Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The Autoignition of iso-Cetane: Shock Tube Experiments and Kinetic Modeling

Iso-cetane (2,2,4,4,6,8,8-heptamethylnonane, C{sub 16}H{sub 34}) is a highly branched alkane reference compound for determining cetane ratings. It is also a candidate branched alkane representative in surrogate mixtures for diesel and jet fuels. Here new experiments and kinetic modeling results are presented for the autoignition of iso-cetane at elevated temperatures and pressures relevant to combustion in internal combustion engines. Ignition delay time measurements were made in reflected shock experiments in a heated shock tube for {Phi} = 0.5 and 1.0 iso-cetane/air mixtures at temperatures ranging from 953 to 1347 K and pressures from 8 to 47 atm. Ignition delay times were measured using electronically excited OH emission, monitored through the shock tube end wall, and piezoelectric pressure transducer measurements, made at side wall locations. A new kinetic mechanism for the description of the oxidation of iso-cetane is presented that is developed based on a previous mechanism for iso-octane. Computed results from the mechanism are found in good agreement with the experimental measurements. To our knowledge, the ignition time measurements and detailed kinetic mechanism for isocetane presented here are the first of their kind.

30 DIRECT ENERGY CONVERSION↗

Real-Time XANES Measurement of Se Reduction by Zerovalent Iron in a Flow-through Cell, and Accompanying Se Isotope Measurements

An anoxic flow-through cell experiment was conducted to examine mechanisms controlling the real-time reduction of selenate (Se(VI)) by zerovalent iron (ZVI), which is commonly used in permeable reactive barriers to treat dissolved contaminants including Se(VI). Changes in selenium (Se) isotope composition were examined by increasing the influent Se concentration over time, thus changing the proportion of Se removed from solution. At the conclusion of the experiment, an anoxic Se-free solution was pumped through the cell to assess the stability of the reaction products. At all stages, X-ray absorption data were obtained from the solid phase and Se isotope data from the aqueous phase. Reduced Se in the form of adsorbed Se(IV), Fe 2 SeO 4 , Se(0), and iron selenides accumulated on the ZVI over time. A linear regression function was fit to the $δ$ 82/76 Se values of the effluent, yielding an isotopic separation of 9.6‰. A Rayleigh curve was fit to the isotope data from the effluent samples collected during the rinse stage with an effective fractionation of 2.4‰. The results from this experiment can be used to elucidate the effect of multiple concurrent mechanisms on Se isotope behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time recovery measurements using operational GOES and transit satellites

Results of regular monitoring of both the GOES and TRANSIT timing signals over a number of months at the National Bureau of Standards (NBS), Boulder, Colorado are presented. The TRANSIT results include an analysis of how received timing accuracy and stability are affected by: (1) averaging over varying numbers of satellite passes; (2) averaging over different combinations of the five available satellites; (3) using several independent receivers of the same type; and (4) application of published corrections to the received data. Based on monitoring experience to date at NBS, some pros and cons of using each of the available operational systems are discussed. Updated information on recent improvements incorporated into the GOES time code generation and monitoring system at Wallops Island, Virginia is also included.

Beehler, R. E.↗

Improved uranium isotopic ratio determinations for the liquid sampling-atmospheric pressure glow discharge orbitrap mass spectrometer by use of moving average processing

The liquid sampling-atmospheric pressure glow discharge (LS-APGD) is a versatile combined atomic and molecular (CAM) ionization source capable of ionizing elemental species, small polar compounds, low-polarity polycyclic aromatic hydrocarbons, and proteins. While the LS-APGD has been proven capable of determining the 235U/238U isotope ratio in enriched and natural uranium, recent efforts have strived to reduce the analysis time of individual measurements by employing higher-order data processing techniques, specifically, moving average methods. Additionally, the use of a moving average (of data windows of various widths) improves the precision of the ratio measurements and reduces the number of scans needed to be collected to generate high-precision results. Additionally, use of the moving average minimizes the quantity of sample that needs to be analyzed while reducing the measurement time. These reductions have allowed isotope ratio (IR) determinations to be made using injections instead of direct infusion of the analyte. For example, employing a 40-point window width in the moving average to direct infusion data reduced the percent relative standard deviation (% RSD) of the 235U/238U values from 3.4% to 0.5%. For the injection of a 100 μL aliquot, the % RSD was reduced from 5.3% to 0.7%.

74 ATOMIC AND MOLECULAR PHYSICS↗

Atmospheric velocity spectral width measurements using the statistical distribution of pulsed CO2 lidar return signal intensities

A pulsed CO2 lidar with coherent detection has been used to measure the correlation time of backscatter from an ensemble of atmospheric aerosol particles which are illuminated by the pulsed radiation. The correlation time of the backscatter of the return signal, which is directly related to the velocity spectral width, can be used to study the velocity structure constant of atmospheric turbulence and wind shear. Various techniques for correlation time measurement are discussed, and several measurement results are presented for the technique using the information contained in the statistical distribution of a set of lidar return signal intensities.

Ancellet, Gerard M.↗

JPSS-2 VIIRS version 2 at-launch relative spectral response characterization

The JPSS-2 VIIRS sensor has completed its pre-launch test program and is now awaiting launch in the 2022 timeframe. The VIIRS spectral characterization, in the form of band averaged and supporting detector level relative spectral response (RSR) for each VIIRS band, was completed in 2019 and is based upon independent SpMA dual monochromator (all bands) and GSFC GLAMR laser system (reflectance bands only) spectral measurements, including first time measurements of the VIIRS SWIR bands by a laser system. The measurements and subsequent analysis effort by subject matter experts of the VIIRS DAWG has led to the July 2019 VIIRS Version 2 RSR release, the official at-launch RSR characterization for the JPSS-2 VIIRS mission. Version 2 replaces and improves upon the August 2018 Version 1 release by incorporating the GLAMR measurements into the analysis to produce an updated “fused” RSR for reflective solar bands (M1- M10, I1-I3, DNBLGS, DNBMGS) and by applying a CO2 absorption correction to the SpMA measurements for thermal band M13. For all other bands (M11, M12, M14-M16, I4, I5), the Version 1 characterization, based entirely upon the SpMA measurements, is carried forward into the Version 2 release. An assessment on compliance with spectral performance metrics finds that VIIRS is compliant on nearly all metrics, with a few minor exceptions. The version 2 RSR release includes band average (over all detectors and subsamples) RSR plus supporting RSR for each detector and subsample, and is available under EAR99 restrictions to the science community at a restricted access NASA eRoom site.

JPSS-2↗

Feasibility of using Low-Cost COTS Sensors for Particulate Monitoring in Space Missions

Real-time measurement of particles suspended in the spacecraft cabin is of great importance to verify that maximum allowable dust concentrations are not exceeded. This is primarily to protect astronaut health, but also has implications for dust-sensitive equipment. Recently, there is growing interest in low-cost commercial off-the-shelf (COTS) particle sensors by air quality researchers for their ability to map concentrations of airborne particulate matter in various terrestrial settings. In addition to low cost (< $2,000), the compact size and minimal weight of these sensors make them a potential choice for space missions. The detection mechanism for these aerosol sensors is typically measurement of light scattered by particles as they flow through a sensing volume. The amount of scattered light for detection depends on the particle size, shape, density, and refractive index of the particle material. Ideally, particle instruments should be calibrated with reference instruments for each different type of aerosol measurement. In this study we review multiple parameters that may impact the performance of state-of-the-art low-cost aerosol sensors. Environmental factors such as temperature, relative humidity, low ambient pressure, radiation and charge environment, partial-gravity and microgravity can affect the accuracy of particle measurements. Characteristics of the dust aerosols including particle size distribution, aerosol composition, refractive index, morphology and concentration levels also affect the measurement accuracy. Finally, we look at these parameters and issues with respect to an example COTS low-cost aerosol sensor. Instrument performance specifications are evaluated, and experiments are performed to measure real-time concentrations of Arizona Road Dust (a terrestrial reference test dust) and lunar dust simulant in a laboratory chamber. Overall, this study provides insight for evaluating spacecraft particulate monitoring technologies and raises questions to be answered before incorporating low-cost COTS sensors in future space missions to dusty destinations.

lunar dust↗

Design and Testing of a Novel Wide Range - Segmented Gamma Scanner Incorporating Tomographic Gamma Scanning for Measuring Both Low and Intermediate Level Waste in Drums - 13470

This paper describes the design and testing of a novel automated Wide Range Segmented Gamma ray Scanning (WR-SGS) assay instrument that also incorporates Tomographic Gamma Scanning (TGS). The instrument is designed for the measurement of both Low and Intermediate Level Waste (LLW and ILW) in 200 litre drums and other waste containers covering a wide range of density. Like earlier ANTECH WR-SGS instruments, the system employs a single shielded and collimated high purity germanium (HPGe) detector to quantify the radionuclide content of the waste and like conventional SGS instruments it is suitable for the measurement of relatively homogeneous waste matrices. Also, like earlier WR-SGS systems the instrument incorporates an automated variable aperture collimator, which allows the vertical segment height to be adjusted in order to measure both high dose-rate and very low activity drums. The instrument employs both conventional discrete SGS vertical segment measurements as well as vertical segment measurement by continuous helical-scanning of the drum as it rotates. This latter method reduces measurement times for SGS measurements. In order to determine the density corrections for both low and high-density drums, a high activity Eu-152 transmission source is employed. When not in use, and in place of a conventional shutter mechanism, the shielded transmission source is moved to a shielded storage position to eliminate background radiation from the source. Due to its novel features, the WR-SGS is applicable to the measurement of both very low and very high activity waste drums as well as waste drums with a wide range of density. If located in a low background position and with the effective shielding of the strong transmission source, the instrument can be used to measure very low level or exempt waste. In order to extend the range of applicability to the measurement of heterogeneous drums, TGS measurement capability has been included in the basic WR-SGS design. This is achieved by adding horizontal motion to the waste drum rotation platform and incorporating TGS collimation into the variable aperture collimator, as well as a filter to reduce the detector signal when straight-through measurements are made using the strong transmission source. Test measurements are presented of the system operating in both SGS and TGS modes using different drum densities and source strengths. The test measurement results are compared with benchmarked MCNP Monte Carlo calculations. The Wide Range SGS - TGS instrument extends the range of both activity and density that can be measured in 200 and 340 litre drums. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determining water cloud particle sizes from lidar depolarization measurements and time dependent multiple scattering coefficients

We present a technique of extracting water cloud particle size information from lidar measurements in conjunction with double scattering calculations. In this presentation, we describe the technique and give examples using data taken with the Air Force Phillips Laboratory's (Geophysics Directorate) low altitude Nd:YAG, elastic backscatter lidar. In a related presentation we describe the double scattering lidar model which we developed for this work. The technique uses simultaneous measurements of two orthogonal linear polarization components of lidar returns from water clouds or other media composed of spherical particles. Any depolarization of the incident lidar radiation backscattered by such a media can only be due to multiple scattering. The amount of depolarization is dependent on the extinction coefficient and the single scatter phase matrix, both of which are functions of position in the medium. The phase matrix is dependent on the index of refraction of the particles and the particle size distribution. Our technique is a modification of a procedure presented in Reference 1. There, particle sizes of water clouds are determined from double scattering calculations together with measurements of radiation scattered from volumes outside the lidar receiver's field of view (which can only be multiply scattered radiation). The methodology of our technique is similar but our 'probe' of the scattering phase function (and thus the particle size distribution) is different.

Garner, R. C.↗

The quantum measurement of time

Traditionally, in non-relativistic Quantum Mechanics, time is considered to be a parameter, rather than an observable quantity like space. In relativistic Quantum Field Theory, space and time are treated equally by reducing space to also be a parameter. Herein, after a brief review of other measurements, we describe a third possibility, which is to treat time as a directly observable quantity.

Shepard, Scott R.↗

Time-resolved measurements of OH during auto-ignition of syngas with trimethylsilanol and hexamethyldisiloxane

The effects of trimethylsilanol (TMSO) and hexamethyldisiloxane (HMDSO) addition on OH time histories during syngas (H 2 and CO) ignition were investigated using the University of Michigan rapid compression facility. Experiments spanned temperatures of 1010–1080 K, at a pressure of approximately 5 atm. Syngas mixtures of 1.2 % H 2 /2.8 % CO/20 % O 2 by volume (balance N 2 and Ar) provided a baseline for comparison with mixtures that included 100, 200, and 1000 ppm of the TMSO and 100 ppm of HMDSO. Narrow-line ultraviolet laser-absorption was used to measure OH mole-fraction during ignition. The addition of TMSO and HMDSO significantly shifted the OH time-histories earlier in time, by up to 51 %, compared with the baseline syngas mixture. The value of the maximum OH mole fraction was consistent between the 100 and 200 ppm TMSO mixtures and the 100 ppm HMDSO mixtures, but the maximum OH increased significantly with the 1000 ppm TMSO mixtures. Here, the OH data indicate TMSO and HMDSO were not direct sources of OH radicals. Analysis further indicates the TMSO and HMDSO decompose rapidly followed by reactions that enhance the production of H atoms, and the increased reactivity observed is via the H + O 2 = OH + O reaction.

Hexamethyldisiloxane↗

Diagnosing ICF gamma-ray physics

Gamma rays produced in an ICF environment open up a host of physics opportunities we are just beginning to explore. A branch of the DT fusion reaction, with a branching ratio on the order of 2e-5 {gamma}/n, produces 16.7 MeV {gamma}-rays. These {gamma}-rays provide a direct measure of fusion reaction rate (unlike x-rays) without being compromised by Doppler spreading (unlike neutrons). Reaction-rate history measurements, such as nuclear bang time and burn width, are fundamental quantities that will be used to optimize ignition on the National Ignition Facility (NIF). Gas Cherenkov Detectors (GCD) that convert fusion {gamma}-rays to UV/visible Cherenkov photons for collection by fast optical recording systems established their usefulness in illuminating ICF physics in several experimental campaigns at OMEGA. Demonstrated absolute timing calibrations allow bang time measurements with accuracy better than 30 ps. System impulse response better than 95 ps fwhm have been made possible by the combination of low temporal dispersion GCDs, ultra-fast microchannel-plate photomultiplier tubes (PMT), and high-bandwidth Mach Zehnder fiber optic data links and digitizers, resulting in burn width measurement accuracy better than 10ps. Inherent variable energy-thresholding capability allows use of GCDs as {gamma}-ray spectrometers to explore other interesting nuclear processes. Recent measurements of the 4.44 MeV {sup 12}C(n,n{prime}) {gamma}-rays produced as 14.1 MeV DT fusion neutrons pass through plastic capsules is paving the way for a new CH ablator areal density measurement. Insertion of various neutron target materials near target chamber center (TCC) producing secondary, neutron-induced {gamma}y-rays are being used to study other nuclear interactions and as in-situ sources to calibrate detector response and DT branching ratio. NIF Gamma Reaction History (GRH) diagnostics, based on the GCD concept, are now being developed based on optimization of sensitivity, bandwidth, dynamic range, cost, and NIF-specific logistics, requirements and extreme radiation environment. Implementation will occur in two phases: (1) four PMT-based channels mounted to the outside of the target chamber at {approx}6m from TCC (GRH-6m) for the 3e13-3e16 DT neutron yield range expected during the early ignition-tuning campaigns; and (2) several channels located just inside the target bay shield wall at 15 m from TCC (GRH-15m) with optical paths leading through the cement shield wall to well-shielded streak cameras and PMTs for the 1e16-1e20 yield range expected during the DT ignition campaign. Multiple channels at each phase will allow for increased redundancy, reliability, accuracy and flexibility. This suite of diagnostics will make possible exploration of interesting {gamma}-ray physics well beyond the ignition campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First measurement of time evolution of electron temperature profiles with Nd:YAG Thomson scattering system on Heliotron J

A Nd:YAG Thomson scattering system has been developed for Heliotron J. The system consists of two 550 mJ 50 Hz lasers, large collection optics, and 25 radial channel (∼1 cm spatial resolution) interference polychromators. This measurement system achieves a S/N ratio of ∼50 for low-density plasma (n{sub e} ∼ 0.5 × 10{sup 19} m{sup −3}). A time evolution of electron temperature profiles was measured with this system for a high-intensity gas-puff (HIGP) fueling neutral-beam-injection plasma. The peripheral temperature of the higher-density phase after HIGP recovers to the low-density pre-HIGP level, suggesting that improving particle transport in the HIGP plasma may be possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SISTec: Mathematical Calibration of Large Clearance Monitors - 18265

One major path for clearance of large amount of waste arising from the decommission of nuclear power plants is based on measurement with large clearance monitors (also known as free release measurement facilities). These devices utilize multi-detector plastic scintillator arrays (large clearance monitors can consist of up to 24 plastic scintillators) to offer both, extremely low minimum detectable activities (MDA) and short measurement times for waste packages weighing up to one metric ton. However, a major problem with these devices is to obtain nuclide specific efficiencies, especially for geometrically complex large waste packages. Normal procedure for estimating the efficiency is to device dummy waste packages and attach point sources with well-known activities to unfavourable positions in these packages. In accordance with this procedure, calibration factors can be derived in a radiological conservative way. Devising such test dummies is not always possible and the procedure is prone to generating large measurement uncertainties. In this publication, we propose a new method to derive calibration factors by means of the Los Alamos National Laboratory (LANL) simulation tool Monte Carlo N-Particle (MCNP) and a statistical-phenomenological model for the detector characterization. In a multi-step approach, first the detector response for a distribution of activity in a waste package is calculated and subsequently the detectors are mathematically characterized. Applying state of the art statistical and optimizing procedures, parameters for the detector response are derived in a self-consistent way. This also allows to rigorously propagate the uncertainties to the final calculated calibration factors according to the Guide to the Expression of Uncertainty in Measurement (GUM supplement 1). To validate the derived parameters for the detector characterization a minimally invasive experimental setup was devised and installed into the large clearance monitor. It consisted of an aluminum swivel arm which could position point sources to the relevant coordinates. The so collected measurement data not only allowed to investigate the precision of the calculated calibration factors, but also to probe the location of concentrated activity sources in the waste package. Furthermore, data on measurements with dummy waste packages were collected to test the reproducibility of well-known calibration factors. We present the software tool SIStec, which will provide an intuitive user-interface to generate and simulate waste package models and execute the above-mentioned method. Using SIStec, different scenarios for the distribution of activity in the waste package can be probed. This will also allow to optimize the clearance process on various levels. For example, measurement time for pre-measurements can be reduced in exchange for unfavourable calibration factors, which would still allow to meet the regulator limits for clearance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of 16 measures of mental workload using a simulated flight task emphasizing mediational activity

As aircraft and other systems become more automated, a shift is occurring in human operator participation in these systems. This shift is away from manual control and toward activities that tap the higher mental functioning of human operators. Therefore, an experiment was performed in a moving-base flight simulator to assess mediational (cognitive) workload measurement. Specifically, 16 workload estimation techniques were evaluated as to their sensitivity and intrusion in a flight task emphasizing mediational behavior. Task loading, using navigation problems presented on a display, was treated as an independent variable, and workload-measure values were treated as dependent variables. Results indicate that two mediational task measures, two rating scale measures, time estimation, and two eye behavior measures were reliably sensitive to mediational loading. The time estimation measure did, however, intrude on mediational task performance. Several of the remaining measures were completely insensitive to mediational load.

Wierwille, W. W.↗

Measuring time-dependent diffusion in polymer matrix composites

Moisture plays a significant role in influencing the mechanical behavior and long-term durability of polymer matrix composites (PMC’s). The common methods used to determine the moisture diffusion coefficients of PMCs are based on the solution of Fickian diffusion in the one-dimensional domain. Fick’s Law assumes that equilibrium between the material surface and the external vapor is established instantaneously. A time dependent boundary condition has been shown to improve correlation with some bulk diffusion measurements, but has not been validated experimentally. The surface moisture content in a Toray 800S/3900-2B toughened quasi-isotropic laminate system, [0/±60]s, was analyzed experimentally using Nuclear Reaction Analysis (NRA). It was found that the surface moisture content showed a rapid increase to an intermediate concentration C0, followed by a slow linear increase to the saturation level.

composites↗

Reflection-Absorption Infrared Spectroscopy of Thin Films Using an External Cavity Quantum Cascade Laser

We present experimental demonstrations using a broadly tunable external cavity quantum cascade laser (ECQCL) to perform Reflection-Absorption InfraRed Spectroscopy (RAIRS) of thin layers and residues on surfaces. The ECQCL compliance voltage was used to measure fluctuations in the ECQCL output power and improve the performance of the RAIRS measurements. Absorption spectra from self-assembled monolayers of a fluorinated alkane thiol and a thiol carboxylic acid were measured and compared with FTIR measurements. RAIRS spectra of the explosive compounds PETN, RDX, and tetryl deposited on gold substrates were also measured. Rapid measurement times and low noise were demonstrated, with < 1E-3 absorbance noise for a 10 second measurement time.

Infrared Spectroscopy↗