Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Single Event Effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Impact of time and space evolution of ion tracks in nonvolatile memory cells approaching nanoscale

Swift heavy ions impacting on matter lose energy through the creation of dense tracks of charges. The study of the space and time evolution of energy exchange allows understanding the single event effects behavior in advanced microelectronic devices. In particular, the shrinking of minimum feature size of most advanced memory devices makes them very interesting test vehicles to study these effects since the device and the track dimensions are comparable; hence, measured effects are directly correlated with the time and space evolution of the energy release. In this work we are studying the time and space evolution of ion tracks by using advanced non volatile memories and Monte Carlo simulations. Experimental results are very well explained by the theoretical calculations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlation of the ionisation response at selected points of IC sensitive regions with SEE sensitivity parameters under pulsed laser irradiation

The statistics of the ionisation response amplitude measured at selected points and their surroundings within sensitive regions of integrated circuits (ICs) under focused femtosecond laser irradiation is obtained for samples chosen from large batches of two types of ICs. A correlation between these data and the results of full-chip scanning is found for each type. The criteria for express validation of IC single-event effect (SEE) hardness based on ionisation response measurements at selected points are discussed. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-pixel automatic threshold calibration for the CMS Endcap Timing Layer readout chip

We present the implementation and verification of an in-pixel automatic threshold calibration circuit for the CMS Endcap Timing Layer (ETL) in the High-Luminosity LHC upgrade. The discriminator threshold of the ETL readout chip (ETROC) needs to be calibrated regularly to mitigate the circuit baseline change. Traditional methods need a lot of communication through a slow control system hence are time-consuming. This paper describes an in-pixel automatic scheme with improvements in operating time and usability. In this scheme, a sample-accumulation circuit is used to measure the average discriminator output. A binary successive approximation and linear combination scan are applied to find the equivalent baseline. The actual calibration procedure has been first implemented in FPGA firmware and tested with the ETROC front-end prototype chip (ETROC0). The calibration circuit has been implemented with Triple Modular Redundancy (TMR) and verified with Single Event Effects (SEEs) simulation. A complete calibration process lasts 35 ms with a 40 MHz clock. In the worst case, the dynamic and static power consumption are estimated to be 300 uW and 10.4 uW, respectively. The circuit design, implemented in a 65 CMOS technology, will be integrated into ETROC2, the next iteration of the ETROC with a 16 x16 pixel matrix.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First test results of the HGCAL concentrator ASICs: ECON-T and ECON-D

With over 6 million channels, the High Granularity Calorimeter for the CMS HL-LHC upgrade presents a unique data transmission challenge. The ECON ASICs provide a critical stage of on-detector data compression and selection for the trigger path (ECON-T) and data acquisition path (ECON-D) of the HGCAL. The ASICs, fabricated in 65 nm CMOS, are radiation tolerant up to 200 Mrad and require low power consumption: < 2.5 mW/sensor-channel per chip. Here, we report on the first functionality and radiation tests for the ECON-D-P1 full-functionality prototype. We present a comparison of single event effect (SEE) cross sections measured for different methods of triple modular redundancy using test results from the ECON-T-P1 full-functionality prototype.

47 OTHER INSTRUMENTATION↗

Robust Duplication with Comparison Methods in Microcontrollers

Commercial microprocessors could be useful computational platforms in space systems, as long as the risk is bound. Many spacecraft are computationally constrained because all of the computation is done on a single radiation-hardened microprocessor. It is possible that a commercial microprocessor could be used for configuration, monitoring and background tasks that are not mission critical. Most commercial microprocessors are affected by radiation, including single-event effects (SEEs) that could be destructive to the component or corrupt the data. Part screening can help designers avoid components with destructive failure modes, and mitigation can suppress data corruption. We have been experimenting with a method for masking radiation-induced faults through the software executing on the microprocessor. While triple-modular redundancy (TMR) techniques are very effective at masking faults in software, the increased amount of execution time to complete the computation is not desirable. Here in this article we present a technique for combining duplication with compare (DWC) with TMR that decreases observable errors by as much as 145 times with only a 2.35 time decrease in performance.

97 MATHEMATICS AND COMPUTING↗

Comparison of Sensitive Volumes Associated with Ion-and Laser-Induced Charge Collection in an Epitaxial Silicon Diode

A sensitive volume is developed using pulsed laser-induced collected charge for two bias conditions in an epitaxial silicon diode. These sensitive volumes show good agreement with experimental two photon absorption laser-induced collected charge at a variety of focal positions and pulse energies. When compared to ion-induced collected charge, the laser-based sensitive volume over predicts the experimental collected charge at low bias and agrees at high bias. Here, a sensitive volume based on ion-induced collected charge adequately describes the ion experimental results at both biases. Differences in the amount of potential modulation explain the differences between the ion-and laser-based sensitive volumes at the lower bias. Truncation of potential modulation by the highly doped substrate at the higher bias results in similar sensitive volumes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting from Heavy Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation

Heavy ion, focused x-ray, and pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. It is observed that these transient shape characteristics depend on the source (ion, x-ray, or laser), even when similar amounts of charge are generated. Finally, the observed differences are examined and explained in terms of basic charge collection mechanisms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FRIB Transition to User Operations, Power Ramp Up, and Upgrade Perspectives

After project completion on scope, on cost, and ahead of schedule, the Facility for Rare Isotope Beams began operations for scientific users in May of 2022. During the first 12 months of user operations, the FRIB accelerator complex delivered 5250 beam hours, including 1528 hours to nine science experiments conducted with primary beams of 36Ar, 48Ca, 70Zn, 82Se, 124Xe, and 198Pt at beam energies >200 MeV/u; 2724 hours for beam developments, studies, and tuning; and 998 hours to industrial users and non-scientific programs using the FRIB Single Event Effect (FSEE) beam line. The ramp-up to a beam power of 400 kW is planned over a six-year period; 1 kW was delivered for initial user runs from in 2022, and 5 kW was delivered as of February 2023. Upgrade plans include doubling the primary-beam energy to 400 MeV/nucleon for enhanced discovery potential (¿FRIB 400¿). This talk reports on FRIB status and progress since SRF2021, emphasizing lessons learned during the transition from beam commissioning to machine operations, challenges and resolutions for the power ramp-up, progress with accelerator improvements, and R&D for the energy upgrade.

43 PARTICLE ACCELERATORS↗

Neutron-Induced Failures in Semiconductor Devices [Slides]

Single Event Effects are a very significant failure mode in modern semiconductor devices that may limit their reliability. Accelerated testing is important for semiconductor industry, so considerably more work is needed in this field to mitigate the problem. Mitigation of this problem will probably come from Nuclear Scientists and Electrical Engineers working together.

42 ENGINEERING↗

Neutron-Induced Failures in Semiconductor Devices

This slide presentation explores single event effect, environmental neutron flux, system response, the Los Alamos Neutron Science Center (LANSCE) neutron testing facility, examples of SEE measurements, and recent interest in thermal neutrons.

42 ENGINEERING↗

neutron-Induced Failures in semiconductor Devices

Single Event Effects are a very significant failure mode in modern semiconductor devices that may limit their reliability. Accelerated testing is important for semiconductor industry. Considerable more work is needed in this field to mitigate the problem. Mitigation of this problem will probably come from Physicists and Electrical Engineers working together

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Annual LDRD Report (FY2019)

The performance of Nuclear Deterrence (ND) systems could be improved by adopting advanced commercial CMOS technologies. However, the radiation hardness of these ND systems must be assured. This project quantified dose rate upset thresholds, allowing us to evaluate whether advanced commercial technologies can be used in rad hard applications. This project also evaluated the susceptibility of advanced commercial technologies to neutron displacement damage and single event effects, and developed hardness assurance methods. As a result of this work, Sandia is now collaborating more closely with DoD agencies and their contractors to understand and improve the radiation hardness of advanced commercial technologies. Sandia Capabilities (SPHINX, lon Beam Lab, FPGA test capabilities) were developed and are being utilized by other programs. Staff were trained to do radiation survivability testing and developed proposals that were funded. Internal and external collaborations and partnerships were developed, including with Georgia Tech. This project received the Best Paper award at the 2019 Hardened Electronics And Radiation Technology (HEART) Conference.

36 MATERIALS SCIENCE↗

Characterization of Soft Error Rate Against Memory Elements Spacing and Clock Skew in a Logic with Triple Modular Redundancy in a 65nm Process

Single Event Effects introduce soft errors in ASICs. Design methodologies like Triple ModularRedundancy (TMR) with clock skew insertion, a system level redundancy technique is a commonpractice by designers to mitigate soft errors. However, the optimal spacing between memoryelements in a TMR in 65nm process hasn't been addressed so far. RD53SEU is a mini ASICdevelopment under the framework of the CERN RD53 collaboration to characterize the soft errorrates against the separation spacing and clock skew between memory elements in a TMR. Thisarticle describes the architecture and design aspects of the various test structures on the RD53SEUtest chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spacecraft environmental anomalies expert system

A microcomputer-based expert system is being developed at the Aerospace Corporation Space Sciences Laboratory to assist in the diagnosis of satellite anomalies caused by the space environment. The expert system is designed to address anomalies caused by surface charging, bulk charging, single event effects and total radiation dose. These effects depend on the orbit of the satellite, the local environment (which is highly variable), the satellite exposure time and the hardness of the circuits and components of the satellite. The expert system is a rule-based system that uses the Texas Instruments Personal Consultant Plus expert system shell. The completed expert system knowledge base will include 150 to 200 rules, as well as a spacecraft attributes database, an historical spacecraft anomalies database, and a space environment database which is updated in near real-time. Currently, the expert system is undergoing development and testing within the Aerospace Corporation Space Sciences Laboratory.

Koons, H. C.↗

Preliminary results from the heavy ions in space experiment

The Heavy Ions In Space (HIIS) experiment is intended to provide a deep survey of intensely ionizing particles in low earth orbit. Intensely ionizing particles produce single event effects in microelectronic components and are now recognized as the principal cause of spacecraft anomalies. These particles also make an important contribution to radiation doses. Besides the practical applications, HIIS data will be used to study several important scientific questions. By measuring heavy ions that stop in HIIS, the anomalous component of cosmic rays can be studied, evidence can be searched for of heavy ions trapped in the earth's magnetic field and by comparing HISS data with observations from outside the magnetosphere, the mean ionic charge state can be determined of solar energetic particles. HIIS will also record relativistic ultraheavy galactic cosmic rays. Their elemental composition will be measured from tin to uranium. Results are presented on the elemental resolution for stopping heavy ions and relativistic heavy ions.

Adams, J. H., Jr.↗

Update on parts SEE suspectibility from heavy ions

JPL and the Aerospace Corporation have collected a fourth set of heavy ion single event effects (SEE) test data. Trends in SEE susceptibility (including soft errors and latchup) for state-of-the-art parts are displayed. All data are conveniently divided into two tables: one for MOS devices, and one for a shorter list of recently tested bipolar devices. In addition, a new table of data for latchup tests only (invariably CMOS processes) is given.

Nichols, D. K.↗

Single event test methodology for integrated optoelectronics

A single event upset (SEU), defined as a transient or glitch on the output of a device, and its applicability to integrated optoelectronics are discussed in the context of spacecraft design and the need for more than a bit error rate viewpoint for testing and analysis. A methodology for testing integrated optoelectronic receivers and transmitters for SEUs is presented, focusing on the actual test requirements and system schemes needed for integrated optoelectronic devices. Two main causes of single event effects in the space environment, including protons and galactic cosmic rays, are considered along with ground test facilities for simulating the space environment.

Label, Kenneth A.↗

Single event phenomena: Testing and prediction

Highly integrated microelectronic devices are often used to increase the performance of satellite systems while reducing the system power dissipation, size, and weight. However, these devices are usually more susceptible to radiation than less integrated devices. In particular, the problem of sensitivity to single event upset and latchup is greatly increased as the integration level is increased. Therefore, a method for accurately evaluating the susceptibility of new devices to single event phenomena is critical to qualifying new components for use in space systems. This evaluation includes testing devices for upset or latchup and extrapolating the results of these tests to the orbital environment. Current methods for testing devices for single event effects are reviewed, and methods for upset rate prediction, including a new technique based on Monte Carlo simulation, are presented.

Kinnison, James D.↗