Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solvent effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Understanding Solvent-Induced Glass Transition in Polymer Thin Films Using Absorption–Desorption Isotherms

The fundamental thermodynamic and mechanical underpinnings of polymer thin films exposed to solvent vapor are critical for the development of advanced nanolithography and high-performance coatings. This work investigates the solvent− polymer interactions of glassy thin films by using the solvent absorption−desorption isotherms. An analogous relationship to the Flory−Fox equation was observed between solvent−induced glass transition, swelling, Flory−Huggins interaction parameter, and molecular weight. Isothermal swelling measurements revealed that the glass transition trends are more robust in the absorption curve compared to desorption, contrary to previous reports. Excess osmotic pressure analysis of the isotherm provides a measure of the degree of physical aging in thin films annealed below the glass transition. This is further validated in the ordering of block copolymer (BCP) films annealed at low solvent activity. In agreement with the thermal analysis, free-surface plasticization effects become the most prominent below 100 nm. However, solvent annealing is largely dependent on solvent mass transport, as made evident by the strong dependence on solvent viscosity. From these observations, four general types of isotherms are identified that graphically capture distinct solvent−polymer interaction regimes. More broadly, these results inform solvent vapor annealing-induced self-assembly, sequential infiltration synthesis, membrane-based separations, adsorptive processes, and swelling-based responsive materials design.

Hendeniya, Nayanathara [Iowa State Univ., Ames, IA↗

Highly Stable and Conductive 1,3‐Dioxolane/Hydrocarbon Based Electrolyte Solvent for Advanced Lithium‐Sulfur Batteries

Abstract Developing effective electrolytes is crucial for boosting the performance of Lithium‐Sulfur (LiS) rechargeable battery. Recent improvements in electrolyte formulations have enhanced cyclability by increasing electrochemical stability at the electrode interfaces. However, achieving both high ionic conductivity (σ) and stability at these interfaces simultaneously remains a significant challenge. In this study, we utilized a strategy to suppress polysulfide dissolution by employing a mixture of 1,3‐dioxolane (DOL) and hydrocarbon solvents with lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) electrolyte salt. Compared to the conventional electrolyte solution, which is 1 M LiTFSI salt in a 50/50 vol % mixture of DOL and dimethoxy ethane (DME), the LiTFSI electrolyte with DOL/hydrocarbon solvents demonstrate better cycling stability, compatibility with the Li‐metal anode, and a high specific discharge capacity (Csp). Among the various DOL/hydrocarbon and LiTFSI electrolyte salts, the combination of DOL and n‐hexane, a linear hydrocarbon, with LiTFSI electrolyte salt, (DnH40LiTFSI) exhibits remarkable σ (6.5×10 −3 S/cm at 30 °C), compatibility with the Li‐metal anode, an initial Csp of ca. 1264 mAh/g, cycling stability (Csp and Coulombic efficiency are 811 mAh/g and 98.09 % after 120 cycles) at 0.1 C by forming a good protective layer on the Li‐metal surface and preventing polysulfide dissolution.

Ahmed, Faiz↗

Innovative Approach to Recycle Lithium‐Ion Battery Electrolytes via Sequential Chemical Processes

The rapid growth of electric vehicles (EV) has driven the widespread use of lithium-ion batteries (LIBs). This will result in a large amount of spent batteries that if not properly disposed will pose significant environmental damage, especially from the electrolyte. The electrolyte contains lithium hexafluorophosphate (LiPF 6 ), which when treated by either incineration or water washing can generate harmful F- and P-containing substances such as hydrofluoric acid (HF). In this study, an innovative two-step process is presented to separate and purify both the solvents and lithium salts from the spent electrolyte. Antisolvent assisted precipitation is used to selectively isolate LiPF 6 salt in the form of a complex with ethylene carbonate. Subsequent distillation then separates the volatile electrolyte solvents and antisolvent from each other effectively. In addition, a new process to further purify LiPF 6 from its ethylene carbonate (EC) complex is also presented. This electrolyte recycling method not only enables the recovery of the high-value LiPF 6 salt and the electrolyte solvents, but also paves the way for environmentally responsible and circular LIB recycling.

electrolyte↗

Lab-scaled performance evaluation of novel water-lean solvents for post combustion CO 2 capture

Here, this work focuses on demonstrating the energetic performance and operational reliability in a continuous system of RTI's water-lean solvents for post-combustion CO 2 capture applications. RTI's Non-Aqueous Solvent, NAS-1A was subjected to 100 h of continuous, CO 2 capture and regeneration operation using a Lab-scale Gas Absorption System (LsGAS) while the CO 2 capture efficiency, mass balance, and total energy inputs were monitored. Throughout the test period, NAS-1A demonstrated stable operation with 90% CO 2 capture while requiring about 15% lower total energy input for solvent regeneration compared to 30 wt% monoethanolamine (MEA) solution. The use of a slipstream of CO 2 -rich solvent from the absorber sump reduced the regenerated CO 2 temperature before the gas was further cooled by the overhead condenser at the top of the desorber. The rich-split setup combined with a wash section may be an effective approach to remove water and solvent vapor from the regenerated CO 2 as well as to recover heat at the top of the desorber. NAS-1B was later developed and included a modifier component that lowers the heat of CO 2 absorption and reduces the vapor pressure of the amine component. The total energy inputs for 90% CO 2 capture with NAS-1B was found to be 25% less than that of the MEA. A gas chromatograph was used to monitor the amine concentration in the gas leaving the absorber wash section. It was found that under similar operating conditions, the presence of the modifier in NAS-1B reduces the amine in the absorber off-gas from 143 ppm in NAS-1A to 20 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of the Dielectric Constant on the Ionic Current Rectification of Bipolar Nanopores

In this paper, we investigate how the dielectric constant, ϵ, of an electrolyte solvent influences the current rectification characteristics of bipolar nanopores. It is well recognized that bipolar nanopores with two oppositely charged regions rectify current when exposed to an alternating electric potential difference. Here, we consider dilute electrolytes with NaCl only and with a mixture of NaCl and charged nanoparticles. These systems are studied using two levels of description, all-atom explicit water molecular dynamics (MD) simulations and coarse-grained implicit solvent MD simulations. The charge density and electric potential profiles and current-voltage relationship predicted by the implicit solvent simulations with ϵ = 11.3 show good agreement with the predictions from the explicit water simulations. Under nonequilibrium conditions, the predictions of the implicit solvent simulations with a dielectric constant closer to the one of bulk water are significantly different from the predictions obtained with the explicit water model. Further, these findings are closely aligned with experimental data on the dielectric constant of water when confined to nanometric spaces, which suggests that ϵ decreases significantly compared to its value in the bulk. Moreover, the largest electric current rectification is observed in systems containing nanoparticles when ϵ = 78.8. Using enhanced sampling, we have shown that this larger rectification arises from the presence of a significantly deeper minimum in the free energy of the system with a larger ϵ, and when a negative voltage bias is applied. Since implicit solvent models and mean-field continuum theories are often used to design Janus membranes based on bipolar nanopores, this work highlights the importance of properly accounting for the effects of confinement on the dielectric constant of the electrolyte solvent. The results presented here indicate that the dielectric constant in implicit solvent simulations may be used as an adjustable parameter to approximately account for the effects of nanometric confinement on aqueous electrolyte solvents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermodynamic Water Activity Explains the Unusual Electrochemical Stability of Aqueous Deep Eutectic Solvents

The presence of water in nonaqueous deep eutectic solvent (DES) electrolytes has been debated in recent years, with efforts ranging from its complete removal to willful addition. It was shown that controlled amounts of water can be beneficial, as it not only enhances the physicochemical properties of these electrolytes but also has no significant detrimental effects on their electrochemical stability. Despite these advantages, there is still limited understanding of how water interacts with DES systems at the molecular level. This study examines the water activity in ethylene glycol and glycerol, as well as their binary mixtures with choline chloride to form the DESs ethaline and glyceline, respectively. In this work, we show that the high electrochemical stability of glyceline is related to its lower water activity compared to ethaline and can be attributed to the robust H-bonding network formed by the three hydroxyl groups of glycerol. Its 3D H-bond network effectively integrates water molecules within its solvent structure, reducing degradation and maintaining stability at higher water contents. The deviations from the ideal Raoult's law behavior are reflected in the water activity and activity coefficients, which highlight the intricate H-bond interactions within DES-water mixtures. Water acts like a lubricant within the more viscous DES mixtures without being detrimental to their electrochemical performance. The presented results emphasize the necessity of customizing DES-water compositions to enhance their performance as electrolytes, especially in flow battery applications where electrochemical stability, ionic conductivity, and fluidity are of utmost importance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sample Preparation Method for Low-Level Total 129 I Measurements by ICP-MS

Trace-level measurements of iodine’s isotopic ( 129 I and 127 I) and chemical species distributions are needed for an accurate understanding of radioiodine migration in the Hanford subsurface. Pacific Northwest National Laboratory (PNNL) previously developed a novel analytical method for iodine characterization that uses ion chromatography (IC) coupled to inductively coupled mass spectrometry (ICP-MS). While the method can measure speciated forms of 129 I at levels below the drinking water standard, an interference from molybdenum (Mo) prevents the assay from quantifying the $\underline{total}$ 129 I concentration in many Hanford sample matrices. In this work, solvent extraction was evaluated as a sample preparation method for eliminating the Mo interference. A series of 10 experiments was conducted in which solutions containing known amounts of iodate or iodide were treated by solvent extraction, and the extracted solutions were analyzed for total iodine concentrations by ICP MS. Several extraction parameters such as reagent concentrations and chemical reaction times were systematically adjusted in attempts to optimize the extraction process. While solvent extraction was shown to be effective at removing Mo, there was a consistent inability to recover more than approximately 75% of the total iodine in most experiments. This would reduce the ability to detect 129 I at levels near the drinking water standard. Additionally, the extraction efficiencies in several experiments were highly variable, suggesting that solvent extraction could add significant uncertainty to radioiodine measurements. We recommend evaluating ion exchange as an alternative sample preparation approach in fiscal year (FY) 2024.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stress- and interface-compatible red phosphorus anode for high-energy and durable sodium-ion batteries

Sodium-ion battery is a promising candidate for energy storage application, but the absence of high-capacity and low-cost anode materials significantly limit their practical specific energy and cost. Red phosphorus (RP) possesses a high theoretical specific capacity but suffers from large volume change, low electronic conductivity and unstable solid-electrolyte interphase (SEI). Herein, a hierarchical micro/nanostructured antimony-doped RP/carbon anode was developed, which demonstrate extraordinary electrochemical performance with high initial Coulombic efficiency of ~90%, high areal (~1.7 mAh cm-2) capacity together with good cycle stability and rate capability. Combined experimental and computational studies consistently revealed that such a unique structural design can dramatically accommodate the mechanical stress and moreover effectively restrain the undesired decomposition of electrolyte solvents regardless of electrolytes formulation, resulting in superior structural integrity and thin/robust SEI formation during cycling. The present finding has offered an alternative strategy for stress management and interface engineering on high-capacity alloying-based anode materials.

Liu, Xiang↗

Magnetic nanoparticle‐induced sorbent regeneration for direct air capture

Direct air capture (DAC) is a promising technology for decarbonization through the removal of CO 2 from the atmosphere. In many DAC processes, the regeneration energy used to restore the capture capacity of sorbents accounts for a significant fraction of the energy required by the whole process. Here we report an effective and scalable sorbent regeneration method for liquid DAC solvents based on magnetic nanoparticles (MNPs) heating with AC magnetic fields. MNPs can be directly heated to provide uniform and rapid volumetric heating, as we demonstrate by promoting the release of captured CO 2 from an aqueous solution of potassium sarcosinate. Our results showed that 90% of the solvent can be regenerated within 7.5 min of heating through proposed technique. The MNPs and solvent are found to be stable during the regeneration process and the MNPs showed long-term stability in the CO 2 -saturated solvent. Cyclic experiments showed that the nanoparticles can be reused for multiple cycles without performance deterioration. The process is operated in a noncontact mode through electromagnetic waves, making it an adoptable approach for existing carbon capture systems. The MNPs heating provides an effective regeneration strategy for liquid solvents used in carbon capture processes, in particular for DAC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Role of Cooperative Interactions Among Surfaces, Solvents, and Reactive Intermediates on Catalysis at Liquid–Solid Interfaces (Final Report DE-SC0020224)

This project established quantitative links between inner‑sphere chemistry (active metal identity, coordination, and zeolite topology) and outer‑sphere organization (solvent identity, hydrogen‑bond networks, and pore condensation) that govern rates, activation barriers, and selectivities for alkene epoxidation and epoxide ring‑opening at solid–liquid and quasi‑liquid–solid interfaces. We deconvoluted contributions from covalent interactions at active sites and noncovalent, solvent‑mediated interactions within pores by pairing well‑defined metal substituted zeolites with controlled solvent environments. We then mapped those contributions onto measurable kinetics (ΔH‡, ΔS‡), adsorption thermodynamics (ITC), and in situ spectroscopy. The transferrable outcomes include a set of design rules that include the following understandings. First, tune silanol ((SiOH)x) density and pore topology to organize solvent networks that selectively stabilize transition states. Second, exploit activity‑coefficient‑normalized rates and adsorption– barrier correlations to diagnose when solvent reorganization rather than surface chemistry limits performance. Third, use partial pore condensation (e.g., acetonitrile, water but also generalizable to other solvents) to elicit liquid‑like stabilization effects even in nominally vapor‑phase reactors. Collectively, these results provide strategies to increase epoxidation rates, improve oxidant utilization (i.e., selectivities), and steer regioselectivity in zeolite‑based catalytic processes relevant to sustainable oxidation chemistry. These outcomes should be transferable to other classes of reactions that proceed in microporous materials and under confinement provided by organized solvents (e.g., electrochemical double layers).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of Ether Solvent and Anion Coordination on Electrochemical Behavior in Calcium Battery Electrolytes

The emergence of magnesium and calcium batteries as potential beyond Li ion energy storage technologies has generated significant interest into the fundamental aspects of alkaline earth metal cation coordination in multivalent electrolytes and the impact of coordination on application-critical electrolyte properties such as solubility, transport, and electrochemical stability. Understanding these details in calcium electrolytes is of immediate importance due to recent, unprecedented demonstrations of reversible calcium metal electrodeposition in a limited number of ethereal solvent-based systems. In this work, we provide insight connecting Ca 2+ coordination tendencies to important calcium battery electrolyte properties. Our results demonstrate a clear solvent:Ca 2+ coordination strength trend across a series of cyclic ether and linear glyme solvents that controls the extent of ion association in solutions of “weakly” coordinating salts. We apply understanding gained from these results to rationalize relative anion:Ca 2+ coordination tendencies and attendant Ca 2+ coordination structures using two oxidatively stable anions of particular interest for current battery electrolytes. Armed with this understanding of solvent and anion interactions with Ca 2+ , we demonstrate and interpret differences in electrochemical calcium deposition behavior across several electrolyte exemplars with varying solvent and anion coordination strengths. Our findings demonstrate that solvents exhibiting especially strong coordination to Ca 2+ , such as triglyme, can inhibit reversible calcium deposition despite effective elimination of anion:Ca 2+ coordination while solvents exhibiting more modest coordination strength, such as 1,2-dimethoxyethane, may enable deposition provided anion:Ca 2+ coordination is substantially limited. These results reveal that the strength of coordination of both anion and solvent should be considered in the design of electrolytes for calcium batteries.

25 ENERGY STORAGE↗

Method for controlling protein crystallization

A method and apparatus for controlling the crystallization of protein by solvent evaporation including placing a drop of protein solution between and in contact with a pair of parallel plates and driving one of the plates toward and away from the other plate in a controlled manner to adjust the spacing between the plates is presented. The drop of solution forms a liquid cylinder having a height dependent upon the plate spacing thereby effecting the surface area available for solvent evaporation. When the spacing is close, evaporation is slow. Evaporation is increased by increasing the spacing between the plates until the breaking point of the liquid cylinder. One plate is mounted upon a fixed post while the other plate is carried by a receptacle movable relative to the post and driven by a belt driven screw drive. The temperature and humidity of the drop of protein solution are controlled by sealing the drop within the receptacle and mounting a heater and dessicant within the receptacle.

Noever, David A.↗

Multilevel Computational Studies Reveal the Importance of Axial Ligand for Oxygen Reduction Reaction on Fe–N–C Materials

The systematic improvement of Fe–N–C materials for fuel cell applications has proven challenging, due in part to an incomplete atomistic understanding of the oxygen reduction reaction (ORR) under electrochemical conditions. Herein, a multilevel computational approach, which combines ab initio molecular dynamics simulations and constant potential density functional theory calculations, is used to assess proton-coupled electron transfer (PCET) processes and adsorption thermodynamics of key ORR intermediates. These calculations indicate that the potential-limiting step for ORR on Fe–N–C materials is the formation of the Fe III –OOH intermediate. They also show that an active site model with a water molecule axially ligated to the iron center throughout the catalytic cycle produces results that are consistent with the experimental measurements. In particular, reliable prediction of the ORR onset potential and the Fe(III/II) redox potential associated with the conversion of Fe III –OH to Fe II and desorbed H 2 O requires an axial H 2 O co-adsorbed to the iron center. The observation of a five-coordinate rather than four-coordinate active site has significant implications for the thermodynamics and mechanism of ORR. Importantly, these findings highlight the importance of solvent–substrate interactions and surface charge effects for understanding the PCET reaction mechanisms and transition-metal redox couples under realistic electrochemical conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predicting Low Toxicity and Scalable Solvent Systems for High–Speed Roll–to–Roll Perovskite Manufacturing

Printed lead-based perovskite photovoltaics (PV) have gained interest due to their potential to be manufactured with scalable roll-to-roll techniques. In industrial scale-up, toxicity of inks can constrain roll-to-roll manufacturing due to the added cost of managing toxic effluents. Due to solvent toxicity, few perovskite solution chemistries in published works are scalable to gigawatt production capacity at low cost. Herein, it is shown that for scalable PV production, the use of aprotic polar solvents should be avoided due to their overall toxicity. Compliance with worldwide worker safety regulations for solvent exposure limits could require additional air handling requirements for some solvents, which in turn would affect cost-effectiveness. It is shown that costs associated with handling of hazardous substances can be significant and estimate an added cost of ¢3.7/W for dimethylformamide (DMF)-based inks. To solve this problem, a new perovskite ink solvent system is developed that is composed entirely of ether and alcohol, which has an effective exposure limit 14× higher than DMF, making it suitable for industrial coating processes. Here, it is shown that the new ink solvent system is capable of fabricating high-efficiency perovskite solar cells processed in 1 min on a standard roll-to-roll system.

36 MATERIALS SCIENCE↗

Life of Pennzane and 815Z-Lubricated Instrument Bearings Cleaned with Non-CFC Solvents

This report takes the form of two papers: (1) "Life of Pennzane and 815Z-Lubricated Instrument Bearings cleaned with Non-CFC Solvents" and (2) a published paper, entitled "Instrument bearing life with NON-CFC cleaners". Abstract for paper # 1 : Bearings used in spacecraft mechanisms have historically been cleaned with chlorofluorocarbon CFC-1 13 (Freon) solvents and lubricated with a perfluorinated polyalkylether (PFPE) oils like 815-Z. Little full-scale bearing life test data exists to evaluate the effects of the newer class environmental-friendly bearing cleaners or improved synthetic hydrocarbon space oils like Pennzane. To address the lack of data, a cooperative, bearing life test program was initiated between NASA, Lockheed Martin and MPB. The objective was to obtain comparative long-term, life test data for flight-quality bearings, cleaned with non-CFC solvents versus CFC-1 13 under flight-like conditions with two space oils. A goal was to gain a better understanding of the lubricant surface chemistry effects with such solvents. A second objective was to obtain well-controlled, full-scale bearing life test data with a relatively new synthetic oil (Pennzane), touted as an improvement to Bray 815Z, an oil with considerable space flight history. The second paper, which serves as an attachment, is abstracted below: Bearings used in spacecraft mechanisms have historically been cleaned with chlorofluorocarbon CFC-113 (Freon) solvents and lubricated with a perfluorinated polyalkylether (PFPE) oils like 815-Z. Little full-scale bearing life test data exists to evaluate the effects of the newer class environmental-friendly bearing cleaners or improved synthetic hydrocarbon space oils like Pennzane. To address the lack of data, a cooperative, bearing life test program was initiated between NASA, Lockheed Martin and MPB. The objective was to obtain comparative long-term, life test data for flight-quality bearings, cleaned with non-CFC solvents versus CFC-1 13 under flight-like conditions with two space oils. A goal was to gain a better understanding of the lubricant surface chemistry effects with such solvents. A second objective was to obtain well-controlled, full-scale bearing life test data with a relatively new synthetic oil (Pennzane), touted as an improvement to Bray 815Z, an oil with considerable space flight history.

Loewenthal, Stuart↗

A Membrane Contactor Enabling Energy-Efficient CO 2 Capture from Point Sources with Deep Eutectic Solvents

We demonstrate a scalable and energy-efficient hollow fiber membrane contactor (HFMC)-based process using a green solvent for CO 2 capture. This process uses a deep eutectic solvent (DES) in an HFMC to provide close interfacial interactions and contact between the DES and CO 2 . This approach overcomes disadvantages associated with direct absorption in DES and could potentially be applied to a variety of solvent-based CO 2 capture methods. Commercial low-cost polymer hollow fiber membranes (e.g., microporous polypropylene) were evaluated for CO 2 capture with reline, a prototypical DES. Single-gas measurements showed that the DES-based polypropylene HFMC can capture and separate CO 2 while rejecting N2. From a mixed gas containing 50 mol % N 2 and 50 mol % CO ν , the DES-based HFMC separated CO 2 with a purity of 96.9 mol %. The effect of several process parameters including solvent flow rate, pressure, and temperature on the CO 2 separation performance was studied. The flux of the recovered CO 2 was 67.43 mmole/m 2 /h at a feed pressure of 4 bar. In situ Fourier transform infrared (FTIR) measurements combined with density functional theory (DFT)-based molecular dynamics simulations revealed that reline absorbs CO 2 by physical absorption without forming a new chemical compound, and CO 2 separation by reline occurs via the pressure swing mechanism. This research provides fundamental insights about physical solvent-based separation processes and a pathway toward practical deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electro-reduction of organics on metal cathodes: A multiscale-modeling study of benzaldehyde on Au (111)

Here, we present a multiscale modeling study on the electro-reduction of benzaldehyde (BZY) on Au(111) under realistic electrochemical conditions. To model the electrochemical cell, we adopt a capacitor model in which complex solvents are confined between a Au cathode and a carbon anode. Classical molecular dynamics simulations reveal that electrode charge density and the presence of alcohol show strong effects on the density, adsorption geometry and dynamics of benzaldehyde on the Au electrode. Under charging conditions, the surface concentration of benzaldehyde on the Au electrode decreases, while the content of other species increases. Finally, we proposed a scheme that correlates the electric current running through the Au/solvent interface with the applied bias. This study provides a molecular level understanding of how solvent composition, in this case water/alcohol content, controls the activity of electrocatalytic hydrogenation

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗