantify local compositions. Data is provided for additional regions of interest and one additional irradiation condition. The doped Ceria film that was heat treated at 1100 °C delaminated from the substrate in most places. Samples were extracted from the underside of a delaminated piece and analyzed with atom-probe tomography. The resulting data show Ceria and a Mo-rich particle and demonstrate that this approach is feasable in principle to study local compositions in a sample exposed to such extreme conditions.

multicomponent alloys, epsilon phase, EDS, atom pr↗

Visualization and prediction of supercritical CO 2 distribution in sandstones during drainage: An in situ synchrotron X-ray micro-computed tomography study

Pore-scale distribution of supercritical CO 2 (scCO 2 ) exerts significant control on a variety of key hydrologic as well as geochemical processes, including residual trapping and dissolution. Despite such importance, only a small number of experiments have directly characterized the three-dimensional distribution of scCO 2 in geologic materials during the invasion (drainage) process. Here, we present a study which couples dynamic high-resolution synchrotron X-ray micro-computed tomography imaging of a scCO 2 /brine system at in situ pressure/temperature conditions with quantitative pore-scale modeling to allow direct validation of a pore-scale description of scCO2 distribution. The experiment combines high-speed synchrotron radiography with tomography to characterize the brine saturated sample, the scCO 2 breakthrough process, and the partially saturated state of a sandstone sample from the Domengine Formation, a regionally extensive unit within the Sacramento Basin (California, USA). The availability of a 3D dataset allowed us to examine correlations between grains and pores morphometric parameters and the actual distribution of scCO 2 in the sample, including the examination of the role of small-scale sedimentary structure on CO2 distribution. The segmented scCO 2 /brine volume was also used to validate a simple computational model based on the local thickness concept, able to accurately simulate the distribution of scCO 2 after drainage. The same method was also used to simulate Hg capillary pressure curves with satisfactory results when compared to the measured ones. Finally, this predictive approach, requiring only a tomographic scan of the dry sample, proved to be an effective route for studying processes related to CO 2 invasion structure in geological samples at the pore scale.

3D quantitative morphometric analysis↗

Quantification of Motion of Different Thoracic Locations Using Four-Dimensional Computed Tomography: Implications for Radiotherapy Planning

Purpose: To assess the respiratory motion of different thoracic nodal locations and its dependence on the presence of enlarged nodes; to assess the respiratory motion of different parenchymal tumor locations; and to determine the appropriate margins to cover the respiratory motion of targets at these locations. Methods and Materials: We reviewed the four-dimensional computed tomography scans of 20 patients with thoracic tumors treated at our institution. The motion of four central thoracic locations (aortic arch, carina, and bilateral hila), parenchymal tumor locations (upper vs. lower, and anterior vs. middle vs. posterior thorax), and bilateral diaphragmatic domes was measured. Results: For the central thoracic locations, the largest motion was in the superoinferior (SI) dimension (>5 mm for bilateral hila and carina, but <4 mm for aortic arch). No significant difference was found in the motion of these locations in the absence or presence of enlarged nodes. For parenchymal tumors, upper tumors exhibited smaller SI motion than did lower tumors (3.7 vs. 10.4 mm, p = 0.029). Similarly, anterior tumors exhibited smaller motion than did posterior tumors in both the SI (4.0 vs. 8.0 mm, p = 0.013) and lateral (2.8 vs. 4.6 mm, p = 0.045) directions. The margins that would be needed to encompass the respiratory motion of each of the evaluated locations in 95% of patients were tabulated and range from 3.4 to 37.2 mm, depending on the location and direction. Conclusions: The results of our study have provided data for appropriate site-specific internal target volume expansion that could be useful in the absence of four-dimensional computed tomography-based treatment planning. However, generalizing the results from a small patient population requires discretion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of FDG-PET on Computed Tomography-Based Radiotherapy Planning for Locally Recurrent Nasopharyngeal Carcinoma

Purpose: Assuming F-18-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET)/computed tomography (CT) to be more accurate in representing the true disease extent than CT alone, we prospectively designed this study to evaluate how the addition of FDG-PET influences CT-based radiotherapy planning for locally recurrent nasopharyngeal carcinoma. Patients and Methods: All patients underwent FDG-PET/CT simulation scans. For each patient, the gross tumor volume (GTV) was separately delineated with or without the addition of PET information and defined as GTV{sub PET/CT} and GTV{sub CT}, respectively. Corresponding planning target volumes (PTV) were generated for the GTV{sub CT} (PTV{sub CT}) and GTV{sub PET/CT} (PTV{sub PET/CT}). Three-dimensional conformal radiotherapy plans were separately created for PTV{sub CT} and PTV{sub PET/CT}. To assess the potential geographic miss of the PET/CT-based disease in CT-based treatment planning, the size and location of the GTV{sub PET/CT}, PTV{sub PET/CT}, and PTV{sub CT} were analyzed, and the three-dimensional conformal radiotherapy plans created using the PTV{sub CT} were evaluated with the GTV{sub PET/CT} and PTV{sub PET/CT} information. Results: A total of 43 patients were enrolled in this study. Distant metastasis was found in 4 patients with the addition of the PET information. The 39 patients without distant metastasis proceeded to three-dimensional conformal radiotherapy planning. Inadequate coverage of the GTV{sub PET/CT} and PTV{sub PET/CT} by the PTV{sub CT} occurred in 7 (18%) and 20 (51%) patients, respectively. This resulted in <95% of the GTV{sub PET/CT} and PTV{sub PET/CT} receiving {>=}95% of the prescribed dose in 4 (10%) and 13 (33%) patients, respectively. Conclusions: The addition of FDG-PET information might influence CT-based radiotherapy planning for locally recurrent nasopharyngeal carcinoma by altering the definition of the target volume, with the potential to avoid a geographic miss of true disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Bladder Distension on Dose Distribution of Intracavitary Brachytherapy for Cervical Cancer: Three-Dimensional Computed Tomography Plan Evaluation

Purpose: To quantify the effect of bladder volume on the dose distribution during intracavitary brachytherapy for cervical cancer. Methods and Patients: The study was performed on 10 women with cervical cancer who underwent brachytherapy treatment. After insertion of the brachytherapy applicator, the patients were transferred to the computed tomography unit. Two sets of computed tomography slices were taken, including the pelvis, one with an empty bladder and one after the bladder was filled with saline. The target and critical organs were delineated by the radiation oncologist and checked by the expert radiologist. The radiotherapy plan was run on the Plato planning system, version 14.1, to determine the dose distributions, dose-volume histograms, and maximal dose points. The doses and organ volumes were compared with the Wilcoxon signed ranks test on a personal computer using the Statistical Package for Social Sciences, version 11.0, statistical program. Results: No significant difference regarding the dose distribution and target volumes between an empty or full bladder was observed. Bladder fullness significantly affected the dose to the small intestine, rectum, and bladder. The median of maximal doses to the small intestine was significantly greater with an empty bladder (493 vs. 284 cGy). Although dosimetry revealed lower doses for larger volumes of bladder, the median maximal dose to the bladder was significantly greater with a full bladder (993 vs. 925 cGy). The rectal doses were also affected by bladder distension. The median maximal dose was significantly lower in the distended bladder (481vs. 628 cGy). Conclusions: Bladder fullness changed the dose distributions to the bladder, rectum, and small intestine. The clinical importance of these changes is not known and an increase in the use of three-dimensional brachytherapy planning will highlight the answer to this question.

62 RADIOLOGY AND NUCLEAR MEDICINE↗