Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STOPPING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Drifting localization of ionization runaway: Unraveling the nature of anomalous transport in high power impulse magnetron sputtering

The plasma over the magnetron’s erosion “racetrack” is not azimuthally uniform but concentrated in distinct dense plasma zones which move in the {vector E}×{vector B} direction with about 10% of the electrons’ {vector E}×{vector B}/B{sup 2} drift velocity. The plasma zones are investigated with a gated camera working in concert with a streak camera for Al, Nb, Cu, and W targets in Ar or Kr background gas. It is found that each plasma zone has a high density edge which is the origin of a plasma-generating electron jet leaving the target zone. Each region of strong azimuthal density gradient generates an azimuthal electric field which promotes the escape of magnetized electrons and the formation of electron jets and plasma flares. The phenomena are proposed to be caused by an ionization instability where each dense plasma zone exhibits a high stopping power for drifting high energy electrons, thereby enhancing itself.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anomalous material-dependent transport of focused, laser-driven proton beams

Intense lasers can accelerate protons in sufficient numbers and energy that the resulting beam can heat materials to exotic warm (10s of eV temperature) states. Here we show with experimental data that a laser-driven proton beam focused onto a target heated it in a localized spot with size strongly dependent upon material and as small as 35 mm radius. Simulations indicate that cold stopping power values cannot model the intense proton beam transport in solid targets well enough to match the large differences observed. In the experiment a 74 J, 670 f s laser drove a focusing proton beam that transported through different thicknesses of solid Mylar, Al, Cu or Au, eventually heating a rear, thin, Au witness layer. The XUV emission seen from the rear of the Au indicated a clear dependence of proton beam transport upon atomic number, Z, of the transport layer: a larger and brighter emission spot was measured after proton transport through the lower Z foils even with equal mass density for supposed equivalent proton stopping range. Beam transport dynamics pertaining to the observed heated spot were investigated numerically with a particle-in-cell (PIC) code. In simulations protons moving through an Al transport layer result in higher Au temperature responsible for higher Au radiant emittance compared to a Cu transport case. As a result, the inferred finding that proton stopping varies with temperature in different materials, considerably changing the beam heating profile, can guide applications seeking to controllably heat targets with intense proton beams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel Large Area High Resolution Neutron Detector for the Spallation Neutron Source

Neutron scattering is a powerful technique that is critically important for materials science and structural biology applications. The knowledge gained from past developments has resulted in far-reaching advances in engineering, pharmaceutical and biotechnology industries, to name a few. New facilities for neutron generation at much higher flux, such as the SNS at Oak Ridge, TN, will greatly enhance the capabilities of neutron scattering, with benefits that extend to many fields and include, for example, development of improved drug therapies and materials that are stronger, longer-lasting, and more impact-resistant. In order to fully realize this enhanced potential, however, higher neutron rates must be met with improved detection capabilities, particularly higher count rate capability in large size detectors, while maintaining practicality. We have developed a neutron detector with the technical and economic advantages to accomplish this goal. This new detector has a large sensitive area, offers 3D spatial resolution, high sensitivity and high count rate capability, and it is economical and practical to produce. The proposed detector technology is based on B-10 thin film conversion of neutrons in long straw-like gas detectors. A stack of many such detectors, each 1 meter in length, and 4 mm in diameter, has a stopping power that exceeds that of He-3 gas, contained at practical pressures within an area detector. With simple electronic readout methods, straw detector arrays can provide spatial resolution of 4 mm FWHM or better, and since an array detector of such form consists of several thousand individual elements per square meter, count rates in a 1 m^2 detector can reach 2?10^7 cps. Moreover, each individual event can be timetagged with a time resolution of less than 0.1 ?sec, allowing accurate identification of neutron energy by time of flight. Considering basic elemental cost, this novel neutron imaging detector can be commercially produced economically, probably at a small fraction of the cost of He-3 detectors. In addition to neutron scattering science, the fully developed base technology can be used as a rugged, low-cost neutron detector in area monitoring and surveying. Radiation monitors are used in a number of other settings for occupational and environmental radiation safety. Such a detector can also be used in environmental monitoring and remote nuclear power plant monitoring. For example, the Department of Energy could use it to characterize nuclear waste dumps, coordinate clean-up efforts, and assess the radioactive contaminants in the air and water. Radiation monitors can be used to monitor the age and component breakdown of nuclear warheads and to distinguish between weapons and reactor grade plutonium. The UN's International Atomic Energy Agency (IAEA) uses radiation monitors for treaty verification, remote monitoring, and enforcing the non-proliferation of nuclear weapons. As part of treaty verification, monitors can be used to certify the contents of containers during inspections. They could be used for portal monitoring to secure border checkpoints, sea ports, air cargo centers, public parks, sporting venues, and key government buildings. Currently, only 2% of all sea cargo shipped is inspected for radiation sources. In addition, merely the presence of radiation is detected and nothing is known about the radioactive source until further testing. The utilization of radiation monitors with neutron sensitivity and capability of operation in hostile port environments would increase the capacity and effectiveness of the radioactive scanning processes.

47 OTHER INSTRUMENTATION↗

SU-D-BRC-06: Experimental and Monte Carlo Studies of Fluence Corrections for Graphite Calorimetry in Proton Therapy

Purpose: For photon and electron beams, the standard device used to measure absorbed dose is a calorimeter. Standards laboratories are currently working on the establishment of graphite calorimeters as a primary standard for proton beams. To provide a practical method for graphite calorimetry, it is necessary to convert dose to graphite to dose to water, requiring knowledge of the water-to-graphite stopping-power ratio and the fluence correction factor. This study aims to present a novel method to determine fluence corrections experimentally, and to apply this methodology to low- and high-energy proton beams. Methods: Measurements were performed in 60 MeV and 180 MeV proton beams. Experimental information was obtained from depth-dose ionization chamber measurements performed in a water phantom. This was repeated with different thicknesses of graphite plates in front of the water phantom. One distinct advantage of this method is that only ionization chamber perturbation factors for water are required. Fluence corrections were also obtained through Monte Carlo simulations for comparison with the experiments. Results: The experimental observations made in this study confirm the Monte Carlo results. Overall, fluence corrections between water and graphite increased with depth, with a maximum correction of 1% for the low-energy beam and 4% for the high-energy beam. The results also showed that a fraction of the secondary particles generated in proton therapy beams do not have enough energy to cross the ionization chamber wall; thus, their contribution is not accounted for in the measured fluence corrections. This effect shows up as a discrepancy in fluence corrections of 1% and has been confirmed by simulations of the experimental setup. Conclusion: Fluence corrections derived by experiment do not account for low-energy secondary particles that are stopped in the ion chamber wall. This work will contribute to a practical graphite calorimetry technique for determining absolute dose to water in proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

Comparing Measured (a,n) Thick Target Yields to MCNP6 using TENDL 2012 Libraries - Paper 31

MCNP6, due to the heritage of MCNPX, has always possessed the capability to transport the light ions, such as alpha particles. Two types of competing physics take place during the particle transport: atomic and nuclear physics. Charged particles lose energy to media due to Coulombic interactions. MCNP6 models Coulombic interactions through the use of the continuous slowing down approximation. Stopping powers are calculated at a variety of energies using the Bethe-Bloch formula with Sternheimer and Peierls density effect correction. For energies less than 1.31 MeV/AMU, a low-energy SPAR model is used. When the energy of the particle is high enough, there is a transition from nuclear interactions to nucleon interactions. MCNP6 possess various physics models to account for these types of intra-nuclear cascades. These models are less accurate at low energies. Even though MCNP6 will transport these light ions to low energies (i.e. less than 20 MeV), most of the available model physics in MCNP6, for nuclear interactions, has a suggested minimum energy of ∼20-200 MeV. The result of the poorer prediction at low energies causes important light ion events, such as F-19(a,n)Na-22 from U-234 decay in UF{sub 6}, to produce orders of magnitude fewer neutrons in MCNP6 than should be emitted. As with neutrons, ACE (A Compact ENDF) formatted light ion libraries have been developed from several different evaluations. These libraries possess better physics at low energies where the physics models break down. The TENDL 2012 evaluations possess alpha transport libraries, in ACE format, such that they can easily be used with codes like MCNP6 that read ACE formatted cross sections. As a result, a capability was developed for MCNP6 to read and implement these library cross sections when the light ion reached energies below the library upper energy cutoff. Perfectly modelling an experiment for benchmark comparisons to a code calculation can be tricky. For complex setups, systematic error is always possible; and usually a hefty uncertainty analysis is required to quantify just the geometry setup and material combination choices. For an (a,n) interaction, a thick target yield is defined as the amount of neutrons emitted given that the alpha ranges out in the material. For alpha transport at low energy <10 MeV, in reasonably dense materials (>1-2 g/cc), with a material dimension length larger than a few hundred microns, alpha particles will tend to completely stop and range out in the material. For Li, Be, B, C, N, O, F, Na, Mg and Al thick target yields exist in 200 keV intervals from 1 to 9.8 MeV (most of the elements do have (a,n) thresholds above 1 MeV). Because modelling a thick target yield in MCNP6 is much easier than attempting to account for the complexity of systematic error from a full out experiment, we present here comparisons of (a,n) thick target yields to those calculated in MCNP6 using the TENDL 2012 alpha library evaluations.

61 RADIATION PROTECTION AND DOSIMETRY↗

High-Z Sensitized Plastic Scintillators: A Review

The need for affordable and reliable radiation detectors has prompted significant investment in new radiation detector materials, due to concerns about national security and nuclear nonproliferation. Plastic scintillators provide an affordable approach to large volume detectors, yet their performance for high-energy gamma radiation is severely limited by the small radiation stopping power inherent to their low atomic number. Although some sensitization attempts with organometallics were made in the 1950s to 1960s, the concomitant decrease in light yield has limited the usefulness of these sensitized detectors. Recently, with new knowledge gained during the rapid development of organic optoelectronics and nanotechnology, there has been a revived interest in the field of heavy element sensitized plastic scintillators. In this paper, the recent efforts on sensitized plastic scintillators are summarized. Basic scintillator physics is first reviewed. The discussion then focuses on two major thrusts in the field: sensitization with: (1) organometallics and (2) oxide and fluoride nanoparticles. The design rationales and major results are examined in detail, with existing limitations and possible future pathways discussed. Lastly, special attention is paid to the underlying energy deposition and transfer processes, as these determine the key performance metrics such as light yield and radioluminescence decay lifetime.

36 MATERIALS SCIENCE↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Devices for Thermal Conductivity Measurements of Electroplated Bi for X-ray TES Absorbers

Electroplated bismuth (Bi) is commonly used in transition-edge sensors (TESs) for X-rays because of its high stopping power and low heat capacity (Collan in Phys Rev B 1:2888, 1970, Yan in Appl Phys Lett 111:192602, 2017). Electroplated Bi is usually grown on top of another metal that acts as seed layer, typically gold (Au), making it challenging to extrapolate its thermoelectric properties. In this work, we present four-wire resistance measurement structures that allow us to measure resistance as a function of temperature of electroplated Bi independently of Au. The results show that the thermal conductivity of the Bi at 3 K is high enough to ensure the correct thermalization of X-ray photons when used as an absorber for TESs.

Bismuth↗

Ion Tracks and Microstructures in Barium Titanate Irradiated with Swift Heavy Ions: A Combined Experimental and Computational Study

Tetragonally structured BaTiO3 single crystals were irradiated using 635 MeV 238U+ ions to fluences of 1E7, 5E10 and 1.4E12 ions/cm2 at room temperature. Subsequent sample characterizations were performed using ion channeling, x-ray diffraction (XRD), helium ion microscopy, and transmission electron microscopy. The results show that there are lattice relaxation and recovery of pre-existing defects in the irradiated samples. Various structures representing different regimes of electronic and nuclear interactions along the ion track are observed. The track on the surface has an amorphous core of up to ~10 nm in diameter, surrounded by a strained lattice structure. The core size is roughly proportional to the square root of the electronic stopping power. Satellite-like defects around the core are also present. The ring of cubic phase expected to form around the amorphous core does not appear, probably due to a reversible phase transition as confirmed by an in-situ XRD study. Modeling and simulation are also attempted to interpret the data and gain physical insights. We have developed a partial charge model for cubic BaTiO3 that reproduces its lattice constants, elastic constants, and melting temperature. Using the interatomic potential, we have performed molecular dynamics simulations of the irradiation damage in BaTiO3. The results show that an amorphous track of ~1.2 nm in radius forms under thermal energy deposition at dE(T)/dx = 5 keV/nm. At 20 keV/nm, the radius increases to ~4.5 nm with an order of magnitude increase in the number of defects. The simulation also reveals details of the bonding environments and shows that the amorphous zones produced at different dE(T)/dx values have different densities. The combined experimental and computational data suggest that there is a significant interfacial recrystallization of the as-created amorphous cores during the cooling-down stage of thermal spikes.

barium titanate↗

Electron-phonon coupling induced defect recovery and strain relaxation in Ni and equiatomic NiFe alloy

In this work, we study the effects of local heating due to electron-phonon coupling in cumulative 10 MeV Ni ion irradiation on pre-damaged pure Ni and equiatomic NiFe alloy. In particular, we estimate the defect recovery in NiFe compared to pure Ni due to the chemical disorder. Furthermore, the simulations are done using the two-temperature molecular dynamics approach that includes the electronic stopping and electron-phonon interactions. A total of 50% of the damage that consists of isolated point defects and small defect clusters is recovered in NiFe, whereas no noticeable recovery is observed in elemental Ni. We have also demonstrated strain relaxation associated with defect recombination based on the results from both simulation and X-ray diffraction measurements in NiFe. The damage recovery primarily depends on pre-existing damage level, defect configuration, ion energy (stopping powers) and electron-phonon coupling parameter of the materials of interest.

36 MATERIALS SCIENCE↗

A direct-drive exploding-pusher implosion as the first step in development of a monoenergetic charged-particle backlighting platforn at the National Ignition Facility

A thin-glass-shell, D 3 He-filled exploding-pusher inertial confinement fusion implosion at the National Ignition Facility (NIF) has been demonstrated as a proton source that serves as a promising first step toward development of a monoenergetic proton, alpha, and triton backlighting platform at the NIF. Among the key measurements, the D3He-proton emission on this experiment (shot N121128) has been well-characterized spectrally, temporally, and in terms of emission isotropy, revealing a highly monoenergetic (ΔE/E~4%) and isotropic source (~3% proton fluence variation and ~0.5% proton energy variation). On a similar shot (N130129, with D 2 fill), the DD-proton spectrum has been obtained as well, illustrating that monoenergetic protons of multiple energies may be utilized in a single experiment. In conclusion, these results, and experiments on OMEGA, point toward future steps in the development of a precision, monoenergetic proton, alpha, and triton source that can readily be implemented at the NIF for backlighting a broad range of high energy density physics (HEDP) experiments in which fields and flows are manifest, and also utilized for studies of stopping power in warm dense matter and in classical plasmas.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

In-situ luminescence monitoring of ion-induced damage evolution in SiO 2 and Al 2 O 3

Real-time, in-situ ionoluminescence measurements provide information of evolution of emission bands with ion fluence, and thereby establish a correlation between point defect kinetics and phase stability. Using fast light ions (2 MeV H and 3.5 He MeV) and medium mass-high energy ions (8 MeV O, E=0.5 MeV/amu), scintillation materials of a-SiO 2 , crystalline quartz, and Al 2 O 3 are comparatively investigated at room temperature with the aim of obtaining a further insight on the structural defects induced by ion irradiation and understand the role of electronic energy loss on the damage processes. For more energetic heavy ions, the electronic energy deposition pattern offers higher rates of excitation deeper into the material and allows to evaluate the competing mechanisms between the radiative and non-radiative de-excitation processes. Irradiations with 8 MeV O ions have been selected corresponding to the electronic stopping regime, where the electronic stopping power is dominant, and above the critical amorphization threshold for quartz. Lastly, the usefulness of IBIL and its specific capabilities as a sensitive tool to investigate the material characterization and evaluation of radiation effects are demonstrated.

36 MATERIALS SCIENCE↗

Radiation damage in cubic-stabilized zirconia

Cubic yttria-stabilized zirconia (YSZ) can be used for nuclear applications as an inert matrix for actinide immobilization or transmutation. Indeed, the large amount of native oxygen vacancies leads to a high radiation tolerance of this material owing to defect recombination occurring in the atomic displacements cascades induced by fast neutron irradiation or ion implantations, as showed by Molecular dynamics (MD) simulations. Amorphization cannot be obtained in YSZ either by nuclear-collision or electronic-excitation damage, just like in urania. A kind of polygonization structure with slightly disoriented crystalline domains is obtained in both cases. In the first steps of damage, specific isolated point defects (like F+-type color centers) and point-defect clusters are produced by nuclear collisions with charged particles or neutrons. Further increase of damage leads to dislocation-loop formation, then to collapse of the dislocation network into a polygonization structure. For swift heavy ion irradiations, a similar polygonization structure is obtained above a threshold stopping power value of about 20-30 keV nm-1.

color centers↗

Asymmetry of radiation damage properties in Al-Ti nanolayers

Molecular dynamics (MD) simulations were employed with empirical potentials to study the effects of multilayer interfaces and interface spacing in Al-Ti nanolayers. Several model interfaces derived from stacking of close-packed layers or face-centered cubic \{100\} layers were investigated. The simulations reveal significant and important asymmetries in defect production with $\sim$60\% of vacancies created in Al layers compared to Ti layers within the Al-Ti multilayer system. The asymmetry in the creation of interstitials is even more pronounced. The asymmetries cause an imbalance in the ratio of vacancies and interstitials in films of dissimilar materials leading to $>$90\% of the surviving interstitials located in the Al layers. While in the close-packed nanolayers the interstitials migrate to the atomic layers adjacent to the interface of the Al layers, in the \{100\} nanolayers the interstitials migrate to the center of the Al layers and away from the interfaces. The degree of asymmetry and defect ratio imbalance increases as the layer spacing decreases in the multilayer films. Underlying physical processes are discussed including the interfacial strain fields and the individual elemental layer stopping power in nanolayered systems. In addition, experimental work was performed on low-dose (10$^{16}$ atoms/cm$^2$) helium (He) irradiation on Al/Ti nanolayers (5 nm per film), resulting in He bubble formation $\sim$1 nm in diameter in the Ti film near the interface. The correlation between the preferential flux of displaced atoms from Ti films to Al films during the defect production that is revealed in the simulations and the morphology and location of He bubbles from the experiments is discussed.

Al-Ti interatomic potential↗

Mechanisms of ion irradiation induced ordering in amorphous TiO 2 nanotubes: Effects of ion mass and energy

Here, amorphous TiO 2 nanotubes were irradiated in-situ in a transmission electron microscope (TEM) with Kr + ions at energies of 46 keV, 150 keV, and 1 MeV and with 46 keV Xe + ions, to investigate the structural and morphological evolution of the nanotubes under irradiation. At all irradiation conditions, amorphous TiO 2 nanotubes exhibited significant morphological instability, and tended to undergo volumetric swelling with increasing ion counts, often until collapse of the original nanotube structure. Molecular dynamics (MD) simulations confirmed that irradiation-induced defects can explain the observed swelling. Structurally, nanotubes remain amorphous following all Kr + irradiation conditions, but irradiation with 46 keV Xe + leads to the formation of anatase nanocrystallites. Importantly, through systematically varying ion energy and ion species, we try to elucidate the influence of nuclear and electronic stopping power on ion irradiation induced changes. By contextualizing these results within the existing literature, we propose that the observed changes in TiO 2 nanotube morphology and structure could be due to a competition between two mechanisms: (1) disorder-induced swelling and (2) irradiation-induced amorphous-to-crystalline transformation.

36 MATERIALS SCIENCE↗

In-situ ion irradiation induced nanograin growth in a spent UO 2 fuel

This study investigates the irradiation-driven evolution of nanograins in the early-stage restructured rim region of medium burnup spent uranium dioxide (UO 2 ) fuel. Transmission electron microscopy (TEM) lamellas prepared from Belgium Reactor 3 (BR-3) fuel were subjected to in-situ 300 keV Xe ion irradiations under varying doses, fluxes, and temperatures to evaluate their effect on the evolution of the nanograins. Our results reveal that the nanograins grow during ion irradiation. Additionally, the growth is most pronounced at elevated temperatures (300 °C), moderate at room temperature, and negligible at cryogenic temperature (−223 °C). This behavior indicates that thermal activation, alongside irradiation effects, is essential to overcome grain boundary pinning by fission gas bubbles, metallic precipitates, and porosity. Furthermore, while nanograins (<200 nm) consistently coarsened under irradiation, larger grains did not undergo further restructuring, which can be attributed to the strong defect annihilation at TEM lamella surfaces combined with the limited electronic stopping power of low energy Xe ions used in this work. These findings highlight the roles of thermal spike effects, defect mobility, and impurity pinning in governing grain evolution in the rim region of spent UO 2 fuel during ion irradiation, providing key insights for predictive models of restructuring and performance of the high burnup nuclear fuel.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Proton Range Uncertainty Due to Bone Cement Injected Into the Vertebra in Radiation Therapy Planning

We wanted to evaluate the influence of bone cement on the proton range and to derive a conversion factor predicting the range shift by correcting distorted computed tomography (CT) data as a reference to determine whether the correction is needed. Two CT datasets were obtained with and without a bone cement disk placed in a water phantom. Treatment planning was performed on a set of uncorrected CT images with the bone cement disk, and the verification plan was applied to the same set of CT images with an effective CT number for the bone cement disk. The effective CT number was determined by measuring the actual proton range with the bone cement disk. The effects of CT number, thicknesses, and position of bone cement on the proton range were evaluated in the treatment planning system (TPS) to draw a conversion factor predicting the range shift by correcting the CT number of bone cement. The effective CT number of bone cement was 260 Hounsfield units (HU). The calculated proton range for native CT data was significantly shorter than the measured proton range. However, the calculated range for the corrected CT data with the effective CT number coincided exactly with the measured range. The conversion factor was 209.6 [HU . cm/mm] for bone cement and predicted the range shift by approximately correcting the CT number. We found that the heterogeneity of bone cement could cause incorrect proton ranges in treatment plans using CT images. With an effective CT number of bone cement derived from the proton range and relative stopping power, a more actual proton range could be calculated in the TPS. The conversion factor could predict the necessity for CT data correction with sufficient accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

A LYSO crystal array readout by silicon photomultipliers as compact detector for space applications

Precise measurements of GeV range gamma rays help narrow down among var- ious gamma emission models and increase sensitivity for dark matter searches. Construction of precise as well as compact instruments requires detectors with high efficiency, high stopping power, excellent energy resolution, and excellent angular resolution. Fast and bright crystal scintillators coupled with small foot- print photo-detectors are suitable candidates. We prototyped a detector array consisting of four LYSO crystals where each crystal is read out by a 2x2 SensL ArrayJ60035 silicon photomultipliers. The LYSO crystals were chosen because of their good light yield, fast decay time, demonstrated radiation hardness, and small radiation length. Here, we used the silicon photomultiplier arrays as photo- detectors because of their small size, simple readout, low voltage operation, and immunity to magnetic elds. We also studied the detector performance in the energy range of interest by exposing it to 2-16 GeV particles produced at the Test Beam Facility of Fermi National Accelerator Laboratory.

43 PARTICLE ACCELERATORS↗