Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The QWIP Focal Plane Assembly for NASA's Landsat Data Continuity Mission

The Thermal Infrared Sensor (TIRS) is a QWIP based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a dual channel far infrared imager with the two bands centered at 10.8[mu]m and 12.0[mu]m. The focal plane assembly (FPA) consists of three 640x512 GaAs Quantum Well Infrared Photodetector (QWIP) arrays precisely mounted to a silicon carrier substrate that is mounted on an invar baseplate. The two spectral bands are defined by bandpass filters mounted in close proximity to the detector surfaces. The focal plane operating temperature is 43K. The QWIP arrays are hybridized to Indigo ISC9803 readout integrated circuits (ROICs). Two varieties of QWIP detector arrays are being developed for this project, a corrugated surface structure QWIP and a grating surface structure QWIP. This paper will describe the TIRS system noise equivalent temperature difference sensitivity as it affects the QWIP focal plane performance requirements: spectral response, dark current, conversion efficiency, read noise, temperature stability, pixel uniformity, optical crosstalk and pixel yield. Additional mechanical constraints as well as qualification through Technology Readiness Level 6 (TRL 6) will also be discussed.

Jhabvala, M↗

Application of Laser Induced Fluorescence for flow diagnostics in arc jets

Laser Induced Fluorescence (LIF) studies are carried out on copper atoms, nitric oxide and oxygen molecules in the arc jet flows at the NASA Johnson Space Center Reentry Simulation Testing Facility. Measurements are taken in the free stream and from a blunt body shock layer. Tests are performed under different flow conditions to determine the feasibility and sensitivity of the LIF technique for various species. The LIF technique is developed as a part of high enthalpy flow diagnostics and will be useful to elucidate the rotational and vibrational temperatures. Adequate sensitivity for the detection of O2 and NO is demonstrated. Preliminary experiments for temperature and velocity measurements using copper as a tracer material are shown to be a useful new application of the laser resonant Doppler scattering technique.

Arepalli, Sivaram↗

Heated Surface Temperatures Measured by Infrared Detector in a Cascade Environment

Investigators have used infrared devices to accurately measure heated surface temperatures. Several of these applications have been for turbine heat transfer studies involving film cooling and surface roughness, typically, these measurements use an infrared camera positioned externally to the test section. In cascade studies, where several blades are used to ensure periodic flow, adjacent blades block the externally positioned camera's views of the test blade. To obtain a more complete mapping of the surface temperatures, researchers at the NASA Glenn Research Center fabricated a probe with an infrared detector to sense the blade temperatures. The probe size was kept small to minimize the flow disturbance. By traversing and rotating the probe, using the same approach as for total pressure surveys, one can find the blade surface temperatures. Probe mounted infrared detectors are appropriate for measuring surface temperatures where an externally positioned infrared camera is unable to completely view the test object. This probe consists of a 8-mm gallium arsenide (GaAs) lens mounted in front of a mercury-cadmium-zinc-tellurium (HgCdZnTe) detector. This type of photovoltaic detector was chosen because of its high sensitivity to temperature when the detector is uncooled. The particular application is for relatively low surface temperatures, typically ambient to 100 C. This requires a detector sensitive at long wavelengths. The detector is a commercial product enclosed in a 9-mm-diameter package. The GaAs lens material was chosen because of its glass-like hardness and its good long-wavelength transmission characteristics. When assembled, the 6.4-mm probe stem is held in the traversing actuator. Since the entire probe is above the measurement plane, the flow field disturbance in the measurement plane is minimized. This particular probe body is somewhat wider than necessary, because it was designed to have replaceable detectors and lenses. The signal for the detector is fed through the hollow probe body. The detector's signal goes to an externally mounted preamplifier. The detector assembly, along with a preamplifier, is calibrated as a function of the surface temperature for various detector temperatures. The output voltage is a function of both the detector and object temperatures.

Boyle, Robert J.↗

Temperature Measurements in the Solar Transition Region Using N III Line Intensity Ratios

UV emission from B-like N and O ions a rather rare opportunity for recording spectral lines in a narrow wavelength range that can potentially be used to derive temperatures relevant to the solar transition region. In these ions, the line intensity ratios of the type (2s2p(sup 2) - 2p(sup 3)) / (2s(sup 2)2p - 2s2p(sup 2)) are very sensitive to the electron temperature. Additionally, the lines involving the ratios fall within a range of only - 12 A; in N III the lines fall in the 980 - 992 A range and in O IV in the 780 - 791 A range. In this work, we explore the use of these atomic systems, primarily in N III, for temperature diagnostics of the transition region by analyzing UV spectra obtained by the Solar Ultraviolet Measurements of Emitted Radiation (SUMER) spectrometer flown on the Solar and Heliospheric Observatory (SOHO). The N III temperature-sensitive line ratios are measured in more than 60 observations. Most of the measured ratios correspond to temperatures in the range 5.7x10(exp 4) - 6.7x10(exp 4) K. This range is considerably lower than the calculated temperature of maximum abundance of N III, which is approx. 7.6x10(exp 4) K. Detailed analysis of the spectra further indicates that the measured ratios are probably somewhat overestimated due to resonant scattering effects in the 2s(sup 2)2p - 2s2p(sup 2) lines and small blends in the 2s2p(sup 2) - 2p3 lines. Actual lower ratios would only increase the disagreement between the ionization balance calculations and present temperature measurements based on a collisional excitation model. In the case of the O IV spectra, we determined that due to the close proximity in wavelength of the weak line (2s2p(sup 2)-2p3 transitions) to a strong Ne VIII line, sufficiently accurate ratio measurements cannot be obtained. Subject headings: atomic data --- atomic processes --- Sun: transition region --- Sun: U V radiation --- techniques: spectroscopic

Doron, R.↗

Sensitivity of the equilibrium surface temperature of a GCM to systematic changes in atmospheric carbon dioxide

The equilibrium response of surface temperature to atmospheric CO2 concentration, for six values between 100 and 1000 ppm, is calculated from a series of GCM experiments. This response is nonlinear, showing greater sensitivity for lower values of CO2 than for the higher values. It is suggested that changes in CO2 concentration of a given magnitude (e.g., 100 ppm) played a larger role in the Pleistocene ice-age-type temperature variations than in causing global temperature changes due to anthropogenic increases.

Oglesby, Robert J.↗

Sensitivity of Low Tropospheric Arctic Temperatures to Assimilation of AIRS Cloud-Cleared Radiances: Impact on Mid-Latitude Waves

In this work, it is shown that the prediction of individual mid-latitude waves in a global forecast framework is sensitive to the initialization over the Arctic and may benefit from the assimilation of cloud-cleared radiances (CCRs) from the Atmospheric Infrared Sounder (AIRS), particularly in partially cloudy regions with active dynamics. This study shows that the assimilation of AIRS CCRs over the Arctic Ocean, providing more information than clear-sky radiances from areas affected by broken low-level stratus clouds, produces slightly cooler low-level temperatures and lower mid-tropospheric height through hydrostatic adjustment. In areas that are data void, as observed by clear-sky radiances, and dynamically active, the assimilation of CCRs provides valuable information that can improve the representation of individual baroclinic waves and their subsequent forecasts. The modifications induced by the assimilation of AIRS CCRs over the Arctic Ocean slightly modifies the geopotential height gradients between the Arctic and the mid-latitudes, leading to potential improvements in the forecast of individual baroclinic waves as is shown through a case study. The observing system experiment (OSE) is performed with the NASA Goddard Earth Observing System (GEOS) data assimilation and forecast system during boreal autumn 2014. AIRS CCRs are thinned to approximately one quarter the density of operationally assimilated AIRS radiances, consistent with their higher information content. Global, 6-hourly analyses are produced from 1 September to 10 November 2014 and 7-day forecasts are initialized at 0000 UTC daily. Since the CCR methodology is widely applicable, these findings are also relevant to other infrared sensors.

Cloud-clearing↗

Optical Fibers Would Sense Local Temperatures

Proposed fiber-optic transducers measure local temperatures. Includes lead-in and lead-out lengths producing no changes in phase shifts, plus short sensing length in which phase shift sensitive to temperature. Phase shifts in two-mode fibers vary with temperatures.

Egalon, Claudio O.↗

Recent trends in stratospheric ozone - Implications of ozone and temperature correlation

The relation between ozone and temperature in the upper stratosphere is used to estimate the drift in the SBUV spectrometer on Nimbus-7 and the linear trend in ozone from 1979 to 1986. The ozone and temperature variabilities are coupled through chemical and dynamical processes. In the upper stratosphere they are anticorrelated through temperature-dependent loss rates, while in the lower stratosphere their variabilities are positively correlated through dynamical coupling. These relations are used to determine the ozone sensitivity to temperature and ozone trends in terms of temperature trends. It is shown that in the upper stratosphere (approximately 2 mbar), the eight-year trend in ozone is a manifestation of dynamical perturbations. It varies from about +4 percent at the equator to about -1 to -2 percent at high latitudes in both hemispheres.

Chandra, S.↗

Wide Temperature Characteristics of Transverse Magnetically Annealed Amorphous Tapes for High Frequency Aerospace Magnetics

100 kHz core loss and magnetization properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 to 150 C, at selected values of B(sub peak). For B-fields not close to saturation, the core loss is not sensitive to temperature in this range and is as low as seen in the best MnZn power ferrites at their optimum temperatures. Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, at B(sub peak) = 0.1 T and 50 C only. A linear permeability model is used to interpret and present the magnetization characteristics and several figures of merit applicable to inductor materials arc reviewed. This linear modeling shows that, due to their high permeabilities, these cores must he gapped in order to make up high Q or high current inductors. However, they should serve well, as is, for high frequency, anti ratcheting transformer applications.

Niedra, Janis M.↗

Correlation of Rupture Life, Creep Rate, and Microstructure for Type 304 Stainless Steel

The stress and temperature sensitivites of the rupture life and secondary creep rate were examined in detail for a single heat of type 304 stainless steel (9T2796). Assuming that the rupture life has a power law stress dependency, relatively small differences in the stress exponent were observed over a broad range of stress and temperature. In contrast, large changes were observed for equivalent parameter for secondary creep rate. As a result of these differences, the Monkman-Grant correlation was sensitive to stress and temperature below 650 C. Metallurgical studies based on light and transmission electron microscopy suggested that the temperature and stress sensitivities of secondary creep rate at temperatures below 650 C were related to features of the substructure not present at higher temperature. Specifically, the presence of a fine dislocation network stabilized by precipitates altered the stress and temperature sensitivities relative to what might be expected from high temperature studies.

Swindeman, R. W.↗

A novel electron tunneling infrared detector

The pneumatic infrared detector, originally developed by Golay in the late 1940s, uses the thermal expansion of one cm(exp 3) of xenon at room temperature to detect the heat deposited by infrared radiation. This detector was limited by thermal fluctuations within a 10 Hz bandwidth, but suffered from long thermal time constants and a fragile structure. Nevertheless, it represents the most sensitive room temperature detector currently available in the long wavelength infrared (LWIR). Fabrication of this type of detector on smaller scales has been limited by the lack of a suitably sensitive transducer. Researchers designed a detector based on this principle, but which is constructed entirely from micromachined silicon, and uses a vacuum tunneling transducer to detect the expansion of the trapped gas. Because this detector is fabricated using micromachining techniques, miniaturization and integration into one and two-dimensional arrays is feasible. The extreme sensitivity of vacuum tunneling to changes in electrode separation will allow a prototype of this detector to operate in the limit of thermal fluctuations over a 10 kHz bandwidth. A calculation of the predicted response and noise of the prototype is presented with the general formalism of thermal detectors. At present, most of the components of the prototype have been fabricated and tested independently. In particular, a characterization of the micromachined electron tunneling transducer has been carried out. The measured noise in the tunnel current is within a decade of the limit imposed by shot noise, and well below the requirements for the operation of an infrared detector with the predicted sensitivity. Assembly and characterization of the prototype infrared detector will be carried out promptly.

Kenny, T. W.↗

Wide Temperature Core Loss Characteristics of Transverse Magnetically Annealed Amorphous Tapes for High Frequency Aerospace Magnetics

100 kHz core loss properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 C to 150 C, at selected values of B(sub peak). For B-fields not close to saturation, the core loss is not sensitive to temperature in this range and is as low as seen in the best MnZn power ferrites at their optimum temperatures. Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, but at B(sub peak) = 0.1 T and 50 C only. For example, the 100 kHz specific core loss ranged from 50 - 70 mW/cubic cm for the 3 materials, when measured at 0.1 T and 50 C. This very low high frequency core loss, together with near zero saturation magnetostriction and insensitivity to rough handling, makes these amorphous ribbons strong candidates for power magnetics applications in wide temperature aerospace environments.

Niedra, Janis M.↗

Development and Testing of Pulse Guns for Combustion Instability Testing

To test liquid rocket engines (LREs) for combustion instabilities, devices such as bombs are often used to create pressure wave disturbances. Bombs, while effective, are inherently dangerous, expensive, and difficult to procure. Over the years, pulse guns have been used as a safer and more cost-effective way to generate controlled pressure disturbances in engine chambers. In anticipation of the need for stability testing of prototype LREs at NASA Marshall Space Flight Center (MSFC), a set of pulse guns have been designed, fabricated, tested, and characterized. The pulse gun program is funded by the RS-25 Engine Program managed out of MSFC and funded by NASA’s Space Launch System (SLS) through the MSFC Liquid Engines Office (LEO). A pulse gun is a simple device – like a traditional gun, it has a breech and barrel section. However, unlike a traditional gun, there is no bullet, as the purpose of the pulse gun is strictly to fire a high pressure pulse. Instead of a firing pin and primer that would normally be used in a traditional gun, an initiator is used to activate the gun powder. The initiator is a highly reliable pyrotechnic initiator. For this study, clone versions of the NASA Standard Initiator (NSI) were used. The initiator is used to ignite a pre-measured amount of gun powder loaded into the breech. When the pressure of the burnt gun powder exceeds the set point of a downstream burst disk, the disk ruptures, allowing the high pressure pulse to travel downstream through the barrel section. A ballistic pressure transducer located in the breech section is used to measure the short duration, high pressure pulse. Some configurations of the pulse gun have barrel sections that include one or more additional ballistic pressure transducers. These additional pressure measurements help track the degradation and damping of the pulse as it travels out of the barrel section. The measurements may also be used to determine the velocity of pulse. The objective of this paper is to present the different variants of this newly-developed pulse gun and characterize performance over a range of parameters. The parameters include breech diameter, barrel length, amount of gun powder used, the way the gun powder is packed, and the pressure setting of the burst disk. There are a total of six pulse guns: three with the 0.25 inch breech and three different length barrels, and three with the 0.40 inch breech and three different length barrels. For both breech sizes, the associated barrels are referred to as standard, one-port, and two-port barrels. The standard barrel has no instrumentation and is likely the barrel that will be used for engine stability testing. The one- and two-port barrels were designed specifically for pulse gun component testing to allow measurements of the magnitude and timing of the high pressure pulse as it makes its way through the pulse gun. The burst disks tested were commercially-available burst disks designed to rupture at 8,000, 16,000, and 24,000 psid. Testing was accomplished by firing the pulse gun into a test chamber pressurized with nitrogen at about 2300 psig. A total of four Model 113B23 High frequency ICP® pressure sensors (10k psi) were mounted in the test chamber, in the same plane as the pulse gun. Two of the sensors had “trimmed” adapters, and two did not. Given the symmetrical configuration of the sensors within the test chamber, different amplitudes of pressure measurements are attributed to the use of trimmed versus untrimmed adapters. The untrimmed adapters, with their narrower passages, tended to amplify the pressure amplitudes by as much as 50%. In total, 41 pulse gun tests have been conducted.Data are still being analyzed, but some trends are apparent. For example, measurements taken within the pulse gun are shown in Figures 3 and 4 for Hot-fires (HFs) # 11 and 39, respectively. Both tests were identical in that the 0.40 inch ID breech, two-port barrel, 8,000 psid burst disk, and same amount of gunpowder (6.639 grains for HF# 11, and 6.576 grains for HF# 39) were used, and the back pressure in the nitrogen test chamber was ~2300 psig. Despite keeping all these variables constant, the results from these two tests look quite different. For both tests, the first pressure peak shown in the P2111 trace within the breech is the firing of the initiator. The second peak and any subsequent peaks are from the combustion of the gunpowder. It should be noted that because the sensors are dynamic, the ~2300 psig baseline static pressure is not shown in the figures. For HF# 11, the burst disk clearly ruptured in a little over 0.1 ms from the time the initiator was fired. This is evident from the abrupt rise in pressure for P2112 followed by another abrupt rise in pressure for P2113. The sensors track the movement of the high pressure pulse through the pulse gun. For HF# 39, however, there was nearly 1 ms delay between the initiator firing and the burst disk rupturing. The only difference between these two tests was the way in which the gunpowder was packed within the breech. For HF# 11, the gunpowder was poured directly into the breech, atop the initiator, and held in place with a vegetable fiber wad appropriately sized for the barrel diameter. Once in place, the wad firmly held the gunpowder in place. For HF# 39, the gunpowder was rolled within cigarette paper with the ends of the paper twisted. The rolled gunpowder was gently pushed down into the breech, toward the initiator, and no wad was used. This method of loading the gunpowder consistently produced longer delays in the rupture of the burst disk, presumably because there was a steady, fuller burning of the gunpowder. The burst disk was rated for 8,000 psid, which means that the burst disk should not have opened until the pressure in the breech reached ~10,300 since there was ~2300 psig back pressure in the test chamber. In the case of HF# 11, the breech pressure only reached roughly 4200 psi before there was leakage either through or past the burst disk, but for HF#39, the breech pressure reached 10,600 psi prior to the burst disk opening. The temperature of the burst disk is certainly a factor in determining when the burst disk will rupture. A sharp rise in the burst disk temperature could weaken it and cause it to stray from the designed set point burst pressure. The burst disks are manufactured of Inconel to try to reduce their sensitivity to temperature, but how the burst disks perform above 900°F is not documented. All burst disks were engineered and tested by the manufacturer for ambient temperature conditions. One theory for why rolling the gunpowder in cigarette paper may produce better results is related to a more controlled temperature environment. The cigarette paper may act as a sheath that protects the burst disk from excessive temperatures during the rapid buildup of pressure in the breech. The ultimate benefit of not breeching the burst disk prematurely is shown in Figures 5 and 6, which graphs the resultant pressure pulse produced in the test chamber. For HF #11, the peak pressure on the P2123 trimmed adapter is about 270 psi, while for HF# 39 it is 343 psi, which is about 1.27 times greater in magnitude. In either case, the pressure pulse is ~20 μs in width once it reaches the test chamber. Another pressure rise about 100 μs later can be seen on the sensors located across from the pulse gun port, P2124 and P2121. These pressures are lower due to attenuation of the pressure wave as it moves across the test chamber. After the wave encounters the wall, it reflects back and forth within the chamber until it completely dissipates.

Pulse Gun↗

Demonstration of the feasibility of laser induced fluorescence for arc jet flow diagnostics

Laser Induced Fluorescence (LIF) studies are carried out on nitric oxide and oxygen molecules in the arc jet flows at the NASA Johnson Space Center Reentry Testing Facility. Measurements are taken in the free stream and from a blunt body shock layer. Tests are performed under different flow conditions to determine the feasibility and sensitivity of the LIF technique for various species. This is developed as a part of high enthalpy flow diagnostics and will be useful to elucidate the rotational and vibrational temperatures. Adequate sensitivity for the detection of O(2) and NO is demonstrated. Proposed improvements of the existing system are presented.

Arepalli, Sivaram↗

Two-dimensional finite-element temperature variance analysis

The finite element method is extended to thermal analysis by forming a variance analysis of temperature results so that the sensitivity of predicted temperatures to uncertainties in input variables is determined. The temperature fields within a finite number of elements are described in terms of the temperatures of vertices and the variational principle is used to minimize the integral equation describing thermal potential energy. A computer calculation yields the desired solution matrix of predicted temperatures and provides information about initial thermal parameters and their associated errors. Sample calculations show that all predicted temperatures are most effected by temperature values along fixed boundaries; more accurate specifications of these temperatures reduce errors in thermal calculations.

Heuser, J. S.↗

The role of large-scale eddies in the climate equilibrium. I - Fixed static stability

An efficient two-level model on a sphere that is based on the balance equations with fixed static stability is developed and used to study how eddies arising from baroclinic instability interact with the temperature structure. The model gives a much better simulation of the eddy momentum flux and of the total eddy forcing of the zonal-mean temperature and zonal wind fields than do quasi-geostrophic beta-plane models. Nonetheless, the results are qualitatively similar. The midlatitude eddy regimes range between two extreme cases. In one, the eddies have no effect on the temperature and zonal wind fields, and in the other (similar to the observed atmosphere), the eddy forcing of the temperature and zonal wind fields is dominated by the eddy heat flux. Quantitatively, some of the model's results differ significantly from those based on the quasi-geostrophic beta-plane. For example, the temperature structure is much more sensitive to the external forcing, and the eddy heat flux is less sensitive to the temperature structure.

Zhou, Shuntai↗

Time-dependent edge notch sensitivity of Inconel 718 sheet in the temperature range 900 to 1400 F (482 to 760 C)

Time-dependent notch sensitivity of Inconel 718 sheet occurred at 900 to 1200 F when notched specimens were loaded below the yield strength, and tests on smooth specimens showed that small amounts of creep consumed large fractions of creep-rupture life. The severity of the notch sensitivity decreased with decreasing solution treatment temperature and increasing time and/or temperature of the aging treatment. Elimination of the notch sensitivity was correlated with a change in the dislocation mechanism from shearing to by-passing precipitate particles.

Wilson, D. J.↗