Investigation of the Damping of Liquids in Right-Circular Cylindrical Tanks, Including the Effects of a Time-Variant Liquid Depth

An experimental investigation was conducted to determine the effects of several basic variables upon the damping of the fundamental antisymmetric mode of liquids in right-circular cylindrical tanks without baffles. The variables examined include liquid depth, efflux rate, liquid amplitude, kinematic viscosity, and tank size. The data are presented in dimensionless form and compared with available theory. For the range of variables examined, variations of efflux rate and liquid amplitude were found to have no significant effects on the liquid damping. The following theoretical relationship was found to be adequate for the prediction of the variation of damping with liquid depth, kinematic viscosity, and tank size: [for equation see full text] where v is the kinematic viscosity, R is the cylinder radius, g is the acceleration due to gravity, and h is the liquid depth. However, the constant K was experimentally found in this investigation to have the value 5.23, which is 50 percent higher than the theoretically predicted value.

TANK↗

Physics-Based Fragment Acceleration Modeling for Pressurized Tank Burst Risk Assessments

As part of comprehensive efforts to develop physics-based risk assessment techniques for space systems at NASA, coupled computational fluid and rigid body dynamic simulations were carried out to investigate the flow mechanisms that accelerate tank fragments in bursting pressurized vessels. Simulations of several configurations were compared to analyses based on the industry-standard Baker explosion model, and were used to formulate an improved version of the model. The standard model, which neglects an external fluid, was found to agree best with simulation results only in configurations where the internal-to-external pressure ratio is very high and fragment curvature is small. The improved model introduces terms that accommodate an external fluid and better account for variations based on circumferential fragment count. Physics-based analysis was critical in increasing the model's range of applicability. The improved tank burst model can be used to produce more accurate risk assessments of space vehicle failure modes that involve high-speed debris, such as exploding propellant tanks and bursting rocket engines.

Acceleration↗

Modeling ARRM Xenon Tank Pressurization Using 1D Thermodynamic and Heat Transfer Equations

As a first step in understanding what ground support equipment (GSE) is required to provide external cooling during the loading of 5,000 kg of xenon into 4 aluminum lined composite overwrapped pressure vessels (COPVs), a modeling analysis was performed using Microsoft Excel. The goals of the analysis were to predict xenon temperature and pressure throughout loading at the launch facility, estimate the time required to load one tank, and to get an early estimate of what provisions for cooling xenon might be needed while the tanks are being filled. The model uses the governing thermodynamic and heat transfer equations to achieve these goals. Results indicate that a single tank can be loaded in about 15 hours with reasonable external coolant requirements. The model developed in this study was successfully validated against flight and test data. The first data set is from the Dawn mission which also utilizes solar electric propulsion with xenon propellant, and the second is test data from the rapid loading of a hydrogen cylindrical COPV. The main benefit of this type of model is that the governing physical equations using bulk fluid solid temperatures can provide a quick and accurate estimate of the state of the propellant throughout loading which is much cheaper in terms of computational time and licensing costs than a Computation Fluid Dynamics (CFD) analysis while capturing the majority of the thermodynamics and heat transfer.

Xenon storage↗

Modeling Xenon Tank Pressurization using One-Dimensional Thermodynamic and Heat Transfer Equations

As a first step in understanding what ground support equipment (GSE) is required to provide external cooling during the loading of 5,000 kg of xenon into 4 aluminum lined composite overwrapped pressure vessels (COPVs), a modeling analysis was performed using Microsoft Excel. The goals of the analysis were to predict xenon temperature and pressure throughout loading at the launch facility, estimate the time required to load one tank, and to get an early estimate of what provisions for cooling xenon might be needed while the tanks are being filled. The model uses the governing thermodynamic and heat transfer equations to achieve these goals. Results indicate that a single tank can be loaded in about 15 hours with reasonable external coolant requirements. The model developed in this study was successfully validated against flight and test data. The first data set is from the Dawn mission which also utilizes solar electric propulsion with xenon propellant, and the second is test data from the rapid loading of a hydrogen cylindrical COPV. The main benefit of this type of model is that the governing physical equations using bulk fluid solid temperatures can provide a quick and accurate estimate of the state of the propellant throughout loading which is much cheaper in terms of computational time and licensing costs than a Computation Fluid Dynamics (CFD) analysis while capturing the majority of the thermodynamics and heat transfer.

Thermodynamic tank modeling↗

Axisymmetric Two-Dimensional Modeling of No Vent Filling of a Cryogenic Tank using Generalized Fluid System Simulation Program

This paper presents preliminary analysis using a finite volume based computational method for network flow analysis for the simulation of chill and fill of a cryogenic tank. An axisymmetric two-dimensional model of a spherical tank was developed using a nodal approach. No Vent Filling (NVF) was accomplished using a Thermodynamic Vent System assisted injector where the injector was cooled by the cold gas generated by Joule-Thompson expansion of the liquid propellant. The numerical model accounts for a) different regimes of pool boiling heat transfer, b) condensation of vapor around spray droplets, and c) condensation of vapor at the interface of the cooled injector and ullage. The numerical predictions of tank pressure, filling rate, and wall temperatures were compared with the test data and one-dimensional (1D) model predictions. It was demonstrated that the axisymmetric 2D model provided a more realistic prediction than the 1D model.

Cryogenics↗

Nodal Modeling of Submerged Helium Injection Pressurization of a Cryogenic Propellant Tank

Subcooling of cryogenic propellant by helium injection is one of the most effective methods for suppressing bulk boiling and keeping subcooled propellant conditions for pre-launch, launch, and post-launch pressurization applications. For tank pressurization, submerged helium injection can substantially reduce helium consumption by infusing gaseous propellant into the tank ullage. This paper describes a thermodynamic model of the helium bubbling process in liquid oxygen to estimate the amount of oxygen vapor absorbed by the rising helium bubbles and the amount of subcooling of liquid oxygen due to evaporative heat and mass transfer. The physics of helium dissolution during the pressurization process is also modeled, primarily for liquid hydrogen propellant where the dissolution is more significant. The analyses were performed in a simulation model of tank pressurization built with Generalized Fluid System Simulation Program (GFSSP), a general-purpose flow network code developed at NASA/Marshall Space Flight Center. The numerical predictions of subcooling have been compared with the experimental data of Cho et al. which investigated the propellant subcooling effect as a function of system pressure, helium injection temperature, and flowrate for a non-drained submerged injection system. The numerical predictions of helium consumption have been compared with the test data from a NASA Centaur test vehicle which included both direct and submerged injection with draining of propellants. Hydrogen propellant testing of the Cryogenic Propellant Storage and Transfer Engineering Developmental Unit (CPST EDU) conducted at NASA/Glenn Research Facility was also analyzed. The data used for the model validation were taken in 1-g, but the model was developed to be applicable in both multi-g and micro-g environments.

tank pressurization↗

Nodal Modeling of Tank Pressurization and Draining using a Multi-Node-Ullage Approach

Pressurized expulsion tests of liquid methane were modeled by a nodal code using a multinode ullage approach. Generalized Fluid System Simulation Program (GFSSP), a finite volume based nodal code was used to model the expulsion of liquid methane from a 1.52-meter (5 ft) diameter spherical tank by pressurizing with helium and gaseous methane. The purpose of the model was to estimate the amount of pressurant required and amount of condensation and evaporation of methane during the operation. The ullage was discretized into multiple nodes and each fluid node was connected to solid nodes. Both the fluid and solid nodes grow as the tank drains. The heat and mass transfer between fluid and solid node in the tank ullage was computed. The heat and mass transfer between the bottom ullage node and the liquid methane was also computed. The model predictions were compared with data from twelve test cases. The predicted pressurant consumption for helium pressurization compares with test data with a Mean Absolute Percent Error (MAPE) of 3 %. For autogenous pressurization, where gaseous methane was used to pressurize liquid methane, the predicted pressurant consumption compares with a MAPE of 6%.

Cryogenic Propellant↗

CFD-Assisted Nodal Modeling of Sloshing in a Cryogenic Propellant Tank

During autogenous pressurization, tank sloshing causes a significant increase in pressurant consumption to maintain constant ullage pressure during draining of the tank. This increase in pressurant consumption is caused by a significant increase in condensation at the liquid-vapor interface. Sloshing strongly affects the liquid side heat transfer coefficient and thereby the condensation rate. Traditionally, sloshing is modeled by CFD code using the VOF (Volume of Fluid) method to track the liquid vapor interface during sloshing. CFD calculations require a very fine grid to accurately compute the heat and mass transfer at the interface. Therefore, computations are time consuming and prohibit performing many parametric studies often needed during the design of a new system. This paper describes an alternative approach by developing a CFD-assisted nodal model to predict system parameters more economically with reasonable accuracy. In this approach, a multi-node model of tank pressurization was developed using GFSSP. A multi-node model was needed to account for stratification. The model computes heat and mass transfer at the interface to calculate the condensation rate. The liquid side heat transfer is computed using the parameters of sloshing dynamics such as frequency, wave amplitude, and interface area. The parameters of sloshing dynamics are computed by the CFD code LOCI-Stream. The model predictions were compared with test data for several cases.

Cryogenic Tank Sloshing↗

Device without electrical connections in tank measures liquid level

Vertical static float in a tank measures the liquid level without the use of electrical connections in the tank. The float transmits the buoyant force of the liquid to an external force transducer. It is insensitive to tank pressure and temperature changes.

Shenkman, J. S.↗

In-tank shutoff valve is provided with maximum blast protection

In-tank shutoff valve is installed with the valve poppet and actuator inside the tank to provide maximum blast protection during rocket engine test operation. This valve design is applicable wherever explosive fuels are used and is currently being used in lox and liquid hydrogen tanks at a rocket engine test site.

Holden, C. F.↗

Composite overwrapped metallic tanks

Work is reported for fabricating and testing the fiberglass overwrapped titanium pressure vessel for cryogenic service. Difficulties encountered in the tank liner fabrication phase involved explosive forming, vacuum annealing, chemical milling and electron beam welding. While each of these processes and the nondestructive test methods employed are normally considered to be individually reliable, the combination of poor material together with fabrication and development reversals prevented the full achievement of the desired end results. Eight tanks plus a prototype and tool proofing article were produced. Six of the vessels failed during the hydrostatic sizing operation. One of the remaining tanks was hydrostatically pressurized to burst and the other was pressurized repeatedly at 75 F from 100 psi to the operating pressure until failure occurred. As a result, it is not possible to draw firm conclusions as to the true value of the design concept due to the problems encountered in the program.

Caudill, C. L.↗

Modified Apollo cryogenic oxygen tank design

Assessment of the Apollo 13 mission indicated that some design changes to be incorporated into Apollo cryogenic oxygen storage tanks. These changes broadly fit into three categories. They were: (1) deletion of the fluid equilibration motors and redesign of heater assembly, (2) material changes for internal tank wiring and density sensor, and (3) the addition of a heater assembly temperature sensor. Development of a cryogenic oxygen tank incorporating these changes is presented.

Vanleuven, K.↗

Prediction of the effects of thermal stratification on pressure and temperature response of the Apollo supercritical oxygen tank

A semiempirical design-oriented model has been developed for the prediction of the effects of thermal stratification on tank pressure and heater temperature response for the Apollo supercritical oxygen tank. The heat transfer formulation describes laminar free convection at low-g and takes into account the radiation and conduction processes occurring in the tank. The nonequilibrium thermodynamic behavior of the system due to localized heating of the stored fluid is represented by the characteristics of a discrete number of fluid regions and thermal nodes. Solutions to the time dependent variable fluid property problem are obtained through the use of a reference temperature procedure. A criterion which establishes the reference temperature as a function of the fluid density ratio is derived. The analytical results are compared with the flight data.

Chen, I. M.↗

Vehicle-scale investigation of a fluorine jet-pump liquid hydrogen tank pressurization system

A comprehensive analytical and experimental program was performed to evaluate the performance of a fluorine-hydrogen jet-pump injector for main tank injection (MTI) pressurization of a liquid hydrogen (LH2) tank. The injector performance during pressurization and LH2 expulsion was determined by a series of seven tests of a full-scale injector and MTI pressure control system in a 28.3 cu m (1000 cu ft) flight-weight LH2 tank. Although the injector did not effectively jet-pump LH2 continuously, it showed improved pressurization performance compared to straight-pipe injectors tested under the same conditions in a previous program. The MTI computer code was modified to allow performance prediction for the jet-pump injector.

Cady, E. C.↗

Floating baffle to improve efficiency of liquid transfer from tanks

When liquid tank is full, baffle is held up against a stop on top of shaft to prevent restriction of flow from outlet. As tank is being emptied, baffle, floating on top of liquid surface, descends with liquid level toward outlet until it reaches its bottom stop. Baffle prevents gas pull-through until practically all liquid is emptied from tank.

Howard, F. S.↗

Acoustic-emission signal-processing analog unit for locating flaws in large tanks

Technique monitors structural flaws in 105-in. diameter tanks. Tank surface is divided into many areas and each area is sectioned into 20 equilateral triangles that form icosahedron. Twelve transducers are equally positioned on tank surface at vertex of each triangle. Transducers monitor area for flaws by detecting any increase in acoustical activity.

Moskal, F. J.↗

Space shuttle: Preliminary pressure distributions on the 049 orbiter, orbiter in presence of H/O tank and orbiter in launch configuration

The 049 orbiter and launch configurations were tested in a trisonic wind tunnel to obtain preliminary loads information on the orbiter alone, orbiter in presence of the H/O tank and orbiter in the full launch configuration. The orbiter consisted of the baseline 049 double-delta wing, twin vertical stabilizers, seven degrees of dihedral and included abort rockets. The orbiter was mounted at minus 1.50 degree of incidence (fuselage centerline relative to H/O tank centerline) in the launch configuration. The solid rocket motors were mounted at a radial location of 21 degrees from the horizontal centerline of the H/O tank. The test was conducted over a Mach number range of 0.6 to 4.96. Nominal angle of attack and angle of sideslip ranges of minus 6 to plus 6 degrees were tested. In addition, the orbiter alone was tested over an angle of attack range of minus 6 to plus 26 degrees.

Hamilton, J. T.↗

Development of advanced material composites for use as internal insulation for LH2 tanks (gas layer concept)

A program is described that was conducted to develop an internal insulation system for potential application to the liquid hydrogen tanks of a reusable booster, where the tanks would be subjected to repeated high temperatures. The design of the internal insulation is based on a unique gas layer concept, in which capillary or surface tension effects are used to maintain a stable gas layer, within a cellular core structure, between the tank wall and the contained liquid hydrogen. Specific objectives were to select materials for insulation systems that would be compatible with wall temperatures of 350 F and 650 F during reentry into the earth's atmosphere, and to fabricate and test insulation systems under conditions simulating the operating environment. A materials test program was conducted to evaluate the properties of candidate materials at elevated temperatures and at the temperature of liquid hydrogen, and to determine the compatibility of the materials with a hydrogen atmosphere at the appropriate elevated temperature. The materials that were finally selected included Kapton polyimide films, silicone adhesives, fiber glass batting, and in the case of the 350 F system, Teflon film.

Gille, J. P.↗