Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test Pilots”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Slipstream Testing of Amine-Based Solvents at a Low-Rank Coal-Fired Power Plant

Conference presentation for 38th Annual International Pittsburgh Coal Conference, Virtual, September 20–23, 2021. To better assess mitigation strategies for aerosol reduction to extend solvent life, the University of North Dakota Energy & Environmental Research Center (EERC) installed a pilot-scale CO 2 absorption system at a lignite-fired plant in central North Dakota. The pilot-scale system was operated using both commercial KS-1™ solvent and advanced KS-21™ solvent provided by Mitsubishi Heavy Industries (MHI). MHI’s proprietary amine emission reduction unit (AERU™) technology was installed downstream of the absorber columns to reduce solvent losses by recovering amines at the system outlet. Fine particulate loading was measured throughout the capture system with and without a WESP operating and using both solvents. Captured particulate was brought back to the EERC to be analyzed for chemical composition and to be examined by scanning electron microscopy for particulate structure. These variables were then correlated to performance of particulate control devices in reducing aerosol formation and solvent losses.

01 COAL, LIGNITE, AND PEAT↗

FY 2026 Midyear Report: Seismic Monitoring of Underground Vibration Sources Using Distributed Acoustic Sensing and Seismometers

Safeguards-relevant temporal changes in underground facilities can be observed using geophysical monitoring techniques. Seismic waves, in particular, provide valuable insights into subsurface activities and can serve as an important tool for detecting anomalous events that may indicate containment breaches at geological repositories. This midyear report summarizes ongoing efforts to automatically and rapidly detect and locate anomalous vibration signals that could be indicative of potential containment breaches. Previous work during FY25 focused on compiling continuous seismic datasets from two underground sites and developing a database of continuous waveforms and ground-truth event data derived from multiple sensing modalities. Building on this foundation, we are adapting anomaly detection and geolocation algorithms to explore methods for monitoring underground activities using two relatively low-maintenance sensing technologies: a dense surface geophone array deployed at the Pleasant Gap mine in Pennsylvania, and a three-dimensional fiber-optic cable array for distributed acoustic sensing (DAS) installed in the subsurface at the Sanford Underground Research Facility (SURF) in South Dakota. This report summarizes work conducted during the first two quarters of FY26, during which we refined a dynamic power spectral density (PSD)-based detector, applied it independently to each geophone station, and then combined the per‑station detections with density-based spatial clustering of applications with noise (DBSCAN) to cluster events and produce spatial maps over a nine‑day interval. In addition, we outline plans for a field trial at the Waste Isolation Pilot Plant (WIPP) in New Mexico to compare traditional seismic monitoring approaches with DAS techniques and to evaluate the benefits of combined data analysis. Activities during the past two quarters have included the preparation and submission of a Field Test Plan to WIPP for approval, as well as submission to headquarters for review and feedback.

58 GEOSCIENCES↗

Aerosol-Ice Formation Closure Pilot Study (AEROICSTUDY) Field Campaign Report

The aerosol-ice formation closure pilot study (AEROICESTUDY) was a field campaign conducted at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility at the Southern Great Plains (SGP) observatory from October 7 to 28, 2019. The purpose of this campaign was to test a field observational approach for conducting an aerosol-ice formation closure study. In other words, the goal was to predict the number of ice nucleating particles (INPs) from the measurements of physical and chemical aerosol properties and compare those to measured INP number concentrations. This project was motivated by the fact that the aerosol community has widely conducted aerosol radiative closure, aerosol-cloud condensation nuclei (CCN), and CCN-droplet closure studies to test the physical models and parameterizations that cloud-resolving and climate models rely on to perform reliable simulations of the Earth system and energy budget. However, very few closure studies related to INPs have been conducted, and to our knowledge, none using robust, size-resolved, ambient aerosol composition measurements as model inputs.

54 ENVIRONMENTAL SCIENCES↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Overview of Hydraulic Fracturing Test Site 2 in the Permian Delaware Basin (HFTS-2)

Here, the Hydraulic Fracturing Test Site 2 (HFTS-2) is a large collaborative field-based R&D program in the Permian Delaware Basin, funded by the US Department of Energy through the National Energy Technology Laboratory (NETL) and the E&P industry, with support from academia. The projects' main objective is to improve the understating of the hydraulic fracturing process through utilization of advanced diagnostics and collection of through-fracture cores to provide undisputable evidence and attributes of the created hydraulic fractures. At the HFTS-2, in excess of $30 million was used to perform hydraulic fracturing research focusing on the Wolfcamp formation at a field site hosted and operated by Occidental. In addition to the research data collected by the project, Occidental provided a significant amount of background data for about a dozen existing wells in the test area as well as access to previously collected core. Additional technical and laboratory support was provided by the program members. Building on learnings and unanswered questions from HFTS-1 in the Permian Midland basin, the HFTS-2 used eight new producing wells and two existing (parent) wells to perform hydraulic fracturing research. Multiple science wells were drilled to sample and characterize the subsurface, including the collection of 540 feet of core in a vertical pilot hole and 948 feet of high-angle through-fracture core. The project installed permanent fiber optic cables in 3 wells to monitor near wellbore signals during fracturing and to collect cross-well strain measurements. Additional advanced diagnostics included a significant formation evaluation program on the vertical whole core, multi array moment tensor inversion capable microseismic survey, multi-well time-lapse geochemistry analysis, analysis of proppant distribution in producing child and slant core well, and others. We will provide an overview of the HFTS-2 project, including list of the consortium members, details of the test site, experiments performed, and technologies tested.

58 GEOSCIENCES↗

Novel Ionomers and electrode structures for improved PEMFC electrode performance at low PGM loadings (Final Report)

In this project, the objective is to develop new ORR electrocatalysts on optimized supports which can exceed all of the Department of Energy (DOE) 2020 targets listed in DE-FOA-0001412 directly relevant to the subtopic. This project’s approach is to develop novel, electrode-specific ionomers, and integrate them with state-of-the-art NSTF electrocatalyst powder to develop a cathode electrode achieving >= 044 A/mg PGM mass activity, <=30% mass activity loss during metal cycling, and <=0.125 g PGM /kW performance under DOE testing protocols. Ionomer O 2 permeability and proton conductivity will be increased by up to 1.5X over the baseline 3M800 perfluorosulfonate (PFSA) ionomer to enhance cathode electrode performance. Integration of cathode NSTF powder into an ionomer-containing electrode will increase the surface enhancement factor (SEF) to >=40 cm 2 PGM /cm 2 GEO allowing NSTF containing cathodes to exceed DOE MEA robustness targets. This report summarizes this project’s progress towards meeting the stated objectives and includes a summary of significant findings, conclusions, and developments over the entire project period from Oct. 1 st 2016 – Jan. 31 st 2020. This work has overcome key operation robustness issues with classic NSTF electrodes, identified pathways to improved dispersed and dispersed NSTF cathode performance, developed novel ionomers with high bulk conductivity and oxygen permeability, demonstrated exceptional support-independent electrode activity, and significantly increased metal and support stability through ionomer development. At this point, Tufts, MTU and all 5 FCPAD national labs have been involved, and contributed to, the improvements, learning and achievements of this work. Over the course of this project, more than 50 grams of dispersed NSTF powder in 15 different configurations have been generated, paving the way for scaleup within 3M. These whiskers have been processed in multiple ways, including acid leaching, powder-annealed, and sonicated by various means. For Task 2, 27 different types of ionomers were tested, 19 of which were made for the first time during the course of this project. 377 electrode inks with both NSTF and metal-on-carbon catalysts with I/C ratios from 0.2 to 1.2 were generated and mostly coated on a 3M pilot manufacturing line resulting in more than 700 different electrode types.

08 HYDROGEN↗

Leveraging a Southern California Energy Innovation Cluster to Pilot and Validate Emerging Energy Technologies

The EPIC Pilot Program, led by the Los Angeles Cleantech Incubator (LACI), was designed to help early-stage clean technology startups accelerate technical validation, investment readiness, and market entry. The project focused on supporting startups in designing and deploying small-scale pilots with the guidance of EPIC Partners, a network of regional stakeholders in the Southern California energy ecosystem, including but not limited to: the Los Angeles Department of Water and Power (LADWP), the California Energy Commission (CEC), Los Angeles County Metropolitan Transportation Authority (LA Metro), and Edison International, among others. Through mentorship, funding, and site access for technology deployments, the program provided a structured pathway for startups to test and refine their technologies in real-world settings.

14 SOLAR ENERGY↗

Multi-scale dynamic modeling and validation of radial flow fixed bed contactors for post-combustion CO 2 capture using bench scale and pilot plant data

Here, in this work, a multi-scale model of a radial flow fixed bed contactor packed with a carbon sorbent is developed and validated with laboratory-scale and pilot plant scale dynamic data. For the lab scale system, the model results were compared with low, medium and high gas and sweep flowrates, yielding root mean square error (RMSE) of 0.80, 0.63, 0.96 CO 2 mol%, respectively, for the outlet CO 2 concentration profile considering the entire A-D cycle. For the bed outer temperature profile, maximum RMSE was found to be 5.5 °C considering all flowrates and entire A-D cycles. An experimental campaign was developed and applied to a pilot plant at Technology Center Mongstad (TCM), Norway. Approaches were developed for pre-processing of data including consideration of the effect of gas mixing, measurement delay, and determination of cyclic steady-state conditions. Considering profiles during A-D cycles for all test runs, it was found that the maximum RMSE for pressure drop, temperature for the outer section of the bed, temperature for the middle section of the bed, and outlet CO 2 concentration profile remained less than 1.5 mbar, 3.5 °C, 2.8 °C, and 1.3 CO 2 mol%, respectively. The validated model was used to perform sensitivity studies on several key design operating variables for the adsorption-desorption cycle. It was found that the flow rate and concentration of flue gas have dominant nonlinear effects on the breakthrough time while the desorption time was strongly affected by the sweep gas flowrate for the specific sorbent being evaluated in this study.

20 FOSSIL-FUELED POWER PLANTS↗

Full-Scale Development and Piloting of a Hybrid Digital Twin for Wastewater Operations Optimization

This full-scale pilot of a machine learning based nutrient controller/digital twin is being done as part of The Water Research Foundation (WRF) project 5121: Development of Innovative Predictive Control Strategies for Nutrient Removal. The overall goal of this project is to develop and full-scale test a hybrid (machine learning + mechanistic model) nutrient management controller at four different water resource recovery facilities (WRRFs). The controller demonstrates both short-term optimization functions and predictive capabilities. This project includes the design of the controller, its performance at the WRRFs, and a description of the future improvements.

Johnson, Bruce↗

Geomechanical and Hydrogeological Evaluation of a Shallow Hydraulic Fracture at the Devine Fracture Pilot Site, Medina County, Texas

UT-Austin’s Devine Fracture Pilot Site, 50 miles southwest of San Antonio, Texas, has been targeted for a comprehensive, multidisciplinary development of fracture diagnostic techniques that are cross-validated by ground-truth data acquisition near a recently created, 175-ft-deep, horizontal hydraulic fracture (Ahmadian et al. 2018 Demonstration of proof of concept of electromagnetic geophysical methods for high resolution illumination of induced fracture networks. In Proceedings of the SPE Hydraulic Fracturing Technology Conference and Exhibition, The Woodlands, Texas, USA, 23–25 January 2018. SPE-189858-MS.). To evaluate the fracture diagnostic methods at this site, we conducted injection tests with a predefined volumetric flow-rate profile, resembling a diagnostic fracture injection test on September 2020. Subsequently, we developed hydrogeological and geomechanical models based on flow-rate and bottomhole-pressure measurements. History-matching efforts using a simplified layer-cake hydrogeological model resulted in the field-scale formation permeability of 9.87 × 10 –15 m 2 (10 mD) and Darcy-scale fracture permeability. The analysis of the bottomhole pressure and injection-rate history showed that (1) the newly created horizontal fracture was closed adjacent to the injection well pre-injection and (2) the initial pump-pressure increase at a nominal volumetric injection rate led to near-well fracture reopening, fluid conductivity increase, and abrupt injection-rate increase. To overcome hydrogeological-model limitations of predicting fracture reopening throughout injection, we extended the modeling to a finite-element, poroelastic analysis of horizontal-fracture growth using a cohesive-zone model. Using this fracture-reopening model, we improved the history match of the transient-pressure response during the experiment by adjusting the hydromechanical properties. Furthermore, post-injection pressure transient analyses helped reduce uncertainty in the overburden-stress gradient, and the initial hydraulic-fracturing simulation verified the plausibility of achieving the surveyed propped fracture area.

02 PETROLEUM↗

Data Analysis of Energy Code Compliance in Commercial Buildings

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Analysis of Energy Code Compliance in Commercial Buildings (Rev. 1)

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technical Specification Surveillance Interval Extension Using Self-Diagnostics

As part of the Light Water Reactor Sustainability program, an ongoing research effort is being conducted on technical specifications surveillance interval extension of digital equipment in nuclear power plants. The research team is led by Idaho National Laboratory and includes Pacific Northwest National Laboratory, Technology Resources, and Oak Ridge National Laboratory. This research focuses on developing methods for applying the U.S. Nuclear Regulatory Commission (NRC)–approved guidance to implement a licensee-controlled, risk-informed surveillance frequency change program in digital instrumentation and control (I&C) systems that include self-diagnostics and online monitoring (OLM) capabilities. Although approved methods exist for extending technical specifications (TS) surveillance test intervals (STIs) for general equipment, including analog I&C equipment, gaps remain in technology and guidance on crediting newer digital equipment’s internal self-diagnostics and OLM characteristics. Previous research described a general methodology for crediting internal self-diagnostics for extending surveillance test intervals. The methodology used self-diagnostics to detect—and credited recovery from—failure. Self-diagnostics were also applied for performance monitoring during the extended surveillance interval. This report discusses the status of recent activities to evaluate the previously developed methodology using a pilot study. Although both a utility partner for a pilot study and a specific digital asset were identified in FY2020, delays in obtaining proprietary information resulted in a limited ability to fully evaluate the methodology, and further interactions were complicated by the COVID pandemic. Therefore, at that time, the use of public-domain information—along with current processes for surveillance interval extension through a surveillance frequency control program—identified the need to fully assess diagnostic coverage as part of the pilot study. Furthermore, self-diagnostics were also identified as a potential option to replace the drift analyses conducted as part of current STI extension procedures. In FY2022, the project was reconstituted with the industry partner, and information and data were made available by the industry partner to the research team for review. The shared information included failure event descriptions and data for a digital I&C system since its implementation, as well as recent STI extension interval reports developed by the utility partner on that digital I&C system. This report presents an evaluation of this information and data and describes an application of the proposed methodology cited above. The methodology seeks to take advantage of the self-diagnostics and OLM capabilities to reduce risk or reduce the level of qualitative monitoring assessment needed to perform a risk-informed STI extension using existing NRC approved guidance or both. Addressing these issues of STI extension by crediting self-diagnostics is likely to result in benefits for current and future nuclear power plant (NPP) operations, including lowering the barriers to adoption of digital I&C systems and increasing cost savings by deferring or eliminating unneeded preventive maintenance (tasks or checks or activities). Specifically, self-diagnostic and OLM capabilities of newer digital equipment being installed in non-safety and safety applications are designed to detect failures, provide early warning of potential failures, and notify plant operators to take appropriate action to reduce out of service (OOS) time thus protecting safety margins. Moreover, the equipment is expected to provide information that time-related operational degradation is identified early to ensure timely and planned corrective actions instead of a reactive and unplanned approach ahead of an extended-surveillance interval.

42 ENGINEERING↗

Experimental Investigation of the Heat Transfer between Finned Tubes and a Bubbling Fluidized Bed with Horizontal Sand Mass Flow

The sandTES technology utilizes a fluidized bed counter current heat exchanger for thermal energy storage applications. Its main feature is an imposed horizontal flow of sand (SiO2) particles fluidized by a vertical air flow across a heat exchanger consisting of several horizontal rows of tubes. Past international research on heat transfer in dense fluidized beds has focused on stationary (stirred tank) systems, and there is little to no information available on the impact of longitudinal or helical fins. Previous pilot plant scale experiments at TU Wien led to the conclusion that the currently available correlations for predicting the heat transfer coefficient between the tube surface and the surrounding fluidized bed are insufficient for the horizontal sand flow imposed by the sandTES technology. Therefore, several smaller test rigs were designed in this study to investigate the influence of different tube arrangements and flow conditions on the external convective heat transfer coefficient and possible improvements by using finned tubes. It could be shown that helically finned tubes in a transversal arrangement, where the horizontal sand flow is perpendicular to the tube axes, allows an increase in the heat transfer coefficient per tube length (i.e., the virtual heat transfer coefficient) by a factor of 3.5 to about 1250 W/m2K at ambient temperature. Based on the literature, this heat transfer coefficient is expected to increase at higher temperatures. The new design criteria allow the design of compact, low-cost heat exchangers for thermal energy storage applications, in particular electro-thermal energy storage.

25 ENERGY STORAGE↗

A Novel Process for Converting Coal to High-Value Polyurethane Products

Battelle has demonstrated a patented process for making high-value, polyurethane (PU) foam from coal, based on preparing liquefied coal via direct liquefaction, converting it to polyols as an intermediate via ozonation, and then making PU foams from these polyols. This process represents a breakthrough in innovative utilization of U.S. coals, and is applicable to bituminous as well as sub-bituminous coals. The resulting PU foam products are projected to have an extremely high value (i.e., over $\$5,000$ /ton), with nearly 100% of carbon utilization from coalderived liquid feedstock, and 31.5% to 43.5% of the carbon in the PU foam polyol product being bio-based. The targeted products represent an extremely large (i.e., over $80 billion/year), existing PU foam market, which could expand into making coatings and adhesives. The process can further help reduce petroleum imports, while improving the economics of PU foam production. This work was completed with funding from the National Energy Technology Laboratory (NETL), with cost share from the State of Ohio’s Ohio Development Services Agency (ODSA) and others, and has advanced the process to 10 kg/day continuous scale and thus to Technology Readiness Level (TRL) 5. A total of 48 coal-based polyols were prepared and evaluated. The initial 28 polyols focused on range finding for ideal conditions. The later 20 polyols were produced as part of process optimizations. These optimizations were targeted around a continuous ozonolysis process to evaluate extended time reactions and to create the necessary intermediate for production of 1-gallon samples of polyol. The most unique attribute of Battelle’s polyol is in the utilization of coal’s aromaticity to gain final foam rigidity. Typically, polyols depend on the isocyanate fraction and cross-linking to gain rigidity. By utilizing coal, we were able to maintain rigidity while reducing the overall hydroxyl value of the polyol. This is important as lower hydroxyl value leads to greater percent weight of the coal-based polyol because less isocyanate is required for foaming. This leads to greater foam cost savings. This report provides the details, process, and process cost models of the conversion of coal to polyols and further to PU foams. Battelle’s process begins with coal liquids. These liquids can be obtained by two processes: coal coking or pyrolysis to produce coal tar, and Battelle’s biobased coal-to-liquids (CTL) process to produce heavy syncrude after liquifying >85% coal. After liquification, Battelle utilizes ozonolysis to create functionalization on the polyaromatic coal structure. The functionalization is then converted to the final polyester polyol through transesterification, or to hydroxyamide polyol through amidification. Equivalent or better standard properties have been obtained for 2 lb/ft 3 density rigid, water and freon-alternative blown foams, including compressive strength, density, R-value, and dimensional stability. Target applications for these foams are insulation, packaging, and energy-absorbing foams. Some exploratory testing also showed promise for adhesives applications. A detailed economic analysis showed that Battelle’s polyol process is economical, at a 140 metric tons per day (MTD) polyol production scale. An attractive return on investment (ROI) at competitive pricing validates the process is ready for a pilot-plant demonstration. A scale-up plan is provided.

01 COAL, LIGNITE, AND PEAT↗

RH-TRU Waste Streams: HFDA Crucibles Create New Complex Waste Stream

This project focuses on the removal of the Hot Fuel Dissolution Apparatus (HFDA) crucibles from the Hot Fuel Examination Facility’s (HFEF) hot cells to create space for upcoming projects. The project team has created a crucible and pyro-salt non-debris waste stream that can be disposed of at Waste Isolation Pilot Plant (WIPP). Chemical Compatibility Examinations (CCEs) must be performed on candidate waste by reviewing the types of chemicals used in the experiments, information found in INL Process Knowledge Summary Reports (PKSRs), and Environmental Protection Agency guides on chemical compatibility. The CCEs identify which chemicals can be safely combined to ensure adverse reactions do not occur in the waste packages. The CCEs are then used to update the PKSR, Basis of Knowledge, and Acceptable Knowledge documents and demonstrate compliance with the WIPP Waste Acceptance Criteria. Once documents are finalized, they are reviewed and approved by the WIPP Central Characterization Project (CCP) to ensure proper waste stream characterization. After the documents are approved, the crucibles can be packaged and shipped to the Idaho Nuclear Technical and Engineering Center for storage awaiting certification. CCP will certify the waste using the approved documents and a series of confirmatory testing before being shipped and disposed in WIPP’s deep geological repository. Currently, the CCE is in progress and the PKSRs are being updated.

Basis of Knowledge↗

Heavy Oil Polymer EOR in the Challenging Alaskan Arctic - It Works!

Under co-sponsorship of the US Department of Energy and Hilcorp Alaska LLC the first ever polymer field pilot commenced on 8/28/2018 in the Schrader Bluff heavy oil reservoir at the Milne Point Field on Alaska North Slope (ANS). The primary objective of the pilot is to prove the efficacy of polymer Enhanced Oil Recovery (EOR) to unlock the vast heavy oil resources on ANS. More than two and half years after startup, the polymer injection, supporting laboratory experiments and simulation studies steadily continue. The pilot started injecting hydrolyzed polyacrylamide (HPAM), at a concentration of 1,750 ppm to achieve a target viscosity of 45 cP, into the two horizontal injectors in the flood pattern. Production is monitored in the two horizontal producers. Based on laboratory measurements of polymer viscosity at reservoir conditions, the team decided to reduce polymer concentration to 1,200 ppm since July 2020 in an effort to control injection pressure and optimize polymer utilization. Quality control (QC) on the field ensures uniform polymer solution properties. Representative rock and fluid systems and test conditions are utilized in the corefloods on polymer retention, effect of injection water salinity, polymer loading, and their combinations on oil recovery. A history matched reservoir simulation model for forecasting oil recovery was developed on the basis of all the available field data. Field concerns related to the post-polymer breakthrough impact on flow assurance is addressed via specialized laboratory tests. Notwithstanding early operational disruptions and hydration issues, continuous polymer injection in both injectors has been achieved. To date, 950,000 lbs of polymer or 2 million barrels of polymer solution, equating to 13% of total pore volume (PV), has been placed in the flood pattern, serving as an effective indicator of adequate polymer injectivity. So far, the success of polymer EOR is evident from drastically reduced water cut in the producers, an estimated incremental 1,000 bopd over waterflood, and a favorable polymer utilization of 1.7 lbs/barrel of incremental oil. Polymer breakthrough was observed 26 months after the start of polymer injection. Main observations from corefloods are unusually high polymer retention values in some cases and a positive response to low salinity water. Although the heterogeneity in the flood pattern and exceptionally low water cut pose some challenges, persistent novel and justifiable simulation approaches have resulted in a robust history matched model. Experimental results on produced fluids treatment provide operational guidance for improved oil-water separation and mitigation of heater tube fouling. The ongoing success of the pilot is a key indicator of bringing the team ever closer to meeting the project’s primary objective. The encouraging results of the pilot is one of the drivers that has provided the impetus to apply polymer EOR throughout the Milne Point Field, which would increase oil recovery and extend the economic life of the Trans Alaska Pipeline System. The scientific knowledge, including the many lessons learned from this pilot also has referential value for other potential heavy oil EOR projects throughout the world. The collected data, operational lessons learned, and the overall success of the pilot are summarized in the paper.

None, None↗

Briquetting characteristics of woody and herbaceous biomass blends: Impact on physical properties, chemical composition, and calorific value

Abstract Intercropping (or polyculture) is gaining a lot of interest as it increases yields, allows better utilization of resources (water and nutrients), and provides better land management. The objective of this study is to understand the briquetting characteristics of woody and herbaceous biomass blends, which might result from intercropping. Tests were conducted on blends of lodgepole pine, switchgrass, and corn stover biomass using three hammer mill screen sizes (i.e., 4.8, 12.7, and 19.05 mm), three blend moistures (12%, 15%, and 18%, w.b.), and two‐ and three‐blend ratios (i.e., 1:1 and 1:1:1) using a pilot‐scale hydraulic briquette press. The briquette properties, such as unit and bulk density, durability rating after 5 days of storage (as they tend to attain stable density), and the energy consumption of the process were measured. The results indicate that moisture content of 12% and 15% (w.b.) and smaller hammer mill screen size of 4.8 mm increased the unit and bulk densities to >750 and >430 kg/m 3 and moisture content (15% and 18% (w.b.)) and hammer mill screen size of 12.7 and 19.05 mm produced briquettes with durability rating values of >95%. The higher moisture content of 18% (w.b.) and the hammer mill screen size of 12.7 and 19.05 mm had the highest energy consumption. The proximate and ultimate analysis showed that energy content improved by blending lodgepole pine with both corn stover and switchgrass and also showed increased calorific value and reduced ash content. Scanning electron microscopy micrographs showed interlocking of particles and cracks in the briquettes. © 2020 Society of Chemical Industry and John Wiley & Sons, Ltd

Tumuluru, Jaya Shankar↗