Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEMPERATURE COEFFICIENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Interpretation of Fracture Initiation Points by In-Well Low-Frequency Distributed Acoustic Sensing in Horizontal Wells

Summary Low-frequency distributed acoustic sensing (LF-DAS) exploits the optical phase shift of Rayleigh backscatter in fiber-optic cables to obtain distributed measurements of changes in strain and temperature. Fiber-optic cables are often installed for multistage hydraulic fracture diagnostics in horizontal wells. LF-DAS in an untreated well provides far-field strain measurements, while offset wells are hydraulically fractured. Such a configuration is called crosswell LF-DAS sensing. Crosswell LF-DAS measurements have proved useful in diagnosing fracture hits, fracture azimuth, planarity, cluster efficiency, fracture propagation rates, and the dynamic distance to the fracture front. In contrast, in-well LF-DAS is conducted on the actively fractured well. Due to cool fracture fluid being injected at high injection rates, the strain component of the LF-DAS response is largely obscured by temperature changes. In permanent fiber-optic cable installations, distributed temperature sensing (DTS) is often conducted simultaneously with LF-DAS. An opportunity exists to decouple the temperature and strain components of LF-DAS sensors to observe strain changes on in-well LF-DAS. The LF-DAS response is modeled as linearly dependent on strain and temperature changes. Theoretical LF-DAS temperature and strain sensitivity coefficients are derived based on the changes to the index of refraction and length of the fiber. Using the DTS measurements, temperature changes are computed, smoothed, filtered, and compared to the LF-DAS response. Crossplots of the in-well LF-DAS measurements and temperature changes from DTS measurements far from the actively fractured region are used to validate the theoretical sensitivity coefficients. Uncertainty in the temperature component of the LF-DAS response is quantified. The difficulty in corresponding the different spatial and temporal resolutions of the DTS and LF-DAS measurements is overcome by comparing the responses over a moving temporal and spatial window. If the LF-DAS response at the center of the window agrees with the DTS response within uncertainty, the measurement is filtered out. After filtering, the remaining nonzero in-well LF-DAS measurements are due to changes in strain. The data are then visualized in waterfall plots. The results indicate that the theoretical and observed strain and temperature coefficients agree within 10%. After the temperature component of the in-well LF-DAS response is extracted, the remaining nonzero measurements are located primarily within the actively treated region. Locations with peaks in the strain response are interpreted to indicate fracture initiation points. These fracture initiation points are compared with in-well DTS and high-frequency DAS noise measurements across multiple stages to better understand fracture initiation along the horizontal well.

Engineering↗

Thermal Properties of the Very Low Thermal Conductivity Ternary Chalcogenide Cu 4 Bi 4 M 9 (M = S, Se)

Temperature-dependent thermal properties of phase-pure polycrystalline ternary chalcogenides Cu 4 Bi 4 S 9 and Cu 4 Bi 4 Se 9 are reported. The structure and bonding in these materials result in very low thermal conductivity values (<0.8 W m -1 K -1 at room temperature) for both materials. The lattice contribution, Debye temperatures, and Sommerfeld coefficient are obtained from low-temperature heat capacity data that also indicate very small electronic contributions to the heat capacity for these materials. This study aids in the identification of new nontoxic, earth-abundant resistive ternary chalcogenide materials with low thermal conductivity for potential thermal barrier coating and rewriteable storage applications.

36 MATERIALS SCIENCE↗

Automated power-following control for nuclear thermal propulsion startup and shutdown using MOOSE-based applications

This paper describes an investigation of various automated control strategies applied to a full-core multiphysics Griffin/Bison/RELAP-7 model of a prototypical nuclear thermal propulsion system. In all cases, control is achieved by actuating control drums based on the demanded power and predicted quantities from the numerical model. One key finding is that hybrid proportional integral derivative controllers – a novel type of controller that uses both power and reactivity predicted signals – can demonstrate a level of performance rivaling that of period-generated control. The former requires parameter tuning, while the latter mostly necessitates providing reactivity coefficients and temperature rates of change, which could be very challenging to accurately measure in real-time. In addition, decay heat plays an important role in determining cooling requirements during cooldown phases. A decay heat model, accounting for burn time and throttling, was derived, and is incorporated within the model to simulate the steady-state and shutdown phases and satisfyingly follow the power demand. However, temperature overshoots and non-constant specific impulse during throttling will necessitate further improvements.

33 ADVANCED PROPULSION SYSTEMS↗

Ultrafast and Highly Mobile Photocarriers in Monolayer WSe 2 Doped by α-RuCl 3

We report an experimental investigation of photocarrier dynamics in a heterostructure formed by a WSe 2 monolayer stacked on a multilayer α-RuCl 3 flake. The samples were fabricated using mechanical exfoliation and dry transfer techniques. Photoluminescence measurements showed that the excitonic photoluminescence of WSe 2 is quenched by more than 3 orders of magnitude upon contact with α-RuCl 3 . Transient absorption measurements revealed an ultrashort photocarrier lifetime of 0.5 ps in the heterostructure. Spatially resolved transient absorption microscopy measurements were employed to probe the transport properties of these photocarriers, resulting in a room-temperature diffusion coefficient of 370 cm 2 s –1 , which is higher than the exciton diffusion coefficients of most previously studied 2D semiconductors. Furthermore, these results suggest that α-RuCl 3 -doped WSe 2 could be utilized in high-speed optoelectronic devices.

36 MATERIALS SCIENCE↗

Theoretical study of the CO 2 –O 2 van der Waals complex: potential energy surface and applications

A four-dimensional-potential energy surface (4D-PES) of the atmospherically relevant carbon dioxide–oxygen molecule (CO 2 –O 2 ) van der Waals complex is mapped using the ab initio explicitly correlated coupled cluster method with single, double, and perturbative triple excitations (UCCSD(T)-F12b), and extrapolation to the complete basis set (CBS) limit using the cc-pVTZ-F12/cc-pVQZ-F12 bases and the l –3 formula. An analytic representation of the 4D-PES was fitted using the method of interpolating moving least squares (IMLS). These calculations predict that the most stable configuration of CO 2 –O 2 complex corresponds to a planar slipped-parallel structure with a binding energy of V ~ –243 cm –1 . Another isomer is found on the PES, corresponding to a non-planar cross-shaped structure, with V ~ –218 cm –1 . The transition structure connecting the two minima is found at V ~ –211 cm –1 . We also performed comparisons with some CO 2 –X van der Waals complexes. Moreover, we provide a SAPT analysis of this molecular system. Then, we discuss the complexation induced shifts of CO 2 and O 2 . Afterwards, this new 4D-PES is employed to compute the second virial coefficient including temperature dependence. A comparison between quantities obtained in our calculations and those from experiments found close agreement attesting to the high quality of the PES and to the importance of considering a full description of the anisotropic potential for the derivation of thermophysical properties of CO 2 –O 2 mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of resonant layer response in electron viscosity regime

We present a supplementary study of previous work in Waybright and Park [Phys. Plasmas 31, 022502 (2024)] which demonstrates a substantial effect of electron viscosity on the resonant layer response to non-axisymmetric magnetic perturbations. A main refinement is to include a curl element of electron viscosity in the generalized Ohm's law. The refinement reveals a resonant layer response in the electron viscosity regime corresponding to slowly rotating and highly viscous plasmas.

Asymptotic analysis↗

Effects of Uranium Impurities in Downblended HEU on HTGR Performance

Many advanced reactor designs require fuel enriched between 5% and 20% 235 U. To assist in producing fuel at these enrichment levels, government-owned inventories of highly enriched uranium can be downblended. However, fuel produced from these inventories contain uranium impurities that are not often found when enriching natural uranium or accounted for when modeling reactor cores. To address this concern, this work models reactor designs like the X-energy Xe-100 and the Ultra Safe Nuclear Company’s Micro Modular Reactor, and compares their performance with fuel from enriching natural uranium to fuel from downblended highly enriched uranium. This paper evaluates the models based on the effective neutron multiplication factor, k eff , effective delayed neutron fraction, β eff , and energy- and spatially dependent neutron flux, ϕ, as well as the fuel, coolant, moderator, and total reactivity temperature feedback coefficients, α F , α C , α M , and α T . The results show that the fuel from downblended highly enriched uranium inventories leads to differences in each of the metrics, especially in the keff values. In the Xe-100–like and Micro Modular Reactor–like models, k eff changes by about 1400 pcm and up to 1200 pcm, respectively. Total reactivity feedback coefficients α T are negative with the impure fuels and the keff values remain above 1 for each core configuration and fuel composition. These results show that the impure fuel compositions do not necessarily prevent achieving key design parameters, such as cycle length, or from operating in a safe condition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Structural modulation, physical properties, and electronic band structure of the kagome metal UCr 6 ⁢Ge 6

The chemical flexibility of the 𝑅⁢𝑀 6 ⁢𝑋 6 stoichiometry, where an 𝑓-block element is intercalated in the CoSn structure type, allows for the tuning of flatbands associated with kagome lattices to the Fermi level and for emergent phenomena due to interactions between the 𝑓- and 𝑑-electron lattices. Yet, 5⁢𝑓 members of the “166” compounds are underrepresented compared with 4⁢𝑓 members. In this work, we report single-crystal growth of UCr 6 ⁢Ge 6 , which crystallizes in a monoclinically distorted Y 0.5⁢ Co 3 ⁢Ge 3 -type structure. The real-space character of the modulation, which is unique within the 𝑅⁢𝑀 6 ⁢𝑋 6 family, is approximated by a 3×1×2 supercell of the average monoclinic cell. The compound has kagome-lattice flatbands near the Fermi level and a moderately enhanced electronic heat capacity, as evidenced by its low-temperature Sommerfeld coefficient (𝛾=86.5 mJ mol −1 K −2 ) paired with band structure calculations. The small, isotropic magnetization and featureless resistivity of UCr 6 ⁢Ge 6 suggest itinerant uranium 5⁢𝑓 electrons and Pauli paramagnetism. Angle-resolved photoemission spectroscopy results provide evidence for uranium 5⁢𝑓 weight at the Fermi level and for a flatband near the Fermi level associated with the chromium 3⁢𝑑 kagome lattice. The isotropic magnetic behavior of the uranium 5⁢𝑓 electrons starkly contrasts with localized behavior in other uranium 166 compounds, highlighting the high tunability of the magnetic ground state across the material family.

36 MATERIALS SCIENCE↗

Impact of Irradiation-Induced Filter Heating on Calibration of NIR-Longpass-Filtered Reference Solar Cells

Reference solar cells play a crucial role in determining the performance of photovoltaic (PV) devices. In the performance calibration chain of mainstream single-junction PV technologies, common reference cell types include Si, KG-filtered Si, and GaAs cells. For emerging multijunction (MJ) PV technologies, such as CdTe/Si and perovskite/Si, Si reference cells with colored glass near-infrared-longpass (LP) filters like Schott RG-715 and 850 glass have been proposed. They offer a better spectral response that matches the bottom junctions of the emerging MJs, which could lead to lower uncertainties in performance measurements. However, this article reveals a prominent decrease in short-circuit current (ISC) during National Renewable Energy Laboratory's primary calibration over the course of minutes when using this type of LP-filtered reference cell, which could result in unacceptable measurement errors. Unlike quartz or KG filter glasses, LP colored glass filters demonstrate temperature-sensitive cut-on wavelength. When incident irradiance reaches these LP-filtered reference cells, the increased temperature due to light absorption causes a shift of the cut-on to longer wavelength. As a result, the device I SC exhibits a continuous decrease (approximately a 2.5% drop with RG850 LP filter in a 5-min duration) even when the device temperature is controlled at 25 degrees C. To address the temperature gradient issue between colored glass LP filter and the reference cell, we propose the direct integration of thin-film LP semiconductor layer on reference cells. This type of LP-filter-integrated cell has shown minimal temperature-related I SC variation and can serve as a more reliable reference cell source for accurate performance measurements.

14 SOLAR ENERGY↗

SCALE Modeling of the Fast Spectrum Heat Pipe Reactor

As part of the severe accident analysis collaboration with Sandia National Laboratories (SNL) and the Nuclear Regulatory Commission (NRC), SCALE models were developed for a fast-spectrum heat pipe reactor. These models were based on the Idaho National Laboratory (INL) Design A concept, which is an alternative design to the Los Alamos National Laboratory (LANL) Special Purpose Reactor (SPR), also known as the Megapower reactor. The model contains 1,134 heat pipes, surrounded by hexagonal fuel elements, with a potassium working fluid; the fuel is UO 2 with 19.75 wt% 235 U enrichment. The model contains axial beryllium oxide (BeO) reflectors above and below the active fuel region along with a radial alumina reflector containing 12 B 4 C control drums. The center of the core is left unfueled to make room for two shutdown control rods, one annular and one solid. The active region of the core was discretized into twenty axial and five radial zones to analyze spatial variations in power and burnup. Infinite lattice unit cell sensitivity studies were used to perform verification between the SCALE and INL models. The eigenvalue results agreed well with the reported results to within roughly 50 percent mille (pcm). Full-core model verification was performed by analyzing system eigenvalues with differing configurations of control drum and shutdown rod positions. These full core results all had eigenvalue differences less than 310 pcm. Control drum and shutdown rod worths were also compared, with differences of 3.2% or less. Using the verified model, the isotopic inventory and decay heat, as well as temperature feedback coefficients, were calculated and provided to SNL as input to the MELCOR severe accident code to analyze potential releases from this class of reactor. The results of the MELCOR analysis are provided in a different report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Test and Evaluation of Solar Foil Directly Mounted on the Ground (Final Report)

HyET Solar (HyET), established in 2012, is a small business developing a thin-film silicon solar photovoltaic (PV) product called "Power Foil" that can be mounted directly on the constructed earthen dykes. HyET's goals are for low-cost, efficient, generation of PV electricity at utility scale. HyET has requested assistance from the National Renewable Energy Laboratory (NREL) to evaluate the performance of the Power Foil product in several outdoor environments, with a particular focus on 1) heat effects on efficiency and 2) heat and UV effects on reliability and durability. NREL has been working on PV module testing at laboratory scale for more than 40 years, and has the equipment and facilities required to provide the PV material testing required.

14 SOLAR ENERGY↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Measurements of turbulence profiles in the troposphere.

During a series of balloon flights in southeastern New Mexico new data was obtained on microthermal atmospheric turbulence structure from the surface to altitudes of 12 to 15 km and the beginning of the tropopause region. It was possible to compute the temperature structure coefficient and the refractive-index-structure coefficient. The major significance of the data is the thermal evidence for turbulence and the strength of this effect in the upper-altitude regions.

Bufton, J. L.↗

Elementary solutions of coupled model equations in the kinetic theory of gases

The method of elementary solutions is employed to solve two coupled integrodifferential equations sufficient for determining temperature-density effects in a linearized BGK model in the kinetic theory of gases. Full-range completeness and orthogonality theorems are proved for the developed normal modes and the infinite-medium Green's function is constructed as an illustration of the full-range formalism. The appropriate homogeneous matrix Riemann problem is discussed, and half-range completeness and orthogonality theorems are proved for a certain subset of the normal modes. The required existence and uniqueness theorems relevant to the H matrix, basic to the half-range analysis, are proved, and an accurate and efficient computational method is discussed. The half-space temperature-slip problem is solved analytically, and a highly accurate value of the temperature-slip coefficient is reported.

Kriese, J. T.↗