Uncertainty of Personnel Dosimetry Systems Using Performance Data Testing
While accreditation programs require a study of uncertainty for each dosimeter model for which accreditation is sought (Torres 2005, DOE 1986), no one method is specifically recommended by accrediting bodies. Typically, the methods used to determine uncertainty have included the partial differentiation method described in the U.S. Guide to Uncertainty in Measurements (ANSI 1997) or the use of Monte Carlo techniques and probability distribution functions to generate simulated dose results. Each of these techniques has particular strengths and should be employed when the areas of uncertainty are required to be understood in detail. However, the uncertainty of dosimeter results can also be determined using a Model II One-Way Analysis of Variance technique and accreditation testing data (Cummings and Flood 2010). The strengths of this method are (1) the method is based in robust and well-accepted statistical techniques; (2) the method is straightforward and easily applied to dose algorithms, which are so complex as to render the use of other methods unwieldy; and (3) the method uses dosimeter performance data obtained during accreditation. The general method and criteria of inclusion of radiation types and fields are discussed.