Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The intense slow positron beam facility at the PULSTAR reactor and applications in nano-materials study

An intense slow positron beam has been established at the PULSTAR nuclear research reactor of North Carolina State University. The slow positrons are generated by pair production in a tungsten moderator from gammarays produced in the reactor core and by neutron capture reactions in cadmium. The moderated positrons are electrostatically extracted and magnetically guided out of the region near the core. Subsequently, the positrons are used in two spectrometers that are capable of performing positron annihilation lifetime spectroscopy (PALS) and positron Doppler broadening spectroscopy (DBS) to probe the defect and free volume properties of materials. One of the spectrometers (e{sup +}-PALS) utilizes an rf buncher to produce a pulsed beam and has a timing resolution of 277 ps. The second spectrometer (Ps-PALS) uses a secondary electron timing technique and is dedicated to positronium lifetime measurements with an approximately 1 ns timing resolution. PALS measurements have been conducted in the e{sup +}-PALS spectrometer on a series of nano-materials including organic photovoltaic thin films, membranes for filtration, and polymeric fibers. These studies have resulted in understanding some critical issues related to the development of the examined nano-materials.

43 PARTICLE ACCELERATORS↗

Infrared compatible rapid mixer to probe millisecond chemical kinetics

Fast microfluidic mixers are a valuable tool for studying solution-phase chemical reaction kinetics and molecular processes with spectroscopy. However, microfluidic mixers that are compatible with infrared vibrational spectroscopy have seen only limited development due to the poor infrared transparency of the current microfabrication material. We describe the design, fabrication, and characterization of CaF2-based continuous flow turbulent mixers, which are capable of measuring kinetics in the millisecond time window with infrared spectroscopy, when integrated into an infrared microscope. Kinetics measurements demonstrate the ability to resolve relaxation processes with 1 millisecond time resolution, and straightforward improvements are described that should result in sub-100 µs time-resolution.

Instruments & Instrumentation↗

A study of the cosmic sources of hard X-rays

An actively-shielded, high-energy X-ray telescope was launched onboard OSO-8 on 21 June 1975. The primary objectives of this experiment are the measurements of the energy spectrum of discrete cosmic X-ray sources in the range 20 keV to 3 MeV and of the temporal variations in the intensity of each source detected with a time resolution of 0.3 msec. This detector provides the highest duty factor and the finest time resolution of any of its kind for observations over a period of up to 10 days. The background spectrum of this detector in orbit was monitored continuously since shortly after launch. The minimum detectable source strength is estimated to be between 10,000 and 100,000 photons/sq-cm-sec keV, limited primary by the effects of induced radioactivity. From 16 July through 18 July 1975, the X-ray binary, Cen X-3, was observed with the hard X-ray telescope.

Dennis, B. R.↗

UWB Tracking Algorithms: AOA and TDOA

Ultra-Wideband (UWB) tracking prototype systems are currently under development at NASA Johnson Space Center for various applications on space exploration. For long range applications, a two-cluster Angle of Arrival (AOA) tracking method is employed for implementation of the tracking system; for close-in applications, a Time Difference of Arrival (TDOA) positioning methodology is exploited. Both AOA and TDOA are chosen to utilize the achievable fine time resolution of UWB signals. This talk presents a brief introduction to AOA and TDOA methodologies. The theoretical analysis of these two algorithms reveal the affecting parameters impact on the tracking resolution. For the AOA algorithm, simulations show that a tracking resolution less than 0.5% of the range can be achieved with the current achievable time resolution of UWB signals. For the TDOA algorithm used in close-in applications, simulations show that the (sub-inch) high tracking resolution is achieved with a chosen tracking baseline configuration. The analytical and simulated results provide insightful guidance for the UWB tracking system design.

Ni, Jianjun David↗

A zone-level occupancy counting system for commercial office spaces using low-resolution time-of-flight sensors

Understanding the locations of occupants in a commercial built environment is critical for realizing energy savings by delivering lighting, heating, and cooling only where it is needed. In this paper, we present an indoor occupancy counting system using a sparse array of inexpensive, low-resolution, and privacy-preserving time-of-flight sensors. We develop and validate an algorithm for zonal occupancy counting that can deal with multiple people walking underneath the sensors in arbitrary directions, and evaluate the system both in realistic simulations of office spaces and in a real-world installation. Finally, we found that our system has an error rate of around 0.4%, resulting in highly accurate person localization and zone counting using only a few sensors per space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rapid spectral and flux time variations in a solar burst observed at various dm-mm wavelengths and at hard X-rays

A solar burst was observed with high sensitivity and time resolution at cm-mm wavelengths by two different radio observatories (Itapetinga and Algonquin), with high spectral time resolution at dm-mm wavelengths by patrol instruments (Sagamore Hill), and at hard X-rays (HXM Hinotori). At the onset of the major burst time structure there was a rapid rise in the spectral turnover frequency (from 5 to 15 GHz), in about 10s, coincident to a reduction of the spectral index in the optically thin part of the spectrum. The burst maxima were not time coincident at the optically thin radio frequencies and at the different hard X-ray energy ranges. The profiles at higher radio frequencies exhibited better time coincidence to the high energy X-rays. The hardest X-ray spectrum (-3) coincided with peak radio emission at the higher frequency (44 GHz). The event appeared to be built up by a first major injection of softer particles followed by other injections of harder particles. Ultrafast time structures were identified as superimposed on the burst emission at the cm-mm high sensitivity data at X-rays, with predominant repetition rates ranging from 2.0 to 3.5 Hz.

Zodivaz, A. M.↗

Coherent femtosecond low-energy single-electron pulses for time-resolved diffraction and imaging: A numerical study

We numerically investigate the properties of coherent femtosecond single electron wave packets photoemitted from nanotips in view of their application in ultrafast electron diffraction and non-destructive imaging with low-energy electrons. For two different geometries, we analyze the temporal and spatial broadening during propagation from the needle emitter to an anode, identifying the experimental parameters and challenges for realizing femtosecond time resolution. The simple tip-anode geometry is most versatile and allows for electron pulses of several ten of femtosecond duration using a very compact experimental design, however, providing very limited control over the electron beam collimation. A more sophisticated geometry comprising a suppressor-extractor electrostatic unit and a lens, similar to typical field emission electron microscope optics, is also investigated, allowing full control over the beam parameters. Using such a design, we find {approx}230 fs pulses feasible in a focused electron beam. The main limitation to achieve sub-hundred femtosecond time resolution is the typical size of such a device, and we suggest the implementation of more compact electron optics for optimal performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collisional and Radiative Effects in Transient sub-Doppler Hole Burning: Double Resonance Measurements in CN

We report transient hole-burning and saturation recovery measurements in the CN radical with MHz frequency resolution and 20 ns time resolution. Narrow velocity groups of individual hyperfine levels of selected rotational states in CN (X{sup 2} {Sigma}{sup +}) are depleted and excited (A{sup 2}{pi}{sub i}) with a saturation laser and probed by a counterpropagating, frequency modulated probe beam. Recent work in our lab has used this method to measure and characterize the hyperfine splittings for a set of rotational, fine structure, and parity components of CN (A{sup 2}{pi}{sub i}, v=1). Extending this work, we report time and frequency dependence of the saturation signals following abrupt switching of the CW saturation beam on and off with an electro-optic amplitude modulator. Recovery of the unsaturated absorption following the turnoff of the saturation beam follows pressure-dependent kinetics, driven by collisions with the undissociated NCCN precursor with a rate coefficient of 2 x 10{sup -9} cm{sup 3} s{sup -1} molec{sup -1}. Similar recovery kinetics are observed for two-level saturation resonances, where the signal observed is a combination of X- and A-state kinetics, as well as for three-level crossover resonances, which can be chosen to probe selectively the holefilling in the X state or the decay of velocity-selected A state radicals. The observed recovery rates are 8-10 times faster than the estimated rotationally inelastic contribution. The observed recovery rates are likely dominated by velocity-changing collisions in both X and A states, occurring with similar rates, despite the large difference in the properties of these electronic states. Transient signal risetimes following the turning on of the saturation pulse are consistent with the expected Rabi frequency. At lower pressures ({approx}50 mTorr) and higher beam power ({approx}200 mW), we can observe multiple Rabi cycles before collisions disrupt the coherent excitation and the transient signal reaches a steady state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A simple model for estimating changes in rainfall erosivity caused by variations in rainfall patterns

Highlights: • A simple relationship was developed for predicting daily erosivity in changing climates. • The relationship depends on precipitation amount and maximum 0.5-h intensity I{sub 0.5} . • The relationship was calibrated using measured climate data and had a R{sup 2} of 0.99. • Simulated daily and annual erosivities were predicted with a R{sup 2} of 0.99 using the relationship. • The relationship was tested using I{sub 24}, showing a R{sup 2} of 0.78 for the simulated data. A major challenge when coupling soil loss models with precipitation forecasts from Global Circulation Models (GCMs) is that their time resolutions do not generally agree. Precipitation forecasts from GCM must be scaled down; however, the distribution of the rainfall intensity, which can affect soil loss as much as precipitation amounts, is usually not considered in this process. Therefore, the objective of this study was to develop a statistical equation for computing event-based rainfall erosivity under changing precipitation patterns using the least amount of information possible. For this purpose, an empirical equation for predicting event-based rainfall erosivity was developed using the product of the total precipitation P and the maximum 0.5-h rainfall intensity, I{sub 0.5}. This equation was calibrated using measured precipitation data from 28 sites in Central Chile and then tested with simulated data with different rainfall patterns from the CLIGEN (CLImate GENerator) weather generator. More than 53,000 rainfall events were analyzed, where the equation consistently provided R{sup 2} values of 0.99 for every dataset used, revealing its robustness when used in potential climate change scenarios in the study site. However, because computing I{sub 0.5} requires estimating precipitation at a high time resolution, the relationship was recalibrated and tested using 1 through 24-h maximum rainfall intensities. Using these intensities, the equation provided erosivity estimates with R{sup 2} ranging from 0.78 to 0.99, where better results were obtained as the resolution of the data increased. This study provides the methodology for building and testing the proposed equation and discusses its advantages and limitations.

54 ENVIRONMENTAL SCIENCES↗

The SCOPE Mission

In order to reach the new horizon of the space physics research, the Plasma Universe, via in-situ measurements in the Earth's magnetosphere, SCOPE will perform formation flying observations combined with high-time resolution electron measurements. The simultaneous multi-scale observations by SCOPE of various plasma dynamical phenomena will enable data-based study of the key space plasma processes from the cross-scale coupling point of view. Key physical processes to be studied are magnetic reconnection under various boundary conditions, shocks in space plasma, collisionless plasma mixing at the boundaries, and physics of current sheets embedded in complex magnetic geometries. The SCOPE formation is made up of 5 spacecraft and is put into the equatorial orbit with the apogee at 30 Re (Re: earth radius). One of the spacecraft is a large mother ship which is equipped with a full suite of particle detectors including ultra-high time resolution electron detector. Among other 4 small spacecraft, one remains near ({approx}10 km) the mother ship and the spacecraft-pair will focus on the electron-scale physics. Others at the distance of 100{approx}3000 km(electron{approx}ion spatial scales) from the mother ship will monitor plasma dynamics surrounding the mother-daughter pair. There is lively on-going discussion on Japan-Europe international collaboration (ESA's Cross-Scale), which would certainly make better the coverage over the scales of interest and thus make the success of the mission, i.e., clarifying the multi-scale nature of the Plasma Universe, to be attained at an even higher level.

79 ASTRONOMY AND ASTROPHYSICS↗

A MRPC prototype for SOLID-TOF in Jlab

A prototype of Multi-gap Resistive Plate Chamber (MRPC) for the future SoLID time of flight system at JLab has been developed. The counter, trapezoidal in shape, is assembled with the newly developed low-resistive Chinese glass. It has 10 × 0.25 mm gas gaps and 11 readout strips of different lengths. The strip width is 2.5 cm with a strip-to-strip interval of 3 mm. Preliminary tests performed with cosmic-rays showed an efficiency higher than 95% and a time resolution around 50 ps. Results under diffuse/uniform irradiation performed at JLab with scattered high energy electrons showed a time resolution of 70–80 ps and over-95% efficiency up to an incoming flux of 15 kHz/cm{sup 2}. These performances meet the requirements of the new time of flight system SoLID-TOF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for X-Ray Emission in the Nearest Known Brown Dwarf

The XMM observation were obtained on 2001 January 07-08 for 51767 s. The Optical Monitor (OM) was used with the V filter for 4 exposures of 5000 s each in imaging mode. We used the data given by the OM to confirm the presence of the source in the field of view. The European Photon Imaging Camera (EPIC) MOS 1 and MOS2 were used 48724 s each in prime full window mode with 2.5 s time resolution. The EPIC PN was used 46618 s in prime full window mode with 73.4 ms time resolution. The X-ray source closest to the expected position of our target is offset by delta R.A=2.5 arcsec and delta Dec=-28.37 arcsec. This offset is high in comparison with the 0.4 arcsec observed with the optical data. So at this point we already knew that the target was not detected. To confirm that conclusion, we performed the identification of all X-ray sources in the field of view by comparing source to source our image with the one obtained by Rutledge et al. with Chandra. This allowed us to identify all the X-ray sources in our field of view in an area of 20 arcsec times 10 arcsec centered on the expected coordinates of LP944-20. We were then able to conclude that the target was not detected during this observation. This result allowed us to determine a new and better 3 sigma upper limit of X-Ray emission for this object. We have also derived duty cycles for X-ray flares as a function of X-ray luminosity by comparing the XMM data with Chandra and ROSAT data. One student has been supported with the grant during four months (Herve Bouy). A Sun workstation was purchased for him.

Martin, Eduardo↗

EXCESS OPTICAL ENHANCEMENT OBSERVED WITH ARCONS FOR EARLY CRAB GIANT PULSES

We observe an extraordinary link in the Crab pulsar between the enhancement of an optical pulse and the timing of the corresponding giant radio pulse. At optical through infrared wavelengths, our observations use the high time resolution of ARray Camera for Optical to Near-IR Spectrophotometry, a unique superconducting energy-resolving photon-counting array at the Palomar 200 inch telescope. At radio wavelengths, we observe with the Robert C. Byrd Green Bank Telescope and the Green Bank Ultimate Pulsar Processing Instrument backend. We see an 11.3% ± 2.5% increase in peak optical flux for pulses that have an accompanying giant radio pulse arriving near the peak of the optical main pulse, in contrast to a 3.2% ± 0.5% increase when an accompanying giant radio pulse arrives soon after the optical peak. We also observe that the peak of the optical main pulse is 2.8% ± 0.8% enhanced when there is a giant radio pulse accompanying the optical interpulse. We observe no statistically significant spectral differences between optical pulses accompanied by and not accompanied by giant radio pulses. Our results extend previous observations of optical-radio correlation to the time and spectral domains. Our refined temporal correlation suggests that optical and radio emission are indeed causally linked, and the lack of spectral differences suggests that the same mechanism is responsible for all optical emission.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray attenuation measurements in a cavitating mixing layer for instantaneous two-dimensional void ratio determination

The purpose of this experimental study was to analyze a two-dimensional cavitating shear layer. The global aim of this work was to obtain a better understanding and modeling of cavitation phenomenon in a 2D turbulent sheared flow which can be considered as quite representative of cavitating rocket engine turbopomp inducers. This 2D mixing layer flow provided us a well documented test case which can be used for the characterization of the cavitation effects in sheared flows. The development of a velocity gradient was observed inside a liquid water flow: Kelvin-Helmholtz instabilities developed at the interface. Vaporizations and implosions of cavitating structures inside the vortices were observed. X-ray attenuation measurements were performed to estimate the amount of vapor present inside the mixing area. Instantaneous two-dimensional void ratio fields were acquired. The real spatial resolutions are 0.5 mm with 2000 fps and 1.5 mm with 20 000 fps. The effective time resolution is equal to the camera frame rate up to a 19% void ratio variation between two consecutive images. This seems to be sufficient in the context of the present flow configuration. The two-phase structures present inside the mixing area were analyzed at three different cavitation levels and their behaviors were compared to non-cavitating flow dynamic. Convection velocities and vortices shedding frequencies were estimated. Results show that vapor was transported by the turbulent velocity field. Statistical analysis of the void ratio signal was carried out up to the fourth order moment. This study provided a global understanding of the cavitating structure evolution and of the cavitation effects on turbulent sheared flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Project for measuring the neutron electromagnetic form factor in the reaction e{sup +}e{sup -} {yields} nn-bar at the VEPP-2000 collider

A project aimed at measuring the neutron electromagnetic form factor in the reaction e{sup +}e{sup -} {yields} nn-bar with the SND detector at the VEPP-2000 e{sup +}e{sup -} collider is presented. The results obtained for the time resolution of the NaI(Tl) counter using flash-ADC are reported along with estimates of the efficiency of separation of neutron-antineutron events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laboratory scaled simulation of lidar cloud sounding experiments

The results of lidar measurements carried out on laboratory scale models of clouds are presented. Measurements on laboratory scale models are important since one has the knowledge of the relevant parameters of the diffusing medium, such as: scattering and absorption coefficients, phase function, homogeneity, shape, etc. Knowledge of these parameters enables one to use the results to test the reliability of theoretical and numerical investigations. To obtain a laboratory scaled model of a lidar system sounding a cloud, it is necessary to scale down all the geometrical quantities by the same factor to reduce distances of the order of kilometers to the order of meters, keeping the size and the optical depth of the diffusers unchanged. If a time resolution of the order of nanoseconds is necessary for a lidar sounding actual clouds, the corresponding time resolution for the laboratory model should be of the order of picoseconds. It is possible to obtain this resolution by using picosecond laser systems and fast electrooptical detectors like the streak camera. The results of the laboratory measurements showed that the multiple scattering effect strongly depends on the size of the diffusers, as well as on the concentration. The experimental results were compared with the numerical results of a Monte Carlo code. A generally good agreement was obtained.

Zaccanti, G.↗

Search for X-Ray Emission in the Nearest Known Brown Dwarf

The XMM observations were obtained on 2001 January 07-08 for 51767 s. The Optical Monitor (OM) was used with the V filter for four exposures of 5000 s each in imaging mode. We used the data given by the OM to confirm the presence of the source in the field of view. The European Photon Imaging Camera (EPIC) MOS1 (Metal Oxide Semiconductor) and MOS2 were used 48724 s each in prime full window mode with 2.5 s time resolution. The EPIC PN was used 46618 s in prime full window mode with 73.4 ms time resolution.

Martin, Eduardo↗

First Optical Observations of Interhemispheric Electron Reflections Within Pulsating Aurora

A case study of a pulsating auroral event imaged optically at high time resolution presents direct observational evidence in agreement with the interhemispheric electron bouncing predicted by the Super Thermal Electron Transport model. Pulsation-on times are identified and subsequent equally spaced fainter pulsations are also noted and can be explained by a portion/percentage of the primary precipitating electrons reflecting upward from the ionosphere, traveling to the opposite hemisphere and reflecting upward again. The high time resolution of these data, combined with the short duration of the pulsation-on time (approx. 1 s) and the relatively long spacing between pulsations (approx. 6 to 9 s) made it possible to observe the faint optical pulses caused by the reflected electrons coming from the opposite hemisphere.

thermal↗