Establishing Maximal Core Excess Reactivity Envelope for TREAT Test Vehicle Insertion
The Transient Reactor Test (TREAT) Facility is an air-cooled reactor composed of graphite-urania fuel encapsulated in zirconium alloy canisters and surrounded by ~2 ft (~61 cm) of nuclear grade graphite. The primary role of TREAT is to provide in-pile nuclear-heated safety research via transient testing [1]. The following work represents further analyses building upon previously reported work to support larger volume test vehicles within TREAT [2]. The Broad Use Specimen Transient Experiment Rig (BUSTER) provides ample versatility for numerous transient test concepts. However, future testing and experiment needs will require testing environments of different in-core footprints. The versatility of TREAT allows for the development of variegated core layouts with key limitations emplaced as operational safety temperature restrictions and available core reactivity. The focus of this current effort is to gauge core arrangements for TREAT core loadings to support centralized experimental testing of varying dimensional capacity. The total core excess reactivity (ER) was computed for different arrangements to establish comparison tables that enable ready assessment of core ER available for future experiment concepts. Test vehicle worths would then be necessary to establish available ER to support transient testing requirements and to perform reactor performance and safety calculations [3,4].