Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Solar energy system performance evaluation: Seasonal report for Contemporary-Manchester, Manchester, New Hampshire

The operational and thermal performance of the solar energy system, Contemporary-Manchester, is described. The system was designed by Contemporary Systems Incorporated to provide space heating and domestic hot water preheating for a three story dwelling located on the New Hampshire Vocational Technical College campus, Manchester, New Hampshire. The net fossil energy savings for the period from March, 1979 to February, 1980 was 14.52 million Btu. However, the performance of the system must be degraded due to the fact that the building was unoccupied throughout the data assessment and analysis period. The unoccupied status prevented the normal adjustment of heating and ventilating controls for maintenance of comfort levels within the building. This lack of occupancy also prevented the typical family hot water usage, which would have allowed for more realistic evaluation of the hot water subsystem.

Source record↗

Final cryogenic performance report for the NASA Cosmic Background Explorer (COBE)

The cryogenic operation of NASA's Cosmic Background Explorer (COBE) ended on September 21, 1990, with the depletion of the liquid helium cryogen. The COBE had successfully completed more than 10 months of dewar and instrument operation. We report on the cryogenic performance of the COBE dewar and of the two cryogenic instruments throughout the mission lifetime. We discuss the steady state dewar performance, and the dewar and instrument response to a variety of transient thermal phenomena, including external radiation (from the earth and the sun) and instrument power variation. We present the effectiveness of using approximate mass gauging techniques in determining the liquid helium content. Finally we discuss the dewar behavior during the depletion of the helium, and the expected thermal performance of the dewar cryogen tank and the cryogenic instruments as they approach final thermal equilibrium.

Volz, S. M.↗

Analytic and experimental evaluation of shadow shields and their support members for thermal control of space vehicles

The thermal performance of shadow shields, and their support struts, for the thermal protection of cryogenic propellants in a simulated deep-space environment was investigated analytically and experimentally. Very low overall heat-transfer rates were obtained when highly reflective aluminized Mylar shadow shields were used. The thermal interactions between the shields and support struts were investigated with fair to good agreement between the analysis and experimental data. The exterior surface of both fiberglass and titanium struts was coated to reduce the heat input into the test tank. The vacuum level inside the test facility strongly influenced the heat-transfer rates.

Boyle, R. J.↗

Apparatus for measurement of thermal conductivity of insulation systems subjected to extreme temperature differences

Advanced aerospace designs require thermal insulation systems which are consistent with cryogenic fluids, high thermal loads, and design restrictions such as weight and volume. To evaluate the thermal performance of these insulating systems, an apparatus capable of measuring thermal conductivity using extreme temperature differences (27 to 1100 K) is being developed. This system is described along with estimates of precision and accuracy in selected operating conditions. Preliminary data are presented.

Dube, W. P.↗

Effect of Cyclic Aeroconvective Heating on Flexible Thermal Insulations

This paper describes the effect of cyclic aeroconvective heating on the thermal performance of ceramic flexible insulations considered for potential use as thermal protection systems or thermal insulations for future hypersonic vehicles such as the Reusable Launch Vehicles (RLV's) and other applications where structures require thermal protection from severe heating. The thermal response of these materials after exposure to cyclic aeroconvective heating from a plasma arc is described. The thermal insulations evaluated were Composite Flexible Blanket Insulations composed of an outer layer of aluminoborosilicate fabric and alumina insulation. The insulations were evaluated with and without a high emissivity coating. These insulations were exposed to the plasma arc stream for nine minutes reaching surface temperatures of 1150 C and a heat flux of 10.5 W/sq cm. Insulations were exposed three, six, or nine times in order to demonstrate reusability and to determine the effect oi coatings on the surface durability of these insulations. Test results demonstrated the capability of these insulations to protect either composite or metallic structures from high heating environments. It is shown that high emittance coatings reduce backface temperatures. The durability of these insulations when impacted at low velocities was also demonstrated. The interaction of the coatings with the ceramic fibers was characterized. An analytical thermal model was utilized to correlate experimental thermal test results with calculated values.

Kourtides, Demetrius A.↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

ABSTRACT: Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Thermal Management Key Performance Parameter Development and System Analysis for the SUSAN Electrofan Aircraft

A set of key performance parameters (KPPs) for thermal management system (TMS) components was developed for use in system sizing and analysis. These KPPs were defined at three different levels of performance corresponding to different ranges of Technology Readiness Levels. KPP values were determined based on a large dataset that includes analysis and testing data from literature, NASA-funded research, and commercial product datasheets. These KPPs were then used to perform a TMS sizing and analysis of the SUbsonic Single Aft eNgine (SUSAN) aircraft. Total TMS mass, power consumption, and drag is quantified at each KPP level, showing decreasing trends as the level of technology improves.

thermal management↗

Effects of Heat Transfer Coefficient Variation on Nuclear Thermal Propulsion Engine Performance

A physics-based Nuclear Thermal Propulsion (NTP) Testing Reference Design (TRD) power balance model was coded in Simulink to investigate engine performance for various design and parameter modifications. Since the primary mode of heat transfer in NTP engines is convective, the convective heat transfer coefficient (HTC) is a key parameter that requires accurate representation. The industry standard Westinghouse correlation has an uncertainty of ±20% which was investigated in this study. The results showed that a 20% decrease in the HTC led to a 4.14% increase in maximum fuel temperature while a 20% decrease in the HTC led to a 1.81% decrease in maximum fuel temperature suggesting that narrowing the uncertainty of this correlation through experimental work would be a critical step in the development of NTP engines. Furthermore, a maximum fuel temperature relationship with specific impulse was developed for the TRD engine which showed potential engine operation between specific impulse values of 715 and 900 seconds with minimal changes to the engine design. This graph could be useful for high level vehicle performance estimations for fuel types with different maximum operating temperatures.

Heat Transfer Coefficient↗

Single-node orbit analsyis with radiation heat transfer only

The steady-state temperature of a single node which dissipates energy by radiation only is discussed for a nontime varying thermal environment. Relationships are developed to illustrate how shields can be utilized to represent a louver system. A computer program is presented which can assess periodic temperature characteristics of a single node in a time varying thermal environment having energy dissipation by radiation only. The computer program performs thermal orbital analysis for five combinations of plate, shields, and louvers.

Peoples, J. A.↗

DEXTER: A one-dimensional code for calculating thermionic performance of long converters

A versatile code is described for computing the coupled thermionic electric-thermal performance of long thermionic converters in which the temperature and voltage variations cannot be neglected. The code is capable of accounting for a variety of external electrical connection schemes, coolant flow paths and converter failures by partial shorting. Example problem solutions are included along with a user's manual.

Sawyer, C. D.↗

Thermal Vacuum Testing of a Modified COTS Camera for Lunar Environments

The primary objective of this study was to simulate lunar thermal environments to qualify a modified Commercial-Off-The-Shelf (COTS) camera for potential flight applications. A comprehensive testing regimen was developed, including both vacuum and thermal vacuum testing. The tests subjected the camera to temperatures corresponding to expected extrema, and thermal performance was recorded throughout the process. The testing demonstrated that both the camera and its thermal protection systems were able to maintain operational functionality under most of the simulated conditions. The results of the testing indicate that the implemented thermal protection system is effective for the expected lunar environments. Despite the decrease in operational time in comparison with terrestrial usage, the camera's overall performance supports its suitability for use in both flight and lunar missions.

Thermal↗

Dexter - A one-dimensional code for calculating thermionic performance of long converters.

This paper describes a versatile code for computing the coupled thermionic electric-thermal performance of long thermionic converters in which the temperature and voltage variations cannot be neglected. The code is capable of accounting for a variety of external electrical connection schemes, coolant flow paths and converter failures by partial shorting. Example problem solutions are given.

Sawyer, C. D.↗

Thermal design of the Viking lander capsule

During the summer of 1975, two Viking spacecraft will be launched toward Mars, each consisting of a lander capsule coupled to an orbiter. About a year later, the orbiters will go into orbit around Mars and then the landers will descend to begin operation on the surface of Mars for 90 day missions. This paper describes the thermal control aspects of the lander capsule design and operation. The paper presents the thermal control requirements, the design philosophy and approach to solving these thermal problems, and then a description of the resulting thermal control subsystem design features. It concludes with a summary of the vehicle thermal performance characteristics as determined from both analysis and system tests under simulated thermal environments.

Tracey, T. R.↗