Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEST METHODS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Enabling Evaluation of In-Situ Regolith-Based Construction Materials with Modified Methods for Testing Compressive Strength of Non-Cement Mortar Specimens Using Simulants & Analog Site Soils

Objectives for Phase II of NASA’s Artemis Program include establishment of lunar surface infrastructure to support a sustainable, long-term human presence on the Moon. Terrestrially, awareness of climate impacts from cement and concrete production has led to renewed interest in traditional building materials using earthen and pozzolanic binders with locally sourced aggregates [1, 2, 3]. In remote, austere,and resource-constrained environments, use of site-sourced materials is often an economic necessity in addition to being valuable for local autonomy and self-sufficiency. This study evaluates modifications to ASTM cement mortar testing methods, incorporating details from European standards for earthen plasters and lime-based mortars. Development of consistent, simplified methods for evaluating in-situ materials will be essential not only for meeting future climate goals and sustainable construction needs, but also for conducting autonomous robotic manipulation and evaluation of regolith construction materials.

ISRU↗

Error response test system and method using test mask variable

An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

Gender, Thomas K.↗

System Voltage Potential-Induced Degradation Mechanisms in PV Modules and Methods for Test: Preprint

Over the past decade, degradation and power loss have been observed in PV modules resulting from the stress exerted by system voltage bias. This is due in part to qualification tests and standards that do not adequately evaluate for the durability of modules to the long-term effects of high voltage bias experienced in fielded arrays. High voltage can lead to module degradation by multiplemechanisms. The extent of the voltage bias degradation is linked to the leakage current or coulombs passed from the silicon active layer through the encapsulant and glass to the grounded module frame, which can be experimentally determined; however, competing processes make the effect non-linear and history-dependent. Appropriate testing methods and stress levels are described that demonstratemodule durability to system voltage potential-induced degradation (PID) mechanisms. This information, along with outdoor testing that is in progress, is used to estimate the acceleration factors needed to evaluate the durability of modules to system voltage stress. Na-rich precipitates are observed on the cell surface after stressing the module to induce PID in damp heat with negative biasapplied to the active layer.

14 SOLAR ENERGY↗

High temperature stress-strain analysis

The objectives of the high-temperature structures program are threefold: to assist in the development of analytical tools needed to improve design analyses and procedures for the efficient and accurate prediction of the nonlinear structural response of hot-section components; to aid in the calibration, validation, and evaluation of the analytical tools by comparing predictions with experimental data; and to evaluate existing as well as advanced temperature and strain measurement instrumentation. As the analytical tools, test methods, tests, instrumentations, as well as data acquisition, management, and analysis methods are developed and evaluated, a proven, integrated analysis and experiment method will result in a more accurate prediction of the cyclic life of hot section components.

Thompson, Robert L.↗

Estimation of Aircraft Unsteady Aerodynamic Parameters from Dynamic Wind Tunnel Testing

Improved aerodynamic mathematical models, for use in aircraft simulation or flight control design, are required when representing nonlinear unsteady aerodynamics. A key limitation of conventional aerodynamic models is the inability to map frequency and amplitude dependent data into the equations of motion directly. In an effort to obtain a more general formulation of the aerodynamic model, researchers have been led to a parallel requirement for more general testing methods. Testing for a more comprehensive model can lead to a very time consuming number of tests especially if traditional single frequency harmonic testing is attempted. This paper presents an alternative to traditional single frequency forced-oscillation testing by utilizing Schroeder sweeps to efficiently obtain the frequency response of the unsteady aerodynamic model. Schroeder inputs provide signals with a flat power spectrum over a specified frequency band. For comparison, experimental results using the traditional single-frequency inputs are also considered. A method for data analysis to determine an adequate unsteady aerodynamic model is presented. Discussion of associated issues that arise during this type of analysis and comparison of results using traditional single frequency analysis are provided.

Murphy, Patrick C.↗

SU-D-210-07: The Dependence On Acoustic Velocity of Medium On the Needle Template and Electronic Grid Alignment in Ultrasound QA for Prostate Brachytherapy

Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work, two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

Poster - 09: A MATLAB-based Program for Automated Quality Assurance of a Prostate Brachytherapy Ultrasound System

Purpose: A robust Quality Assurance (QA) program is essential for prostate brachytherapy ultrasound systems due to the importance of imaging accuracy during treatment and planning. Task Group 128 of the American Association of Physicists in Medicine has recommended a set of QA tests covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, and template/electronic grid alignment. Making manual measurements on the ultrasound system can be slow and inaccurate, so a MATLAB program was developed for automation of the described tests. Methods: Test images were acquired using a BK Medical Flex Focus 400 ultrasound scanner and 8848 transducer with the CIRS Brachytherapy QA Phantom – Model 045A. For each test, the program automatically segments the inputted image(s), makes the appropriate measurements, and indicates if the test passed or failed. The program was tested by analyzing two sets of images, where the measurements from the first set were used as baseline values. Results: The program successfully analyzed the images for each test and determined if any action limits were exceeded. All tests passed – the measurements made by the program were consistent and met the requirements outlined by Task Group 128. Conclusions: The MATLAB program we have developed can be used for automated QA of an ultrasound system for prostate brachytherapy. The GUI provides a user-friendly way to analyze images without the need for any manual measurement, potentially removing intra- and inter-user variability for more consistent results.

60 APPLIED LIFE SCIENCES↗

DOE Solid-State Lighting CALiPER Program - Summary of Results: Round 7 of Product Testing

Round 7 of testing for the DOE Commercially Available LED Product Evaluation and Reporting (CALiPER) Program was conducted from September 2008 to January 2009. In this round, 29 products, representing a range of product types and technologies, were tested with both spectroradiometry and goniophotometry using absolute photometry, following the IESNA LM79-08 testing method. Testing also included measurements of surface temperatures (taken at the hottest accessible spots on the luminaire).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DOE Solid-State Lighting CALiPER Program Summary of Results: Round 9 of Product Testing

Round 9 of testing for the Department of Energy (DOE) Commercially Available LED Product Evaluation and Reporting (CALiPER) Program was conducted from June 2009 to September 2009. In this round, 30 products, representing a range of product types and technologies, were tested with both spectroradiometry and goniophotometry using absolute photometry. All solid-state lighting (SSL) products were tested following the IESNA LM-79-08 testing method. Testing also included measurements of surface temperatures (taken at the hottest accessible spots on the luminaire).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CALiPER Summary of Results: Round 10 of Product Testing

Round 10 of CALiPER testing was conducted from October 2009 to February 2010. In this round, 28 products, representing a range of product types and technologies, were tested with both spectroradiometry and goniophotometry using absolute photometry. All SSL products were tested following the IESNA LM-79-08 testing method. Testing also included measurements of surface temperatures (taken at the hottest accessible spots on the luminaire).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RF quantity gauging system

The modifications, calibration, and tests of the RF liquid mass gaging system, Benedix Type X1625027, are given. Also given are test methods, test results, and optimum performance of the system.

Source record↗

A fundamental approach to the sticking of insect residues to aircraft wings

The sticking of insect residues to aircraft wings is investigated. The major topics of this review are: Experimentally tested methods, testing techniques, the effect of surface roughness height on aerodynamic drag, materials tested and, the adhesive properties of insect body fluids are reviewed.

Eiss, N. S., Jr.↗

Cryogenic surface distortion and hysteresis of a 50 cm diameter fused silica mirror cooled to 77 K

A 50 cm diameter, lightweight, Amersil TO8E, fused-natural-quartz mirror with a single arch cross section was tested at the NASA/Ames Research Center Cryogenic Optics Test Facility to measure cryogenic distortion and hysteresis. The mirror was cooled to 77 K in four serial tests and the mirror figure was measured with a phase-measuring interferometer. On the basis of the repeatability of room temperature and cryogenic optical measurements, it was determined that the Single Arch Mirror had no measurable hysteresis and displayed repeatable cryogenic distortion. The Cryogenic Optics Test Facility, optical and thermal test methods, test results, and measurement accuracy are described.

Young, Jeffrey A.↗

JANNAF 25Th Airbreathing Propulsion Subcommittee, 37Th Combustion Subcommittee and 1St Modeling and Simulation Subcommittee Joint Meeting

Contents include the following: 1. Hyper-X program: Propulsion development and verification. 2. GTX program: Airbreathing launch vehicles. 3. Hypersonic technology development: Technology program overviews. Ramjet/scramjet research. 4. Hypersonic test methods: Test medium effects. 5. Advanced propulsion: RBCC engine design and performance assessments. Advanced and combined cycle engine technology.

Fry, Ronald S.↗

Measuring Core/Facesheet Bond Toughness in Honeycomb Sandwich Structures

This study examines two test methods to evaluate the peel toughness of the skin to core debond of sandwich panels. The methods tested were the climbing drum (CD) peel test and the double cantilever beam (DCB) test. While the CD peel test is only intended for qualitative measurements, it is shown in this study that qualitative measurements can be performed and compare well with DCB test data. It is also shown that artificially stiffening the facesheets of a DCB specimen can cause the test to behave more like a flatwise tensile test than a peel test.

Nettles, A. T.↗