Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEMPERATURE.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A method of computing the transient temperature of thick walls from arbitrary variation of adiabatic-wall temperature and heat-transfer coefficient

A method of calculating the temperature of thick walls has been developed in which the time series and the response to a unit triangle variation of surface temperature concepts are used, together with essentially standard formulas for transient temperature and heat flow into thick walls. The method can be used without knowledge of the mathematical tools of its development. The method is particularly suitable for determining the wall temperature in one-dimensional thermal problems in aeronautics where there is a continuous variation of the heat-transfer coefficient and adiabatic-wall temperature. The method also offers a convenient means for solving the inverse problem of determining the heat-flow history when temperature history is known.

Hill, P R↗

Surface temperatures in the polar regions from Nimbus 7 temperature humidity infrared radiometer

Monthly surface temperatures in the Arctic and Antarctic regions have been derived from the 11.5 micrometer thermal infrared channel of the Nimbus 7 temperature humidity infrared radiometer (THIR) for a whole year in 1979 and for a winter and a summer month from 1980 through 1985. The data set shows interannual variability and provides spatial details that allow identification of temperature patterns over sea ice and ice sheet surfaces. For example, the coldest spot in the southern hemisphere is observed to be consistently in the Antarctic plateau in the southern hemisphere, while that in the northern hemisphere is usually located in Greenland, or one of three other general areas: Siberia, the central Arctic, or the Canadian Archipelago. Also, in the southern hemisphere, the amplitude of the seasonal fluctuation of ice sheet temperatures is about 3 times that of sea ice, while in the northern hemisphere, the corresponding fluctuations for the two surfaces are about the same. The main sources of error in the retrieval are cloud and other atmospheric effects. These were minimized by first choosing the highest radiance value from the set of measurements during the day taken within a 30 km by 30 km grid of each daily map. Then the difference of daily maps was taken and where the difference is greater than a certain threshold (which in this case is 12 C), the data element is deleted. Overall, the monthly maps derived from the resulting daily maps are spatially and temporally consistent, are coherent with the topograph y of the Antarctic continent and the location of the sea ice edge, and are in qualitative agreement with climatological data. Quantitatively, THIR data are in good agreement with Antarctic ice sheet surface air temperature station data with a correlation coefficient of 0.997 and a standard deviation of 2.0 C. The absolute values are not as good over the sea ice edges, but a comparison with Russian 2-m drift station temperatures shows very high correlation (with correlation coefficient at 0.998) and a standard deviation of 1.1 C. Overall, the rms error is estimated to be from 1 to 2 C, depending on the surface, while the average bias when compared with in situ data is less than 2 C.

Comiso, Josefino C.↗

Estimating the urban bias of surface shelter temperatures using upper-air and satellite data. Part 1: Development of models predicting surface shelter temperatures

Multiple regression techniques were used to predict surface shelter temperatures based on the time period 1986-89 using upper-air data from the European Centre for Medium-Range Weather Forecasts (ECMWF) to represent the background climate and site-specific data to represent the local landscape. Global monthly mean temperature models were developed using data from over 5000 stations available in the Global Historical Climate Network (GHCN). Monthly maximum, mean, and minimum temperature models for the United States were also developed using data from over 1000 stations available in the U.S. Cooperative (COOP) Network and comparative monthly mean temperature models were developed using over 1150 U.S. stations in the GHCN. Three-, six-, and full-variable models were developed for comparative purposes. Inferences about the variables selected for the various models were easier for the GHCN models, which displayed month-to-month consistency in which variables were selected, than for the COOP models, which were assigned a different list of variables for nearly every month. These and other results suggest that global calibration is preferred because data from the global spectrum of physical processes that control surface temperatures are incorporated in a global model. All of the models that were developed in this study validated relatively well, especially the global models. Recalibration of the models with validation data resulted in only slightly poorer regression statistics, indicating that the calibration list of variables was valid. Predictions using data from the validation dataset in the calibrated equation were better for the GHCN models, and the globally calibrated GHCN models generally provided better U.S. predictions than the U.S.-calibrated COOP models. Overall, the GHCN and COOP models explained approximately 64%-95% of the total variance of surface shelter temperatures, depending on the month and the number of model variables. In addition, root-mean-square errors (rmse's) were over 3 C for GHCN models and over 2 C for COOP models for winter months, and near 2 C for GHCN models and near 1.5 C for COOP models for summer months.

Epperson, David L.↗

Effect of Temperature Cycling and Exposure to Extreme Temperatures on Reliability of Solid Tantalum Capacitors

In this work, results of multiple temperature cycling (TC) (up to 1,000 cycles) of different types of solid tantalum capacitors are analyzed and reported. Deformation of chip tantalum during temperature variations simulating reflow soldering conditions was measured to evaluate the possibility of the pop-corning effect in the parts. To simulate the effect of short-time exposures to solder reflow temperatures on the reliability of tantalum capacitors, several part types were subjected to multiple cycles (up to 100) between room temperature and 240 C with periodical measurements of electrical characteristics of the parts. Mechanisms of degradation caused by temperature cycling and exposure to high temperatures, and the requirements of MIL-PRF-55365 for assessment of the resistance of the parts to soldering heat are discussed.

Teverovsky, Alexander↗

Raman Channel Temperature Measurement of SiC MESFET as a Function of Ambient Temperature and DC Power

Raman spectroscopy is used to measure the junction temperature of a Cree SiC MESFET as a function of the ambient temperature and DC power. The carrier temperature, which is approximately equal to the ambient temperature, is varied from 25 C to 450 C, and the transistor is biased with VDS=10V and IDS of 50 mA and 100 mA. It is shown that the junction temperature is approximately 52 and 100 C higher than the ambient temperature for the DC power of 500 and 1000 mW, respectively.

Ponchak, George E.↗

Temperature Dependence of Thin Film Spiral Inductors on Alumina Over a Temperature Range of 25 to 475 C

In this paper, we present an analysis of inductors on an Alumina substrate over the temperature range of 25 to 475 C. Five sets of inductors, each set consisting of a 1.5, 2.5, 3.5, and a 4.5 turn inductor with different line width and spacing, were measured on a high temperature probe station from 10 MHz to 30 GHz. From these measured characteristics, it is shown that the inductance is nearly independent of temperature for low frequencies compared to the self resonant frequency, the parasitic capacitances are independent of temperature, and the resistance varies nearly linearly with temperature. These characteristics result in the self resonant frequency decreasing by only a few percent as the temperature is increased from 25 to 475 C, but the maximum quality factor decreases by a factor of 2 to 3. These observations based on measured data are confirmed through 2D simulations using Sonnet software.

Ponchak, George E.↗

On the Trend of the Annual Mean, Maximum, and Minimum Temperature and the Diurnal Temperature Range in the Armagh Observatory, Northern Ireland, Dataset, 1844 -2012

Examined are the annual averages, 10-year moving averages, decadal averages, and sunspot cycle (SC) length averages of the mean, maximum, and minimum surface air temperatures and the diurnal temperature range (DTR) for the Armagh Observatory, Northern Ireland, during the interval 1844-2012. Strong upward trends are apparent in the Armagh surface-air temperatures (ASAT), while a strong downward trend is apparent in the DTR, especially when the ASAT data are averaged by decade or over individual SC lengths. The long-term decrease in the decadaland SC-averaged annual DTR occurs because the annual minimum temperatures have risen more quickly than the annual maximum temperatures. Estimates are given for the Armagh annual mean, maximum, and minimum temperatures and the DTR for the current decade (2010-2019) and SC24.

Wilson, Robert M.↗

Apparatus and method for maintaining an article at a temperature that is less than the temperature of the ambient air

An apparatus for maintaining the temperature of an article at a temperature that is below the ambient air temperature includes an enclosure having an outer wall that defines an interior chamber for holding a volume of sealed air. An insert is disposed inside of the chamber and has a body that is made of a porous graphite foam material. A vacuum pump penetrates the outer wall and fluidly connects the sealed air in the interior chamber with the ambient air outside of the enclosure. The temperatures of the insert and article is maintained at temperatures that are below the ambient air temperature when a volume of a liquid is wicked into the pores of the porous insert and the vacuum pump is activated to reduce the pressure of a volume of sealed air within the interior chamber to a pressure that is below the vapor pressure of the liquid.

42 ENGINEERING↗

Crystallization Temperature of Aqueous Lithium Bromide Solutions at Low Evaporation Temperature

Water- aqueous Lithium Bromide (LiBr) solutions have shown superior performance as working fluid pairs for absorption refrigeration cycles. Most of the available literature (e.g. ASHRAE Handbook of Fundamentals, etc.) provide crystallization behavior down to only 10 C. The typical evaporating temperature for an absorption chiller system is usually lower than 10 C. Hence, it is essential to have an accurate prediction of the crystallization temperature in this range in order to avoid crystallization during the design phase. We have therefore conducted a systematic study to explore the crystallization temperatures of LiBr/Water solutions that fall below an evaporating temperature of 10 C. Our preliminary studies revealed that the rate of cooling of the sample solution influences the crystallization temperature; therefore we have performed a quasi steady test where the sample was cooled gradually by reducing the sample temperature in small steps. Results from this study are reported in this paper and can be used to extend the data available in open literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Temperature Dependence of Ar{sub n}{sup +} Cluster Backscattering from Polymer Surfaces: a New Method to Determine the Surface Glass Transition Temperature

In this work, time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to study the intensity variations of the backscattered Ar{sub n}{sup +} clusters as a function of temperature for several amorphous polymer surfaces (polyolefins, polystyrene, and polymethyl methacrylate). For all these investigated polymers, our results show a transition of the ratio Ar{sub 2}{sup +}/(Ar{sub 2}{sup +} + Ar{sub 3}{sup +}) when the temperature is scanned from –120 °C to +125 °C (the exact limits depend on the studied polymer). This transition generally spans over a few tens of degrees and the temperature of the inflection point of each curve is always lower than the bulk glass transition temperature (T{sub g}) reported for the considered polymer. Due to the surface sensitivity of the cluster backscattering process (several nanometers), the presented analysis could provide a new method to specifically evaluate a surface transition temperature of polymers, with the same lateral resolution as the gas cluster beam. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of rf power on electron density and temperature, neutral temperature, and T{sub e} fluctuations in an inductively coupled plasma

Atomic clocks that fly on global-navigation satellites such as global positioning system (GPS) and Galileo employ light from low-temperature, inductively coupled plasmas (ICPs) for atomic signal generation and detection (i.e., alkali/noble-gas rf-discharge lamps). In this application, the performance of the atomic clock and the capabilities of the navigation system depend sensitively on the stability of the ICP's optical emission. In order to better understand the mechanisms that might lead to instability in these rf-discharge lamps, and hence the satellite atomic clocks, we studied the optical emission from a Rb/Xe ICP as a function of the rf power driving the plasma. Surprisingly, we found that the electron density in the plasma was essentially independent of increases in rf power above its nominal value (i.e., 'rf-power gain') and that the electron temperature was only a slowly varying function of rf-power gain. The primary effect of rf power was to increase the temperature of the neutrals in the plasma, which was manifested by an increase in Rb vapor density. Interestingly, we also found evidence for electron temperature fluctuations (i.e., fluctuations in the plasma's high-energy electron content). The variance of these fluctuations scaled inversely with the plasma's mean electron temperature and was consistent with a simple model that assumed that the total electron density in the discharge was independent of rf power. Taken as a whole, our results indicate that the electrons in alkali/noble-gas ICPs are little affected by slight changes in rf power and that the primary effect of such changes is to heat the plasma's neutral species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of electron temperature of imploded capsules at the National Ignition Facility

The electron and ion temperatures of the imploded core plasma are two of the most important metrics of inertial confinement fusion experiments. We have developed a technique for inferring electron temperatures from the contrast of x-ray images observed through a group of x-ray filters. Generally, the plasma electron temperature exhibits spatial and temporal variations, so time-averaged and time-resolved measurements are expected to yield somewhat different results. By analyzing the intensity of images observed with both a time-integrated detector (imaging plates) and a time-resolved detector (gated micro-channel plate), we found the electron temperature observed from x-ray images to be systematically higher than the ion temperature inferred from fusion neutron spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probes for investigating the effect of magnetic field, field orientation, temperature and strain on the critical current density of anisotropic high-temperature superconducting tapes in a split-pair 15 T horizontal magnet

We present the designs of probes for making critical current density (J{sub c}) measurements on anisotropic high-temperature superconducting tapes as a function of field, field orientation, temperature and strain in our 40 mm bore, split-pair 15 T horizontal magnet. Emphasis is placed on the design of three components: the vapour-cooled current leads, the variable temperature enclosure, and the springboard-shaped bending beam sample holder. The vapour-cooled brass critical-current leads used superconducting tapes and in operation ran hot with a duty cycle (D) of ∼0.2. This work provides formulae for optimising cryogenic consumption and calculating cryogenic boil-off, associated with current leads used to make J{sub c} measurements, made by uniformly ramping the current up to a maximum current (I{sub max}) and then reducing the current very quickly to zero. They include consideration of the effects of duty cycle, static helium boil-off from the magnet and Dewar (b{sup ′}), and the maximum safe temperature for the critical-current leads (T{sub max}). Our optimized critical-current leads have a boil-off that is about 30% less than leads optimized for magnet operation at the same maximum current. Numerical calculations show that the optimum cross-sectional area (A) for each current lead can be parameterized by LI{sub max}/A=[1.46D{sup −0.18}L{sup 0.4}(T{sub max}−300){sup 0.25D{sup −{sup 0{sup .{sup 0{sup 9}}}}}}+750(b{sup ′}/I{sub max})D{sup 10{sup −{sup 3I{sub m}{sub a}{sub x}−2.87b{sup ′}}}}]× 10{sup 6}A m{sup −1} where L is the current lead's length and the current lead is operated in liquid helium. An optimum A of 132 mm{sup 2} is obtained when I{sub max} = 1000 A, T{sub max} = 400 K, D = 0.2, b{sup ′} = 0.3 l h{sup −1} and L = 1.0 m. The optimized helium consumption was found to be 0.7 l h{sup −1}. When the static boil-off is small, optimized leads have a boil-off that can be roughly parameterized by: b/I{sub max } ≈ (1.35 × 10{sup −3})D{sup 0.41} l h{sup ‑1} A{sup −1}. A split-current-lead design is employed to minimize the rotation of the probes during the high current measurements in our high-field horizontal magnet. The variable-temperature system is based on the use of an inverted insulating cup that operates above 4.2 K in liquid helium and above 77.4 K in liquid nitrogen, with a stability of ±80 mK to ±150 mK. Uniaxial strains of −1.4% to 1.0% can be applied to the sample, with a total uncertainty of better than ±0.02%, using a modified bending beam apparatus which includes a copper beryllium springboard-shaped sample holder.

43 PARTICLE ACCELERATORS↗

Absence of low temperature phase transitions and enhancement of ferroelectric transition temperature in highly strained BaTiO{sub 3} epitaxial films grown on MgO Substrates

Recently, a large enhancement in the ferroelectric transition temperature of several oxides is reported by growing the respective thin films on appropriate substrates. This phenomenon is correlated with high residual strain in thin films often leading to large increase in the tetragonality of their crystal structure. However, such an enhancement of transition temperature is usually limited to very thin films of ∼10 nm thickness. Here, we report growth of fully strained epitaxial thin films of BaTiO{sub 3} of 400 nm thickness, which are coherently grown on MgO substrates by pulsed laser deposition technique. Conventional high resolution x-ray diffraction and also the reciprocal space map measurements confirm that the film is fully strained with in-plane tensile strain of 5.5% that dramatically increases the tetragonality to 1.05. Raman measurements reveal that the tetragonal to cubic structural phase transition is observed at 583 K, which results in an enhancement of ∼200 K. Furthermore, temperature dependent Raman studies on these films corroborate absence of all the low temperature phase transitions. Numerical calculations based on thermodynamical model predict a value of the transition temperature that is greater than 1500 °C. Our experimental results are therefore in clear deviation from the existing strain dependent phase diagrams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature dependent striction effect in a single crystalline Nd 2 Fe 14 B revealed using a novel high temperature resistivity measurement technique

In this work, we studied the temperature dependence of resistivity in a single crystalline Nd 2 Fe 14 B using a newly developed high temperature probe. This novel probe employs mechanical pin connectors instead of conducting glue/paste. From warming and cooling curves, the Curie temperature was consistently measured around T c = 580 K. In addition, anomalous discrete jumps were found only in cooling curves between 400 and 500 K, but not shown in warming curves. More interestingly, when the jumps occurred during cooling, the resistivity was increased. This phenomenon could possibly be due to a temperature dependent striction effect induced by the re-orientation of magnetic domains well below the Curie temperature. Further microscopic study is needed to confirm this effect.

permanent magnet↗

Core temperature is regulated, although at a lower temperature, in rats exposed to hypergravic fields

1. In rats acclimated to 23 degrees C (RT rats) or 5 degrees C (CA rats), core temperature (Tc), tail temperature (Tt) and oxygen consumption (VO2) were measured during exposure to a hypergravic field. 2. Rats were exposed for 5.5 h to a 3 g field while ambient temperature (Ta) was varied. For the first 2 h, Ta was 25 degrees C; then Ta was raised to 34 degrees C for 1.5 h. During this period of warm exposure, Tc increased 4 degrees C in both RT and CA rats. Finally, Ta was returned to 25 degrees C for 2 h, and Tc decreased toward the levels measured prior to warm exposure. 3. In a second experiment at 3 g, RT and CA rats were exposed to cold (12 degrees C) after two hours at 25 degrees C. During the one hour cold exposure, Tc fell 1.5 degrees C in RT and 0.5 degree C in CA rats. After cold exposure, when ambient temperature was again 25 degrees C, Tc of RT and CA rats returned toward the levels measured prior to the thermal disturbance. 4. Rats appear to regulate their temperature, albeit at a lower level, in a 3 g field.

NASA Discipline Number 40-30↗

An Analysis of Spatio-Temporal Relationship between Satellite-Based Land Surface Temperature and Station-Based Near-Surface Air Temperature over Brazil

A better understanding of the relationship between land surface temperature (Ts) and near-surface air temperature (Ta) is crucial for improving the simulation accuracy of climate models, developing retrieval schemes for soil and vegetation moisture, and estimating large-scale Ta from satellite-based Ts observations. In this study, we investigated the relationship between multiple satellite-based Ts products, derived from the Atmospheric Infrared Sounder (AIRS) and the Moderate Resolution Imaging Spectroradiometer (MODIS) onboard Aqua satellite, and Ta from 204 meteorological stations over Brazil during 2003–2016. Monthly satellite-based Ts products used in this study include: (1) AIRS Version 6 with 1° spatial resolution, (2) AIRS Version 7 with 1° spatial resolution, (3) MODIS Collection 6 with 0.05° spatial resolution, and (4) MODIS Collection 6 with 1° spatial resolution re-sampled from (3) for a direct comparison with AIRS products. We found that satellite-based Ts is lower than Ta over the forest area, but higher than Ta over the non-forest area. Nevertheless, the correlation coefficients (R) between monthly Ta and four Ts products during 2003–2016 are greater than 0.8 over most stations. The long-term trend analysis shows a general warming trend in temperatures, particularly over the central and eastern parts of Brazil. The satellite products could also observe the increasing Ts over the deforestation region. Furthermore, we examined the temperature anomalies during three drought events in the dry season of 2005, 2010, and 2015. All products show similar spatio-temporal patterns, with positive temperature anomalies expanding in areal coverage and magnitude from the 2005 to 2015 event. The above results show that satellite-based Ts is sensitive in reflecting environmental changes such as deforestation and extreme climatic events, and can be used as an alternative to Ta for climatological studies. Moreover, the observed differences between Ts and Ta may inform how thermal assumptions can be improved in satellite-based retrievals of soil and vegetation moisture or evapotranspiration.

land surface temperature↗