Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Temporal Study 2021-2022: Sample-Based Surface Water Chemistry and Organic Matter Characterization across Watersheds in the Yakima River Basin, Washington, USA (v3)

This dataset supports a broader study examining the drivers of temporal variability in sediment respiration rates in the Yakima River Basin. The dataset provides geochemistry and organic matter characterization data generated from samples collected at weekly or bi-weekly intervals at six sites across the Yakima River Basin in Washington, USA. Related sensor data will be published separately and can be used to link sediment respiration rates to biogeochemical processing rates. The data package was originally published in November 2022. It was updated in November 2023 (v2; modified files) and April 2025 (new and modified files). See the change history section in readme for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) dissolved inorganic carbon (DIC), dissolved organic carbon (DOC; reported as non-purgeable organic carbon; NPOC), total nitrogen (TN), total suspended solids (TSS), and ions; (5) averaged values from water chemistry data; (6) surface water sampling protocol; (7) sensor protocol; (8) readme; (9) methods codes; (10) international generic sample number (IGSN) mapping file; and (11) folder of high resolution characterization of organic via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). This folder contains two subfolders, one containing the .xml data files and the other containing instructions for using Formularity (https://omics.pnl.gov/software/formularity) and an R script to process the data based on the user's specific needs. All files are .csv, .pdf, .R, .ref, or .xml. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected our data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Temporal Study 2022-2024: Sample-Based Surface Water Dissolved Inorganic Carbon, Dissolved Organic Carbon, Total Nitrogen, Stable Isotopes, and Total Suspended Solids from across Multiple Watersheds in the Yakima River Basin, Washington, USA

This dataset supports a broader study examining the drivers of temporal variability in sediment respiration rates in the Yakima River Basin. The dataset provides geochemistry data generated from samples collected at bi-weekly or monthly intervals at six sites across the Yakima River Basin in Washington, USA. Sample and sensor data from previous years (2021-2022) can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1898912 and https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1892054, respectively. Related sensor data from 2022-2024 will be published separately. This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) readme; (4) field metadata; (5) dissolved inorganic carbon (DIC) and averages; (6) dissolved organic carbon (DOC; reported as non-purgeable organic carbon; NPOC) and averages; (7) total dissolved nitrogen (TN) and averages; (8) total suspended solids (TSS); (9) stable isotopes; (10) surface water sampling protocol; (11) sensor protocol; (12) methods codes; and (13) international generic sample number (IGSN) mapping file. All files are .csv or .pdf. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. For data and scripts associated with "Shifts in rain-snow partitioning drive faster water transit times in the US Pacific Northwest" (Butler et al., 2026), go to https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3025481

18-O↗

Effect of Sample Mass, Confinement, and Preheating Time on the Thermal Response of LLM‐105: Experiments and Kinetic Analysis

Various small-scale experiments were performed to provide data for developing a model to predict the thermal response of LLM-105 over a wide range of conditions. The thermal decomposition of LLM-105 was studied as a function of sample mass, confinement of volatile products, and preheating time in both isothermal and ramped heating experiments. The thermal decomposition of LLM-105 is a two-step process, as shown by the two exothermic peaks in the heat flow profiles, which were fitted to two nth-order autocatalytic reaction models with a similar activation energy of ∼289 kJ/mol. The magnitude and shape of these peaks varied with sample mass and confinement. Increasing sample mass enhanced the second exotherm with respect to the first one, while increasing the level of confinement promoted a transition from a sublimation-dominated regime towards thermal decomposition. The effect of LLM-105 particle size on the rate of weight loss was evident for open-pan experiments, where bigger particles sublimed at lower temperatures than smaller particles. Thermal response and solid residue composition of LLM-105 samples were analyzed following preheating for different durations. Longer preheating times caused a shift of the second exotherm to lower temperatures and a decrease in the reaction enthalpy, confirming that LLM-105 decay is a consecutive reaction mechanism, probably autocatalytic. In conclusion, the kinetic model derived from ramped experiments was validated against the measured LLM-105 fraction remaining and the enthalpy remaining of the solid residue as a function of preheating times and showed good agreement.

Chemistry - Chemical explosives↗

Depth profiling and standardization from the back side of a sample for accurate analyses: Emphasis on quantifying low‐fluence, shallow implants in diamond‐like carbon

Rationale Back‐side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near‐surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low‐fluence, shallow features even if matrix effects are a concern. Methods Implanted Na (<2.0 × 10 11 ions/cm 2 , peaking <50 nm) in diamond‐like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back‐side‐thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f‐GEO SIMS in depth‐profiling mode. Results Back‐side‐implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back‐side technique itself. Conclusions Combining back‐side depth profiling with back‐side‐implanted internal standards aides quantification of shallow mono‐ and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Effect of sample size on the maximum value distribution of fatigue driving forces in metals and alloys

An analytical framework is presented to predict the effects of sample size on the maximum value distribution (MVD) of the driving forces for fatigue crack formation in metals and alloys. The distribution of the maximum driving force for fatigue crack formation over the domain follows the generalized extreme value theory in the limit as the domain size increases to infinity. Here, a simulation-based analysis of microstructure influences on fatigue resistance for polycrystalline metals and alloys is very costly, and reaching those limits is intractable. This work models the MVD of Fatigue Indicator Parameters (FIPs), which serve as surrogate measures for the driving force for fatigue crack formation, at finite sample sizes prior to their convergence to a limiting extreme value distribution. Large-scale crystal plasticity finite element (CPFE) simulations of FCC Al 7075-T6 with microstructure realizations of various sizes are incorporated to calibrate and evaluate the developed framework, and a total of ∼6.5 million grains of Al 7075-T6 are examined. The calibrated analytical solution agrees well with the brute force Monte Carlo simulation results extracted from the CPFE simulations. Furthermore, the developed formulation can predict the MVD of FIPs for different sample sizes using a size-dependent parameter, and it is capable of accurately extrapolating the MVD of FIPs for much larger microstructure sample sizes than the size used for its calibration.

Crystal plasticity↗

Measured CO 2 sorption isotherms with 25 Bakken Petroleum System rock samples from the Lower and Upper Shales, Middle Bakken, and Three Forks formations

Isotherms were measured with 25 Bakken Petroleum System (BPS) rock samples using a magnetic suspension balance at reservoir conditions of 110 °C and pressures up to 345 bar. Samples from four wells represented the Middle Bakken (MB) and Three Forks (TF) production zones, and the Upper Bakken Shale (UBS) and Lower Bakken Shale (LBS) source shales. UBS and LBS CO 2 sorption capacities at 345 bar averaged 12–14 g/kg rock compared to 1.3 to 2.5 g/kg rock for MB and TF. Increasing pressure from 150 to 345 bar resulted in only small increases in CO 2 sorption for all lithofacies. For the UBS and LBS source shales, the higher average total organic carbon (TOC) values (14.7 and 11.4 wt.%) and clay values (25 and 28 wt.%) corresponded to their higher CO 2 sorption values while for the MB and TF samples, lower TOCs (0.3 and 0.5 wt.%) and clay values (8.2 and 18.2 wt.%) corresponded to lower CO 2 sorption values. Here, when all 25 samples (from all lithofacies) were evaluated as a group, sorption capacities were highly correlated with TOC (Spearman's rho values +0.84 to +0.85), with rock density (rho values -0.75 to -0.76), and clay content (rho values +0.66). However, correlations with porosity and thermal maturity (Tmax) were weak. Measured sorption capacities and rock porosities showed that sorption accounted for about 10-times as much CO 2 storage as the available pore space for the UBS and LBS lithofacies. In contrast, the pore space dominated the storage resource of the TF and MB lithofacies.

54 ENVIRONMENTAL SCIENCES↗

Design of an 8-channel 40 GS/s 20 mW/Ch waveform sampling ASIC in 65 nm CMOS

One picosecond timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in TSMC 65 nm process targetting one picosecond resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing for picosecond time resolution combined with a long effective buffer. Each fast SCA is 1.6 ns long and has a nominal sampling rate of 40 GS/s. The slow SCA is 204.8 ns long and samples at 5 GS/s. Recording of the analog data for each channel is triggered by a fast discriminator capable of multiple triggering during the window of the slow SCA. To achieve a large dynamic range, low leakage, and high bandwidth, the SCA sampling switches are implemented as 2.5 V nMOSFETs controlled by 1.2 V shift registers. Stored analog data are digitized by an external ADC at 10 bits or better. Specifications on operational parameters include a 4 GHz analog bandwidth and a dead time of 20 microseconds, corresponding to a 50 kHz readout rate, determined by the choice of the external ADC. PSEC5 has been submitted for fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A dual dynamic shutter system for accelerating ion irradiation sample throughput via lateral gas implantation gradients

Ion irradiation for material performance testing is limited due to its serial nature, which allows for only one value of the implantation (appm) versus dose (dpa) parameter space to be explored for each ion and experiment at a time. While ion irradiation can accelerate the process by up to three orders of magnitude compared to neutron irradiation experiments, the sample throughput for ion irradiation remains relatively low. To address these limitations, a novel capability has been developed at the Michigan Ion Beam Laboratory (MIBL), enabling for the creation of single- and two-dimensional lateral ion implantation gradients using recently installed motorized-controlled ion-beam shutters. This advancement can generate a wide scope of the two-dimensional (H+, He2+) implantation parameter space within a single sample. Integration of this new capability now allows for dual- and triple-ion beam experiments to be performed with full user control over not only the ion implantation depth, but also laterally across the sample by imposing ion implantation concentration gradients, thus providing researchers with a high-throughput means for material testing under various irradiation conditions. Furthermore, recent improvements in MIBL's microbeam ion-beam analysis (IBA) target station now allow for probing these concentration gradients in irradiated alloys with exceptional spatial resolution, down to 10 µm. These two approaches promise to significantly improve ion irradiation capabilities and increase the sample throughput by several orders of magnitude. The application of the shutter technique plus the subsequent microbeam characterization of the imposed implantation gradients are showcased by two proof-of-principle ion-irradiated experiments, one performed on single-crystal Si and the other on the fusion-candidate alloy F82H-IEA. These advancements mark a substantial leap in ion-beam technology, offering researchers a robust, high-throughput method to efficiently investigate candidate alloys with high technological readiness for both advanced fission and fusion reactor applications, in a time- and cost-effective manner.

36 - MATERIALS SCIENCE↗

Clean quartz matters for cosmogenic nuclide analyses: An exploration of the importance of sample purity using the CRONUS-N reference material

We report reference materials are key for assessing inter-laboratory variability and measurement quality, and for placing analytical uncertainty bounds on sample analyses. Here, we investigate four years of data resulting from repeated processing of the CRONUS-N reference material for cosmogenic 10 Be and 26 Al analyses. At University of Vermont, we prepared a CRONUS-N aliquot with most of our sample batches from 2013 to 2017; these reference material samples were then distributed to four different accelerator mass spectrometry facilities, yielding 73 10 Be analyses and 58 26 Al analyses. We determine CRONUS-N 10 Be concentrations of (2.26 ± 0.14) x 10 5 atoms g -1 (n = 73, mean, 1 SD) and 26 Al concentrations of (1.00 ± 0.08) x 10 6 atoms g -1 (n = 58, mean, 1 SD). We find a reproducibility of 6.3% for 10 Be and 7.7% for 26 Al (relative standard deviations). We also document highly variable 27 Al and Mg concentrations and a 10 Be dispersion twice as large as the mean AMS analytic uncertainty. Analyses of the CRONUS-N material with and without density separation demonstrate that non-quartz minerals are present in the material and have a large impact on measured concentrations of 27 Al, 10 Be, and impurities; these non-quartz minerals represent only a very small portion of the total mass (0.6–0.8%) but have a disproportionally large effect on the resulting data. Our results highlight the importance of completely removing all non-quartz mineral phases from samples prior to Be/Al extraction for the determination of in situ cosmogenic 10 Be and 26 Al concentrations.

58 GEOSCIENCES↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

Sub-Sampled Imaging for STEM: Maximising Image Speed, Resolution and Precision Through Reconstruction Parameter Refinement

Sub-sampling during image acquisition in scanning transmission electron microscopy (STEM) has been shown to provide a means to increase the overall speed of acquisition while at the same time providing an efficient means to control the dose, dose rate and dose overlap delivered to the sample. In this paper, we discuss specifically the parameters used to reconstruct sub-sampled images and highlight their effect on inpainting using the beta-process factor analysis (BPFA) methodology. The selection of the main control parameters can have a significant effect on the resolution, precision and sensitivity of the final inpainted images, and here we demonstrate a method by which these parameters can be optimised for any image in STEM. As part of this paper, we also provide a link to open source code and a tutorial on its use, whereby these parameters can be tested for any datasets. When coupled with the hardware necessary to rapidly sub-sample images in STEM, this approach can have significant implications for imaging beam sensitive materials and dynamic processes.

47 OTHER INSTRUMENTATION↗

Sensitive Top-Down Proteomics Analysis of a Low Number of Mammalian Cells Using a Nanodroplet Sample Processing Platform

Top-down proteomics is a powerful tool for characterizing genetic variations and post-translational modifications at intact protein level. That being said, one significant technical gap of top-down proteomics is the inability to analyze low amount of biological samples, which limits its access to isolated rare cells, fine-needle aspiration biopsies, and tissue substructures. Herein, we developed an ultrasensitive top-down platform by incorporating a microfluidic sample preparation system, termed nanoPOTS (Nanodroplet Processing in One pot for Trace Samples), into a top-down proteomics workflow. A unique combination of a nonionic detergent dodecyl-ß-D-maltopyranoside (DDM) with urea as protein extraction buffer significantly improved both protein extraction efficiency and sample recovery. We hypothesize that the DDM detergent improves protein recovery by efficiently reducing non-specific adsorption of intact proteins on container surfaces, while urea serves as a strong denaturant to disrupt noncovalent complexes and release intact proteins for downstream analysis. The nanoPOTS-based top-down platform reproducibly and quantitatively identified ~170 to ~620 proteoforms from ~70 to ~770 HeLa cells containing ~10 to ~115 ng of total protein. A variety of post-translational modifications including acetylation, myristoylation, and iron binding were identified using only less than 800 cells. We anticipate the nanoPOTS top-down proteomics platform will be broadly applicable in biomedical researches, particularly where clinical specimens are not available in amounts amenable to standard workflows.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure-Driven Liquid Microjunction Surface-Sampling Probe Mass Spectrometry

The rhizosphere is the narrow region of soil surrounding the roots of plants that is influenced by root exudates, root secretions, and associated microbial communities. This region is crucial to plant growth and development and plays a critical role in nutrient uptake, disease resistance, and soil transformation. Understanding the function of exogenous compounds in the rhizosphere starts with determining the spatiotemporal distribution of these molecular components. Using liquid microjunction surface-sampling probe mass spectrometry (LMJ-SSP-MS) and microfluidic devices with attached microporous membranes enables in situ, nondisruptive, and nondestructive spatiotemporal measurement of exogenous compounds from plant roots. However, long imaging times (>2 h) can negatively affect plant heath and limit temporal studies. Here, we present a novel strategy to optimize the number and location of sampling sites on these microporous membrane-covered microfluidic devices. In conclusion, this novel, “structure-driven” sampling workflow takes into consideration the channel structure of the microfluidic device to maximize sampling from the channels and minimize acquisition time (~4× less time in some cases while providing similar chemical image accuracy), thus reducing stress on plants during in situ LMJ-SSP-MS analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupling Microdroplet-Based Sample Preparation, Multiplexed Isobaric Labeling, and Nanoflow Peptide Fractionation for Deep Proteome Profiling of the Tissue Microenvironment

There is increasing interest in developing in-depth proteomic approaches for mapping tissue heterogeneity in a cell-type-specific manner to better understand and predict the function of complex biological systems such as human organs. Existing spatially resolved proteomics technologies cannot provide deep proteome coverage due to limited sensitivity and poor sample recovery. Herein, we seamlessly combined laser capture microdissection with a low-volume sample processing technology that includes a microfluidic device named microPOTS (microdroplet processing in one pot for trace samples), multiplexed isobaric labeling, and a nanoflow peptide fractionation approach. The integrated workflow allowed us to maximize proteome coverage of laser-isolated tissue samples containing nanogram levels of proteins. We demonstrated that the deep spatial proteomics platform can quantify more than 5000 unique proteins from a small-sized human pancreatic tissue pixel (∼60,000 μm2) and differentiate unique protein abundance patterns in pancreas. Furthermore, the use of the microPOTS chip eliminated the requirement for advanced microfabrication capabilities and specialized nanoliter liquid handling equipment, making it more accessible to proteomic laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the Effect of Sample Geometry on Temperature Distribution during Optical Floating Zone Crystal Growth in Vacuum Environment through Heat Transfer Modeling

Optical floating zone furnaces (OFZ) have had a transformative impact on fundamental science due to their ability to rapidly produce large single crystals of a wide variety of complex materials. However, a quantitative understanding of the OFZ growth environment is generally lacking due to the difficulty of measuring the local sample temperatures during OFZ growth, as well as to the general lack of information about the temperature-dependent physical parameters needed to model heat transfer. To overcome these challenges, we apply a physics-based heat transfer model, parametrized by measurements from synchrotron experiments and a machine-learning (ML) algorithm, to simulate the temperature distributions of samples heated in an OFZ furnace in a vacuum environment. This model is used to quantitatively understand how the sample maximum temperature and temperature gradient (key parameters that influence the success of crystal growth) are affected by the rod size, rod shape, and heat-zone position on the rod. The results of this study can be applied to make informed decisions on how crystal growth parameters can be tuned to modify temperature profiles and to optimize crystal growth outcomes even when data on internal sample temperature profiles (e.g., those obtained through in situ synchrotron experiments) are not accessible.

36 MATERIALS SCIENCE↗

Quasi-In-Situ Analysis of Electrode Top Atomic Layers via High-Sensitivity Low-Energy Ion Scattering and Potential-Controlled Sample Transfer

Electrocatalytic reactions involve interfacial interactions between the surfaces of electrodes and reactive species at an electrolyte interface. There are presently no universal or unambiguous methods to directly assay the active top atomic layer composition that influences the reactivity of these electrodes under relevant operating conditions. Low-energy ion scattering (LEIS) spectroscopy is a surface characterization technique that yields compositional analysis of the outermost atomic layer of a material, but it must be performed in ultrahigh vacuum (UHV). Application of LEIS measurements to electrochemical materials that are removed from ambient liquid-phase environments thus leaves an open question as to whether the surface that is transferred to UHV is truly the surface that manifested during the electrochemical reaction. Toward the goal of preserving the active surface state, we developed a sample transfer workflow for LEIS enabling air-free removal and drying of an electrode from an electrochemical cell while maintaining control of the potential using an auxiliary electrode. The potential-controlled emersion method was demonstrated to give distinct potential-dependent surface compositions for a Cu−Pd alloy relative to removal after uncontrolled return to open-circuit potential. A Cu-enriched surface was found at anodic potential and a Pd-enriched surface at cathodic potential, suggesting that the approach can be used to retain representative atomic configurations during transfer. Since adsorbates will often persist from the reaction environment, conventional sample pretreatment methods for removal, including atomic O and atomic H exposure, were also contrasted. Both methods were found to differ with results from incidental low-dose depth profiling by the LEIS primary ion source, which removes adventitious species and surface atoms during the course of repeated measurements. These depth profiles were found to be sensitive to sample history and thus qualitatively informative, despite the possible changes induced by ion damage. The results exhibit (i) the need for complete control over the polarization state of the sample at all times (no excursions to open circuit during transfer) and (ii) the utility of low-dose depth profiling to capture changes in the near-surface composition.

Alloys↗

Enhanced Sampling of Crystal Nucleation with Graph Representation Learnt Variables

In this study, we present a graph neural network-based learning approach using an autoencoder setup to derive low-dimensional variables from features observed in experimental crystal structures. These variables are then biased in enhanced sampling to observe state-to-state transitions and reliable thermodynamic weights. Our approach uses simple convolution and pooling methods. To verify the effectiveness of our protocol, we examined the nucleation of various allotropes and polymorphs of iron and glycine from their molten states. Our graph latent variables when biased in well-tempered metadynamics consistently show transitions between states and achieve accurate free energy calculations in agreement with experiments, both of which are indicators of dependable sampling. This underscores the strength and promise of our graph neural net variables for improved sampling. Furthermore, the protocol shown here should be applicable for other systems and with other sampling methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗