Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scenario planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

BayoTech Risk and Modeling Support of NM Gas Site

The BayoTech hydrogen generation system has been evaluated in terms of safety considerations at the NM Gas site. The consequence of a leak in different components in the system was evaluated in terms of plume dispersion and overpressure. Additionally, the likelihood of a leak scenario for different hydrogen components was identified. The worst-case plume dispersion cases, full-bore leaks, resulted in relatively large plumes. However, these cases were noted to be far less likely than the partial break cases that were evaluated. The partial break cases resulted in nearly negligible plume lengths. Similarly, the overpressure analysis of the full-bore break scenarios resulted in much larger overpressures than the partial break cases (which resulted in negligible overpressure at the lot line). There were several cases evaluated in the analysis that represented leak scenarios from both hydrogen and natural gas sources. Generally, the natural gas leak scenarios resulted in a smaller horizontal impact than that of hydrogen leaks. The worst-case consequence from a hydrogen leak resulted from the compressors, storage pods, or dispensing system. To consider the safety features that may isolate the leak, the consequence was evaluated at different times after the leak event to show the reduction of pressure. After 2 seconds, the plume dispersion from this event is contained within the perimeter of the site. The worst-case consequences show that the plume may disperse to adjacent facilities and to the street. When considering both likelihood and consequence, the risk may be considered low because the maximum frequency of a full-bore leak from any component within the hydrogen compound is 8.2 E-5/yr. This means that a full-bore leak is expected to occur less than once every 10,000 years. The risk can be further reduced by implementing mitigative countermeasures, such as CMU walls along the sides of the equipment compound. This would reduce the overall consequence of the worst-case dispersion scenarios (horizontal impact of plume). In terms of siting and safety analysis, the NFPA 2 code was used to provide a high-level evaluation of the current site plan. The most limiting equipment in terms of set-back distance are the compressors/storage units because of the high-pressure hydrogen. The site layout was evaluated for an acceptable location for the compression/storage unit based on NFPA 2 set-back distances. It is important to note that the NFPA 2 set-back distances consider both likelihood and consequence. This is important because the worst-case results evaluated herein also represent the least likely leak scenario. Other site-specific considerations were evaluated, including the parking shade structure with photovoltaic cells and refueling vehicles. These issues were dispositioned and determined to not present a safety risk.

08 HYDROGEN↗

Exploring sustainable electricity system development pathways in South America’s MERCOSUR sub-region

South America has abundant natural water and energy resources, and exploiting these resources to achieve a clean energy future is central to the continent’s economic and sustainable development objectives for the next several decades. Designing pathways to achieving this clean energy future requires better understanding the structural, techno-economic, and policy forces that may influence the future development of the electricity sector in the region. Here, we focus on an interconnected electricity system of five South American countries – Argentina, Brazil, Chile, Paraguay, and Uruguay – which represent major electricity generation, consumption, and trade dynamics in the region. We explore the implications of various forces that could shape the future composition of the power sector in the sub-region, including: evolving renewable energy cost and performance, natural gas prices, cross-border interconnection facilities, early retirement of installed hydropower, and different decarbonization goals. We use a model framework based on a power system planning platform (GridPath) to co-optimize investment and operations of generation, storage, and transmission facilities out to 2050. Our results in a Reference scenario indicate that the electricity system can maintain a relatively clean energy portfolio by leveraging existing hydropower capacity and integrating increasingly cost-competitive wind and solar power. However, dependence on natural gas in the region is likely to remain high. A low-carbon electricity system can cost-effectively be achieved through policy interventions (e.g., renewable portfolio standards) and by diversifying investments in wind, solar, battery storage, and some new hydropower capacity. We also find that existing hydropower is critical for maintaining reliable future grid operations. Enhanced regional electricity trade, mostly based on existing interconnection capacities with nominal investment in new transmission, can significantly benefit the clean energy transition in the region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimizing Power Line Undergrounding Decisions under Varying Wildfire Risk and Weather Scenarios

Abstract—The threat of wildfire ignitions from electric power equipment has led utilities to increasingly turn to preemptive power shutoffs, which, while effective in reducing grid-induced wildfire risk, can cause significant load loss. Undergrounding power lines is an alternative strategy for preventing grid-induced wildfires. However, undergrounding lines is costly, so an efficient undergrounding plan must balance reductions in wildfire risk and load loss with the cost of undergrounding lines. We propose a robust optimization model to identify which power lines to underground to maximize load served while limiting wildfire risk across a range of wildfire risk and weather scenarios. Since solving this problem may be computationally heavy for large power grids and many operating scenarios, we present a delayed constraint generation algorithm to iteratively add scenarios until an optimal solution is found. We evaluate the performance of this framework on the RTS-GMLC with scenarios representing a year of operating conditions and compare it with a stochastic programming formulation. Our results indicate that our undergrounding model is successful in reducing load shed and risk compared to baseline cases in which no mitigation action is taken and only power shutoffs are implemented (no undergrounding). The robust formulation also reduces more load shed than the stochastic formulation in the most extreme scenarios. Index Terms—grid resilience, optimization, transmission systems, underground power lines, wildfire risk.

Taylor, S. [Department of Electrical and Computer ↗

A workflow to assess the efficacy of brine extraction for managing injection-induced seismicity potential using data from a CO 2 injection site near Decatur, Illinois

Injection of CO 2 for storage in a geologic formation increases pore pressure and alters in situ stresses. Depending on the orientation of any existing fault and fracture planes, such as critically stressed planes, this stress alteration will modify normal stresses acting on planes and could result in frictional sliding and release stored energy in the form of seismicity. Brine extraction (BE) is a technique that can be applied prior to, or during, CO 2 injection to reduce pore pressure for increasing storage capacity and, potentially, for reducing the likelihood of frictional sliding. Here a workflow is described to assess the efficacy of BE for mitigating frictional sliding (i.e., seismicity) during injection and entails: site characterization, stress calculations and failure assessment, static and dynamic modeling, and BE operational planning. Site characterization describes the stress field used to calculate the Coulomb Failure Function (CFF) that constrains allowable pore pressure changes and injection rates in the numerical simulation of CO 2 injection scenarios. The inclusion of BE in the workflow allows for determination of the potential need for pressure reduction, and evaluation of the effectiveness of this operation. Example application of the workflow using an injection field dataset near Decatur, IL, provides insight on fracture planes and stresses at the site, formation properties and the impact of variable CO 2 injection-rate targets on whether BE plans are required. The study workflow indicates that BE could enhance CO 2 injection rate by 39% and correspondingly reduce the potential for injection-induced seismicity as indicated by a reduction in CFF.

58 GEOSCIENCES↗

Quantum Search Approaches to Sampling-Based Motion Planning

In this paper, we present a novel formulation of traditional sampling-based motion planners as database-oracle structures that can be solved via quantum search algorithms. We consider two complementary scenarios: for simpler sparse environments, we formulate the Quantum Full Path Search Algorithm (q-FPS), which creates a superposition of full random path solutions, manipulates probability amplitudes with Quantum Amplitude Amplification (QAA), and quantum measures a single obstacle free full path solution. For dense unstructured environments, we formulate the Quantum Rapidly Exploring Random Tree algorithm, q-RRT, that creates quantum superpositions of possible parent-child connections, manipulates probability amplitudes with QAA, and quantum measures a single reachable state, which is added to a tree. As performance depends on the number of oracle calls and the probability of measuring good quantum states, we quantify how these errors factor into the probabilistic completeness properties of the algorithm. We then numerically estimate the expected number of database solutions to provide an approximation of the optimal number of oracle calls in the algorithm. We compare the q-RRT algorithm with a classical implementation and verify quadratic run-time speedup in the largest connected component of a 2D dense random lattice. We conclude by evaluating a proposed approach to limit the expected number of database solutions and thus limit the optimal number of oracle calls to a given number.

97 MATHEMATICS AND COMPUTING↗

Irradiation Testing Plan for Long Term Accident Tolerant Fuels

Many potential Accident Tolerant Fuel (ATF) technologies with the potential for making substantive improvements to the performance of Light Water Reactors (LWRs) in accident scenarios will require development and qualification timelines longer than 4 years. These technologies are named “Long Term” ATF. The attached report summarizes the irradiation testing capabilities available for use in the development and qualification of these technologies and presents a nominal test sequence.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Power sector investment implications of climate impacts on renewable resources in Latin America and the Caribbean

Climate change mitigation will require substantial investments in renewables. In addition, climate change will affect future renewable supply and hence, power sector investment requirements. We study the implications of climate impacts on renewables for power sector investments under deep decarbonization using a global integrated assessment model. We focus on Latin American and Caribbean, an under-studied region but of great interest due to its strong role in international climate mitigation and vulnerability to climate change. We find that accounting for climate impacts on renewables results in significant additional investments ($12–114 billion by 2100 across Latin American countries) for a region with weak financial infrastructure. We also demonstrate that accounting for climate impacts only on hydropower—a primary focus of previous studies—significantly underestimates cumulative investments, particularly in scenarios with high intermittent renewable deployment. Our study underscores the importance of comprehensive analyses of climate impacts on renewables for improved energy planning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simulating the Autonomous Future: A Look at Virtual Vehicle Environments and How to Validate Simulation Using Public Data Sets

The rapid evolution of autonomous vehicles (AVs) has exposed the need for fast-paced development and testing processes of a variety of perception, planning, and control algorithms. To expedite development, the AV industry and researchers leverage virtual vehicle environments to simulate a range of test scenarios that may otherwise be costly or difficult to conduct on a real test track. However, the various virtual environments may have different results depending on the fidelity of various simulation features, such as vehicle dynamics, sensor simulation, and environment recreation. Herein, this tutorial article examines a proposed framework for constructing, parameterizing, and validating a virtual vehicle environment using an existing AV data set. First, an overview of several open source and commercially available simulation tools, including their associated workflows, for scene and scenario creation is presented. Next, various open AV data sets are examined to inform the data set selection for the validation framework. Then, an example workflow of recreating a real-world scene from the selected data set in a simulation tool with various emulated sensors parameterized to match the data set is demonstrated. Finally, an example AV-perception algorithm is subjected to data streams from virtual and real-world environments and suggested metrics for analyzing the results are discussed.

42 ENGINEERING↗

Multi-Unit Dwelling Plug-in EV Charging Innovation Pilots (Final Report)

Nearly one-third of residences in the U.S. are multi-unit dwellings (MUDs), e.g., apartments and condominiums, and MUDs with five or more units account for approximately 45% of rental households. While 80% of EV charging takes place at home, less than 5% of home charging takes place at MUDs. With public electric vehicle (EV) charging still underdeveloped, lack of access to reliable home charging is a major barrier to EV adoption for MUD residents. Challenges to siting electric vehicle supply equipment (EVSE) at MUDs include the high upfront cost of EVSE installation, physical and/or electrical infrastructure constraints, a lack of clear incentives for property managers to invest in installing EV charging for tenants, and a limited number of EV charging service providers that offer solutions adapted to the unique needs of MUDs. Through award DE-EE0008473 from the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE), Center for Sustainable Energy (CSE), Energetics, and Forth, along with a diverse team of partners, led a three-year project to address barriers to EV charging at MUDs by developing an online toolkit geared toward residents, homeowner associations (HOAs), and property managers. The project, referred to as Vehicle Charging Innovations – Multi-Unit Dwellings (VCI-MUD project), engaged stakeholders across the country to identify real and perceived barriers to EV charging at MUDs and explored innovative technologies that attempt to alleviate the identified barriers. Over the course of three and a half years, the project conducted 60 interviews with industry stakeholders, compiled findings in an easy-to-use toolkit, and disseminated the toolkit across national, regional, state, and local channels. Key findings and outcomes of the VCI-MUD project include: Identifying six primary barriers to the installation of EV charging at MUDs; Developing five fact sheets and eight case studies highlighting innovative charging solutions to address barriers, including real-world operational and financial data; Developing a user-friendly, online empowerment toolkit with five important points for “making your pitch” to support EV charging to assist residents, property managers, building managers, and HOAs explore options for MUD charging. The VCI-MUD online toolkit was designed with replicability in mind. It includes general tools and guides to evaluate EV charging demand, gauge readiness for EV charging installation, and develop actionable plans. The fact sheets and case studies highlight the diversity of emerging MUD EV charging solutions, featuring different geographic and structural installation scenarios and providing interested parties with a menu of options, rather than prescribing a one-size-fits-all solution. The following resources are included in the toolkit to provide MUD stakeholders with all the information needed to navigate EV charging installation at their MUD location: Empowerment Toolkit – Easy-to-read FAQ overview, stakeholder roles and responsibilities, and additional resources for MUD EV charging installations; Charging Basics – Glossary of terms and descriptions of charging features, installation and operating expenses; EV Charging Survey Templates – Resident-to-Resident, Property Manager-to-Resident and HOA-to-Resident template letters with pre-populated template questions; Technology Selection Tool – Charging barrier fact sheets and case study examples; Installation Checklist – Submittal document requirements for EVSE installations; MUD Building Self-Evaluation Survey – Self-guided evaluation of potential barriers to EV charging installation at MUD locations; Curbside Resources – Case studies and fact sheets for curbside charging options; Find a Certified Electrician – Approved list of certified EV charging installers; “Right-to-Charge” State Legal References – Legal requirements for charging equipment at MUD locations. The online toolkit was promoted extensively in the final six months of the project and will continue to be disseminated by the Clean Cities Coalitions and other partners after the end of the VCI-MUD project to encourage, support, and demonstrate viable solutions for vehicle charging infrastructure in MUDs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary Design of Engineering-Scale Salt Accident Analysis Facility to Support Molten Salt Reactor Licensing

Systems-level nuclear accident analysis codes for reactor licensing must be validated using experimental data that represent behaviors expected during actual full-scale accidents. Some behaviors may arise from coupled processes and only manifest at large scales. This report presents the preliminary design of the Salt Accident Analysis Facility (SAAF, pronounced “safe”), which is an experimental test facility to be constructed at Argonne that can be used to conduct integrated salt accident tests at an engineering scale. The measurement capabilities of the SAAF are based on previously developed methods and will provide the representative datasets that are needed to support molten salt reactor (MSR) licensing. Details of the design, the processes to be quantified, the measurement techniques for quantifying the processes, the variables that can be adjusted to simulate different accident scenarios, and operational considerations are presented herein. This report provides stakeholders the opportunity to give feedback on the test facility capabilities and planned analyses before it is constructed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LandScan Mosaic Rapid Population Update: Jamaica After Hurricane Melissa (V1)

During a natural disaster such as Hurricane Melissa, understanding where people are located is critical for situational awareness, operational planning and humanitarian support and consequence assessment. Traditional population datasets focus on mapping populations based on residential, or "business-as-usual" scenarios. However, natural disasters can create disruptions in daily routines of population in addition to the magnitude of the population displacement, depending on the type, duration, context, and location of the event. The Geospatial Science and Human Security Division at Oak Ridge National Laboratory (ORNL) produced this latest LandScan Mosaic Rapid Population Update for Jamaica following Hurricane Melissa, a category 5 hurricane that made landfall on Jamaica on October 28 2025. This Rapid Population Update captures the immediate population displacement following the hurricane using a combination of open-source building damage assessment data from Microsoft, flood exposure data from the Global Flood Monitoring service, reported population displacement information, and humanitarian shelter locations from the Jamaican Office of Disaster Preparedness and Emergency Management and the underlying LandScan Mosaic Jamaica as a base population.

97 MATHEMATICS AND COMPUTING↗

Estimating Future Surface Water Availability Through an Integrated Climate‐Hydrology‐Management Modeling Framework at a Basin Scale Under CMIP6 Scenarios

Abstract Climate change and increasing water demand due to population growth pose serious threats to surface water availability. The biggest challenge in addressing these threats is the gap between climate science and water management practices. Local water planning often lacks the integration of climate change information, especially with regard to its impacts on surface water storage and evaporation as well as the associated uncertainties. Using Texas as an example, state and regional water planning relies on the use of reservoir “Firm Yield” (FY)—an important metric that quantifies surface water availability. However, this existing planning methodology does not account for the impacts of climate change on future inflows and on reservoir evaporation. To bridge this knowledge gap, an integrated climate‐hydrology‐management (CHM) modeling framework was developed, which is generally applicable to river basins with geographical, hydrological, and water right settings similar to those in Texas. The framework leverages the advantages of two modeling approaches—the Distributed Hydrology Soil Vegetation Model (DHSVM) and Water Availability Modeling (WAM). Additionally, the Double Bias Correction Constructed Analogues method is utilized to downscale and incorporate Coupled Model Intercomparison Project Phase 6 GCMs. Finally, the DHSVM simulated naturalized streamflow and reservoir evaporation rate are input to WAM to simulate reservoir FY. A new term—“Ratio of Firm Yield” (RFY)—is created to compare how much FY changes under different climate scenarios. The results indicate that climate change has a significant impact on surface water availability by increasing reservoir evaporation, altering the seasonal pattern of naturalized streamflow, and reducing FY.

54 ENVIRONMENTAL SCIENCES↗

Stochastic Models, Indices & Optimization Algorithms for Pricing & Hedging Reliability Risks in Modern Power Grids: Data Plan - Princeton

We collected and cleaned the synthetic grid data produced by NREL for the Texas and New York synthetic grids. We developed a high dimensional joint stochastic model for load at the zone level, and solar and wind power productions at the asset level, capturing the spatial and temporal dependencies between all the variables, and demonstrated how such a model could be fitted to historical data. We designed and implemented a simulation engine which can produce Monte Carlo scenarios for the hourly day-ahead values of load, and solar and wind power productions at the spatial and temporal resolutions of the historical data used to fit the model. Finally we developed an open-source Python package which can, from an input grid model, efficiently use forecasts and large numbers of Monte Carlo scenarios to provide unit commitment and economic dispatch for each of these scenarios. The high dimensional stochastic model and the subsequent Monte Carlo simulation engine were implemented in the package PGscen and the corresponding UC and ED optimization programs in the package Vatic.

14 SOLAR ENERGY↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Case Study about Energy and Cost Impacts for Different Community Scenarios Using a Community-Scale Building Energy Modeling Tool

The United States building sector consumed approximately 75% of electricity in 2019. By implementing renewable energy technologies and control strategies into buildings, future buildings will serve as energy generators as well as consumers. To accommodate this transition, communications among buildings and between buildings and the grid could provide more possibilities to optimize the energy performance of buildings. This paper develops a community-scale building energy model tool and conducts a case study adopting behind-the-meter distributed energy resources, sharing energy in different buildings, and using different electricity tariff structures. Three scenarios are studied: (1) electricity only supplied by the grid, (2) photovoltaic (PV) panels installed on and available to some but not all buildings, and (3) a connected community. To consider the impacts of locations and energy tariffs, this paper selects four cities and three electricity tariffs to evaluate the energy and cost performances of these three scenarios. The results show that the PV panels in Scenario 2 reduce 25% to 33% of the community-level electricity consumption and 20% to 30% of the community-level electricity cost compared with Scenario 1 in all studied locations and energy tariffs. By considering power management in the connected community (Scenario 3), the electricity consumption and cost can be further reduced by 6% to 7% and 5% to 11%, respectively, compared with Scenario 2.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pathways to a Sustainable Aviation Ecosystem: Aviation Energy Research and Operation Simulator (AEROSim)

The National Renewable Energy Laboratory (NREL) has developed highly accessible tools for ground vehicle modeling, making it easy to quickly compare powertrains and estimate the impact of technology improvements on fuel/energy consumption, performance, cost, and battery life. With AEROSim, NREL advanced aircraft, enabling the same level of ease and versatility in comparing aircraft designs across a range of scenarios and conditions.

advanced air mobility↗

The Lithuania 100% Renewable Energy Study - Interim Results: Electricity System Scenarios for 2030 [Slides]

Lithuania's Energy Vision aims to achieve self-sufficiency in electricity generation by 2035 and transition to 100% renewable energy as soon as possible while maintaining affordability, reliability, and energy security. The Lithuania Energy Agency (LEA) is partnering with the National Renewable Energy Laboratory (NREL) to conduct the Lithuania 100% Renewable Energy Study (Lithuania 100) to provide evidence-based analysis for development of Lithuania's National Energy Independence Strategy. The Lithuania 100 Study leverages unique tools and capabilities of NREL to provide rigorous technical analysis of clean energy policies to achieve 100% renewable energy, and assess impacts on electricity grid operations, hydrogen system development, electricity distribution networks, air quality, and human health outcomes. The study is supported by a stakeholder committee chaired by the Ministry of Energy of Lithuania and implemented by four technical working groups. This report provides highlights of key interim results from modeling of Lithuania's near-term electricity grid through the year 2030. Results show that Lithuania has sufficient renewable energy potential, flexible generation capacity, and interconnection with neighboring European Union countries to reliably meet projected 2030 electricity demand with 100% renewable energy. A range of scenarios were modeled, each of which achieves at least 100% renewable energy in electricity, on average over the year, by 2030. Potential demands for hydrogen across industrial and transportation sectors were also evaluated, as well as the cost of hydrogen produced in Lithuania by 2030.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) (Six-Month Progress Update) [Slides]

Puerto Rico has committed to meeting its electricity needs with 100% renewable energy by 2050, along with realizing interim goals of 40% by 2025, 60% by 2040, the phase-out of coal-fired generation by 2028, and a 30% improvement in energy efficiency by 2040, as established in Puerto Rico Energy Public Policy Act (Act 17). Since hurricanes Irma and Maria in September 2017, DOE and its national laboratories have provided Puerto Rico energy system stakeholders with tools, training, and modeling support to enable planning and operation of the electric power grid with more resilience against further disruptions. On February 2, 2022, DOE, FEMA, and six national laboratories launched the two-year Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) to conduct comprehensive analysis of stakeholder-driven pathways to Puerto Rico's energy future. The robust and objective energy analysis entails five activities, with an emphasis on power system reliability, resilience, and generation planning. This presentation was delivered in a public webinar on July 21, 2022, providing a high level summary of the progress in the first six months of the study, including presentation of four initial scenario definitions based on extensive stakeholder input.

14 SOLAR ENERGY↗