Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Analysis of Tank 30H (HTF-30-18-96, -97), Tank 32H (HTF-32-18-98, -99), and Tank 37H (HTF-37-18-100, -101) Samples for Support of the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator

SRNL analyzed samples from Tank 30H, Tank 32H, and Tank 37H to support the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator system. The six samples from Tanks 30H, 32H, and 37H all contain highly concentrated salt solutions with sodium concentrations ranging from 11.8 M to 15.7 M. The samples from Tank 30H show somewhat higher concentrations of the major cations and anions in the sub-surface sample than the surface sample indicating some stratification within the tank. The two Tank 32H samples show similar concentrations of the major anions and cations between the surface and sub-surface samples. The sub-surface sample from Tank 37H shows higher concentrations for most species than the surface sample indicating some stratification within this tank as well. For all six samples, the sum of the major cations versus the sum of the major anions shows a difference of <10% providing an indication of good data quality. The VDS and surface samples from Tank 30H, Tank 32H, and Tank 37H all show silicon concentrations below 30 mg/L except for the Tank 30H VDS with a concentration of 87 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-18-301- 303 (July 2018), MCU-18-357-359-360 (August 2018), and MCU-18-402-410 (September 2018) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-18-301-302-303, MCU-18- 357-359-360 and MCU-18-402-410 are reported. Most of the conclusions are based on the September SHT sample (MCU-18-402-410). Analyses of the September SHT sample (MCU-18-402-410) indicated that the Modifier (Cs-7SB) and the extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively) by 5% and 8% respectively. The suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the April 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing radioactive salt solution from May through August 2018) to 241 mg/L, well below the minimum recommended concentration (479 mg/L). The apparent “downwards” trends observed in the TiDG, MaxCalix, and Modifier measurements are consistent with the startup (or Proficiency Runs) of MCU on May 22, 2018; new levels are consistent with the concentrations observed when MCU was fully operational in 2016. This analysis confirms the Isopar™ L addition to the solvent on July 2 and August 9, 2018. This analysis also indicates the solvent did require a trim addition. Based on the current monthly sample, the concentrations of Isopar™ L, MaxCalix, and Modifier are sufficient for continuing operation but are expected to decrease with time. The TiDG concentration was below its recommended level. Periodic characterization and trimming additions to the solvent are recommended. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected a low concentration of sec-butyl phenol (SBP) at levels of a few ppm. The impurity concentration was highest in the July sample and consistently detected in the August and September samples (but always a few ppm or less). The source of this impurity is due to the degradation of the Modifier. Another impurity observed in the samples was mercury. Based on the September SHT sample, up to 17 ± 3 micrograms of mercury per mL of solvent was detected (the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10 (SB 10 was recently added to Tank 49H in March 2017). The gamma concentration (~2.3E5 dpm/mL) measured in the September SHT samples was consistent with previous values observed when MCU was fully operational (for example, between December 2016 and January 2017) and it was lower than the April SHT measurement. The “dip” in the gamma measurement for the May 2018 SHT sample was due to Isopar™ L addition to MCU during April and May 2018. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of pooling strategies of clinical COVID-19 samples for more efficient diagnostic testing

Pooling of COVID-19 clinical samples can offer significant reduction in reagents, time, and labor needed to test large numbers of clinical samples. Especially for testing asymptomatic and return-towork/ school cases, where the prevalence of COVID-19 may be relatively low, large groups of clinical samples can be classified as negative with a single test, with no need to test every sample individually. LANL has performed validation for two different pooling strategies to assess diagnostic assay sensitivity in pooled samples compared to the clinical positive sample alone. (1) Pooling study - Determine diagnostic assay sensitivity in pooled samples with ratios of 1:5, 1:10, 1:20, and 1:30 positive to negative clinical samples. (2) Reloading study - Determine diagnostic assay sensitivity in reloading of multiple clinical samples through a Qiagen column in 5x, 10, and 20x sample volumes (1 positive plus 4, 9, and 19 negative samples).

59 BASIC BIOLOGICAL SCIENCES↗

Soil Sample Plan in Support of the Site 300 Explosives Waste Treatment Facility Ecological Risk Assessment Pursuant to the Hazardous Waste Facility Permit, Part V, Special Condition #14 a-f. August 2020

The Department of Toxic Substances Control issued the Final Hazardous Waste Facility Permit to Lawrence Livermore National Laboratory, Site 300 in 2017. As part of the continual process to ensure waste treatment emissions are not impacting ecological receptors, LLNL analyzed soil samples in the vicinity of the Explosive Waste Treatment Facility (EWTF) Burn Units (i.e., Burn Cage and Burn Pan) and the Detonation Pad. Soil samples were analyzed by EPA Solid Waste 846 Methods for furans, explosives, metals, and semivolatile compounds. In all samples, furans, explosives, and semi-volatile organic compounds were not detected. Metals were detected at concentrations below background levels. This soil sample plan will sample the same four downwind areas of the Burn Units and the same downwind areas of the Detonation, as well as including four new sample locations. The four new locations will be located to the northeast and southwest of the Burn Units and Detonation (as shown in Figure 3). The constituents to be analyzed are in Tables 2 and 3. Perchlorate was not identified as a constituent of concern in the 2007 Soil Sampling Plan. However, for this plan, all soil samples will be analyzed for perchlorate. After completion of the sampling event, a soil sample report will be submitted to DTSC in accordance with requirements specified in the Hazardous Waste Facility Permit, Part V, Special Conditions 16 a-f. This proposed soil sampling plan will be fully implemented no later than one year after receiving DTSC approval, in accordance with the Hazardous Waste Facility Permit, Part V, Special Condition 15.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Tank 38H (HTF-38-23-95, -96) and Tank 43H (HTF-43-23-93, -94) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory analyzed samples from Tank 38H and Tank 43H to support Enrichment Control Program (ECP) and Corrosion Control Program (CCP). The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased significantly from the previous Tank 38H surface sample. The current Tank 38H subsurface sample shows similar Na, free hydroxide, and anions versus the previous subsurface sample. However, the 38H subsurface sample shows higher concentrations of Al, Ca, Fe, Mn, and Si vs. the previous Tank 38H subsurface sample. The current Tank 38H subsurface sample contained visible sludge solids in excess of the previous sample based on visual appearance. Weight percent solids measurements indicate presence of 3.0 ± 0.1 wt.% insoluble solids in the Tank 38H subsurface sample. The significant differences in the concentrations of major components between the Tank 38H surface and subsurface samples indicate significant stratification of solution species between these two locations within the Tank 38H. Savannah River Mission Completion (SRMC) personnel indicated that there were no tank-to-tank transfers into Tank 38H since early January 2023 and the 2H (16H) Evaporator was shut down on 3/26/2023 and has not operated since that time. There have been many pumped non-waste transfers of water from the H-Area diversion box 7 (HDB-7) sump into Tank 38 since the 3/26/2023 date.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Tank 9H Annulus Sample in Support of Residual Material Inventory Determinations

The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC) to provide sample preparation and characterization of the Tank 9H annulus sample in support of Residual Material Inventory Determinations. One Tank 9H sample in three vials [HTF-9-25-13, HTF-9-25-14 and HTF-9-25-15], with each vial containing approximately 200 mL of the Tank 9H annulus salt solution, were delivered to the SRNL Shielded Cells for sample preparation and characterizations in February 2025. The density of the “as-received” solution contained in each of the three Tank 9H annulus sample vials were determined followed by a solid-liquid separation on each one using 0.45-micron Nalgene® nylon filter membranes. The resulting filtrates were combined to form the Tank 9H annulus sample with a total volume of about 600 mL. The combined wet solid fractions, about a total of 4.8 grams of salt material, remaining on the filter membranes were air-dried in the Shielded Cells for 72 hours. The total weight of the air-dried solids was 2.1 grams. These air-dried solids were washed with deionized water (DI water) at a phase ratio of 60 mL DI water/gram of solids to recover insoluble solids, if any. No visible or measurable quantity of insoluble solids were recovered after DI water washing of the air-dried solids because the air-dried solids completely dissolved in the DI water. The solid fraction-wash water was not combined with the 600 mL of the filtrate solution, and the resulting solution was not screened or analyzed for radionuclides. Aliquot sample volumes of the undiluted Tank 9H annulus sample were sent to the SRNL analytical services groups for radionuclides, elementals, anions and total mercury analysis by various methods including radiochemical separations/counting methods, inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) and special preparations. All sample analyses were performed in triplicate. This report presents the analytical characterization results for the Tank 9H annulus sample. The results are also reported where analytical methods yielded additional analytes, other than those requested by SRMC. In the characterization of the Tank 9H annulus sample, the detection limits for all the analytes, as specified in the Technical Task Request (TTR) and Task Technical and Quality Assurance Plan (TTQAP), were met.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving Photometric Redshift Estimates with Training Sample Augmentation

Abstract Large imaging surveys will rely on photometric redshifts (photo- z 's), which are typically estimated through machine-learning methods. Currently planned spectroscopic surveys will not be deep enough to produce a representative training sample for Legacy Survey of Space and Time (LSST), so we seek methods to improve the photo- z estimates that arise from nonrepresentative training samples. Spectroscopic training samples for photo- z 's are biased toward redder, brighter galaxies, which also tend to be at lower redshift than the typical galaxy observed by LSST, leading to poor photo- z estimates with outlier fractions nearly 4 times larger than for a representative training sample. In this Letter, we apply the concept of training sample augmentation, where we augment simulated nonrepresentative training samples with simulated galaxies possessing otherwise unrepresented features. When we select simulated galaxies with ( g - z ) color, i -band magnitude, and redshift outside the range of the original training sample, we are able to reduce the outlier fraction of the photo- z estimates for simulated LSST data by nearly 50% and the normalized median absolute deviation (NMAD) by 56%. When compared to a fully representative training sample, augmentation can recover nearly 70% of the degradation in the outlier fraction and 80% of the degradation in NMAD. Training sample augmentation is a simple and effective way to improve training samples for photo- z 's without requiring additional spectroscopic samples.

Moskowitz, Irene (ORCID:0000000222068589)↗

Production rate calibration for cosmogenic 10 Be in pyroxene by applying a rapid fusion method to 10 Be-saturated samples from the Transantarctic Mountains, Antarctica

Measurements of multiple cosmogenic nuclides in a single sample are valuable for various applications of cosmogenic nuclide exposure dating and allow for correcting exposure ages for surface weathering and erosion and establishing exposure–burial history. Here we provide advances in the measurement of cosmogenic 10 Be in pyroxene and constraints on the production rate that provide new opportunities for measurements of multi-nuclide systems, such as 10 Be/ 3 He, in pyroxene-bearing samples. We extracted and measured cosmogenic 10 Be in pyroxene from two sets of Ferrar Dolerite samples collected from the Transantarctic Mountains in Antarctica. One set of samples has 10 Be concentrations close to saturation, which allows for the production rate calibration of 10 Be in pyroxene by assuming production–decay equilibrium. The other set of samples, which has a more recent exposure history, is used to determine if a rapid fusion method can be successfully applied to samples with Holocene to Last Glacial Maximum exposure ages. From measured 10 Be concentrations in the near-saturation sample set we find the production rate of 10 Be in pyroxene to be 3.74 ± 0.10 atoms g -1 yr -1 , which is consistent with 10 Be/ 3 He paired nuclide ratios from samples assumed to have simple exposure. Given the high 10 Be concentration measured in this sample set, a sample mass of ~ 0.5 g of pyroxene is sufficient for the extraction of cosmogenic 10 Be from pyroxene using a rapid fusion method. However, for the set of samples that have low 10 Be concentrations, measured concentrations were higher than expected. We attribute spuriously high 10 Be concentrations to failure in removing all meteoric 10 Be and/or a highly variable and poorly quantified procedural blank background correction.

58 GEOSCIENCES↗

Sample holder with optical features

A sample holder for holding a sample to be observed for research purposes, particularly in a transmission electron microscope (TEM), generally includes an external alignment part for directing a light beam in a predetermined beam direction, a sample holder body in optical communication with the external alignment part and a sample support member disposed at a distal end of the sample holder body opposite the external alignment part for holding a sample to be analyzed. The sample holder body defines an internal conduit for the light beam and the sample support member includes a light beam positioner for directing the light beam between the sample holder body and the sample held by the sample support member.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Portable Immunoassay Platform for Multiplexed Detection of Biotoxins in Clinical and Environmental Samples

Multiple cases of attempted bioterrorism events using biotoxins have highlighted the urgent need for tools capable of rapid screening of suspect samples in the field (e.g., mailroom and public events). We present a portable microfluidic device capable of analyzing environmental (e.g., white powder), food (e.g., milk) and clinical (e.g., blood) samples for multiplexed detection of biotoxins. The device is rapid (<15-30 min sample-to-answer), sensitive (< 0.08 pg/mL detection limit for botulinum toxin), multiplexed (up to 64 parallel assays) and capable of analyzing small volume samples (< 20 μL total sample input). The immunoassay approach (SpinDx) is based on binding of toxins in a sample to antibody-laden capture particles followed by sedimentation of particles through a density-media in a microfluidic disk and quantification using a laser-induced fluorescence detector. A direct, blinded comparison with a gold standard ELISA revealed a 5-fold more sensitive detection limit for botulinum toxin while requiring 250-fold less sample volume and a 30 minute assay time with a near unity correlation. A key advantage of the technique is its compatibility with a variety of sample matrices with no additional sample preparation required. Ultrasensitive quantification has been demonstrated from direct analysis of multiple clinical, environmental and food samples, including white powder, whole blood, saliva, salad dressing, whole milk, peanut butter, half and half, honey, and canned meat. We believe that this device can met an urgent need in screening both potentially exposed people as well as suspicious samples in mail-rooms, airports, public sporting venues and emergency rooms. The general-purpose immunodiagnostics device can also find applications in screening of infectious and systemic diseases or serve as a lab device for conducting rapid immunoassays.

Koh, Chung-Yan↗

Laser ablation sampling system and method

A method and system for sampling a solid sample material can include the step of mounting the sample material on a support. A sample surface is coated with a surface treatment composition in a dry deposition process. A solvent supply conduit for supplying solvent to the sample surface and a solvent exhaust conduit for withdrawing solvent from the sample surface can be provided. Solvent is flowed from the solvent supply conduit to the surface treatment composition and the sample surface such that the solvent contacts the surface treatment composition. A laser beam is directed from a laser source to the sample and the surface treatment composition. The laser beam will ablate the sample and the surface treatment composition in portions intersected by the laser beam. Ablated sample material enters the solvent liquid and will be transported with the solvent away from the sample surface through the solvent exhaust conduit.

Kertesz, Vilmos↗

Laser ablation sampling system and method

A method and system for sampling a solid sample material can include the step of mounting the sample material on a support. A sample surface is coated with a surface treatment composition in a dry deposition process. A solvent supply conduit for supplying solvent to the sample surface and a solvent exhaust conduit for withdrawing solvent from the sample surface can be provided. Solvent is flowed from the solvent supply conduit to the surface treatment composition and the sample surface such that the solvent contacts the surface treatment composition. A laser beam is directed from a laser source to the sample and the surface treatment composition. The laser beam will ablate the sample and the surface treatment composition in portions intersected by the laser beam. Ablated sample material enters the solvent liquid and will be transported with the solvent away from the sample surface through the solvent exhaust conduit.

Kertesz, Vilmos↗

Improved Sampling Algorithms in the Risk-Informed Safety Margin Characterization Toolkit

The RISMC approach is developing advanced set of methodologies and algorithms in order to perform Probabilistic Risk Analyses (PRAs). In contrast to classical PRA methods, which are based on Event-Tree and Fault-Tree methods, the RISMC approach largely employs system simulator codes applied to stochastic analysis tools. The basic idea is to randomly perturb (by employing sampling algorithms) timing and sequencing of events and internal parameters of the system codes (i.e., uncertain parameters) in order to estimate stochastic parameters such as core damage probability. This approach applied to complex systems such as nuclear power plants requires to perform a series of computationally expensive simulation runs given a large set of uncertain parameters. These types of analysis are affected by two issues. Firstly, the space of the possible solutions (a.k.a., the issue space or the response surface) can be sampled only very sparsely, and this precludes the ability to fully analyze the impact of uncertainties on the system dynamics. Secondly, large amounts of data are generated and tools to generate knowledge from such data sets are not yet available. This report focuses on the first issue and in particular employs novel methods that optimize the information generated by the sampling process by sampling unexplored and risk-significant regions of the issue space: adaptive (smart) sampling algorithms. They infer system response from surrogate models constructed from existing samples and predict the most relevant location of the next sample. It is therefore possible to understand features of the issue space with a small number of carefully selected samples. In this report, we will present how it is possible to perform adaptive sampling using the RISMC toolkit and highlight the advantages compared to more classical sampling approaches such Monte-Carlo. We will employ RAVEN to perform such statistical analyses using both analytical cases but also another RISMC code: RELAP-7.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Say where you sample: Increasing site selection transparency in urban ecology

Urban ecological studies have the potential to extend our understanding of socio-ecological systems beyond that of an individual city or region. Cross-comparative empirical work and synthesis are imperative to develop a general urban ecological theory. This can be achieved only if studies are replicable and generalizable. Transparency in methods reporting facilitates generalizability and replicability by documenting the decisions scientists make during the various steps of research design; this is particularly true for sampling design and selection because of their impact on both internal and external validity and the potential to unintentionally introduce bias. Three interdependent aspects of sample design are study sample selection (e.g., specific organisms, soils, or water), sample specification (measurement of specific variable of interest), and site selection (locations sampled). Of these, documentation of site selection—the where component of sample design—is underrepresented in the urban ecology literature. Using a stratified random sample of 158 papers from 12 major urban ecology journals, we investigated how researchers selected study sites in urban ecosystems and evaluated whether their site selection methods were transparent. We extracted data from these papers using a 50-question, theory-based questionnaire and a multiple-reviewer approach. Our sample represented almost 45 years of urban ecology research across 40 different countries. We found that more than 80% of the papers read were not transparent in their site selection methodology. We do not believe site selection methods are replicable for 70% of the papers read. Key weaknesses include incomplete descriptions of populations and sampling frames, urban gradients, sample selection methods, and property access. Low transparency in reporting the where methodology limits urban ecologists’ ability to assess the internal and external validity of studies’ findings and to replicate published studies; it also limits the generalizability of existing studies. The challenges of low transparency are particularly relevant in urban ecology, a field where standard protocols for site selection and delineation are still being developed. These limitations interfere with the fields’ ability to build theory and inform policy. We conclude by offering a set of recommendations to increase transparency, replicability, and generalizability.

54 ENVIRONMENTAL SCIENCES↗

Using Xe Plasma FIB for High-Quality TEM Sample Preparation

Here, a direct comparison between electron transparent transmission electron microscope (TEM) samples prepared with gallium (Ga) and xenon (Xe) focused ion beams (FIBs) is performed to determine if equivalent quality samples can be prepared with both ion species. We prepared samples using Ga FIB and Xe plasma focused ion beam (PFIB) while altering a variety of different deposition and milling parameters. The samples’ final thicknesses were evaluated using STEM-EELS $\textit{t/λ}$ data. Using the Ga FIB sample as a standard, we compared the Xe PFIB samples to the standard and to each other. We show that although the Xe PFIB sample preparation technique is quite different from the Ga FIB technique, it is possible to produce high-quality, large area TEM samples with Xe PFIB. We also describe best practices for a Xe PFIB TEM sample preparation workflow to enable consistent success for any thoughtful FIB operator. For Xe PFIB, we show that a decision must be made between the ultimate sample thickness and the size of the electron transparent region.

47 OTHER INSTRUMENTATION↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

Iterative self-organizing SCEne-LEvel sampling (ISOSCELES) for large-scale building extraction

Convolutional neural networks (CNN) provide state-of-the-art performance in many computer vision tasks, including those related to remote-sensing image analysis. Successfully training a CNN to generalize well to unseen data, however, requires training on samples that represent the full distribution of variation of both the target classes and their surrounding contexts. With remote sensing data, acquiring a sufficiently representative training set is a challenge due to both the inherent multi-modal variability of satellite or aerial imagery and the general high cost of labeling data. To address this challenge, we have developed ISOSCELES, an Iterative Self-Organizing SCEne LEvel Sampling method for hierarchical sampling of large image sets. Using affinity propagation, ISOSCELES automates the selection of highly representative training images. Compared to random sampling or using available reference data, the distribution of the training is principally data driven, reducing the chance of oversampling uninformative areas or undersampling informative ones. In comparison to manual sample selection by an analyst, ISOSCELES exploits descriptive features, spectral and/or textural, and eliminates human bias in sample selection. Using a hierarchical sampling approach, ISOSCELES can obtain a training set that reflects both between-scene variability, such as in viewing angle and time of day, and within-scene variability at the level of individual training samples. We verify the method by demonstrating its superiority to stratified random sampling in the challenging task of adapting a pre-trained model to a new image and spatial domain for country-scale building extraction. Using a pair of hand-labeled training sets comprising 1,987 sample image chips, a total of 496,000,000 individually labeled pixels, we show, across three distinct model architectures, an increase in accuracy, as measured by F1-score, of 2.2–4.2%.

42 ENGINEERING↗

Characterization Data Package for Containerized Sludge Samples Collected from Engineered Container SCS-CON-210

This data package contains the K Basin sludge characterization results obtained by Pacific Northwest National Laboratory during processing and analysis of four sludge core samples collected from Engineered Container SCS-CON-210 in 2010 as requested by CH2M Hill Plateau Remediation Company. Sample processing requirements, analytes of interest, detection limits, and quality control sample requirements are defined in the KBC-33786, Rev. 2. The core processing scope included reconstitution of a sludge core sample distributed among four to six 4-L polypropylene bottles into a single container. The reconstituted core sample was then mixed and subsampled to support a variety of characterization activities. Additional core sludge subsamples were combined to prepare a container composite. The container composite was fractionated by wet sieving through a 2,000 micron mesh and a 500-micron mesh sieve. Each sieve fraction was sampled to support a suite of analyses. The core composite analysis scope included density determination, radioisotope analysis, and metals analysis, including the Waste Isolation Pilot Plant Hazardous Waste Facility Permit metals (with the exception of mercury). The container composite analysis included most of the core composite analysis scope plus particle size distribution, particle density, rheology, and crystalline phase identification. A summary of the received samples, core sample reconstitution and subsampling activities, container composite preparation and subsampling activities, physical properties, and analytical results are presented. Supporting data and documentation are provided in the appendices. There were no cases of sample or data loss and all of the available samples and data are reported as required by the Quality Assurance Project Plan/Sampling and Analysis Plan.

core sampling↗