Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Investigation of Gas Turbine Internal Cooling Using Supercritical CO 2 —Effect of Surface Roughness and Channel Aspect Ratio

In this paper, an experimental and numerical investigation of internal cooling channels with rib turbulators is presented with sCO 2 as the working fluid at process conditions (pressure-20.7 MPa and temperature up to 150 °C). The effect of channel aspect ratio up to 2:1 on thermal-hydraulic performance is explored in additively manufactured rectangular channels and square channels, both with and without 60 deg ribs on the top and bottom sides. The Wilson-plot method is employed to experimentally measure channel-averaged Nusselt number over a Reynolds number range up to 370,000. The friction factor is calculated from pressure drop and mass flow rate and additionally, the overall thermal performance factor (TPF) is reported. A companion computational fluid dynamics (CFD) simulation is performed for the rib turbulated cooling configurations reported in the experiments using the Reynolds average Navier–Stokes-based turbulence model. The objective of the numerical study is to gain insight into the local heat transfer augmentation in the ribbed channels as a result of varying the aspect ratio, channel configuration (square versus rectangular), operating conditions (Reynolds number) and the surface roughness, an inherent outcome of the additive manufacturing process. Surface roughness is simulated using sand grain roughness height (K S ) calculated from the experimental data, and a comparison is presented with the corresponding channel configuration with varying surface roughness heights starting from smooth surfaces (K S = 0). Experimental results indicate that the heat transfer augmentation is negligible in the rectangular channels with ribs on the long side compared to the square channel. However, it is enhanced by 60% in comparison to placing ribs on the shorter side. The TPF remains constant at around 1 for the entire range of Reynolds numbers consistent with prior work at the National Energy Technology Laboratory (NETL). Here, the simulation results highlight that increased surface roughness can have a favorable considerable influence on Nusselt number and overall thermal performance enhancement.

42 ENGINEERING↗

Thermal design analysis for SuperTruck II lithium-titanate battery pack

Here, this paper presents a systematic thermal management analysis for a new lithium-titanate-oxide battery pack to be installed in a SuperTruck II, Class 8 hybrid truck. The authors investigate the feasibility of mounting the battery pack inside the vehicle and air-cooling it with fans supplying conditioned air from the cabin. Moreover, the cells within each module are to be immersed in a heat-transfer fluid to improve temperature homogeneity. A multi-stage thermal analysis is performed to ensure adequate thermal regulation of the battery under the proposed design, considering installation and operational constraints. The authors perform thermal and electrical characterization tests on a single cell. Results inform the development of computational fluid dynamics models of the cells, modules, and pack. Module-level analysis shows that the cell temperatures can be maintained below their upper operational limit of 55 °C with module wall-to-air heat transfer coefficients between 10 and 20 Wm -2 K -1 . Pack-level analysis of distinct configurations determines effective airflow paths for adequate heat transfer and delivers a final battery pack design that achieves sufficient cooling and temperature uniformity. A reduced-order electrothermal model is developed to rapidly predict the transient battery performance and to develop a temperature control strategy.

25 ENERGY STORAGE↗

Evaluation of the Thermal and Moisture Performance of Insulating Shades

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak heating and cooling loads of a home. Over the past 20 years, residential window attachment retrofit technologies have been developed that significantly increase the number of options available to home builders, homeowners, and utilities when considering upgrades of overall window performance. Within the interior window attachments category, honeycomb cellular shades typically have the highest R-values because of their layered or concentric designs. During the winter when the window is fully covered, however, the added insulation reduces the amount of warm indoor air that reaches the window surface, thereby lowering the temperature of the window glass and frame and increasing the potential for condensation to collect on the interior surface of the window. The degree to which this potential is realized depends on the indoor and outdoor conditions as well as the overall thermal resistance of the window and the shades. To examine the condensation buildup potential on the interior surface of the window and the conditions under which this occurs, this report describes experimental research conducted by Pacific Northwest National Laboratory in collaboration with Hunter Douglas, using a a controlled environmental test chamber at the Hunter Douglas facility in Broomfield, Colorado. The results will be used to inform the Attachments Energy Rating Council, which provides energy performance information on all rated window attachments products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of Pulsed Thermal Tomography Imaging with Machine Learning-Based Classification of Defects in Additively Manufactured Structures

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures non-destructively. Pulsed Thermal Tomography Imaging (PTT) provides a capability for non-destructive evaluation (NDE) of subsurface defects in arbitrary size structures. The PTT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PTT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. Following initial qualification of an AM component for deployment in a nuclear reactor, a PTT system can also be used for in-service nondestructive evaluation (NDE) applications. In this report, we describe recent progress in enhancing PTT capabilities in detecting and visualizing microscopic defects in metallic specimens. The thermal tomography (TT) algorithm obtains depth reconstructions of spatial effusivity from the data cube of sequentially recorded surface temperatures. However, interpretation of TT images is non-trivial because of blurring of images with increasing depth. To address this challenge, we have developed a deep learning convolutional neural network (CNN) to classify size and orientation subsurface defects in simulated TT images. CNN is trained on a database of TT images created for a set of simulated metallic structures with elliptical subsurface voids. Test of CNN performance demonstrate the ability to classify radii and angular orientation of subsurface defects in TT images. In addition, we have shown that CNN trained on elliptical defects is capable of classifying irregular-shaped defects obtained from scanning electron microscopy (SEM) of stainless steel sections printed with LPBF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal and hydraulic performance of volumetrically heated triply periodic minimal surface heaters

Advanced heat transfer surfaces, mainly Triply Periodic Minimal Surfaces (TPMSs) have great potential to increase heat transfer performance over traditional heat transfer surfaces due to their tortuous flow path and higher surface area-volume ratio. The emergence of additive manufacturing of nuclear fuel motivates experimental investigation of such advanced geometries in the context of a nuclear reactor core. Here, this study employed a novel method to explore the performance of gyroid and diamond TPMS geometries. Volumetrically heated heaters were additively manufactured from conductive polymer filament, and airflow was used to simulate the convective heat transfer from the core within a nuclear reactor. The mass flow and volumetric generation rates were varied, local Nusselt number correlations were obtained using embedded thermocouples to measure the solid and fluid temperature, and friction factor correlations were developed using differential pressure measurements. The gyroid TPMS presented a friction factor 1.5 times higher than the diamond TPMS and 90 times that of the rod bundle. TPMS geometries showed Nusselt numbers 8–10 times higher than that of the rod bundle, also maintaining colder internal temperatures, which suggested that they could sustain 250–275 % higher power density than the rod bundle for a given centerline temperature. Hence, having the potential to greatly increase the safety margins and power output of a nuclear reactor core with similar volume.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Off-design operation and performance of pumped thermal energy storage

In this article, we describe off-design models and control strategies for a Pumped Thermal Energy Storage (PTES) system that uses liquid thermal energy storage: specifically molten salt for hot storage and methanol for cold storage. Off-design conditions arise when load-following, or due to variations in storage tank temperatures or ambient temperatures. We propose a control strategy that uses inventory control to manage the mass flow rate in the thermodynamic cycles, which facilitates load following. We also propose a control strategy for the storage fluid mass flow rates, which are varied to ensure the molten salt is maintained at its design temperature. This maximizes efficiency and minimizes problems with salt freezing or degradation. The cold storage fluid mass flow rate is varied so that the cold tanks have the same state-of-charge as the hot tanks. This leads to variations in cold fluid temperature, but these variations are shown to be acceptably small (e.g. 7.5% increase), and this control method is shown to be simpler and more efficient than an alternative strategy where tanks become unbalanced. The ambient temperature and storage tank temperatures are moved ±50 °C from the design values and the impact on power, duration, and tank temperatures is quantified. Results demonstrate that the proposed control strategy is stable and self-correcting - that is, storage temperatures converge on stable values after two-to-three charge-discharge cycles. When inputs return to design values, the system returns to its design point after two charge-discharge cycles. We also demonstrate that inventory control enables delivery of the target power output even when off-design conditions exist that would normally reduce the power output.

25 ENERGY STORAGE↗

Energy Use in Quantum Data Centers: Scaling the Impact of Computer Architecture, Qubit Performance, Size, and Thermal Parameters

As quantum computers increase in size, the total energy used by a quantum data center, including the cooling, will become a greater concern. The cooling requirements of quantum computers, which operate at temperatures near absolute zero, are determined by computing system parameters, including the number and type of physical qubits, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. When combined with thermal system parameters such as cooling efficiency and cryostat heat transfer, the total energy use can be determined using a first-principles energy model. These models show that cooling of quantum computers differs in two fundamental ways from conventional data centers: (1) the energy required for cooling is much greater than the energy required for computation, and (2) the cooling loads are sensitive to the computational architecture. The temperature requirements for different qubit types can change energy requirements by orders of magnitude. Power use and computational power, as quantified by quantum volume, are analytically correlated. Approaches are identified for minimizing energy use in integrated quantum systems relative to computational power. Furthermore, designing a sustainable quantum computer will require both efficient cooling and system design that minimizes cooling requirements.

97 MATHEMATICS AND COMPUTING↗

Analysis of convection heat transfer on multiscale rough superhydrophobic and liquid infused surfaces

Multiscale rough superhydrophobic or slippery liquid infused porous surfaces have gained much interest in recent years for their improved transport phenomena properties. While there have been several studies on drag reduction and condensation on non-wetting surfaces, convection heat transfer that is important in many thermal and thermochemical applications has not been addressed systematically. Here, this article utilizes a fractal description of rough surface topographies to develop analytical models for the Nusselt number and the thermal hydraulic factor for fluid flow and heat transfer inside a cylinder with non-wetting surfaces. For air-infused superhydrophobic surfaces, the model considers the dynamic stability of the air/fluid interface in the asperities. Using the analytical formulations and the stability criteria, systematic studies are presented on the effects of the fractal surface parameters, cylinder radius and Reynolds number on the convective heat transfer characteristics, from which surface texture design maps are developed for maximizing the convection heat transfer. It is shown that multiscale non-wetting surfaces are most effective in the range of lower Reynolds number and small cylinder radius for achieving the best convective heat transfer and thermal hydraulic performance. Applying the models to actual non-wetting surface topographies fabricated using electrodeposition and chemical etching, it is shown that contrary to prevailing notion, superhydrophobicity, characterized by the highest contact angles, does not always lead to the maximum convective heat transfer performance, and that under certain fluid flow conditions, hydrophobic surfaces may offer a greater thermal performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal-Fluid and Thermal-Structural Response of the T-Tube Modular Divertor to Spatiotemporally Varying Heat Loads

Tungsten (W) is the leading candidate for divertor target plates because of its high melting point (>3000°C), thermal conductivity, and ultimate tensile stress. While W and its alloys are the only solid materials that can survive the high heat fluxes incident on the divertor, W’s low-ductility high ductile-to-brittle transition temperature of ~600°C and relatively low recrystallization temperature (RT) of ~1300°C pose structural (among other) challenges. The objective of this work is to estimate the thermal-fluid and thermal-structural performance of the helium (He)-cooled T-tube divertor, which was originally developed by the Advanced Reactor Innovation and Evaluation Study (ARIES) using numerical simulations. Here, predictions of temperature distributions across the plasma-facing structural component and surface pressures from computational fluid dynamics simulations are used to determine stress distributions using commercial structural finite element modeling software over a range of fusion-relevant conditions. The maximum allowable incident heat fluxes are determined based on the temperature limits imposed by the ITER elastic Structural Design Criteria for In-vessel Components (SDC-IC) and the maximum RT over a range of He mass flow rates and presented in the form of performance design charts. Our recent work found that thermal- structural criteria accounting for the low ductility of W in a finger-type modular divertor constrain the maximum incident heat fluxes to values well below the ITER specifications, and those based on considering only the RT demonstrate that integrated thermal-fluid and elastic structural performance evaluation are required for accurate assessment of divertor performance. This novel analysis of the T-tube considers how nonuniform and transient incident heat fluxes affect its thermal-fluid and thermal-structural performance, as well as the effect of volumetric heating, which can be as great as 27% of the power incident on the divertor surface. The W tile of the T-tube, with its relatively large plasma-facing area of ~15 cm 2 , will likely experience significant spatial variations in incident heat flux. This work therefore assesses whether steady-state incident heat flux profiles with a peak of 10 MW/m 2 and maximum heat flux gradients of 200 MW/m 2 per m exceed the structural limits imposed by the ITER elastic SDC-IC and the maximum RT over a range of fusion-relevant conditions. The effect of transient heat fluxes typical of plasma detachment and reattachment from the target plate due, for example, to gas injection are also evaluated

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Λ polarization from vortex rings as the medium response for jet thermalization

We performed a systematic study on the formation of vorticity rings as the process for jet thermalization in the medium created in high-energy nuclear collisions. In this work, we expanded our previous analysis to a more realistic framework by considering noncentral events and fluctuations in the initial condition. We simulate the formation and evolution of the flow vortex structure in a relativistic viscous hydrodynamic model and study the sensitivity of the proposed “ring observable” (ℛ$^{𝑡}_{Λ}$) that can be measured experimentally through the polarization of Λ hyperons. We show that this observable is robust with respect to fluctuating initial conditions to capture the jet-induced vortex flow signal and further study its dependence on different model parameters, such as the jet's velocity, position, the fluid's shear viscosity, and the collision centrality. The proposed observable is associated with the formation of vorticity in a quark-gluon plasma, showing that the measurement of particle polarization can be a powerful tool to probe different properties of jet-medium interactions and to understand better the polarization induced by the transverse and longitudinal expansions of the medium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Large Bore Rabbit Capsules in Support of BWR Cladding Irradiations in HFIR

The High Flux Isotope Reactor (HFIR) is an ideal tool for materials irradiation testing because of its intense steady-state neutron flux. Many programs take advantage of HFIR’s central flux trap for irradiation experiments using capsules, also known as rabbits, to support advanced materials development and reactor design. The facility that makes up the HFIR flux trap has recently undergone a design change that increases the HFIR primary coolant volumetric flow rate by removing restrictions in the system. As a result, the usable cross-sectional area within the facility increased, opening the door to increase the cross-sectional area of the rabbit capsules that fill the facility. This report documents a new large-diameter rabbit housing that increases the usable volume within the rabbit capsule by 22.6%. However, challenges arise with increasing the capsule size, such as establishing a new maximum capsule operating pressure and determining the thermal-hydraulic characteristics. This report addresses those challenges with previously adopted HFIR safety methods. The rupture pressure of the rabbit housings is demonstrated while verifying that capsule swelling during and after rupture will not block coolant flow. Then, a safety factor is applied to ascertain an administrative operating pressure. Additionally, the thermal-hydraulic performance of the HFIR facility filled with large-diameter rabbit capsules is shown to not violate previously determined safety criteria. Next, heat transfer coefficients are determined for use in design calculations. Furthermore, this report gives an example of internal configurations for the new, larger rabbit capsules that use relevant boiling water reactor (BWR) cladding geometry. Finally, this report documents an example thermal design performance for a rabbit capsule containing six gauge-curved tensile tube specimens. The thermal performance gives predicted temperature distributions within the capsule and shows the expected temperature of the passive thermometers for post-irradiation temperature comparisons.

99 GENERAL AND MISCELLANEOUS↗