1,119 records · Page 22

Hubble Space Telescope nickel-hydrogen battery testing: An update

The Marshall Space Flight Center (MSFC) began testing the HST Ni-H2 Six Battery Test and the 'Flight Spare Battery' Tests approximately one year before the launch of the HST. These tests are operated and reported on by the MSFC, but are managed and funded by Goddard Space Flight Center in direct support of the HST program. The HST Ni-H2 batteries are built from Eagle Picher RNH-90-3 cells. The HST EPS (electrical power system) is a direct energy transfer power system. The HST Ni-H2 Six Battery Test is a breadboard of the HST EPS. The batteries in the test are composed of test module cells and packaged into three battery modules identical to the flight modules. This test is the HST EPS testbed. The 'Flight Spare Battery' Test is a simulation of one of the six battery channels on the HST. The cells in the test are from the flight spare lot of cells, which are the same lot of cells that three of the six HST flight batteries are made from. This test is the battery life test for the HST program.

Whitt, Thomas H.

Laser Beam Welding Benchmark Experiments Performed in Reduced Gravity and Vacuum

Laser beam welding (LBW) is affected by the extreme temperatures, reduced pressure, and reduced gravity present in space environments. Gravity and pressure especially influence its melt pool and solidification dynamics. A compact, modular vacuum chamber adaptable to flight platforms from parabolic to orbital currently hosts an experiment to investigate the combined influence of reduced gravity and pressure on LBW. A swappable cartridge contains a rotating platen on which customizable workpieces can be welded under vacuum, greatly increasing experimental throughput. Instrumentation includes weld and thermal cameras observing the process, thermocouples placed on workpieces, accelerometers, and vacuum sensors. Experimental data gathered during the welding process will be combined with post-flight nondestructive evaluation, metallography, and mechanical testing to provide validation datasets for computational modeling. Phase I of this effort involves a parabolic flight campaign in low gravity while an anticipated Phase II would proceed to in-space demonstration to access extended duration microgravity.

in-space welding

Parametric tests of a 40-Ah bipolar nickel-hydrogen battery

A series of tests were performed to characterize battery performance relating to certain operating parameters which include charge current, discharge current, temperature, and pressure. The parameters were varied to confirm battery design concepts and to determine optimal operating conditions.

Cataldo, R. L.

Mercury Corrosion Loop Testing Program

The Mercury Corrosion Loop Testing Program continued through the second quarter. Materials to be tested in the 10 forced-convection test loops were selected; the materials are: Haynes 25, 9 Cr-1Mo alloy clad with Type 316 stainless steel, AM 350 stainless steel, and columbium (niobium) clad with Type 316 stainless steel. The eight-test-cell facility was completed and all utilities were installed. Pneumatic and electronic instrumentation for all test cells was installed and calibrated. Fabrication was initiated on the first four Haynes 25 loops. The first loop was 85% assembled at the end of the quarter. A centrifugal pump made from Type 316 stainless steel was tested; bearing modifications were made to improve operation.

Corrosion

Material Properties and Modeling of Room Temperature Vulcanizing Silicone

Room Temperature Vulcanizing silicone (RTV) is a high-temperature adhesive that has successfully been used as a gap-filler between Thermal Protection System (TPS) tiles for heatshields on numerous missions. It is also used to bond instrumentation plugs such as temperature and pressure sensors into the heatshields. While RTV has been traditionally assumed to be a non-porous and non-ablating material, numerous experiments have shown that RTV pyrolyzes and becomes highly porous as it is heated. Heating RTV has also shown swelling, or intumescence, which can pose unique problems that lead to roughness induced boundary-layer transition, surface oxide formation and contamination of heat shield sensors. Therefore, it is crucial to understand and model the intumescence phenomenon of RTV. As data for RTV material properties is limited, the first step in modeling RTV is to collect material properties such as pyrolysis mass-loss, microstructure change, virgin and char porosity, etc. which was performed in our initial study. Additionally, thermomechanical properties such as Young’s modulus and Poisson ratio are required for modeling the intumescence of RTV, which were taken from literature and the coefficient of thermal expansion was collected using in-situ heating and Micro Computed Tomography (µ-CT) in previous studies. Finally, numerous other properties such as pyrolysis gas properties, virgin and char thermal conductivity and specific heat were compiled from previous experiments and literature into a material database that can be used for simulations. In Porous Material Analysis Toolbox based on OpenFOAM (PATO) [4], structural mechanics coupled with material response was used for simulating the intumescence of RTV as it is heated. However, since the permeability of the material is very low, the pyrolysis gas creates an internal pressure build-up as the material is being heated, significantly contributing to the deformation of the material. To correctly characterize this phenomenon, additional physics models were implemented into PATO's stress analysis solver, and results were compared with RTV dilatometry test data as a preliminary verification case. Future work will include experiments of RTV at the Plasmatron X facility and the in-situ heating cell with µ-CT, and improvement of simulation tools to more accurately model RTV intumescence.

PATO

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator

EMU Ag-Zn battery wet-life extension test

The Extravehicular Mobility Unit (EMU) silver/zinc (Ag/Zn) battery is an 11 cell battery of approximately 30 AH. The Ag/Zn battery is comprised of two 4-cell monoblocks and one 3-cell monoblock. A discussion of a wet-life extension test performed on the battery is given in viewgraph form.

Bragg, Bobby J.

AstroDOME: Standardized, Mass-Produceable, Small NASA Astrophysics Observatories for Big Missions

NASA’s Goddard Space Flight Center is investigating the use of small, commercial off the shelf (COTS) spacecraft to enable breakthrough astrophysics research at radically reduced cost over previous generations of missions. This paper will focus on the Mission Systems perspective of this investigation. It will cover the spacecraft to instrument interface, and lessons learned in early concept payload development. Low-cost COTS spacecraft have proliferated in the last ~5 years. They represent an order of magnitude reduction in the cost of spacecraft bus development and acquisition. They are enabled by the advent of low-cost smallsat launch options in the immediately preceding years, and are seeded by recent distributed and disaggregated missions in other sectors such as telecommunications megaconstellations (e.g. Starlink, OneWeb, Project Kuiper) and ongoing Space Development Agency (SDA) developments. Our study was tasked with developing a standardized, mass-produceable, astrophysics payload which is reconfigurable to different wavelength bands while maintaining a single optics bench design, and a standardized mechanical, electrical, data, and thermal interface to the spacecraft bus, and which may be reconfigured to multiple COTS spacecraft offerings. In this paper we will discuss lessons learned from our case study. We will also present identified keys to mission success for performing cutting edge astrophysics observations while taking advantage of economies of scale with a disaggregated, standardized architecture.

Matthew Marcus

Battery life test using reconditioning

A discussion is presented on nickel cadmium battery life tests using reconditioning and some comparative tests not using reconditioning. The discussion is aimed at the program application part of the testing. The goals of the program were to get an increased utilization out of the battery system in geosynchronous orbit. An attempt was made to push the depth of discharge operation up around 80 to 85 percent and the intent with the reconditioning program was to extend this type of utilization out towards a 10-year life and attune the voltage regulation.

Sparks, R. H.