Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal state”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A robust high sensitivity scanning thermal probe for simultaneous microscale thermal and thermoelectric property mapping

Scanning Thermal Microscopy (SThM) provides efficient thermal property measurement with micro- or nanoscale spatial resolution. However, the sensitivity and accuracy of state-of-the-art thermal probes have been limited by excessive thermal contact resistance between the probe and sample. Introduced herein is a robust thermal microprobe that can increase the probe-sample contact force by more than two orders of magnitude, thereby reducing the probe-sample thermal contact resistance by as much as 96% and increasing measurement sensitivity by more than 240% compared to a commercial thermal probe with the same dimensions and measurement principle. The relationship between the probe-sample thermal contact resistance, thermal exchange radius, and sample thermal conductivity is determined experimentally. Simultaneous measurement of thermal conductivity and Seebeck coefficient with unprecedented sensitivity is demonstrated using the enhanced scanning thermal microprobe on samples of an extended range of thermal conductivity up to 18 W/m K, increasing the range of samples applicable to SThM when compared to the conventional commercial probe with diminished measurement sensitivity above ~10 W/m K. The probe is further demonstrated by simultaneously mapping thermal conductivity and Seebeck coefficient as a function of depth from the irradiated surface of an ion-irradiated bulk nanostructured thermoelectric material. In addition to enabling microscale thermal conductivity and Seebeck coefficient measurement of materials previously not applicable to SThM, the probe can also facilitate high-throughput characterization of combinatorial materials to aid the rapid discovery of compositions and processing conditions that yield highly desired thermal and thermoelectric properties.

36 MATERIALS SCIENCE↗

FAST-1.0: A Computer Code for Thermal-Mechanical Nuclear Fuel Analysis under Steady-state and Transients: Developed under NQA-1-2017

Fuel Analysis under Steady-state and Transients (FAST) is the US Nuclear Regulatory Commission (NRC)’s computer code that calculates the steady-state and transient response of nuclear reactor fuel rods during long-term in-reactor burnup, anticipated operational occurrences (AOOs), design basis accidents (DBAs), and dry storage conditions. The code calculates the temperature, pressure, and deformation of a fuel rod as functions of time-dependent fuel rod power and coolant boundary conditions. The phenomena modeled by the code include: heat conduction through the fuel and other materials, heat transfer from the cladding-to-coolant, cladding elastic and plastic deformation, including creep, fuel-cladding mechanical interaction, fission gas release from the fuel, rod internal pressure and void volume, and cladding oxidation. The code contains necessary material and coolant properties, as well as clad-to-coolant heattransfer correlations, for normal operation through postulated accidents for today’s US-based light water reactor (LWR) fuel designs. FAST-1.0 also contains preliminary materials and models for new LWR fuel concepts, such as accident tolerant fuel (ATF), and non-LWR fuel concepts such as metallic fuels for sodium fast reactors (SFRs). FAST has been developed for use on Windows and Linux operating systems. This document describes FAST-1.0, which is the first official version of this code. This document is one of a series of documents on FAST; the other documents detail the material properties used by FAST as well as its integral assessment to experiments and commercial data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FAST-1.1: A Computer Code for Thermal-Mechanical Nuclear Fuel Analysis under Steady-state and Transients (Developed under NQA-1-2017)

Fuel Analysis under Steady-state and Transients (FAST) is the U.S. Nuclear Regulatory Commission (NRC)’s computer code that calculates the steady-state and transient response of nuclear reactor fuel rods during long-term in-reactor burnup, anticipated operational occurrences (AOOs), design basis accidents (DBAs), and dry storage conditions. The code calculates the temperature, pressure, and deformation of a fuel rod as functions of time-dependent fuel rod power and coolant boundary conditions. The phenomena modeled by the code include: * heat conduction through the fuel and other materials * heat transfer from the cladding-to-coolant * cladding elastic and plastic deformation, including creep * fuel-cladding mechanical interaction * fission gas release from the fuel * rod internal pressure and void volume * cladding oxidation The code contains necessary material and coolant properties, as well as clad-to-coolant heat transfer correlations, for normal operation through postulated accidents and AOOs for today’s U.S.-based light water reactor (LWR) fuel designs. FAST-1.1 also contains preliminary materials and models for new LWR fuel concepts, such as accident tolerant fuel (ATF), and non-LWR fuel concepts such as metallic fuels for sodium fast reactors (SFRs). FAST has been developed for use on Windows and Linux operating systems. This document describes FAST-1.1 and is one of a series of documents on the code; the other documents detail the material properties used by FAST as well as its integral assessment to experiments and commercial data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FAST-1.2: A Computer Code for Thermal-Mechanical Nuclear Fuel Analysis under Steady-state and Transients

Fuel Analysis under Steady-state and Transients (FAST) is the U.S. Nuclear Regulatory Commission (NRC)’s computer code that calculates the steady-state and transient response of nuclear reactor fuel rods during long-term in-reactor burnup, anticipated operational occurrences (AOOs), design basis accidents (DBAs), and dry storage conditions. The code calculates the temperature, pressure, and deformation of a fuel rod as functions of time-dependent fuel rod power and coolant boundary conditions. The phenomena modeled by the code include: • heat conduction through the fuel and other materials • heat transfer from the cladding-to-coolant • cladding elastic and plastic deformation, including creep • fuel-cladding mechanical interaction • fission gas release from the fuel • rod internal pressure and void volume • cladding oxidation The code contains necessary material and coolant properties, as well as clad-to-coolant heat-transfer correlations, for normal operation through postulated accidents and AOOs for today’s U.S.-based light water reactor (LWR) fuel designs. FAST-1.2 also contains preliminary materials and models for new LWR fuel concepts, such as accident tolerant fuel (ATF), and non-LWR fuel concepts such as metallic fuels for sodium fast reactors (SFRs). FAST has been developed for use on Windows and Linux operating systems. This document describes FAST-1.2 and is one of a series of documents on the code; the other documents detail the material properties used by FAST as well as its integral assessment to experiments and commercial data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FAST-1.2.2: A Computer Code for Thermal-Mechanical Nuclear Fuel Analysis under Steady-state and Transients

Fuel Analysis under Steady-state and Transients (FAST) is the U.S. Nuclear Regulatory Commission (NRC)’s computer code that calculates the steady-state and transient response of nuclear reactor fuel rods during long-term in-reactor burnup, anticipated operational occurrences (AOOs), design basis accidents (DBAs), and dry storage conditions. The code calculates the temperature, pressure, and deformation of a fuel rod as functions of time-dependent fuel rod power and coolant boundary conditions. The phenomena modeled by the code include heat conduction through the fuel and other materials, heat transfer from the cladding-to-coolant, cladding elastic and plastic deformation (including creep), fuel-cladding mechanical interaction, fission gas release from the fuel, rod internal pressure, void volume, and cladding oxidation. The code contains necessary material and coolant properties, as well as clad-to-coolant heat transfer correlations, for normal operation through postulated accidents and AOOs for today’s U.S.-based light water reactor (LWR) fuel designs. FAST-1.2.2 also contains preliminary materials and models for new LWR fuel concepts, such as accident tolerant fuel (ATF), and non-LWR fuel concepts such as metallic fuels for sodium fast reactors (SFRs). FAST has been developed for use on Windows and Linux operating systems. This document describes FAST-1.2.2 and is one of a series of documents on the code; the other documents detail the material properties used by FAST as well as its integral assessment to experiments and commercial data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding how minority relativistic electron populations may dominate charge state balance and radiative cooling of a post-thermal quench tokamak plasma

Minority relativistic electron populations can occur in a range of complex plasmas. Of specific interest is when runaway electrons form among the presence of high-atomic-number ion species in a tokamak plasma discharge. It has been recently demonstrated that ion charge state distributions and radiation losses at low bulk electron temperatures can be dominated by relativistic electrons, even though their density is orders of magnitude lower. Furthermore, this was attributed to the relativistic enhancement of electron impact inelastic cross sections. In this work, we provide a closer inspection of the atomic physics underpinning this effect. We also demonstrate the consequences of runaway enhanced scattering on post-disruption tokamak fusion discharges with neon and argon impurities present. Effects on charge state distributions, radiation and spectral characteristics, and reduced-order modeling considerations are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Critical roles of pores and moisture in sustainable nanocellulose-based super-thermal insulators

In a recent report in Matter, Bergström and co-workers describe a novel thermal transport behavior that subverts this assumption of porous materials. In their work, the authors describe a nanocellulose-based foam that features ultrahigh porosity (> 99.6%) and aligned µm-scale pores (10–100 µm) whose radial thermal conductivity (i.e., perpendicular to the pore alignment) is close to that of free air in the dry state. Furthermore, the radial thermal conductivity of the cellulose-based foam can be reduced to ~14 mW/(m·K) when the relative humidity is ~35%. Super-thermal insulators, which demonstrate a thermal conductivity below that of stationary air (~ 25 mW/(m·K), 20 ºC, 1.0 atm), are needed to minimize heat loss in various applications (e.g., buildings, thermal energy storage tanks, cold chain packaging, etc.) to mitigate the energy crisis and reduce carbon emissions. Introducing pores into a material is a facile and effective way to achieve low thermal conductivity as pores can suppress thermal transport through solids by reducing the cross-sectional area and increasing the tortuosity of the heat transfer pathway. In porous structures there are two kinds of pores: open and closed. While increased porosity can reduce heat conduction through solids with an open porous structure, the improved gas conduction creates a competing effect that simultaneously elevates the heat transfer. Therefore, the thermal conductivity of a material with µm-scale open pores is usually larger than that of stationary air. Reducing the pore size to less than the mean free path of air (~ 70 nm, 20 ºC, 1.0 atm) can effectively reduce gas conduction, enabling the material to achieve a thermal conductivity below that of stationary air. However, high cost of the nanosized raw materials and time-consuming fabrication processes limit the large-scale applications of nanoporous thermal insulators. Meanwhile, closed pores can block heat transport only through the continuous gas phase. As a result, the thermal conductivity of a closed porous structure can theoretically be much smaller than that of stationary air if the solid conduction can also be suppressed by (1) lowering the solid content of the material, (2) reducing the thermal conductivity of the building blocks of the material, and/or (3) increasing interfacial thermal resistance between neighboring building blocks. Most processes used to generate porous structures (e.g., supercritical drying, freeze drying) involve a solvent that escapes the material. Therefore, it is difficult to create pores and isolate them simultaneously, preventing the fabrication of super-thermal insulators with closed pores.

36 MATERIALS SCIENCE↗

A perspective on the electro-thermal co-design of ultra-wide bandgap lateral devices

Fundamental research and development of ultra-wide bandgap (UWBG) semiconductor devices are under way to realize next-generation power conversion and wireless communication systems. Devices based on aluminum gallium nitride (AlxGa1-xN, x is the Al composition), ..beta..-phase gallium oxide (..beta..-Ga2O3), and diamond give promise to the development of power switching devices and radio frequency power amplifiers with higher performance and efficiency than commercial wide bandgap semiconductor devices based on gallium nitride (GaN) and silicon carbide (SiC). However, one of the most critical challenges for the successful deployment of UWBG device technologies is to overcome adverse thermal effects that impact the device performance and reliability. Overheating of UWBG devices originates from the projected high power density operation and poor intrinsic thermal properties of AlxGa1-xN and ..beta..-Ga2O3. This Perspective delineates the need and process for the "electro-thermal co-design" of laterally configured UWBG electronic devices and provides a comprehensive review of current state-of-the-art thermal characterization methods, device thermal modeling practices, and both device- and package-level thermal management solutions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Getting a THUMP from a WIMP

Producing an acceptable thermal relic abundance of dark matter with masses >> 10 2 TeV is a challenge. We propose a novel mechanism where GeV-scale states establish a tiny thermal relic abundance for dark matter, which is later promoted to ultra massive status by a very light scalar. We refer to this dark matter as a THermal Ultra Massive Particle (THUMP). Direct detection of THUMPs can be naturally expected due to large scattering cross sections mediated by low mass states that couple THUMPs to the Standard Model. Our model generically leads to signals for the associated GeV-scale states at accelerator experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Behavior of Oval-Twisted Helical Tube Heat Exchanger: Numerical Study with RELAP5-3D

Convective heat transfer characteristics and theoretical thermal stress behaviors are numerically calculated using RELAP5-3D for the helical-coiled once-through steam generator (H-OTSG) and the novel heat exchanger design known as the oval-twisted helically coiled heat exchanger (OTHCHX) under (1) fluctuating wall temperature conditions, (2) square-wave pulsating flow conditions, and (3) the combined effects of fluctuating wall temperature and square-wave pulsating flow conditions. Heat transfer coefficient models for the H-OTSG and OTHCHX were developed based on existing data and implemented into RELAP5-3D, successfully capturing the N⁢uavg behavior within 8% to 10% of the reported data. Under fluctuating wall temperature conditions, the OTHCHX displayed higher N⁢u avg behavior than the H-OTSG. As 𝑓 increased, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ decreased. The $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ was higher for the OTHCHX than for the H-OTSG under fluctuating wall temperature conditions. Under pulsating flow conditions, the H-OTSG and OTHCHX displayed much higher 𝑁⁢𝑢 𝑎𝑣𝑔 than under constant flow conditions. The H-OTSG displayed a higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ over the OTHCHX. Under combined fluctuating wall temperature and pulsating flow conditions, the augmented heat transfer behavior from the pulsating flow was counteracted by the wall temperature fluctuations, producing slightly higher 𝑁⁢𝑢 𝑎𝑣𝑔 over constant wall temperature, constant flow conditions, but much lower than only constant pulsating flow under constant wall temperature conditions. The effects of simultaneous wall temperature fluctuations and square-wave pulsating flow caused higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ than that of only wall temperature fluctuations or pulsating flow. As the Reynolds number (Re) increased, $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ increased. However, when 𝑓=𝑓$_{\dot{m}}$, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ showed decreasing values as Re increased. In conclusion, the results indicate that thermal-fluid resonance can help mitigate thermal stresses.

Thermal stress↗

Mana and thermalization: Probing the feasibility of near-Clifford Hamiltonian simulation

Quantum hydrodynamics is the emergent classical dynamics governing transport of conserved quantities in generic strongly interacting quantum systems. Here, recent matrix product operator methods [1,2] have made simulations of quantum hydrodynamics in 1+1D tractable, but they do not naturally generalize to 2+1D or higher, and they offer limited guidance as to the difficulty of simulations on quantum computers. Near-Clifford simulation algorithms are not limited to one dimension, and future error-corrected quantum computers will likely be bottlenecked by non-Clifford operations. We therefore investigate the non-Clifford resource requirements for simulation of quantum hydrodynamics using mana, a resource theory of non-Clifford operations. For infinite-temperature starting states, we find that the mana of subsystems quickly approaches zero, while for starting states with energy above some threshold the mana approaches a nonzero value. Surprisingly, in each case the finite-time mana is governed by the subsystem entropy, not the thermal state mana; we argue that this is because mana is a sensitive diagnostic of finite-time deviations from canonical typicality.

1-dimensional spin chains↗

Melting down a tetraquark: D*D(*) interactions and T c c ( 3875 ) + in a hot environment

We discuss the modification of the properties of the tetraquark-like and its heavy quark spin partner, immersed in a hot bath of pions. We consider these exotic states as purely isoscalar DD* and D*D* S-wave bound states, respectively. Finite temperature effects are incorporated through the D and D* state-of-the-art thermal spectral functions calculated in [G. Montana et al., Phys. Rev. D, 102 (2020) 096020], using the imaginary-time formalism. We find important modifications of the DD* and D*D* scattering amplitudes already for MeV, and show that the hot-bath lineshapes of these tetraquark-like states strongly depend on their Weinberg molecular content. We find that the thermal and spectral functions change more rapidly with temperature for high molecular probabilities P0. For large values of P0, the widths significantly increase with temperature, leading to the melting of these exotic states for temperatures larger than 80 MeV. For small molecular components, the changes in the spectral functions of these states due to temperature become significantly less important. All these results show that any future experimental determination of the D(*)D* scattering amplitudes at finite temperature will provide valuable insights into the molecular content of the and exotics.

Montesinos, V. (ORCID:0000000261862777)↗

HFIR LEU High Density Silicide Dispersion Optimized Design Steady-State Heat Transfer Analyses

Steady-state heat transfer simulations of the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR) with the low-enriched uranium (LEU) high-density silicide dispersion Optimized fuel design were performed to support comprehensive performance and safety metric studies concerning this design. The LEU Optimized design operates at 95 MW to maintain HFIR’s current highly enriched uranium (HEU) core performance level at 85 MW. Full cycle Mode 1 full flow Case 1 (inlet temperature), Case 2 (flux-to-flow), and Case 3 (inlet pressure) safety limit analyses were performed to assess the margins to critical heat flux. Under the prescribed conditions, this LEU design meets the safety limit and limiting control setting requirements outlined in HFIR’s documented safety analysis; however, the safety margins are less than those for the 85 MW HEU core, and several assumptions were made where fuel fabrication and qualification data are currently lacking for the silicide fuel design. Effects of changes to pertinent fuel fabrication assumptions and uncertainty factors on thermal safety margins were also evaluated, showing that the margins are sensitive to many of these parameters. Power and pressure perturbations were also performed, indicating that significant steady-state thermal margins could be gained by increasing the coolant inlet pressure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hourly dynamic line ratings for existing transmission across the contiguous United States (preliminary results) [Slides]

The thermal rating of a transmission line depends on the rate at which heat generated by current flow through the line can be dissipated into the environment by convective and radiative cooling, keeping the conductor below a maximum operating temperature. Static or seasonal line ratings assume nearly-worst-case weather conditions (high ambient air temperature, high solar irradiance, and low wind speed), resulting in a low risk of "overrating" a line (i.e., allowing more current to flow than the line is designed for) but a high fraction of time when the line is "underrated" (i.e., able to flow more current while staying below the maximum temperature). Dynamic transmission line ratings (DLR) use real-time measurements of weather conditions, line sag, or line temperature to determine the thermal rating of transmission lines at hourly or higher time resolution, allowing for increased ratings during some (cold, windy, and/or dark) periods and correcting for overrating during other (hot, calm, and/or sunny) periods. Many studies have explored the benefits of DLR, but typically for small collections of transmission lines under a limited sample of weather conditions, leaving open the question of how widely applicable the benefits of DLR might be over diverse geographies and weather conditions. Here, we combine geospatial data on tens of thousands of transmission line routes across the contiguous United States with high-resolution hourly historical weather data for 2007-2013 to estimate the impact of DLR and other weather-adjusted rating systems. We compare static and dynamic line ratings to intermediate ratings adjusted by ambient temperature, day/night irradiance, clear-sky irradiance, and/or measured irradiance, illustrating the benefits of incorporating progressively more detailed weather data into the calculated line ratings. Moving from nighttime-adjusted ratings to clear-sky-adjusted ratings provides more benefit than moving from clear-sky-adjusted ratings to measured-irradiance-adjusted ratings. Depending on the assumed static windspeed for irradiance-adjusted-ratings, DLR either corrects for overrated hours or provides substantially increased ratings in the majority of hours on the majority of lines.

14 SOLAR ENERGY↗

Physics vs structure: A systematic benchmark of learning strategies for multi-zone building thermal dynamics

Recent advances in physics-informed and data-driven machine learning promise improved thermal models for advanced building control, yet there is limited quantitative evidence on when added physics structure and architectural complexity are beneficial. Here, this work presents a systematic benchmark of five representative system identification methods for modeling multi-zone building thermal dynamics: linear state-space models, multi-layer perceptrons, neural state-space models, neural ordinary differential equations, and physically-consistent neural networks. The methods are evaluated across multiple data regimes and zone coupling strategies. Using a high-fidelity multi-zone commercial building emulator, we examine short-term and long-term prediction accuracy, computational efficiency, and ease of development. Our results reveal critical trade-offs between prediction performance, model complexity, and physical consistency. We demonstrate that decoupled, nonlinear black-box models consistently outperform coupled physics-constrained architectures in both predictive accuracy and out-of-distribution robustness in majority of the test cases for the building type considered in the study. Our findings quantify the cost of complexity in building thermal modeling and provide concrete, actionable, scenario-based guidelines for selecting model classes for control-oriented applications.

Building thermal modeling↗