Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

High Accuracy Wavelength Calibration For A Scanning Visible Spectrometer

Spectroscopic applications for plasma velocity measurements often require wavelength accuracies ≤ 0.2Â. An automated calibration for a scanning spectrometer has been developed to achieve a high wavelength accuracy overr the visible spectrum, stable over time and environmental conditions, without the need to recalibrate after each grating movement. The method fits all relevant spectrometer paraameters using multiple calibration spectra. With a steping-motor controlled sine-drive, accuracies of ~0.025 Â have been demonstrated. With the addition of high resolution (0.075 aresec) optical encoder on the grading stage, greater precision (~0.005 Â) is possible, allowing absolute velocity measurements with ~0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prototype Neutron Energy Spectrometer

The project goals are: (1) Use three to five pressurized helium tubes with varying polyethylene moderators to build a neutron energy spectrometer that is most sensitive to the incident neutron energy of interest. Neutron energies that are of particular interest are those from the fission neutrons (typically around 1-2 MeV); (2) Neutron Source Identification - Use the neutron energy 'selectivity' property as a tool to discriminate against other competing processes by which neutrons are generated (viz. Cosmic ray induced neutron production [ship effect], [a, n] reactions); (3) Determine the efficiency as a function of neutron energy (response function) of each of the detectors, and thereby obtain the composite neutron energy spectrum from the detector count rates; and (4) Far-field data characterization and effectively discerning shielded fission source. Summary of the presentation is: (1) A light weight simple form factor compact neutron energy spectrometer ready to be used in maritime missions has been built; (2) Under laboratory conditions, individual Single Neutron Source Identification is possible within 30 minutes. (3) Sources belonging to the same type of origin viz., (a, n), fission, cosmic cluster in the same place in the 2-D plot shown; and (4) Isotopes belonging to the same source origin like Cm-Be, Am-Be (a, n) or Pu-239, U-235 (fission) do have some overlap in the 2-D plot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tracking Elevated Pollution Layers with a Newly Developed Hyperspectral Sun/Sky Spectrometer (4STAR): Results from the TCAP 2012 and 2013 Campaigns

Total columnar amounts of water vapor, nitrogen dioxide (NO2) and ozone (O3) are derived from a newly developed, hyperspectral airborne sun-sky spectrometer (4STAR) for the first time during the two intensive phases of the Two Column Aerosol Project (TCAP) in summer 2012 and winter 2013 aboard the DOE G-1 aircraft. We compare results with coincident measurements. We find 0.045 g/cm2 (4.2%) negative bias and 0.28 g/cm2 (26.3%) root-mean-square (RMS) difference in water vapor layer comparison with in-situ hygrometer, and an overall RMS difference of 1.28 g/m3 (38%) water vapor amount in profile by profile comparisons, with differences distributed evenly around zero in most cases. The RMS differences for O3 values average to 3%, with a 1% negative bias for 4STAR compared with the spaceborne Ozone Measuring Instrument (OMI) along the aircraft flight-track for 14 flights during both TCAP phases. Ground-based comparisons with the Pandora spectrometer system at the Goddard Space Flight Center (GSFC), Greenbelt, Maryland showed excellent agreement between the instruments for both O3 and NO2, further emphasizing 4STAR’s new capabilities. During the summer phase, we have succeeded in identifying variations in elevated pollution layers corresponding to urban pollution outflow and transported biomass burning. This was done using clustering analysis of the retrieved products (e.g. Ångstrom exponent, NO2 and columnar water vapor), and was confirmed by aerosol type identification by HSRL2 aboard the NASA B-200 aircraft. These newly demonstrated 4STAR capabilities are expected to be instrumental in improving our understanding of atmospheric composition variability and aerosol-trace-gas interactions; they open new horizons and opportunities in airborne sunphotometry.

4STAR↗

Airborne Single Particle Mass Spectrometers (SPLAT II & miniSPLAT) and New Software for Data Visualization and Analysis in a Geo-Spatial Context

Understanding the effect of aerosols on climate requires knowledge of the size and chemical composition of individual aerosol particles - two fundamental properties that determine an aerosol’s optical properties and ability to serve as cloud condensation or ice nuclei. Here we present miniSPLAT, our new aircraft compatible single particle mass spectrometer, that measures in-situ and in real-time size and chemical composition of individual aerosol particles with extremely high sensitivity, temporal resolution, and sizing precision on the order of a monolayer. miniSPLAT operates in dual data acquisition mode to measure, in addition to single particle size and composition, particle number concentrations, size distributions, density, and asphericity with high temporal resolution. When compared to our previous instrument, SPLAT II, miniSPLAT has been significantly reduced in size, weight, and power consumption without loss in performance. We also present ND-Scope, our newly developed interactive visual analytics software package. ND-Scope is designed to explore and visualize the vast amount of complex, multidimensional data acquired by our single particle mass spectrometers, along with other aerosol and cloud characterization instruments on-board aircraft. We demonstrate that ND-Scope makes it possible to visualize the relationships between different observables and to view the data in a geo-spatial context, using the interactive and fully coupled Google Earth and Parallel Coordinates displays. Here we illustrate the utility of ND-Scope to visualize the spatial distribution of atmospheric particles of different compositions, and explore the relationship between individual particle composition and their activity as cloud condensation nuclei.

54 ENVIRONMENTAL SCIENCES↗

Isobar Separation in a Multiple-Reflection Time-of-Flight Mass Spectrometer by Mass-Selective Re-Trapping

A novel method for (ultra-)high-resolution spatial mass separation in time-of-flight mass spectrometers is presented. Ions are injected into a time-of-flight analyzer from a radio frequency (rf) trap, dispersed in time-of-flight according to their mass-to-charge ratios and then re-trapped dynamically in the same rf trap. This re-trapping technique is highly mass-selective and after sufficiently long flight times can provide even isobaric separation. A theoretical treatment of the method is presented and the conditions for optimum performance of the method are derived. The method has been implemented in a multiple-reflection time-of-flight mass spectrometer and mass separation powers (FWHM) in excess of 70,000, and re-trapping efficiencies of up to 35% have been obtained for the protonated molecular ion of caffeine. The isobars glutamine and lysine (relative mass difference of 1/4000) have been separated after a flight time of 0.2 ms only. Higher mass separation powers can be achieved using longer flight times. The method will have important applications, including isobar separation in nuclear physics and (ultra-)high-resolution precursor ion selection in multiple-stage tandem mass spectrometry. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mobility Peak Tailing Reduction in a Differential Mobility Analyzer (DMA) Coupled with a Mass Spectrometer and Several Ionization Sources

The differential mobility analyzer (DMA) is a narrow-band linear ion mobility filter operating at atmospheric pressure. It combines in series with a quadrupole mass spectrometer (Q-MS) for mobility/mass analysis, greatly reducing chemical noise in selected ion monitoring. However, the large flow rate of drift gas (~1000 L/min) required by DMAs complicates the achievement of high gas purity. Additionally, the symmetry of the drying counterflow gas at the interface of many commercial MS instruments, is degraded by the lateral motion of the drift gas at the DMA entrance slit. As a result, DMA mobility peaks often exhibit tails due to the attachment of impurity vapors, either (1) to the reagent ion within the separation cell, or (2) to the analyte of interest in the ionization region. In order to greatly increase the noise-suppression capacity of the DMA, we describe various vapor-removal schemes and measure the resulting increase in the tailing ratio, (TR = signal at the peak maximum over signal two half-widths away from this maximum). Here we develop a low-outgassing DMA circuit connected to a mass spectrometer, and test it with three ionization sources (APCI, Desolvating-nano ESI, and Desolvating low flow SESI). While prior TR values were in the range 100–1000, the three new sources achieve TR ~ 10{sup 5}. The SESI source has been optimized for maximum sensitivity, delivering an unprecedented gain for TNT of 190 counts/fg, equivalent to an ionization efficiency of one out of 140 neutral molecules. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Analysis of Organic Compounds in Liquid Using a Miniature Photoionization Ion Trap Mass Spectrometer with Pulsed Carrier-Gas Capillary Inlet

A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Nature of Mass Spectrometer Analyzer Contamination

Sample throughput in electrospray ionization mass spectrometry (ESI-MS) is limited by the need for frequent ion path cleaning to remove accumulated debris that can lead to charging and general performance degradation. Contamination of ion optics within the vacuum system is particularly problematic as routine cleaning requires additional time for cycling the vacuum pumps. Differential mobility spectrometry (DMS) can select targeted ion species for transmission, thereby reducing the total number of charged particles entering the vacuum system. In this work, we characterize the nature of instrument contamination, describe efforts to improve mass spectrometer robustness by applying DMS prefiltering to reduce contamination of the vacuum ion optics, and demonstrate the capability of DMS to extend the interval between mass spectrometer cleaning. In addition, we introduce a new approach to effectively detect large charged particles formed during the electrospray ionization (ESI) process. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MONSTER: a TOF Spectrometer for β-delayed Neutron Spectroscopy

β-delayed neutron (DN) data, including emission probabilities, Pn, and energy spectrum, play an important role in our understanding of nuclear structure, nuclear astrophysics and nuclear technologies. A MOdular Neutron time-of-flight SpectromeTER (MONSTER) is being built for the measurement of the neutron energy spectra and branching ratios. The TOF spectrometer will consist of one hundred liquid scintillator cells covering a significant solid angle. The MONSTER design has been optimized by using Monte Carlo (MC) techniques. The response function of the MONSTER cell has been characterized with mono-energetic neutron beams and compared to dedicated MC simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of position-sensitive time-of-flight spectrometer for fission fragment research

A position-sensitive, high-resolution time-of-flight detector for fission fragments has been developed. The SPectrometer for Ion DEtermination in fission Research (SPIDER) is a 2E–2v spectrometer designed to measure the mass of light fission fragments to a single mass unit. The time pick-off detector pairs to be used in SPIDER have been tested with α-particles from 229Th and its decay chain and α-particles and spontaneous fission fragments from 252Cf. Each detector module is comprised of thin electron conversion foil, electrostatic mirror, microchannel plates, and delay-line anodes. Particle trajectories on the order of 700 mm are determined accurately to within 0.7 mm. Flight times were measured with 250 ps resolution FWHM. Computed particle velocities are accurate to within 0.06 mm/ns corresponding to a precision of 0.5%. As a result, an ionization chamber capable of 400 keV energy resolution coupled with the velocity measurements described here will pave the way for modestly efficient measurements of light fission fragments with unit mass resolution.

2E-2v↗

Refining instrument response functions with 3-D Monte Carlo simulations of differential hard x-ray spectrometers

Three x-ray spectrometers – the hard x-ray detector (HXRD), the bremsstrahlung MeV x-ray spectrometer (BMXS), and the hard x-ray image plate (HXIP) – areused here to estimate hot-electron bremsstrahlung spectrum parameters for inertial confinement fusion experiments on OMEGA. Using 1-D deterministically calculated response functions, they show significantly different estimates of spectrum slope temperature. For all three detectors, 3-D Geant4 Monte Carlo simulations are developed and used to compute instrument response functions. Simulations explain features in raw image-plate data, but only significantly improve systematic errors in predicted detector channel signals for BMXS and do not entirely eliminate the discrepancy between estimates of slope temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time interval distributions of nuclear events in a digital spectrometer

This study compares the theoretical formula for time interval density distributions (TIDs) in counters with pileup rejection to TIDs measured using a digital spectrometer with trapezoid filtering. The TIDs were derived from successive time stamps of 60 Co and 133 Ba γ rays detected with a HPGe spectrometer. The results demonstrate that the theoretical formula is applicable up to 40% count loss and can be used to retrospectively deduce the incident event rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The super separator spectrometer (S{sup 3}) for SPIRAL2 stable beams.

S{sup 3} (Super Separator Spectrometer) is a device designed for experiments with the very high intensity stable beams of LINAG, the superconducting linear accelerator of GANIL, which will be built in the framework of SPIRAL2. These beams can reach intensities exceeding 100p{mu}A for lighter ions. These unprecedented intensities open new opportunities in several physics domains, e.g. super-heavy and very-heavy element properties, spectroscopy at and beyond the dripline, isomer and ground state properties, and the products of multi-nucleon transfer and deep-inelastic reactions. An international collaboration has been formed for proposing physics experiments and developing technical solutions for this new instrument. We present here the optical layout of the spectrometer and the studies of its multipole magnets.

43 PARTICLE ACCELERATORS↗

First measurements of the absolute neutron spectrum using the magnetic recoil spectrometer at OMEGA (invited)

A neutron spectrometer, called a magnetic recoil spectrometer (MRS), has been built and implemented at the OMEGA laser facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] for absolute measurements of the neutron spectrum in the range of 6-30 MeV, from which fuel areal density ({rho}R), ion temperature (T{sub i}), and yield (Y{sub n}) can be determined. The results from the first MRS measurements of the absolute neutron spectrum are presented. In addition, measuring {rho}R at the National Ignition Facility (NIF) [G. H. Miller et al., Nucl. Fusion 44, S228 (2004)] will be essential for assessing implosion performance during all stages of development from surrogate implosions to cryogenic fizzles to ignited implosions. To accomplish this, we are also developing an MRS for the NIF. As much of the research and development and instrument optimization of the MRS at OMEGA are directly applicable to the MRS at the NIF, a description of the design and characterization of the MRS on the NIF is discussed as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The multiplexed chemical kinetic photoionization mass spectrometer: A new approach to isomer-resolved chemical kinetics

We have developed a multiplexed time- and photon-energy-resolved photoionization mass spectrometer for the study of the kinetics and isomeric product branching of gas phase, neutral chemical reactions. The instrument utilizes a side-sampled flow tube reactor, continuously tunable synchrotron radiation for photoionization, a multimass double-focusing mass spectrometer with 100% duty cycle, and a time- and position-sensitive detector for single ion counting. This approach enables multiplexed, universal detection of molecules with high sensitivity and selectivity. In addition to measurement of rate coefficients as a function of temperature and pressure, different structural isomers can be distinguished based on their photoionization efficiency curves, providing a more detailed probe of reaction mechanisms. The multiplexed three-dimensional data structure (intensity as a function of molecular mass, reaction time, and photoionization energy) provides insights that might not be available in serial acquisition, as well as additional constraints on data interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A broadband absorption spectrometer using light emitting diodes for ultrasensitive, in situ trace gas detection

A broadband absorption spectrometer has been developed for highly sensitive and target-selective in situ trace gas measurements. The instrument employs two distinct modes of operation: (i) broadband cavity enhanced absorption spectroscopy (BBCEAS) is used to quantify the concentration of gases in sample mixtures from their characteristic absorption features, and (ii) periodic measurements of the cavity mirrors' reflectivity are made using step-scan phase shift cavity ringdown spectroscopy (PSCRDS). The latter PSCRDS method provides a stand-alone alternative to the more usual method of determining mirror reflectivities by measuring BBCEAS absorption spectra for calibration samples of known composition. Moreover, the instrument's two modes of operation use light from the same light emitting diode transmitted through the cavity in the same optical alignment, hence minimizing the potential for systematic errors between mirror reflectivity determinations and concentration measurements. The ability of the instrument to quantify absorber concentrations is tested in instrument intercomparison exercises for NO{sub 2} (versus a laser broadband cavity ringdown spectrometer) and for H{sub 2}O (versus a commercial hygrometer). A method is also proposed for calculating effective absorption cross sections for fitting the differential structure in BBCEAS spectra due to strong, narrow absorption lines that are under-resolved and hence exhibit non-Beer-Lambert law behavior at the resolution of the BBCEAS measurements. This approach is tested on BBCEAS spectra of water vapor's 4v+{delta} absorption bands around 650 nm. The most immediate analytical application of the present instrument is in quantifying the concentration of reactive trace gases in the ambient atmosphere. The instrument's detection limits for NO{sub 3} as a function of integration time are considered in detail using an Allan variance analysis. Experiments under laboratory conditions produce a 1{sigma} detection limit of 0.25 pptv for a 10 s acquisition time, which improves with further signal averaging to 0.09 pptv in 400 s. Finally, an example of the instrument's performance under field work conditions is presented, in this case of measurements of the sum of NO{sub 3}+N{sub 2}O{sub 5} concentrations in the marine boundary layer acquired during the Reactive Halogens in the Marine Boundary Layer field campaign.

36 MATERIALS SCIENCE↗

A versatile electron-ion coincidence spectrometer for photoelectron momentum imaging and threshold spectroscopy on mass selected ions using synchrotron radiation

We present a photoelectron-photoion coincidence (PEPICO) spectrometer named DELICIOUS II which combines a velocity map imaging apparatus with a Wiley-McLaren time of flight analyzer for the study of gas phase samples in interaction with the synchrotron radiation (SR). This versatile system is capable of providing photoelectron images on mass-selected compounds with kinetic energy resolutions of {delta}E/E=5% and a 17 eV bandwidth, as well as threshold photoelectron spectra with a measured resolution of 0.8 meV, as demonstrated on the 3p{sup -1} ionization of argon. This instrument is also employed for threshold PEPICO experiments, allowing the selection of the parent ion's internal state with sub-meV resolution for light masses (<40 amu) and with typically 2 meV resolution for a mass of 100 amu and with a mass resolving power above 200. The continuous operation of the extraction fields and the independence from the electron's time of flight are well adapted to the quasicontinuous multibunch mode of the SR. This, together with the high transmission of both the electron and ion detection, allows a high coincidence counting rate and facilitates the subtraction of false coincidences. We illustrate the spectrometer's coincidence principle of operation with examples from the valence photoionization of an Ar+Xe mixture and of CF{sub 4}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast optical spectrometer for the charge exchange diagnostic on RFX-mod

A new fast visible spectrometer built for the charge exchange diagnostic system of the RFX-mod Reversed Field pinch experiment is described. The optical mounting is of the Littrow type. The spectral resolution is defined by a 3000 grooves/mm, 180x143 mm{sup 2} wide reflection grating, and a focal length of 400 mm. The collimating optics is based on a commercial high quality f/2.8 telephoto lens, so that the input fibers can be vertically stacked without space in between. The detector is a two-dimensional charge coupled device back-illuminated sensor to ensure high quantum efficiency. Thus the spectrometer combines high speed, high spectral resolution, and excellent imaging quality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗