Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEMPERATURE PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Energy relaxation dynamics in a nodal-line semimetal

Here we study the temperature relaxation dynamics of nodal-line semimetals after a sudden excitation in the presence of acoustic and optical phonon modes. We find that the nodal line constrains the electron momenta in scattering processes, and as a result, the temperature relaxation due to acoustic phonons is exponential as a function of time. However, depending on initial conditions, other functional forms are possible. In typical pump-probe experiments, the temperature relaxation is linear due to acoustic phonons with rates that vary as ~n 1/2 with density. The temperature relaxation due to optical phonons is also linear with rates ~n -1/2 or ~n .

36 MATERIALS SCIENCE↗

Evidence of atmospheric gravity wave perturbations of the Brunt-Vaisala frequency in the atmosphere

A series of high altitude, medium resolution, measurements of temperature, pressure and turbulence have been performed by the Air Force Geophysics Laboratory. These measurements were conducted using the VIZ Manufacturing Co. microsondes with attached micro-thermal probes measuring the temperature structure coefficient. A typical atmospheric temperature measurement is given. Several small temperature inversions are evident in the troposphere. The stratosphere is marked with numerous fluctuations in the temperature profile. Microsondes provide temperature and pressure measurements every 4 seconds up to a maximum altitude of 30 km (MSL). Since the average ascent rate is 5 m/s, the altitude interval between the measurement reports is 20 m. The potential temperature is calculated from the temperature and pressure. Spectral analysis of atmospheric Brunt-Vaisala frequencies reveal spectra similiar to the velocity spectra of Dewan et al. (1984), Daniels (1982), and Endlich and Singleton (1969). The Brunt-Vaisala spectra indicate the existence of separate, distinguishable wave modes.

Good, R. E.↗

Instrument for spatially resolved, temperature-dependent electrochemical impedance spectroscopy of thin films under locally controlled atmosphere

We demonstrate an instrument for spatially resolved measurements (mapping) of electrochemical impedance under various temperatures and gas environments. Automated measurements are controlled by a custom LabVIEW program, which manages probe motion, sample motion, temperature ramps, and potentiostat functions. Sample and probe positioning is provided by stepper motors. Dry or hydrated atmospheres (air or nitrogen) are available. The configurable heater reaches temperatures up to 500 °C, although the temperature at the sample surface is moderated by the gas flow rate. The local gas environment is controlled by directing flow toward the sample via a glass enclosure that surrounds the gold wire probe. Software and hardware selection and design are discussed. Reproducibility and accuracy are quantified on a Ba(Zr,Y)O 3-δ proton-conducting electrolyte thin film synthesized by pulsed laser deposition. The mapping feature of the instrument is demonstrated on a compositionally graded array of electrocatalytically active Ba(Co,Fe,Zr,Y)O 3-δ thin film microelectrodes. The resulting data indicate that this method proficiently maps property trends in these materials, thus demonstrating the reliability and usefulness of this method for investigating electrochemically active thin films.

47 OTHER INSTRUMENTATION↗

A Distributed Temperature Profiling System for Vertically and Laterally Dense Acquisition of Soil and Snow Temperature: Supporting Data

This dataset was used to assess the potential of a Distributed Temperature Profiling System developed and presented in the article named "A Distributed Temperature Profiling System for Vertically and Laterally Dense Acquisition of Soil and Snow Temperature" and submitted to Cryosphere. There are three comma-delimited data files (.csv). Each of them contains snow or soil temperature with times (UTC) in the first column and temperature at various vertical distance from the ground surface (positive means in air/snow) or below the ground surface (negative means in soil). The measurements were acquired every 15 minutes. Data collected at the East River, Colorado site with two probes: 1) measuring air/snow temperature from 1.1 m above the ground surface to the ground surface (with 5 or 10 cm spacing between sensors) and 2) measuring soil temperature from the ground surface to 0.7 m depth (with 5 or 10 cm spacing between sensors). Data collected at the Teller road (mile 27) site near Nome, Alaska with one probe: measuring soil temperature from 5 cm above the ground surface to 1.05 m depth (with 5 or 10 cm spacing between sensors). Additional metadata included in *.csv and *.pdf files. NGEE Arctic Project Summary: The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Hot-Wire Probe for Compressible Subsonic Flow

Probe measures velocity, density, and total temperature fluctuations. Three-wire probe used with each wire operating at different overheat ratio. Technique extendable into transonic and low supersonic flow regimes without difficulty except for those problems usually associated with lengthy calibration and possible wire breaking.

Stainback, P. C.↗

Height-resolved emission spectroscopy and high-speed imaging of the TiAl6V4 vapor plume under laser powder bed fusion conditions

Optical emission spectroscopy is increasingly used as an in situ monitoring technique during laser powder bed fusion (LPBF) because plume emission holds elemental information not found in other in situ sensing techniques. This work explores the shape, stability, and temperature of the emission plume above the melt pool of Ti6Al4 V undergoing laser scans under LPBF-like processing conditions, using high-speed video and height-resolved spectroscopy to study the details of plume dynamics. Optical emission spectroscopy is conducted in the 480 nm to 525 nm region, where Ti emission is strong, with 0.3 mm vertical resolution above the baseplate. The Boltzmann plot method is used to determine temperature at each probed elevation, which indicates that the hottest location of the plume is occasionally elevated 0.3 mm to 0.6 mm above the scanning surface. The results show that the plume shape, stability, temperature, and spectra are highly dependent on the processing conditions. We highlight some of the complexities of optical emission spectroscopy and discuss potential challenges for implementing optical emission spectroscopy across an entire build.

36 MATERIALS SCIENCE↗

Thermal neutron scattering measurements and modeling of yttrium-hydrides for high temperature moderator applications

In this work, thermal neutron scattering measurements of yttrium hydride from 5 to 1,200 K were conducted to determine the change in inelastic scattering as a function of temperature and to probe for anharmonic effects. Additionally, measurements on samples of YH x from x = 1.62 to 1.90 were done to determine the effects of varying hydrogen concentration on the inelastic spectra. Changes in temperature affected the inelastic spectra in unanticipated ways, indicating that there are anharmonic effects, whereas hydrogen concentration did not significantly affect the inelastic spectra. These measurements were compared against the ENDF/B-VIII.0 thermal scattering files of YH 2 , as well as new thermal scattering files created by using the stochastic temperature-dependent effective potential (s-TDEP). Both libraries were found to be in good agreement with the experimental data at lower temperatures. At higher temperatures, the s-TDEP method is better at predicting the experimentally observed softening of phonon modes in acoustic and optical regions.

36 MATERIALS SCIENCE↗

Electron and ion temperatures - A comparison of ground-based incoherent scatter and AE-C satellite measurements

The paper presents the results of comparisons of AE-C electron temperature of the ionosphere determined from the cylindrical electrostatic probe and the ion temperature of the ionosphere determined from the planar retarding potential analyzer with electron and ion temperatures determined from four incoherent scatter facilities: Arecibo, St. Santin, Millstone Hill, and Chatanika. Good agreement was obtained between the in situ and remote measurements of electron and ion temperatures. Longitudinal variations are found to be very important in the comparison of electron temperatures at some locations.

Benson, R. F.↗

2009 Goose Bay Experiment Ocean Measurements: Data - Part 1

During late February and early March 2009, a field experiment was performed using the NASA P3 over the Labrador Sea. During this experiment, expendable probes deployed from the aircraft acquired ocean mixed layer temperature, salinity and currents Probes were deployed during three flights of the four. Overall 7 AXBTs, 15 AXCTDs and 7 AXCPs were deployed with a success rate of nearly 70%. This is much lower than expected based on prior experience deploying from other aircraft. But given the difficulties associated with the Pneumatic Sonobuoy Launch Tube mechanism on the NASA P3, this rate likely can be improved significantly by using a different deployment mechanism. Additionally, two sets of collocated measurements of AXBTs, AXCPs and AXCTDs were made to verify the drop rates and measurements of the old AXBTs. While there were differences in the measurements, the old AXCTDs are performing well. The expendable data from the experiment are compared to the Argo profiles in the region to check for consistency. Comparisons indicate all the expendable probes acquired useful data and are well within the range of values measured by Argo floats.

Jacob, S. Daniel↗

New Approach for Thermal Protection System of a Probe During Entry

One of the biggest challenges for any thermal protection system (TPS) of a probe is to provide a sufficient barrier for heat generated during descent in order to keep the temperature inside of the probe low enough to support operational temperature of equipment. Typically, such a goal is achieved by having the ceramic tiles and blankets like on the Space Shuttle, silicon based ablators, or metallic systems to cover the probe external surface. This paper discusses the development of an innovative technique for TPS of the probe. It is proposed to use a novel TPS which comprises thermal management of the entry vehicle. It includes: a) absorption of the heat during heat pick load by a Phase Change Material (PCM), b) separation of the compartment which contains PCM from the rest of the space vehicle by a gap with a high thermal resistance, c) maintaining temperature of the internal wall of s/c cabin temperature by transfer heat from the internal wall to the "cold" side of the vehicle and to reject heat into the space during the flight and on a ground, d) utilization of an advanced heat pipe, so called Loop Heat Pipe to transfer heat from the cabin internal wall to the cold side of the s/c and to reject the heat into environment outside of the vehicle. A Loop Heat Pipe is capable of transferring heat against gravity

Yendler, Boris↗

Combining molecular beam epitaxy and low-energy electron microscopy with in situ magnetic susceptibility measurements within an integrated ultrahigh vacuum system

Quantum two-dimensional materials, including ultrathin superconducting films, are of great current research interest. These films are typically fabricated under ultra-high vacuum (UHV) conditions and are sensitive to the environment—prone to oxidation and contamination when exposed to the atmosphere. This hampers the study of their intrinsic properties by standard ex situ techniques. Here, we present a variable-temperature mutual inductance probe system integrated under UHV with molecular beam epitaxy (MBE) synthesis and low-energy electron microscopy, enabling nondestructive in situ characterization of superconducting thin films. The system employs a reflection-type configuration and reaches a low temperature (∼4 K) using a high-cooling-power, vibration-isolated cryocooler. In conclusion, we demonstrate the system performance by measuring the superconducting critical temperature in a copper-oxide thin film.

2D materials↗

Reactivity, Formation, and Solubility of Polyoxometalates Probed by Calorimetry

Room temperature calorimetry methods were developed to describe the energy landscapes of six polyoxometalates (POMs), Li–U 24 , Li–U 28 , K–U 28 , Li/K–U 60 , Mo 132 , and Mo 154 , in terms of three components: enthalpy of dissolution (ΔH diss ), enthalpy of formation of aqueous POMs (ΔH f,(aq) ), and enthalpy of formation of POM crystals (ΔH f,(c) ). ΔH diss is controlled by a combination of cation solvation enthalpy and the favorability of cation interactions with binding sites on the POM. In the case of the four uranyl peroxide POMs studied, clusters with hydroxide bridges have lower ΔH f,(aq) and are more stable than those containing only peroxide bridges. Here, in general for POMs, the combination of calorimetric results and synthetic observations suggest that spherical topologies may be more stable than wheel-like clusters, and ΔH f,(aq) can be accurately estimated using only ΔH f,(c) values owing to the dominance of the clusters in determining the energetics of POM crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal Neutron Scattering Evaluation of Yttrium Hydride (FY2020 Progress)

This paper details the thermal neutron scattering measurements of yttrium hydride for various hydrogen concentrations and temperatures that were conducted at the Spallation Neutron Source at Oak Ridge National Laboratory. Measurements at a temperature range of 5 to 1,200 K were conducted to determine the change in inelastic scattering as a function of temperature and to probe for any anharmonic effects known to exist in other metallic hydrides. Additionally, hydrogen concentrations of YH x that range from x = 1.62 to 1.90 were measured to determine the effects of varying hydrogen concentration on the inelastic neutron spectra. Changes in temperature affected the inelastic spectra in unanticipated ways, indicating that there are anharmonic effects, whereas hydrogen concentration does not significantly affect the inelastic spectra. These measurements were compared against the ENDF/B-VIII.0 thermal scattering files of hydrogen in YH 2 and yttrium in YH 2 , as well as a new thermal scattering file created by using the stochastic temperature-dependent effective potential (s-TDEP). Both libraries were found to be in good agreement with the experimental data at lower temperatures. At higher temperatures, the s-TDEP method is better at predicting the experimentally observed softening of phonon modes in acoustic and optical regions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An APFIM/AEM Study of Phase Decompositions in Fe-Ni Alloys at Low Temperatures

A combined atom probe field ion microscopy and analytical electron microscopy characterization has been performed on laboratory aged martensitic and austenitic specimens of FeNi and FeNiP alloys. These techniques revealed that the martensitic 24.1 and 28.6 at.% Ni alloys decomposed during aging for 1 year at 300 C to form face centered cubic precipitates of approx. 56 at.% Ni in a body centered cubic matrix containing approx. 20 at.% Ni. Some thin platelets were observed in the field ion micrographs of the austenitic Fe-42.9 at. % Ni alloy and the Fe-43.2 at.% Ni-0.44 at.% P alloy after aging at 400 and 350 C. Atom probe analysis revealed phosphorus clustering in the ternary alloy aged at 300 C.

Zhang, J.↗

Carbon-13 Labeling Used to Probe Cure and Degradation Reactions of High- Temperature Polymers

High-temperature, crosslinked polyimides are typically insoluble, intractible materials. Consequently, in these systems it has been difficult to follow high-temperature curing or long-term degradation reactions on a molecular level. Selective labeling of the polymers with carbon-13, coupled with solid nuclear magnetic resonance spectrometry (NMR), enables these reactions to be followed. We successfully employed this technique to provide insight into both curing and degradation reactions of PMR-15, a polymer matrix resin used extensively in aircraft engine applications.

Meador, Mary Ann B.↗

Hot-wire calibration in subsonic/transonic flow regimes

A different approach for calibrating hot-wires, which simplifies the calibration procedure and reduces the tunnel run-time by an order of magnitude was sought. In general, it is accepted that the directly measurable quantities in any flow are velocity, density, and total temperature. Very few facilities have the capability of varying the total temperature over an adequate range. However, if the overheat temperature parameter, a(sub w), is used to calibrate the hot-wire then the directly measurable quantity, voltage, will be a function of the flow variables and the overheat parameter i.e., E = f(u,p,a(sub w), T(sub w)) where a(sub w) will contain the needed total temperature information. In this report, various methods of evaluating sensitivities with different dependent and independent variables to calibrate a 3-Wire hot-wire probe using a constant temperature anemometer (CTA) in subsonic/transonic flow regimes is presented. The advantage of using a(sub w) as the independent variable instead of total temperature, t(sub o), or overheat temperature parameter, tau, is that while running a calibration test it is not necessary to know the recovery factor, the coefficients in a wire resistance to temperature relationship for a given probe. It was deduced that the method employing the relationship E = f (u,p,a(sub w)) should result in the most accurate calibration of hot wire probes. Any other method would require additional measurements. Also this method will allow calibration and determination of accurate temperature fluctuation information even in atmospheric wind tunnels where there is no ability to obtain any temperature sensitivity information at present. This technique greatly simplifies the calibration process for hot-wires, provides the required calibration information needed in obtaining temperature fluctuations, and reduces both the tunnel run-time and the test matrix required to calibrate hotwires. Some of the results using the above techniques are presented in an appendix.

Nagabushana, K. A.↗

Transcutaneous and End-Tidal CO 2 Measurements in Hypoxia and Hyperoxia

BACKGROUND: Transcutaneous measurement of carbon dioxide (CO 2 ) has been proposed for physiological monitoring of tactical jet aircrew because in some clinical settings it mirrors arterial CO 2 partial pressure (P a co 2 ). End-tidal monitoring in laboratory settings is known to give high-fidelity estimates of P a co 2 . METHODS: The correspondence between end-tidal (P ET co 2 ) and transcutaneous Pco 2 (tcPco 2 ) was examined in healthy volunteers under laboratory conditions of hyperoxia and hypoxia. Rest and exercise, skin heating and cooling, hyperventilation, and induced CO 2 retention were employed. RESULTS: Neither measure followed all known changes in P a co 2 and tcPco 2 changed when the skin temperature near the probe changed. Bland-Altman analysis showed significant nonzero slopes under most conditions. Regression analysis indicated that oxygen partial pressure (Po 2 ) in tissue measured as transcutaneous Po 2 (tcPo 2 ) is an important explanatory variable for tcPco 2 in addition to P ET co 2 , and that local skin temperature also has an effect. Additionally, absorption atelectasis from breathing 100% O 2 may cause P ET co 2 to deviate from P a co 2 . DISCUSSION: Even as a trend indicator for P a co 2 , tcPco 2 is not useful under conditions that resemble those in the highly dynamic tactical jet aircraft environment. P ET co 2 is also not a good indicator of CO 2 status in pilots who breathe nearly 100% O 2 . Shykoff BE, Lee LR, Gallo M, Griswold CA. Transcutaneous and end-tidal CO 2 measurements in hypoxia and hyperoxia . Aerosp Med Hum Perform. 2021; 92(11):864–872 .

Biophysics↗