Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Particle visualization in high-power impulse magnetron sputtering. I. 2D density mapping

Time-resolved characterization of an Ar-Ti high-power impulse magnetron sputtering discharge has been performed. This paper deals with two-dimensional density mapping in the discharge volume obtained by laser-induced fluorescence imaging. The time-resolved density evolution of Ti neutrals, singly ionized Ti atoms (Ti{sup +}), and Ar metastable atoms (Ar{sup met}) in the area above the sputtered cathode is mapped for the first time in this type of discharges. The energetic characteristics of the discharge species are additionally studied by Doppler-shift laser-induced fluorescence imaging. The questions related to the propagation of both the neutral and ionized discharge particles, as well as to their spatial density distributions, are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observing the setting and hardening of cementitious materials by X-ray dark-field radiography

Novel X-ray imaging methods expand conventional attenuation-based X-ray radiography by the phase- and the dark-field contrasts. While weakly absorbing structures in the specimen can be better visualized in phase contrast, the dark-field contrast provides information about morphological sub-pixel microstructures. Here we report an application of dark-field X-ray radiography for imaging the time-resolved setting process in fresh cement. Our results demonstrate that the microstructural changes within the cement result in a decreasing dark-field signal. We quantify this imaging signal with a time-dependent dark-field scatter coefficient and show its good correlation with the compressional wave velocity. We further present images based on a pixel-wise analysis of the scattering signal and a corresponding logistic fit. These images emphasize the benefit of dark-field imaging of cementitious materials as it provides two dimensional spatial information on the processes within the sample while other established testing techniques only provide information on the bulk average.

36 MATERIALS SCIENCE↗

Visualizing the strong field–induced molecular breakup of C 60 via x-ray diffraction

Laser-driven dynamics in polyatomic molecules poses a complex many-body problem. Understanding intense light-matter interaction is crucial for steering intramolecular quantum dynamical processes. Here, we record time-resolved x-ray diffraction images of C 60 molecules during and after their interaction with intense near-infrared fields, giving direct access to structural changes of the molecules and their fragmentation in real time. Tuning the intensity of the excitation pulses, we uncover a transition from a weak-field regime of excited but stable molecules to a high-field regime dominated by Coulomb explosion. In the transition region, the molecules expand by up to 50% of their initial size within just 140 fs, with major fragmentation only setting in afterward. This work demonstrates that x-ray diffractive imaging is capable of retrieving time-resolved structural information of large molecules reshaped by intense laser fields. Laser-driven fragmentation is a first step toward observing molecular processes modified by laser fields of increasing intensity.

Schnorr, Kirsten [Paul Scherrer Inst. (PSI), Villi↗

Validation of Supervised Automated Algorithm for Fast Quantitative Evaluation of Organ Motion on Magnetic Resonance Imaging

Purpose: To validate a correlation coefficient template-matching algorithm applied to the supervised automated quantification of abdominal-pelvic organ motion captured on time-resolved magnetic resonance imaging. Methods and Materials: Magnetic resonance images of 21 patients across four anatomic sites were analyzed. Representative anatomic points of interest were chosen as surrogates for organ motion. The point of interest displacements across each image frame relative to baseline were quantified manually and through the use of a template-matching software tool, termed 'Motiontrack.' Automated and manually acquired displacement measures, as well as the standard deviation of intrafraction motion, were compared for each image frame and for each patient. Results: Discrepancies between the automated and manual displacements of {>=}2 mm were uncommon, ranging in frequency of 0-9.7% (liver and prostate, respectively). The standard deviations of intrafraction motion measured with each method correlated highly (r = 0.99). Considerable interpatient variability in organ motion was demonstrated by a wide range of standard deviations in the liver (1.4-7.5 mm), uterus (1.1-8.4 mm), and prostate gland (0.8-2.7 mm). The automated algorithm performed successfully in all patients but 1 and substantially improved efficiency compared with manual quantification techniques (5 min vs. 60-90 min). Conclusion: Supervised automated quantification of organ motion captured on magnetic resonance imaging using a correlation coefficient template-matching algorithm was efficient, accurate, and may play an important role in off-line adaptive approaches to intrafraction motion management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Luminescence methodology to determine grain-boundary, grain-interior, and surface recombination in thin-film solar cells

We determine the grain-boundary (GB) recombination velocity, S GB , and grain-interior (GI) lifetime, t GI , parameters in superstrate CdS/CdTe thin-film solar cell technology by combining cathodoluminescence (CL) spectrum imaging and time-resolved photoluminescence (TRPL) measurements. We consider critical device formation stages, including after CdTe deposition, CdCl 2 treatment, and Cu diffusion. CL image analysis methods extract GB and GI intensities and grain size for hundreds of grains per sample. Concurrently, a three-dimensional CL model is developed to simulate the GI intensity as a function of t GI , S GB , grain size, and the surface recombination velocity, S surf . TRPL measurements provide an estimate of S surf for the CL model. A fit of GI intensity vs. grain size data with the CL model gives a self-consistent and representative set of S GB and t GI values for the samples: S GB (t GI ) = 2.6 x 10 6 cm/s (68-250 ps), S GB (t GI ) = 4.1 x 10 5 cm/s (1.5-3.3 ns), and S GB (t GI ) = 5.5 x 10 5 cm/s (1.0-3.8 ns) for as-deposited, CdCl 2 -treated, and CdCl 2- A nd Cu-treated samples, respectively. Thus, we find that the CdCl2 treatment both helps to passivate GBs and significantly increase the GI lifetime. Subsequent Cu diffusion increases GB recombination slightly and has nuanced effects on the GI lifetime. Finally, as a partial check on the S GB and t GI values, they are input to a Sentaurus device model, and the simulated performance is compared to the measured performance. The methodology developed here can be applied broadly to CdTe and CdSeTe thin-film technology and to other thin-film solar cell materials including Cu(In 1-x Ga x )Se 2 , Cu 2 ZnSnS 4 , and perovskites.

14 SOLAR ENERGY↗

Stereoscopic Planar Laser-Induced Fluorescence Imaging at 500 kHz

A new measurement technique for obtaining time- and spatially-resolved image sequences in hypersonic flows is developed. Nitric-oxide planar laser-induced fluorescence (NO PLIF) has previously been used to investigate transition from laminar to turbulent flow in hypersonic boundary layers using both planar and volumetric imaging capabilities. Low flow rates of NO were typically seeded into the flow, minimally perturbing the flow. The volumetric imaging was performed at a measurement rate of 10 Hz using a thick planar laser sheet that excited NO fluorescence. The fluorescence was captured by a pair of cameras having slightly different views of the flow. Subsequent stereoscopic reconstruction of these images allowed the three-dimensional flow structures to be viewed. In the current paper, this approach has been extended to 50,000 times higher repetition rates. A laser operating at 500 kHz excites the seeded NO molecules, and a camera, synchronized with the laser and fitted with a beam-splitting assembly, acquires two separate images of the flow. The resulting stereoscopic images provide three-dimensional flow visualizations at 500 kHz for the first time. The 200 ns exposure time in each frame is fast enough to freeze the flow while the 500 kHz repetition rate is fast enough to time-resolve changes in the flow being studied. This method is applied to visualize the evolving hypersonic flow structures that propagate downstream of a discrete protuberance attached to a flat plate. The technique was demonstrated in the NASA Langley Research Center s 31-Inch Mach 10 Air Tunnel facility. Different tunnel Reynolds number conditions, NO flow rates and two different cylindrical protuberance heights were investigated. The location of the onset of flow unsteadiness, an indicator of transition, was observed to move downstream during the tunnel runs, coinciding with an increase in the model temperature.

Medford, Taylor L.↗

Measurement of electron temperature of imploded capsules at the National Ignition Facility

The electron and ion temperatures of the imploded core plasma are two of the most important metrics of inertial confinement fusion experiments. We have developed a technique for inferring electron temperatures from the contrast of x-ray images observed through a group of x-ray filters. Generally, the plasma electron temperature exhibits spatial and temporal variations, so time-averaged and time-resolved measurements are expected to yield somewhat different results. By analyzing the intensity of images observed with both a time-integrated detector (imaging plates) and a time-resolved detector (gated micro-channel plate), we found the electron temperature observed from x-ray images to be systematically higher than the ion temperature inferred from fusion neutron spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved scanning Kerr microscopy of flux beam formation in hard disk write heads

To meet growing data storage needs, the density of data stored on hard disk drives must increase. In pursuit of this aim, the magnetodynamics of the hard disk write head must be characterized and understood, particularly the process of “flux beaming.” In this study, seven different configurations of perpendicular magnetic recording (PMR) write heads were imaged using time-resolved scanning Kerr microscopy, revealing their detailed dynamic magnetic state during the write process. It was found that the precise position and number of driving coils can significantly alter the formation of flux beams during the write process. These results are applicable to the design and understanding of current PMR and next-generation heat-assisted magnetic recording devices, as well as being relevant to other magnetic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distinction of Electron Dispersion in Time-Resolved Photoemission Spectroscopy

While recent experiments provided compelling evidence for an intricate dependence of attosecond photoemission-time delays on the solid’s electronic band structure, the extent to which electronic transport and dispersion in solids can be imaged in time-resolved photoelectron (PE) spectra remains poorly understood. Emphasizing the distinction between photoemission time delays measured with two-photon, two-color interferometric spectroscopy, and transport times, we demonstrate how the effect of energy dispersion in the solid on photoemission delays can, in principle, be observed in interferometric photoemission. In this work we reveal analytically a scaling relation between the PE transport time in the solid and the observable photoemission delay and confirm this relation in numerical simulations for a model system. We trace photoemission delays to the phase difference the PE accumulates inside the solid and, in particular, predict negative photoemission delays. Based on these findings, we suggest a novel time-domain interferometric solid-state energy-momentum-dispersion imaging method.

74 ATOMIC AND MOLECULAR PHYSICS↗

Real-time Crystal Growth Visualization and Quantification by Energy-Resolved Neutron Imaging

Energy-resolved neutron imaging is investigated as a real-time diagnostic tool for visualization and in-situ measurements of "blind" processes. This technique is demonstrated for the Bridgman-type crystal growth enabling remote and direct measurements of growth parameters crucial for process optimization. The location and shape of the interface between liquid and solid phases are monitored in real-time, concurrently with the measurement of elemental distribution within the growth volume and with the identification of structural features with a ~100 μm spatial resolution. Such diagnostics can substantially reduce the development time between exploratory small scale growth of new materials and their subsequent commercial production. This technique is widely applicable and is not limited to crystal growth processes.

36 MATERIALS SCIENCE↗

Direct measurement of the transition from edge to core power coupling in a light-ion helicon source

Here, we present time-resolved measurements of an edge-to-core power transition in a light-ion (deuterium) helicon discharge in the form of infra-red camera imaging of a thin stainless steel target plate on the Proto-Material Exposure eXperiment device. The time-resolved images measure the two-dimensional distribution of power deposition in the helicon discharge. The discharge displays a mode transition characterized by a significant increase in the on-axis electron density and core power coupling, suppression of edge power coupling, and the formation of a fast-wave radial eigenmode. Although the self-consistent mechanism that drives this transition is not yet understood, the edge-to-core power transition displays characteristics that are consistent with the discharge entering a slow-wave anti-resonant regime. RF magnetic field measurements made across the plasma column, together with the power deposition results, provide direct evidence to support the suppression of the slow-wave in favor of core plasma production by the fast-wave in a light-ion helicon source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Earth as an Exoplanet. I. Time Variable Thermal Emission Using Spatially Resolved Moderate Imaging Spectroradiometer Data

Among the more than 4000 exoplanets known today, some terrestrial planets have been detected in the so-called habitable zone of their host stars and their number is expected to increase in the near future, energizing a drive to understand and interpret the eagerly awaited wealth of data to identify signs of life beyond our solar system. So far, Earth remains the best and only example of a habitable (and inhabited) world. Although, it seems extremely unlikely that any other exoplanets will be true Earth twins, it is important to explore and understand the full range of spectral signatures and variability of Earth in order to inform the design of future instruments and missions, and understand their diagnostic power as well as potential limitations. In this work we use Earth observation data collected by the MODIS instrument aboard the Aqua satellite. The complete data set comprises 15 years of thermal emission observations in the 3.66–14.40 μm range for five different locations on Earth (Amazon Rainforest, Antarctica, Arctic, Indian Ocean, and the Sahara Desert). We then determine flux levels and variations as a function of wavelength and surface type (i.e., climate zone and surface thermal properties) and investigate whether periodic signals indicating Earth’s tilted rotation axis can be detected. Our findings suggest that (1) viewing geometry plays an important role when thermal emission data is analyzed as Earth’s spectrum varies by a factor of three and more depending on the dominant surface type underneath; (2) typically strong absorption bands from CO 2 (15 μm) and O 3 (9.65 μm) are significantly less pronounced and partially absent in data from the polar regions implying that estimating correct abundance levels for these molecules might be challenging in these cases; and (3) the time-resolved thermal emission spectrum encodes information about seasons/planetary obliquity, but the significance depends on the viewing geometry and spectral band considered.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging of spatial distributions of the millimeter wave intensity by using visible continuum radiation from a discharge in a Cs–Xe mixture. Part I: Review of the method and its fundamentals

The first part of the review is presented which is dedicated to the time-resolved method of imaging and measuring the spatial distribution of the intensity of millimeter waves by using visible continuum (VC) emitted by the positive column (PC) of a dc discharge in a mixture of cesium vapor with xenon. The review focuses on the operating principles, fundamentals, and applications of this new technique. The design of the discharge tube and experimental setup used to create a wide homogeneous plasma slab with the help of the Cs–Xe discharge at a gas pressure of 45 Torr are described. The millimeter-wave effects on the plasma slab are studied experimentally. The mechanism of microwave-induced variations in the VC brightness and the causes of violation of the local relation between the VC brightness and the intensity of millimeter waves are discussed. Experiments on the imaging of the field patterns of horn antennas and quasi-optical beams demonstrate that this technique can be used for good-quality imaging of millimeter-wave beams in the entire millimeter-wavelength band. The method has a microsecond temporal resolution and a spatial resolution of about 2 mm. Energy sensitivities of about 10 μJ/cm{sup 2} in the Ka-band and about 200 μJ/cm{sup 2} in the D-band have been demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thunderstorm monitoring and lightning warning, operational applications of the Safir system

During the past years a new range of studies have been opened by the application of electromagnetic localization techniques to the field of thunderstorm remote sensing. VHF localization techniques were used in particular for the analysis of lightning discharges and gave access to time resolved 3-D images of lightning discharges within thunderclouds. Detection and localization techniques developed have been applied to the design of the SAFIR system. This development's main objective was the design of an operational system capable of assessing and warning in real time for lightning hazards and potential thunderstorm hazards. The SAFIR system main detection technique is the long range interferometric localization of thunderstorm electromagnetic activity; the system performs the localization of intracloud and cloud to ground lightning discharges and the analysis of the characteristics of the activity.

Richard, Philippe↗

Vision 20/20: Positron emission tomography in radiation therapy planning, delivery, and monitoring

Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved tumor delineation, and to assess the tumor response in follow-up investigations after or even during the course of fractionated therapy. Moreover, active research is being pursued on new tracers capable of providing different insights into tumor function, in order to identify areas of the planning volume which may require additional dosage for improved probability of tumor control. In this respect, major progresses in the next years will likely concern the development and clinical investigation of novel tracers and image processing techniques for reliable thresholding and segmentation, of treatment planning and beam delivery approaches integrating the PET imaging information, as well as improved multimodal clinical instrumentation such as PET/MR. But especially in the rapidly emerging case of ion beam therapy, the usage of PET is not only limited to the imaging of external tracers injected to the patient. In fact, a minor amount of positron emitters is formed in nuclear fragmentation reactions between the impinging ions and the tissue, bearing useful information for confirmation of the delivered treatment during or after therapeutic irradiation. Different implementations of unconventional PET imaging for therapy monitoring are currently being investigated clinically, and major ongoing research aims at new dedicated detector technologies and at challenging applications such as real-time imaging and time-resolved in vivo verification of motion compensated beam delivery. This paper provides an overview of the different areas of application of PET in radiation oncology and discusses the most promising perspectives in the years to come for radiation therapy planning, delivery, and monitoring.

60 APPLIED LIFE SCIENCES↗

Deep learning-based temporal deconvolution for photon time-of-flight distribution retrieval

The acquisition of the time of flight (ToF) of photons has found numerous applications in the biomedical field. Over the last decades, a few strategies have been proposed to deconvolve the temporal instrument response function (IRF) that distorts the experimental time-resolved data. However, these methods require burdensome computational strategies and regularization terms to mitigate noise contributions. Herein, we propose a deep learning model specifically to perform the deconvolution task in fluorescence lifetime imaging (FLI). The model is trained and validated with representative simulated FLI data with the goal of retrieving the true photon ToF distribution. Its performance and robustness are validated with well-controlled in vitro experiments using three time-resolved imaging modalities with markedly different temporal IRFs. The model aptitude is further established with in vivo preclinical investigation. Overall, these in vitro and in vivo validations demonstrate the flexibility and accuracy of deep learning model-based deconvolution in time-resolved FLI and diffuse optical imaging.

Pandey, Vikas (ORCID:0000000154771095)↗