Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tensile Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Status of Post Irradiation Examination of FCAB and FCAT Irradiation Capsules

A series of irradiation programs are ongoing to address the need for determining the radiation tolerance of FeCrAl alloys. These irradiation programs, deemed the FCAT and FCAB irradiation programs, use the High Flux Isotope Reactor (HFIR) to irradiate second generation wrought FeCrAl alloys and early-generation powder-metallurgy (PM) oxide dispersion-strengthened (ODS) FeCrAl alloys. Irradiations have been or are being performed at temperatures of 200°C, 330°C, and 550°C from doses of 1.8 dpa up to 16 dpa. Preliminary post-irradiation examination (PIE) on low dose (<2 dpa) irradiation capsules of tensile specimens has been performed. Analysis of co-irradiated SiC thermometry have shown reasonable matching between the nominal irradiation temperatures and the target irradiation temperatures. Room temperature tensile tests have shown typical radiation-induced hardening and embrittlement at irradiations of 200°C and 330°C, but a propensity for softening when irradiated to 550°C for the wrought alloys. The PM-ODS FeCrAl specimens showed less hardening compared to the wrought alloys. Future PIE includes high temperature tensile tests on the low dose irradiation capsules as well as the determination of reference fracture toughness transition temperature, T o , in alloys irradiated to 7 dpa and higher.

36 MATERIALS SCIENCE↗

Microstructure and mechanical properties of ultrasonic spot welding of AA7075-T6 and A380 casting aluminum alloy

Ultrasonic spot welding (USW) was employed to join AA7075-T6 and casting Al alloy A380. Under a constant welding power, the influence of the welding time duration (from 1 s to 3 s) on peak temperature, microstructure, hardness, and mechanical strength of the joints were studied. It was found that the peak temperature increased with welding time. A sound solid-state metallurgical bonding was obtained at the joint interface. The cracks occurred at the edge of the joints were eventually eliminated as the welding time increased. A layer of refined grains formed in A380 adjacent to the bonding line. Further, hardness reduction occurred in AA7075 at the joint interface and the degree of hardness reduction and the volume increased with the peak temperature. By increasing welding time, lap shear tensile tests show that the peak load increased from 5.3 kN to 6.55 kN. The corresponding interfacial shear strength ranged from 96.29 MPa to 99.72 MPa, lower than the shear strength of both base materials (331 MPa for AA7075 and 185 MPa for A380). All joint samples exhibited interfacial fracture after lap shear tensile testing, with a thin layer of A380 remnant attached to AA7075 at the center of the fractured surface.

36 MATERIALS SCIENCE↗

Thermo-Oxidative Aging of LDPE/Stearoyl Chloride-Grafted Cellulose Nanocrystals Blown Films

The effect of the incorporation of pristine and stearoyl chloride grafted CNCs on the chemical, mechanical, thermal and microstructural properties, during the thermo-oxidative aging, of LDPE blown films at 60 °C was studied. The success of the pristine CNCs grafting was assessed by Fourier transform infrared (FT-IR) spectroscopy, X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), Thermal-gravimetric analysis (TGA), Atomic Force Spectroscopy (AFM) and contact angle measurements. The results show that chemical modification decreases both, the CNCs thermal stability and the polar component of surface energy, i.e. increases the nanocrystals hydrophobicity. Also, it was found that neither CNCs crystalline structure nor its dimensions changed with grafting. The changes on the blown film properties during thermo-oxidative aging were monitored using FT-IR, DSC, DRX and tensile testing. It was found that the CNCs catalyzed the production of carboxylic acids as a final degradation by-product, whereas the CNC-g-C{sub 18} inhibits its formation, i.e. in presence of CNCs grafted with stearoyl chloride the catalytic effect attributed to the pristine CNCs was partially inhibited. The DSC, DRX and tensile testing results show the microstructural arrangements due to the annealing and the chains oxidation predominated during the first 30 days of aging and then chain scissions prevail. These findings suggest an analogous reduction in molecular weight at the end thermo-oxidative aging. In addition, the presence of a high concentration of carboxylic acid and the drop in molecular weight after LDPE aging will facilitate the biodegradation of these oxo-degradable films.

36 MATERIALS SCIENCE↗

Polyacrylonitrile nanofibers with added zeolitic imidazolate frameworks (ZIF-7) to enhance mechanical and thermal stability

Zeolitic imidazolate framework 7/polyacrylonitrile (ZIF-7/PAN) nanofiber mat of high porosity and surface area can be used as a flexible fibrous filtration membrane that is subjected to various modes of mechanical loading resulting in stresses and strains. Therefore, the stress-strain relation of ZIF-7/PAN nanofiber mats in the elastic and plastic regimes of deformation is of significant importance for numerous practical applications, including hydrogen storage, carbon dioxide capture, and molecular sensing. Here, we demonstrated the fabrication of ZIF-7/PAN nanofiber mats via electrospinning and report their mechanical properties measured in tensile tests covering the elastic and plastic domains. The effect of the mat fabrication temperature on the mechanical properties is elucidated. We showed the superior mechanical strength and thermal stability of the compound ZIF-7/PAN nanofiber mats in comparison with that of pure PAN nanofiber mats. Material characterization including scanning electron microscope, energy-dispersive X-ray spectroscopy, tensile tests, differential scanning calorimetry, and Fourier transform infrared spectroscopy revealed the enhanced chemical bonds of the ZIF-7/PAN complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase Transformation of Thermally Aged and Neutron Irradiated Duplex Stainless Steel Used in LWRs. Final report

The lifetime of reactor components made of duplex stainless steels can be limited by the embrittlement from thermal aging, neutron irradiation or a synergistic effect between thermal aging and neutron irradiation. There is still a large scientific knowledge gap in understanding the phase evolution in duplex stainless steels upon thermal aging with or without neutron irradiation, the synergistic effect between thermal aging and neutron irradiation, and the impacts of structural evolution on material mechanical responses. In this project, totally, five major tasks were completed through this project: a) the in-situ WAXS tensile tests of thermally aged cast duplex stainless steels, b) the EXAFS investigation of thermally aged cast austenitic stainless steel and welds of austenite sainless steel, c) the characterization of irradiation effect on neutron irradiated CASS using APT, d) characterize the ferrite hardening of neutron irradiated CASS using nanoindentation, and e) the FEM modelling to validate the in-situ WAXS tensile tests and to simulate the stress/strain distribution during deformation for thermally aged duplex stainless steel. In summary, the thermal aging without neutron irradiation can significantly increase the strength of ferrite phase through the spinodal decomposition and G-phase precipitations. The in-situ X-ray experiments show that the hardening effect in ferrite phase can significantly alter the load partition between the ferrite and austenite phases. Atom probe tomography characterizations on samples irradiated to 0.08, 3, 5, 10, 20, and 40 dpa shows that neutron irradiation has dominated the microstructural evolution after 3 dpa, and the spinodal decomposition has saturated yet even at 40 dpa based on the quantified wavelength and amplitude.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Portable, Controlled-Load-Rate Tension Tester

Tensile-testing machine for ceramic and foam materials has selfcontained air supply with built-in airflow controller. New machine easily moved to point of use, and loads applied automatically at constant rate of increase, without fluctuations caused by manual control of supply pressure. Eliminates impact after failure of specimen so it does not damage itself. Potential applications of machine include tensile tests of large composite parts that contain localized defects and adhesion tests of virtually any bonded structure.

Jamieson, R. S.↗

Full-field Strain Methods for Investigating Failure Mechanisms in Triaxial Braided Composites

Composite materials made with triaxial braid architecture and large tow size carbon fibers are beginning to be used in many applications, including composite aircraft and engine structures. Recent advancements in braiding technology have led to commercially viable manufacturing approaches for making large structures with complex shape. Although the large unit cell size of these materials is an advantage for manufacturing efficiency, the fiber architecture presents some challenges for materials characterization, design, and analysis. In some cases, the static load capability of structures made using these materials has been higher than expected based on material strength properties measured using standard coupon tests. A potential problem with using standard tests methods for these materials is that the unit cell size can be an unacceptably large fraction of the specimen dimensions. More detailed investigation of deformation and failure processes in large unit cell size triaxial braid composites is needed to evaluate the applicability of standard test methods for these materials and to develop alternative testing approaches. In recent years, commercial equipment has become available that enables digital image correlation to be used on a more routine basis for investigation of full field 3D deformation in materials and structures. In this paper, some new techniques that have been developed to investigate local deformation and failure using digital image correlation techniques are presented. The methods were used to measure both local and global strains during standard straight-sided coupon tensile tests on composite materials made with 12 and 24 k yarns and a 0/+60/-60 triaxial braid architecture. Local deformation and failure within fiber bundles was observed, and this local failure had a significant effect on global stiffness and strength. The matrix material had a large effect on local damage initiation for the two matrix materials used in this investigation. Premature failure in regions of the unit cell near the edge of the straight-sided specimens was observed for transverse tensile tests in which the braid axial fibers were perpendicular to the specimen axis and the bias fibers terminated on the cut edges in the specimen gage section. This edge effect is one factor that could contribute to a measured strength that is lower than the actual material strength in a structure without edge effects.

Littell, Justin D.↗

Intermediate-Term Thermal Aging Effect Evaluation for Grade 92 and 316L at The LWR Relevant Temperature

Life extension of the existing nuclear reactors imposes accumulated damages, such as higher fluences and longer period of corrosion, to structural materials, which would result in significant challenges to the traditional reactor materials such as type 304 and 316 stainless steels. Advanced alloys with superior radiation resistance will increase safety margins, design flexibility, and economics for not only the life extension of the existing fleet but also new builds with advanced reactor designs. The Electric Power Research Institute (EPRI) teamed up with Department of Energy (DOE) on the Advanced Radiation Resistant Materials (ARRM) program, aiming to develop and test degradation resistant alloys from current commercial alloy specifications by 2021 to a new advanced alloy with superior degradation resistance in light water reactor (LWR)-relevant environments by 2024. Based on a comprehensive microstructure and property screening performed in Phase-1 of the ARRM program, a total of five alloys, together with 316L and X-750 as references, were down-selected for Phase-2 neutron irradiation studies. Because thermal aging could exert a synergistic effect on neutron irradiation due to the low neutron damage rate on the order of 10 –7 displacements per atom per second (dpa/s), Grade 92 (one of the five down-selected alloys) and two heats of 316L were selected in this task to study the effect of aging at 350°C for 12.5–12.7 kh on microstructure and mechanical properties. The aging time is approximately corresponding to 5 dpa neutron irradiation, which can be served as a reference for the 5-dpa-irradiated samples of the alloys to help understand the independent neutron damage influence on microstructure and mechanical properties. Optical microscopy and scanning electron microscopy were used for microstructural characterization. Hardness, tensile, Charpy impact toughness, and fracture toughness in the ductile regime of the aged samples were examined. The aging of Grade 92 led to the formation of many Laves phase in sizes of ~100–200 nm and resulted in some reduction in hardness and yield/ultimate tensile strength with some increases in uniform and total plastic elongations, which may have helped the enhancement of Charpy impact toughness, e.g., ~4 J increase in upper-shelf energy and 20.5°C reduction in ductile-brittle transition temperature compared with the unaged condition. The fracture toughness of the aged Grade 92 showed decent toughness of ~303 MPa√m (K Jq ) with ~87 tearing modulus at 22°C, which reduced to ~241 MPa√m (~20% reduction) with ~75 tearing modulus at 300°C. The two heats of 316L are differentiated by their amounts of δ-ferrite, i.e., ~1 vol% in heat T1103 and ~4 vol% in heat N5B8. The two heats of 316L were subjected to 15% cold work (CW) as this condition is often used in nuclear reactors to help trapping radiation-induced defects and thus postpone the steady state swelling stage. The aging did not result in any noticeable microstructure changes, except for possible segregations at grain boundaries that need to be further investigated. The aging resulted in slight reduction in hardness of 316L-T1103 and slight increase in hardness of 316L-N5B8, which is consistent with their tensile testing results. The 15%CW might have introduced some inhomogeneity, resulting in large standard deviations in hardness, which were reduced after the aging. The aged 316L followed the same trend as the unaged condition for the strength and elongation results from the tensile testing. Minimum elongations appeared within ~300–600°C, above which the elongations seem to increase. Unlike the negligible or minor changes in microstructure, hardness and tensile results of the two heats of 316L, their fracture toughness showed noticeable difference. The aged 316L-T1103 showed good toughness of ~350 MPa√m with ~80 tearing modulus at 22°C, which reduced to ~271 MPa√m (~23% reduction) with ~83 tearing modulus at 300°C. In contrast, the aged 316L-N5B8 showed lower toughness of ~244 MPa√m with ~53 tearing modulus at 22°C, which reduced to ~180 MPa√m (~26% reduction) with ~31 tearing modulus at 300°C. The preliminary results indicate that the presence of high volume of δ-ferrite would noticeable impair fracture toughness although it may not influence hardness and tensile properties.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lattice Structured Lightweight Structural Materials

The development of lightweight structural materials is crucial for enhancing the performance and deployment feasibility of fission batteries. This study aims to produce lightweight structural materials whose strength-to-weight ratios exceed those of current widely used structural materials. To achieve this, advanced modeling and simulation tools were employed to design lattice structures with different lattice parameters and different lattice types. A process was successfully developed for transforming lattice-structured models into Multiphysics Object Oriented Simulation Environment (MOOSE) inputs. Finite element modeling (FEM) was used to simulate the uniaxial tensile testing of the lattice-structured parts to investigate the stress distribution at a given displacement. The modeling results showed that the lattice-structured sample displayed a lower Young’s modulus in comparison to the solid material; the increase in solid shell thickness and blend radius enhances the mechanical performance; and the effect of unit cell size on macro scale stress is minimal. Tensile testing was conducted on the solid and lattice-structured materials fabricated by laser powder bed fusion (LPBF) additive manufacturing. The experimental results agreed well with the model prediction. The approach of using modeling as a guiding tool for preliminary material design can significantly save time and cost for new material development.

lightweight material↗

Changes in Polymeric Tether Properties Due to Atomic Oxygen

The Propulsive Small Expendable Deployer System (ProSEDS) mission is designed to provide an on-orbit demonstration of the electrodynamic propulsion capabilities of tethers in space. The ProSEDS experiment will be a secondary payload on a Delta II unmanned expendable booster. A 5-km conductive tether is attached to the Delta II second stage and collects current fiom the low Earth orbit (LEO) plasma to facilitate de-orbit of the spent stage. The conductive tether is attached to a 10-km non-conductive tether, which is then attached to an endmass containing several scientific instruments. Atomic oxygen (AO) erodes most organic materials. As the orbit of the Delta II second stage decas, the AO flux (atoms/sq cm sec) increases. A nominal AO fluence of 1 x l0(exp 21) atoms/sq cm was agreed upon by the investigators as an adequate level for evaluating the performance of the tether materials. A test series was performed to determine the effect of atomic oxygen (AO) on the mechanical integrity and possible strength loss of ProSEDS tether materials. The tether materials in this study were Dyneema, an ultra-high molecular weight polyethylene material used as the non-conducting portion of the ProSEDS tether, and the Kevlar core strength fiber used in the conductive tether. Samples of Dyneema and Kevlar were exposed to various levels of atomic oxygen up to 1.07 x 10(exp 21) atoms/sq cm in the Marshall Space Flight Center Atomic Oxygen Beam Facility (AOBF). Changes in mass were noted after AO exposure. The tethers were then tensile-tested until failure. AO affected both the Dyneema and Kevlar tether material strength. Dyneema exposed to 1.07 x 10(exp 21) atoms/sq cm of atomic oxygen failed due to normal handling when removed fiom the AOBF and was not tensile-tested. Another test series was performed to determine the effect of AO on the electrical properties of the ProSEDS conductive tether. The conductive tether consists of seven individually coated strands of 28 AWG 1350-0 aluminum wire. The conductive coating, developed by Triton Systems, Inc., is a mix of polyanaline and COR, a clear AO-resistant polymer.

Finckenor, Miria M.↗

Microstructure and high temperature tensile properties of 316L fabricated by laser powder-bed fusion

316L stainless steel fabricated by laser powder-bed fusion (LPBF) has attracted significant attention due to a unique combination of strength and ductility at room temperature. Understanding of high temperature tensile properties of LPBF fabricated 316L is, however, limited. In the present investigation, tensile testing was conducted at 20–700ºC on LPBF 316L in as printed condition and after annealing for 5 h at 500–800ºC. Room temperature data confirmed the excellent ductility of the LPBF-processed 316L steel due to the cellular structure with high dislocation density. However, a significant decrease in ductility was observed at temperatures above 200ºC. These results are consistent with a change of deformation mechanisms observed in wrought 316L, with twinning playing a key role at room temperature. Finally, microstructure characterization and tensile testing revealed that the cellular structure is stable up to 500ºC, but a decrease of yield strength was observed at temperatures above 600ºC likely due to a decrease in dislocation density via annealing.

36 MATERIALS SCIENCE↗

Microstructurally based variations on the dwell fatgue life of titanium alloy IMI 834

An experimental study was undertaken to determine the role of microstructure on the fatigue life reduction observed in titanium alloy IMI 834 under dwell loading conditions. The wave forms compared were a trapezoid with 15 and 30 second hold times at the maximum test load and a baseline, 10 Hertz, haversine. The stress ratio for both loading wave forms was 0.10. The fatigue loading of each specimen was conducted in a vacuum within a scanning electron microscope chamber which minimized the possibility that the laboratory environment would adversely affect the material behavior. Two microstructural conditions were investigated in the experimental program. The first involved standard 'disk' material with equiaxed alpha in a transformed beta matrix. The second material was cut from the same disk forging as the first but was heat treated to obtain a martensitic alpha prime microstructure. Tensile tests were performed prior to the onset of the fatigue loading portion of the study, and it was determined that the yield strengths of the specimens from both material conditions were within ten percent. The maximum fatigue loads were chosen to be 72 percent of the average yield strength for both materials as determined from the tensile tests. It was found that the cycles to failure from the 10 Hertz loading wave form were reduced by a factor of approximately five when the loading was changed to the trapezoidal wave form for the standard 'disk' material. The fatigue life reduction for the martensitic structure under identical test conditions was approximately 1.75. The improvement observed with the martensitic structure also was accompanied by an increase in overall fatigue life for the wave forms tested. This paper will review the results and conclusions of this effort.

Thomsen, Mark L.↗

Analysis of Graphite Reinforced Cementitious Composites

This paper describes analytical methods that can be used to determine the deflections and stresses in highly compliant graphite-reinforced cementitious composites. It is demonstrated that the standard transform section fails to provide accurate results when the elastic modulus ratio exceeds 20. So an alternate approach is formulated by using the rule of mixtures to determine a set of effective material properties for the composite. Tensile tests are conducted on composite samples to verify this approach; and, when the effective material properties are used to characterize the deflections of composite beams subject to pure bending, an excellent agreement is obtained. Laminated composite plate theory is also investigated as a means for analyzing even more complex composites, consisting of multiple graphite layers oriented in different directions. In this case, composite beams are analyzed by incorporating material properties established from tensile tests. Finite element modeling is used to verity the results and, considering the complexity of the samples, a very good agreement is obtained.

Vaughan, Robert E.↗

Microstructure, Texture, and Mechanical Properties of Ni-W Alloy After Accumulative Roll Bonding

In this study, the microstructure, texture, and mechanical properties evolution of Ni-14W (wt.%) alloy processed up to four cycles of accumulative roll-bonding (ARB) were investigated using electron backscatter diffraction, microhardness measurements, and tensile tests. The initial equiaxed grains, with an average size of 10 μm, underwent a strong refinement after ARB processing. The elongated ultrafine grains were parallel to the rolling direction, with a grain thickness of 0.2 µm. The texture after ARB processing was characterized by the typical rolling components (Copper, S and Brass), which showed a tendency toward stabilization after four cycles. The microhardness increased substantially (+ 86%) and seemed to saturate after three cycles. The tensile tests demonstrated that Ni-14W samples subjected to ARB processing exhibited high strength (> 1200 MPa after three ARB cycles) and very poor ductility.

36 MATERIALS SCIENCE↗

Structure and Sulfur: Tuning the Viscoelastic and Surface Properties of Natural Keratin Fibers

Natural keratin fibers, such as wool, possess a complex hierarchical structure that governs their mechanical properties and surface energy. However, the extent to which these characteristics are influenced by combined contributions of structural variations (e.g., fiber diameter, intermediate filament (IF) packing) and chemical composition (e.g., disulfide bond density) remains poorly understood. In this study, we investigate wool fibers from five sheep breeds (Merino, Polwarth, Cheviot, Eider, and Devon) to elucidate how these factors influence viscoelasticity and surface interactions. Using a multimodal approach integrating interfacial and bulk characterization methods, including inverse gas chromatography (IGC), atomic force microscopy-infrared spectroscopy (AFM-IR), X-ray photoelectron spectroscopy (XPS), uniaxial tensile testing, and synchrotron small-angle X-ray scattering (SAXS), we show that the nanometer-thick 18-methyleicosanoic acid (18-MEA) layer is consistently present across all wool types and plays a key role in governing hydrophobicity and surface heterogeneity. A controlled isothermal treatment at 200 °C, designed to cleave disulfide bonds, results in a nearly 40% reduction in specific surface area across all fiber types, accompanied by a significant decrease in tensile strength and 80% reduction in elongation at break for Merino and Devon wool, but limited influence on the mechanical properties of Eider fibers. Furthermore, rate-dependent tensile testing within the elastic regime reveals distinct viscoelastic responses among the fiber types, suggesting that the sulfur-rich protein matrix surrounding IFs and its structure contribute actively to stress partitioning. Altogether, when combined with conclusions from SAXS measurements of IF spacing, our work offers compelling insights into the role of the keratin-associated protein (KAP) matrix in shaping wool fiber mechanics. Differences in mechanical behavior among wool types, despite similar IF spacing or sulfur content, highlight the importance of matrix composition and cross-linking density, suggesting that the molecular architecture of the KAP network may be a dominant factor in determining fiber performance.

X-ray scattering↗

Analysis of Graphite-Reinforced Cementitious Composites

Strategically embedding graphite meshes in a compliant cementitious matrix produces a composite material with relatively high tension and compressive properties as compared to steel-reinforced structures fabricated from a standard concrete mix. Although these composite systems are somewhat similar, the methods used to analyze steel-reinforced composites often fail to characterize the behavior of their more advanced graphite-reinforced counterparts. This Technical Memorandum describes some of the analytical methods being developed to determine the deflections and stresses in graphite-reinforced cementitious composites. It is initially demonstrated that the standard transform section method fails to provide accurate results when the elastic moduli ratio exceeds 20. An alternate approach is formulated by using the rule of mixtures to determine a set of effective material properties for the composite. Tensile tests are conducted on composite samples to verify this approach. When the effective material properties are used to characterize the deflections of composite beams subjected to pure bending, an excellent agreement is obtained. Laminated composite plate theory is investigated as a means for analyzing even more complex composites, consisting of multiple graphite layers oriented in different directions. In this case, composite beams are analyzed using the laminated composite plate theory with material properties established from tensile tests. Then, finite element modeling is used to verify the results. Considering the complexity of the samples, a very good agreement is obtained.

Vaughan, R. E.↗

Report on FY 2020 creep, fatigue and creep fatigue testing of Alloy 709 base metal at ORNL

The testing activities and research in support of ASME Code qualification of Alloy 709, an advanced austenitic steel, are being carried out at Oak Ridge National Laboratory (ORNL), Argonne National Laboratory, and Idaho National Laboratory. This report summarizes the status and results of FY 2020 planned testing at ORNL. Uniaxial tensile tests on the electroslag remelt (ESR) solution-annealed plate (heat number 58776-3RBC) with additional heat treatment were performed for the baseline mechanical properties evaluation for ASME code qualification of Alloy 709. The tensile properties were found to meet ASME SA-213 specifications and were comparable to the Nippon Steel NF709 data generated for an ASME Section I Code Case for seamless tubing. ORNL was tasked to carry out a subset of the Code Case testing for creep rupture. Creep rupture data from 18 tests were generated on a solution-annealed ESR plate with a solution annealing temperature of 1100°C. There are total of 19 intermediate and long-term creep rupture tests of Alloy 709 ongoing at ORNL. A preliminary fatigue design curve at 760°C was developed for Alloy 709, and the results show that the fatigue design curve of Alloy 709 is comparable to that of Alloy 800H at 760°C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Report on Evolution of Inconel 718 Following HFIR Irradiation

The report presents the microstructure and mechanical properties of 3D printed Inconel 718 after irradiation in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) to assess its potential use as a structural material. The structural components near the outlets of several proposed reactor cores will experience significant neutron fluxes and outlet coolant temperatures ranging from the hot standby temperature of 300 °C to nearly 550 °C at the center of the part. These components must support the core in appropriate loading conditions and require structural analysis at relevant temperatures. In FY21, three heat treatments were designed and conducted to simplify the microstructure and to determine how each precipitating phase contributed to the overall strength. In FY21, baseline mechanical properties were measured from uniaxial tensile tests on subsize SS-J2 specimens at room temperature and at elevated temperatures of 300, 450, and 600 °C to serve a comparison to the irradiated properties. Four capsules containing 3D printed Inconel 718 were inserted into HFIR in FY21 for a matrix of two temperatures and two doses. The lower of the two doses was available for characterization in FY22. Multiple heat treatments of Inconel 718 irradiated to nominal conditions of 2 displacements per atom (dpa) at either 300 or 600 °C were strained with uniaxial tensile tests at the Irradiated Material Examination and Testing (IMET) Facility to discern the mechanical properties. Transmission electron microscopy was performed to correlate the observed mechanical properties with nanoscale features. The initially homogenous AM718-HM increased in strength at both irradiation temperatures based on a high density of nanometer-scale radiation-induced cavities at lower temperature and nucleation and growth of γ" precipitates at higher temperatures. The precipitate-hardened AM718-HT2 showed very small differences in strength before and after irradiation: the contribution to strength from γ" precipitates was replaced with dislocation loops. Because the radioactivity of the nickel superalloys from neutron activation limited the scope of the analysis, a feasibility study examined the possibility of an ultra-miniature specimen geometry, colloquially SS-Tiny (SS-T), for mechanical property determination using the nonirradiated Inconel 718. This study found an overestimation of ductility from the SS-T geometry with yield strength and ultimate tensile strength slightly above the SS-J2 geometry: this could be contributed to a reduction in specimen thickness.

36 MATERIALS SCIENCE↗