Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

San José Urban Development: Quantifying Canopy Cover and Land Surface Temperature in San José to Identify Future Tree Planting Sites

The urban heat island effect refers to the phenomenon of substantially increased temperatures in urban areas compared to their surrounding suburban or rural counterparts. The City of San José’s Department of Parks, Recreation and Neighborhood Services (PRNS) and Department of Transportation (DOT) work to mitigate the UHI effect through urban forestry initiatives. The PRNS and DOT partnered with NASA DEVELOP to identify areas in need of tree plantings. We examined land surface temperature (LST) throughout the city using data from the Thermal Infrared Sensor (TIRS) and TIRS-2 on NASA’s Landsat 8 and 9 satellites from 2013 to 2024. We also assessed canopy cover in parks using LiDAR data collected in 2020 for the United States Geological Survey’s 3D Elevation Program, and measured vegetation greenness using the Normalized Difference Vegetation Index (NDVI) with PlanetScope imagery from 2018 to 2024. We evaluated social and environmental factors that influence the distribution of heat event impacts by creating a heat vulnerability index. We found that heat is concentrated in urban areas and that poor vegetation health is associated with high LST. We also found that socially vulnerable communities are disproportionately located in areas of high environmental risk. These analyses allow the partners to prioritize tree plantings in parks near areas of high social and environmental risk. We determined that Earth observations can be used to inform urban forestry decision making, but because methodologies for using LiDAR to assess canopy cover vary greatly, it is difficult to make comparisons across different canopy cover assessments.

land surface temperature↗

Microfabricated fuel heating value monitoring device

A microfabricated fuel heating value monitoring device comprises a microfabricated gas chromatography column in combination with a catalytic microcalorimeter. The microcalorimeter can comprise a reference thermal conductivity sensor to provide diagnostics and surety. Using microfabrication techniques, the device can be manufactured in production quantities at a low per-unit cost. The microfabricated fuel heating value monitoring device enables continuous calorimetric determination of the heating value of natural gas with a 1 minute analysis time and 1.5 minute cycle time using air as a carrier gas. This device has applications in remote natural gas mining stations, pipeline switching and metering stations, turbine generators, and other industrial user sites. For gas pipelines, the device can improve gas quality during transfer and blending, and provide accurate financial accounting. For industrial end users, the device can provide continuous feedback of physical gas properties to improve combustion efficiency during use.

47 OTHER INSTRUMENTATION↗

Implications of Weak Link Effects on Thermal Characteristics of Transition-Edge Sensors

Weak link behavior in transition-edge sensor (TES) devices creates the need for a more careful characterization of a device's thermal characteristics through its transition. This is particularly true for small TESs where a small change in the measurement current results in large changes in temperature. A highly current-dependent transition shape makes accurate thermal characterization of the TES parameters through the transition challenging. To accurately interpret measurements, especially complex impedance, it is crucial to know the temperature-dependent thermal conductance, G(T), and heat capacity, C(T), at each point through the transition. We will present data illustrating these effects and discuss how we overcome the challenges that are present in accurately determining G and T from IV curves. We will also show how these weak link effects vary with TES size.

Bailey, Catherine↗

Implications of Weak Link Effects on Thermal Characteristics of Transition-Edge Sensors

Weak link behavior in transition-edge sensor (TES) microcalorimeters creates the need for a more careful characterization of a device's thermal characteristics through its transition. This is particularly true for small TESs where a small change in the bias current results in large changes in effective transition temperature. To correctly interpret measurements, especially complex impedance, it is crucial to know the temperature-dependent thermal conductance, G(T), and heat capacity, C(T), at each point through the transition. We present data illustrating these effects and discuss how we overcome the challenges that are present in accurately determining G and T from I-V curves. We also show how these weak link effects vary wi.th TES size. Additionally, we use this improVed understanding of G(T) to determine that, for these TES microcalorimeters. Kaptiza boundary resistance dominates the G of devices with absorbers while the electron-phonon coupling also needs to be considered when determining G for devices without absorbers

Bailey, C. N.↗

SERFE Thermal Performance Results

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. The Suit Water Membrance Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal loop technologies was developed and has been under test in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack since November of 2020. In addition to the SWME, The SWME EXPRESS Rack Flight Experiment (SERFE) contains several technology demonstrations from the xEMU project and has been demonstrating their performance in micro-gravity and over an extended duration. In addition to the SWME, these include two dissimilar water pumps, custom check valves, custom bypass relieve valves, a custom thermal control valve, development pressure and temperature sensors, and the Thermal Loop Controller. This paper presents thermal and fluids testing results of the system as a whole and of key components.

SERFE↗

SERFE PLSS Component Lessons Learned from ISS

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is under development to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. The Suit Water Membrane Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal control loop (TCL) technologies was developed and tested in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack from November of 2020 to August of 2022. In addition to the SWME, the SWME EXPRESS Rack Flight Experiment (SERFE) contains several technologies from the xEMU project and demonstrated their performance in micro-gravity and over an extended duration. These included two dissimilar water pumps, custom check valves, custom bypass relieve valves, a custom thermal control valve, development pressure and temperature sensors, and the thermal loop controller. This paper presents PLSS component lessons learned after return of the SERFE flight unit in August of 2022. The SERFE team took the flight unit apart and handed hardware components over to hardware owners to see how parts of the TCL managed after almost 2 years on the ISS and 25 simulated EVAs (Exploration Extravehicular Activity) on orbit. The team performed inspection, testing, and analysis and provided lessons learned on PLSS components for NASA’s prototype spacesuit. This analysis included how well SWME maintained its heat rejection capability, as well as looked at the robustness of the other TCL hardware.

SERFE↗

SERFE PLSS Component Lessons Learned from ISS

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is under development to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. The Suit Water Membrane Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal control loop (TCL) technologies was developed and tested in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack from November of 2020 to August of 2022. In addition to the SWME, the SWME EXPRESS Rack Flight Experiment (SERFE) contains several technologies from the xEMU project and demonstrated their performance in micro-gravity and over an extended duration. These included two dissimilar water pumps, custom check valves, custom bypass relieve valves, a custom thermal control valve, development pressure and temperature sensors, and the thermal loop controller. This paper presents PLSS component lessons learned after return of the SERFE flight unit in August of 2022. The SERFE team took the flight unit apart and handed hardware components over to hardware owners to see how parts of the TCL managed after almost 2 years on the ISS and 25 simulated EVAs (Exploration Extravehicular Activity) on orbit. The team performed inspection, testing, and analysis and provided lessons learned on PLSS components for NASA’s prototype spacesuit. This analysis included how well SWME maintained its heat rejection capability, as well as looked at the robustness of the other TCL hardware.

SERFE↗

Electronically scanned multichannel pressure transducer system for cryogenic environments

Research into the application of custom doped piezoresistive silicon pressure sensors has led to a multichannel pressure sensor design that will operate accurately and reliably at cryogenic temperatures. The thermal effects upon multichannel pressure sensors are mapped by thermal calibrations and are represented by sets of nth order coefficients specific to each sensor. The thermal offset and sensitivity variations are corrected by computer algorithms which scan the sensors, recall correction coefficients from thermally induced sensor variations, and apply these to correct the sensor's output measurement uncertainty to within 0.5 percent of full scale output for combined offset and sensitivity. A prototype sensor system has been fabricated, and performance test data are presented.

Chapman, John J.↗

Thermophysical analysis of II-VI semiconductors by PPE calorimetry and lock-in thermography

An accurate determination of thermophysical properties such as thermal diffusivity, thermal effusivity and thermal conductivity is extremely important for characterization and quality assurance of semiconductors. Thermal diffusivity and effusivity of some binary semiconductors have been investigated. Two experimental techniques were used: a contact technique (PPE calorimetry) and a non contact technique (lock-in thermography). When working with PPE, in the back (BPPE) configuration and in the thermally thick regim of the pyroelectric sensor, we can get the thermal diffusivity of the sample by performing a scanning of the excitation frequency of radiation. Thermal effusivity is obtained in front configuration (sensor directly irradiated and sample in back position) by performing a thickness scan of a coupling fluid. By using the lock-in thermography technique, the thermal diffusivity of the sample is obtained from the phase image. The results obtained by the two techniques are in good agreement. Nevertheless, for the determination of thermal diffusivity, lock-in thermography is preferred.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal effects of an ICL-based mid-infrared CH 4 sensor within a wide atmospheric temperature range

Here, thermal effects of an interband cascade laser (ICL) based mid-infrared methane (CH 4 ) sensor that uses long-path absorption spectroscopy were studied. The sensor performance in the laboratory at a constant temperature of ~ 25°C was measured for 5 hours and its Allan deviation was ~ 2 ppbv with a 1 s averaging time. A LabVIEW-based simulation program was developed to study thermal effects on infrared absorption and a temperature compensation technique was developed to control such effects. An environmental test chamber was employed to investigate thermal effects that occur in the sensor system with variation of the test chamber temperature between 10 and 30°C. The thermal response of the sensor in a laboratory setting was observed using a 2.1 ppm CH 4 standard gas sample. indoor/outdoor CH 4 measurements were conducted to evaluate the sensor performance within a wide atmospheric temperature range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Background and Lunar Neutron Populations Detected by LEND and Average Concentration of Near-Surface Hydrogen near the Moon's Poles

Neutron flux measurements by the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) enable quantifying hydrogen-bearing volatiles in the lunar surface from orbit. Accurately determining hydrogen abundance requires discriminating between the instrument background detection rate and the population of lunar-sourced neutrons that are sensitive to surficial hydrogen. We have investigated the detection rate for lunar and non-lunar (spacecraft-sourced) neutrons in LEND by modeling maps of measured count rate in three LEND detector systems using linear combinations of maps compiled from LEND detectors and from the Lunar Prospector Neutron Spectrometer. We find that 30% of the global-average 24.926 +/- 0.020 neutron counts per second (cps) detected by the LEND STN3 thermal-energy neutron sensor are lunar-sourced neutrons in the thermal energy range (E < 0.4 eV), 65% are lunar-sourced neutrons in the epithermal and fast energy range (E > 0.4 eV), and 5% are from spacecraft-sourced background signal. In the SETN epithermal neutron detector, 90% of the 10.622 +/- 0.002 neutron detections per second are consistent with a lunar source of epithermal and fast neutrons combined (E > 0.4 eV), with 3% due to lunar-sourced thermal neutron leakage into the detector (E < 0.4 eV), and background signal accounting for 7% of total detections. Background signal due to spacecraft-derived neutrons is substantial in the CSETN collimated detector system, accounting for 57% of the global average detection rate of 5.082 +/- 0.001 cps, greater than the 48% estimated from cruise-phase data. Lunar-sourced epithermal and fast neutrons account for 43% of detected neutrons, including neutrons in collimation as well as neutrons that penetrate the collimator wall to reach the detector. We estimate a lower limit of 17% of lunar-sourced neutrons detected by CSETN are epithermal neutrons in collimation (0.37 cps), with an upper limit estimate of 54 +/- 11% of lunar-sourced neutrons received in collimation, or 1.2 +/- 0.2 cps global average. The pole-to-equator contrast ratio in epithermal and high-energy epithermal neutron flux indicates that the average concentration of hydrogen in the polar regolith above 80deg north or south latitude is ∼105 ppmw (parts per million by weight), or 0.095 +/- 0.01 wt% water-equivalent hydrogen. Above 88deg north or south, the concentration increases to ∼140 ppmw, or 0.13 +/- 0.02 wt% water-equivalent hydrogen. The similar pattern of neutron flux suppression at both poles suggests that hydrogen concentration generally increases nearer the pole and is not closely associated with a specific feature such as Shackleton Crater at the lunar south pole that has no northern counterpart. Epithermal neutron flux decreases with increasing latitude outside the polar regions, consistent with surface hydration that increases with latitude if that hydration extends to ∼13-40 cm into the surface.

T A Livengood↗

Background and Lunar Neutron Populations Detected by LEND and Average Concentration of Near-Surface Hydrogen near the Moon's Poles

Neutron flux measurements by the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) enable quantifying hydrogen-bearing volatiles in the lunar surface from orbit. Accurately determining hydrogen abundance requires discriminating between the instrument background detection rate and the population of lunar-sourced neutrons that are sensitive to surficial hydrogen. We have investigated the detection rate for lunar and non-lunar (spacecraft-sourced) neutrons in LEND by modeling maps of measured count rate in three LEND detector systems using linear combinations of maps compiled from LEND detectors and from the Lunar Prospector Neutron Spectrometer. We find that 30% of the global-average 24.926 0.020 neutron counts per second (cps) detected by the LEND STN3 thermal-energy neutron sensor are lunar-sourced neutrons in the thermal energy range (E < 0.4 eV), 65% are lunar-sourced neutrons in the epithermal and fast energy range (E > 0.4 eV), and 5% are from spacecraft-sourced background signal. In the SETN epithermal neutron detector, 90% of the 10.622 0.002 neutron detections per second are consistent with a lunar source of epithermal and fast neutrons combined (E > 0.4 eV), with 3% due to lunar-sourced thermal neutron leakage into the detector (E < 0.4 eV), and background signal accounting for 7% of total detections. Background signal due to spacecraft-derived neutrons is substantial in the CSETN collimated detector system, accounting for 57% of the global average detection rate of 5.082 0.001 cps, greater than the 48% estimated from cruise-phase data. Lunar-sourced epithermal and fast neutrons account for 43% of detected neutrons, including neutrons in collimation as well as neutrons that penetrate the collimator wall to reach the detector. We estimate a lower limit of 17% of lunar-sourced neutrons detected by CSETN are epithermal neutrons in collimation (0.37 cps), with an upper limit estimate of 54 11% of lunar-sourced neutrons received in collimation, or 1.2 0.2 cps global average. The pole-to-equator contrast ratio inepithermal and high-energy epithermal neutron flux indicates that the average concentration of hydrogen in the polar regolith above 80 north or south latitude is ~105 ppmw (parts per million by weight), or 0.095 0.01 wt% water-equivalent hydrogen. Above 88 north or south, the concentration increases to ~140 ppmw, or 0.13 0.02 wt% water-equivalent hydrogen. The similar pattern of neutron flux suppression at both poles suggests that hydrogen concentration generally increases nearer the pole and is not closely associated with a specific feature such as Shackleton Crater at the lunar south pole that has no northern counterpart. Epithermal neutron flux decreases with increasing latitude outside the polar regions, consistent with surface hydration that increases with latitude if that hydration extends to ~13-40 cm into the surface.

Livengood, Timothy A.↗