Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SRS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The Role of Palliative Radiosurgery When Cancer Invades the Cavernous Sinus

Purpose: Involvement of the cavernous sinus by direct invasion from skull base cancer or from metastatic spread of cancers is a challenging problem. We evaluated the role of stereotactic radiosurgery (SRS) in the treatment of patients who developed cavernous sinus metastases or direct invasion. Methods and Materials: We retrospectively reviewed the data from 37 patients who had cavernous sinus metastases or had cavernous sinus invasion from adjacent skull base cancers and who underwent SRS between 1992 and 2006 at University of Pittsburgh Medical Center. The median patient age was 57.8 years. Previous adjuvant management included fractionated radiotherapy in 8, chemotherapy in 16, and both radiotherapy and chemotherapy in 5. The primary sites of metastases or invasion were nasopharyngeal carcinoma (n = 7), parotid gland carcinoma (n = 7), and metastases from systemic cancer (n = 23). The median target volume was 6.3 cm{sup 3} (range, 0.3-33.6), and the median margin dose was 14 Gy (range, 12-20). Results: At a mean of 12.9 months (range, 0.8-63.9), 32 patients had died and 5 were living. The overall survival rate after SRS was 36.6% and 19.4% at 1 and 2 years, respectively. Progression-free survival was related to a greater marginal dose. After SRS, 12 (35.3%) of 34 patients with neurologic symptoms exhibited improvement. SRS early after diagnosis was significantly associated with improvement of cranial nerve dysfunction. Conclusion: SRS is a minimally invasive palliative option for patients whose cancer has invaded the cavernous sinus. The benefits for cranial nerve deficits are best when SRS is performed early.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Experiences With Onboard Imager KV Images for Linear Accelerator-Based Stereotactic Radiosurgery and Radiotherapy Setup

Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS patients and on a weekly basis for 6 SRT patients to assess any intrafraction changes. Results: For SRS patients, 57 pretreatment kV images were evaluated and the suggested shifts were all within 1 mm in any direction (i.e., within the accuracy of image fusion). For SRT patients, the suggested shifts were out of the 3-mm tolerance for 31 of 309 setups. Intrafraction motions were detected in 3 SRT patients. Conclusions: kV imaging provided a useful tool for SRS or SRT setups. For SRS setup with head frame, it provides radiographic confirmation of localization using the stereotactic target positioner. For SRT with mask, a 3-mm margin is adequate and feasible for routine setup when TaPo is combined with kV imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fractionated Stereotactic Radiosurgery for Reirradiation of Head-and-Neck Cancer

Purpose: Stereotactic radiosurgery (SRS) is an appealing treatment option after previous radiotherapy because of its precision, conformality, and reduced treatment duration. We report our experience with reirradiation using fractionated SRS for head-and-neck cancer. Methods and Materials: From 2002 to 2008, 65 patients received SRS to the oropharynx (n = 13), hypopharynx (n = 8), nasopharynx (n = 7), paranasal sinus (n = 7), neck (n = 7), and other sites (n = 23). Thirty-eight patients were treated definitively and 27 patients with metastatic disease and/or untreated local disease were treated palliatively. Nine patients underwent complete macroscopic resection before SRS. Thirty-three patients received concurrent chemoradiation. The median initial radiation dose was 67 Gy, and the median reirradiation SRS dose was 30 Gy (21-35 Gy) in 2-5 fractions. Results: Median follow-up for surviving patients was 16 months. Fifty-six patients were evaluable for response: 30 (54%) had complete, 15 (27%) had partial, and 11 (20%) had no response. Median overall survival (OS) for all patients was 12 months. For definitively treated patients, the 2-year OS and locoregional control (LRC) rates were 41% and 30%, respectively. Multivariate analysis demonstrated that higher total dose, surgical resection, and nasopharynx site were significantly associated with improved LRC; surgical resection and nonsquamous histology were associated with improved OS. Seven patients (11%) experienced severe reirradiation-related toxicity, including one treatment-attributed death. Conclusion: SRS reirradiation for head-and-neck cancer is feasible. This study demonstrates encouraging response rates with acceptable toxicity. Fractionated SRS reirradiation with concurrent chemotherapy in select patients warrants further study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single Fraction Versus Fractionated Linac-Based Stereotactic Radiotherapy for Vestibular Schwannoma: A Single-Institution Experience

Purpose: To evaluate and compare outcomes for patients with vestibular schwannoma (VS) treated in a single institution with linac-based stereotactic radiosurgery (SRS) or by fractionated stereotactic radiotherapy (SRT). Methods and Materials: One hundred and nineteen patients (SRS = 78, SRT = 41) were treated. For both SRS and SRT, beam shaping is performed by a mini-multileaf collimator. For SRS, a median single dose of 12.5 Gy (range, 11-14 Gy), prescribed to the 80% isodose line encompassing the target, was applied. Of the 42 SRT treatments, 32 treatments consisted of 10 fractions of 3-4 Gy, and 10 patients received 25 sessions of 2 Gy, prescribed to the 100% with the 95% isodose line encompassing the planning target volume. Mean largest tumor diameter was 16.6 mm in the SRS and 24.6 mm in the SRT group. Local tumor control, cranial nerve toxicity, and preservation of useful hearing were recorded. Any new treatment-induced cranial nerve neuropathy was scored as a complication. Results: Median follow-up was 62 months (range, 6-136 months), 5 patients progressed, resulting in an overall 5-year local tumor control of 95%. The overall 5-year facial nerve preservation probability was 88% and facial nerve neuropathy was statistically significantly higher after SRS, after prior surgery, for larger tumors, and in Koos Grade {>=}3. The overall 5-year trigeminal nerve preservation probability was 96%, not significantly influenced by any of the risk factors. The overall 4-year probability of preservation of useful hearing (Gardner-Robertson score 1 or 2) was 68%, not significantly different between SRS or SRT (59% vs. 82%, p = 0.089, log rank). Conclusion: Linac-based RT results in good local control and acceptable clinical outcome in small to medium-sized vestibular schwannomas (VSs). Radiosurgery for large VSs (Koos Grade {>=}3) remains a challenge because of increased facial nerve neuropathy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Survival in Contemporary Practice After Initial Radiosurgery for Brain Metastases

Purpose: The number of brain metastases (BM) is a major consideration in determining patient eligibility for stereotactic radiosurgery (SRS), but the evidence for this popular practice is equivocal. The purpose of this study was to determine whether, following multivariate adjustment, the number and volume of BM held prognostic significance in a cohort of patients initially treated with SRS alone. Methods and Materials: A total of 251 patients with primary malignancies, including non-small cell lung cancer (34%), melanoma (30%), and breast carcinoma (16%), underwent SRS for initial treatment of BM. SRS was used as the sole management (62% of patients) or was combined with salvage treatment with SRS (22%), whole-brain radiation therapy (WBRT; 13%), or resection (3%). Median follow-up time was 9.4 months. Survival was determined using the Kaplan-Meier method. Cox regression was used to assess the effects of patient factors on distant brain failure (DBF), local control (LC), and overall survival (OS). Results: LC at 1 year was 94.6%, and median time to DBF was 10 months. Median OS was 11.1 months. On multivariate analysis, statistically significant predictors of OS were presence of extracranial disease (hazard ratio [HR], 4.2, P<.001), total tumor volume greater than 2 cm{sup 3} (HR, 1.98; P<.001), age ≥60 years (HR, 1.67; P=.002), and diagnosis-specific graded prognostic assessment (HR, 0.71; P<.001). The presence of extracranial disease was a statistically significant predictor of DBF (HR, 2.15), and tumor volume was predictive of LC (HR, 4.56 for total volume >2 cm{sup 3}). The number of BM was not predictive of DBF, LC, or OS. Conclusions: The number of BM is not a strong predictor for clinical outcomes following initial SRS for newly diagnosed BM. Other factors including total treatment volume and systemic disease status are better determinants of outcome and may facilitate appropriate use of SRS or WBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes and Toxicity for Hypofractionated and Single-Fraction Image-Guided Stereotactic Radiosurgery for Sarcomas Metastasizing to the Spine

Purpose: Conventional radiation treatment (20-40 Gy in 5-20 fractions, 2-5 Gy per fraction) for sarcoma metastatic to the spine provides subtherapeutic doses, resulting in poor durable local control (LC) (50%-77% at 1 year). Hypofractionated (HF) and/or single-fraction (SF) image-guided stereotactic radiosurgery (IG-SRS) may provide a more effective means of managing these lesions. Methods and Materials: Patients with pathologically proven high-grade sarcoma metastatic to the spine treated with HF and SF IG-SRS were included. LC and overall survival (OS) were analyzed by the use of Kaplan-Meier statistics. Univariate and multivariate analyses were performed by the use of Cox regression with competing-risks analysis; all confidence intervals are 95%. Toxicities were assessed according to Common Terminology Criteria for Adverse Events, version 4.0. Results: From May 2005 to November 11, 2012, 88 patients with 120 discrete metastases received HF (3-6 fractions; median dose, 28.5 Gy; n=52, 43.3%) or SF IG-SRS (median dose, 24 Gy; n=68, 56.7%). The median follow-up time was 12.3 months. At 12 months, LC was 87.9% (confidence interval [CI], 81.3%-94.5%), OS was 60.6% (CI, 49.6%-71.6%), and median survival was 16.9 months. SF IG-SRS demonstrated superior LC to HF IG-SRS (12-month LC of 90.8% [CI, 83%-98.6%] vs 84.1% [CI, 72.9%-95.3%] P=.007) and retained significance on multivariate analysis (P=.030, hazard ratio 0.345; CI, 0.132-0.901]. Treatment was well tolerated, with 1% acute grade 3 toxicity, 4.5% chronic grade 3 toxicity, and no grade >3 toxicities. Conclusions: In the largest series of metastatic sarcoma to the spine to date, IG-SRS provides excellent LC in the setting of an aggressive disease with low radiation sensitivity and poor prognosis. Single-fraction IG-SRS is associated with the highest rates of LC with minimal toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of binary Coulomb collisions on nonlinear stimulated Raman backscatter in the kinetic regime

The influence of binary Coulomb collisions on trapped particle nonlinearities related to stimulated Raman scatter (SRS) in a single laser speckle is examined using one-dimensional particle-in-cell simulations. Binary Coulomb collisions are incorporated using a numerical particle-pairing algorithm that reproduces a collision integral of the Landau form. The onset of nonlinearly enhanced levels of SRS reflectivity is shown to coincide with electron trapping in the daughter plasma wave and is sensitive to the collisional scattering rate. Relaxation of trapping-induced perturbations to the electron velocity distribution via collisional velocity space diffusion is predicted to have the largest effect on the onset of SRS when the amplitude of the daughter plasma wave is smallest, and trapping-induced perturbations to the electron velocity distribution function are also small. In the absence of higher dimensional detrapping mechanisms (e.g., electron side-loss), it is shown that the onset threshold for enhanced SRS reflectivity is determined predominantly by the parallel diffusion of trapped electrons scattering from bulk thermal electrons, and that for the conditions studied here, the contribution to detrapping from perpendicular diffusion is non-negligible. Additionally, inverse bremsstrahlung heating of the bulk electrons is shown to shift the daughter plasma wave spectrum upward along the Stoke's resonance to larger wave frequency and smaller wave number, changing the linear parametric coupling conditions to SRS backscatter as a function of time. The reduction in SRS reflectivity from binary Coulomb collisions is greatest for laser intensities near the collisionless onset threshold, ulimately leading to an increase in the onset threshold laser intensity for enhanced SRS reflectivity in the kinetic regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Realisation of four-wave mixing phase matching for frequency components at intracavity stimulated Raman scattering in a calcite crystal

The possibilities of implementing four-wave mixing (FWM) phase matching at stimulated Raman scattering (SRS) in a birefringent SRS-active crystal placed in a cavity with highly reflecting mirrors have been theoretically and experimentally investigated. Phase-matching angles providing conditions for five types of phase matching are determined for a calcite crystal. These types are characterised by different combinations of polarisation directions for the interacting waves and ensure FWM generation of either an anti-Stokes wave or the second Stokes SRS component. In agreement with the calculation results, low-threshold generation of the second Stokes SRS component with a wavelength 0.602 {mu}m was observed at angles of incidence on a calcite crystal of 4.8 Degree-Sign and 18.2 Degree-Sign , under SRS pumping at a wavelength of 0.532 {mu}m. This generation is due to the FWM coupling of the first and second Stokes SRS components with the SRS-pump wave. (nonlinear optical phenomena)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MO-FG-303-03: Demonstration of Universal Knowledge-Based 3D Dose Prediction

Purpose: To demonstrate a knowledge-based 3D dose prediction methodology that can accurately predict achievable radiotherapy distributions. Methods: Using previously treated plans as input, an artificial neural network (ANN) was trained to predict 3D dose distributions based on 14 patient-specific anatomical parameters including the distance (r) to planning target volume (PTV) boundary, organ-at-risk (OAR) boundary distances, and angular position ( θ,φ). 23 prostate and 49 stereotactic radiosurgery (SRS) cases with ≥1 nearby OARs were studied. All were planned with volumetric-modulated arc therapy (VMAT) to prescription doses of 81Gy for prostate and 12–30Gy for SRS. Site-specific ANNs were trained using all prostate 23 plans and using a 24 randomly-selected subset for the SRS model. The remaining 25 SRS plans were used to validate the model. To quantify predictive accuracy, the dose difference between the clinical plan and prediction were calculated on a voxel-by-voxel basis δD(r,θ,φ)=Dclin(r,θ,φ)-Dpred(r, θ,φ). Grouping voxels by boundary distance, the mean <δ Dr>=(1/N)Σ -θ,φ D(r,θ,φ) and inter-quartile range (IQR) quantified the accuracy of this method for deriving DVH estimations. The standard deviation (σ) of δ D quantified the 3D dose prediction error on a voxel-by-voxel basis. Results: The ANNs were highly accurate in predictive ability for both prostate and SRS plans. For prostate, <δDr> ranged from −0.8% to +0.6% (max IQR=3.8%) over r=0–32mm, while 3D dose prediction accuracy averaged from σ=5–8% across the same range. For SRS, from r=0–34mm the training set <δDr> ranged from −3.7% to +1.5% (max IQR=4.4%) while the validation set <δDr> ranged from −2.2% to +5.8% (max IQR=5.3%). 3D dose prediction accuracy averaged σ=2.5% for the training set and σ=4.0% over the same interval. Conclusion: The study demonstrates this technique’s ability to predict achievable 3D dose distributions for VMAT SRS and prostate. Future investigations will attempt to separate and quantify modeling error and plan quality variations in the statistical noise. Research funding support from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Investigating ion recombination effects in a liquid-filled ionization chamber array used for IMRT QA measurements

Purpose: PTW’s Octavius 1000 SRS array performs IMRT quality assurance (QA) measurements with liquid-filled ionization chambers (LICs) to allow closer detector spacing and higher resolution, compared to air-filled QA devices. However, reduced ion mobility in LICs relative to air leads to increased ion recombination effects and reduced collection efficiencies that are dependent on Linac pulse frequency and pulse dose. These pulse parameters are variable during an IMRT delivery, which affects QA results. In this study, (1) 1000 SRS collection efficiencies were measured as a function of pulse frequency and pulse dose, (2) two methods were developed to correct changes in collection efficiencies during IMRT QA measurements, and the effects of these corrections on QA pass rates were compared. Methods: To obtain collection efficiencies, the OCTAVIUS 1000 SRS was used to measure open fields of varying pulse frequency, pulse dose, and beam energy with results normalized to air-filled chamber measurements. Changes in ratios of 1000 SRS to chamber measured dose were attributed to changing collection efficiencies, which were then correlated to pulse parameters using regression analysis. The usefulness of the derived corrections was then evaluated using 6 MV and 10FFF SBRT RapidArc plans delivered to the OCTAVIUS 4D system using a TrueBeam (Varian Medical Systems) linear accelerator equipped with a high definition multileaf collimator. For the first correction, MATLAB software was developed that calculates pulse frequency and pulse dose for each detector, using measurement and DICOM RT Plan files. Pulse information is converted to collection efficiency, and measurements are corrected by multiplying detector dose by ratios of calibration to measured collection efficiencies. For the second correction the MU/min in the daily 1000 SRS calibration was chosen to match the average MU/min of the volumetric modulated arc therapy plan. Effects of the two corrections on QA results were examined by performing 3D gamma analysis comparing predicted to measured dose, with and without corrections. Results: Collection efficiencies correlated linearly to pulse dose, while correlations with pulse frequency were less defined, generally increasing as pulse frequency decreased. After complex MATLAB corrections, average 3D gamma pass rates improved by [0.07%,0.40%,1.17%] for 6 MV and [0.29%,1.40%,4.57%] for 10FFF using [3%/3 mm,2%/2 mm,1%/1 mm] criteria. Maximum changes in gamma pass rates were [0.43%,1.63%,3.05%] for 6 MV and [1.00%,4.80%,11.2%] for 10FFF using [3%/3 mm,2%/2 mm,1%/1 mm] criteria. On average, pass rates of simple daily calibration corrections were within 1% of complex MATLAB corrections. Conclusions: OCTAVIUS 1000 SRS ion recombination effects have little effect on 6 MV measurements. However, the effect could potentially be clinically significant for higher pulse dose unflattened beams when using tighter gamma tolerances, especially when small aperture sizes are used, as is common for SRS/SBRT. In addition, ion recombination effects are strongly correlated to changing MU/min, therefore MU/min used in daily 1000 SRS calibrations should be matched to the expected average MU/min of the IMRT plan.

60 APPLIED LIFE SCIENCES↗

Probabilistic Assessment of Damage from Same Shock Response Spectra due to Variations in Damping

Interpretation of field data from shock tests and subsequent assessment of product safety margins via laboratory testing are based on the shock response spectra (SRS). The SRS capture how a single degree of freedom (SDOF) structure responds to the shock at differing frequencies and, therefore, no longer contain the duration or other temporal parameters pertaining to the shock. A single duration can often be included in the technical specification or in the recreation of acceleration vs. time history from the specified SRS; however, there is little basis for that beyond technical judgment. The loss of such temporal information can result in the recreated SRS being the same while its effect on a system or component can be different. This paper attempts to quantify this deficiency as well as propose a simple method of capturing damping from shock waves that can allow the original waveform to be more accurately reconstructed from the SRS. In this study the decay rate associated with various frequencies that comprise the overall shock was varied. This variation in the decay rate leads to a variation in the acceleration vs. time history, which can be correlated to a “Damage Index” that captures the fatigue damage imparted to the object under shock. Several waveforms that have the same SRS but varying rates of decay for either high- or low-frequency components of the shock were investigated. The resulting variation in stress cycles and Damage Index is discussed in the context of the lognormal distribution of fatigue failure data. It is proposed that, along with the SRS, the decay rate is also captured to minimize the discrepancy between field data and representative laboratory tests.

36 MATERIALS SCIENCE↗

The Natural Enrichment of Stable Cesium in Weathered Micaceous Materials and Its Implications for 137Cs Sorption.

In this exploratory project, we are testing two interrelated hypotheses about the sorption of Cs within weathered micaceous materials in subsurface regolith materials from the Savannah River Site (SRS) located on the Atlantic Coastal Plain: 1) that stable cesium has become significantly enriched relative to potassium in subsurface micaceous particles as a result of chemical weathering processes; and 2) that the Cs so present is sufficient to be a major factor determining the ability of the subsurface materials to take up and hold 137 Cs. To test these hypotheses, we collected by hand augur soil samples corresponding to soils representative at the SRS: upland regolith (Fuquay series); soils formed on Tobacco Road Sandstone; and, soils formed on Quaternary Alluvium. From our data, the quantification of the amounts of stable cesium concentrated in various sites within 2:1 phyllosilicates by natural processes is highly relevant toward understanding the future sorption of 137 Cs by the mica, illite, vermiculite, and hydroxyl interstratified vermiculite (HIV) phases present in the subsurface at and in proximity to SRS. Studying sorption and fixation of Cs in these micaceous phases interlayers potentially leads to increased knowledge to the extent that stable Cs resists exchange with ion exchange cations (Mg, NH4, or even alkyl ammonium compounds) and to the extent that Cs can become fixed over the long term. Such knowledge will help in the development of 137 Cs remediation strategies for the long-term, which is a critical aspect of the SBR goals. We characterized the mineralogy, K-Ar ages of the soil and soil clay fractions (before and after acid treatment), and alkali element chemistry (K, Rb, Cs) of the clay fractions of soils collected from these three different types of soils. The clay fractions of the Fuquay soils are composed of kaolinite, and hydroxy interstratified vermiculite (HIV). Kaolinite, HIV, quartz, gibbsite and illite are found in the quaternary soils. Leach experiments using 10% nitric acid and 50% nitric acid were performed on 62 mesh fractions to show the amounts of Cs and Rb relative to K (Cs/K, Rb/K) that are exchangeable in these soils compared to Coastal Plain micas and upper continental crust. The Cs/K and Rb/K of the leachates are considerably higher relative to both upper continental crust and relative to weathered micas found in Georgia Coast Plain sediments. The K-Ar ages of the clay fractions of five different SRS soil series were ca. 320 Ma. After leaching with nitric acid, the ages of the soil clay fractions were approximately the same as the unleached soil clays. Based on the similarity of these ages to the ages of Coastal Plain micas, the K and Ar remaining after treatment is believed to be enclosed in a relect mica in the HIV phases in the soils. The HIV is likely a mica-HIV intergrade. Based on these data, stable cesium has become significantly enriched relative to potassium in subsurface micaceous particles as a result of chemical weathering processes in the SRS Fuquay soils studied thus far. Our data permit the interpretation describing the sorption of Cs and Rb in an apex site or in a hard to reach hard-to-exchange sorption site during pedogenesis. In terms of testing the second hypothesis, our work is ongoing and we report some preliminary data on Cs-137 and Rb-85 exchange experiments on select SRS Fuquay soils (-2 mm). Our isotopic equilibration experiments using Cs and Rb isotopes in separate exchange experiments show only small amounts of Cs and Rb in the original sample is exchangeable isotopically for a period of a few weeks in acidified conditions. The isotope exchange experiments provide support for our interpretation that pedogenically accumulated Cs (and Rb) occupy sites that are unavailable to exchange or exchange slowly in acid conditions corresponding to present conditions in SRS soils. In more basic solutions, greater exchange isotopic exchange is noted and suggests an expansion of interlayer sites thereby permitting more isotopic exchange of Cs and Rb.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Probabilistic Hazard Assessment for Tornadoes, Straight-line Wind, and Extreme Precipitation at the Savannah River Site

Recent data sets for three meteorological phenomena with the potential to inflict damage on SRS facilities - tornadoes, straight winds, and heavy precipitation - are analyzed using appropriate statistical techniques to estimate occurrence probabilities for these events in the future. Summaries of the results for DOE-mandated return periods and comparisons to similar calculations performed in 1998 by Weber, et al., are given. Using tornado statistics for the states of Georgia and South Carolina, we calculated the probability per year of any location within a 2⁰ square area surrounding SRS being struck by a tornado (the ‘strike’ probability) and the probability that any point will experience winds above set thresholds. The strike probability was calculated to be 1.15E-3 (1 chance in 870) per year and wind speeds for DOE mandated return periods of 50,000 years, 125,000 years, and 1E+7 years (USDOE, 2012) were estimated to be 136 mph, 151 mph and 221 mph, respectively. In 1998 the strike probability for SRS was estimated to be 3.53 E-4 and the return period wind speeds were 148 mph every 50,000 years and 180 mph every 125,000 years. A 1E+7 year tornado wind speed was not calculated in 1998; however a 3E+6 year wind speed was 260 mph. The lower wind speeds resulting from this most recent analysis are largely due to new data since 1998, and to a lesser degree differences in the models used. By contrast, default tornado wind speeds taken from ANSI/ANS-2.3-2011 are somewhat higher: 161 mph for return periods of 50,000 years, 173 mph every 125,000 years, and 230 mph every 1E+7 years (ANS, 2011). Although the ANS model and the SRS models are very similar, the region defined in ANS 2.3 that encompasses the SRS also includes areas of the Great Plains and lower Midwest, regions with much higher occurrence frequencies of strong tornadoes. The SRS straight wind values associated with various return periods were calculated by fitting existing wind data to a Gumbel distribution, and extrapolating the values for any return period from the tail of that function. For the DOE mandated return periods, we expect straight winds of 123 mph every 2500 years, and 132mph every 6250 years at any point within the SRS. These values are similar to those from the W98 report (which also used the Gumbel distribution for wind speeds) which gave wind speeds of 115mph and 122 mph for return periods of 2500 years and 6250 years, respectively. For extreme precipitation accumulation periods, we compared the fits of three different theoretical extreme-value distributions, and in the end decided to maintain the use of the Gumbel distribution for each period. The DOE mandated 6-hr accumulated rainfall for return periods of 2500 years and 6250 years was estimated as 7.8 inches and 8.4 inches, respectively. For the 24-hr rainfall return periods of 10,000 years and 25,000 years, total rainfall estimates were 10.4 inches and 11.1 inches, respectively. These values are substantially lower than comparable values provided in the W98 report. This is largely a consequence of the W98 use of a different extreme value distribution with its corresponding higher extreme probabilities.

54 ENVIRONMENTAL SCIENCES↗

Wildflowers of the Savannah River Site

This guidebook is a resource to help field personnel (nonbotanists) identify plants on the Savannah River Site (SRS) premises. Although not a complete flora guide, this publication contains information about 123 plant species found on the SRS. Plants are listed by their common names and arranged by the color of the flower. The SRS supports a diverse array of plant communities. Land use history, the establishment of the SRS, and current land management practices have shaped the flora presently found on the SRS. Located south of Aiken, SC, SRS spans 198,344 acres with land covering Aiken, Allendale, and Barnwell Counties. Situated on the Upper Coastal Plain and Sandhills physiographic provinces, the SRS has more than 50 distinct soil types. The topography is rolling to flat with elevation ranges from 50 to 400 feet above sea level.

60 APPLIED LIFE SCIENCES↗

Determining Cs-137 Background Body Burdens for Wild Pigs at Savannah River Site

In Gaines and Novak, an effective method for determining the background 137 Cs body burden for the white-tailed deer population on the SRS was developed, using data collected during public hunts combined with gamma overflight data to determine the areas contaminated by site activities. However, a background 137 Cs body burden for the wild pigs present on the SRS has not been developed to date. In this work, we applied the Gaines and Novak methods to determine the 137 Cs background concentration in wild pigs. The determination of a site-specific home range for wild pigs on SRS with establishing background hunt compartments for calculating the background body burdens of 137 Cs resulted in an upper bound concentration in wild pigs on SRS of 1.97 pCi/g. This value bounds 95% of the possible 137 Cs contamination value for wild pigs from the background compartments with 95% confidence. Therefore, it is recommended that 1.97 pCi/g be used in the SRS Hunter Dose Tracking System as the background 137 Cs concentration for wild pigs on SRS. This concentration should be decay corrected from the year 2014. It is also recommended that this assessment of background concentrations in SRS wild pigs (and whitetailed deer) be performed at least every five years.

59 BASIC BIOLOGICAL SCIENCES↗

Probabilistic Hazard Assessment for Tornadoes, Straight-Line Wind, and Extreme Precipitation at the Savannah River Site

Recent data sets for three meteorological phenomena with the potential to inflict damage on SRS facilities – tornadoes, straight-line winds, and heavy precipitation – are analyzed using appropriate statistical techniques to estimate the occurrence probabilities for these events in the future. Summaries of the results for DOE-mandated return periods and comparisons to similar calculations performed in 2013 by Werth et al. (W2013) are given. Using tornado statistics for i) the combined states of Georgia and South Carolina, and ii) a 2⁰ square area surrounding SRS, we calculated the probability per year of any location at SRS being struck by a tornado (the ‘strike’ probability) and the probability that any point will experience winds above set thresholds. The strike probability was calculated to be 7.04E-4 (1 chance in 1420) per year and tornadic wind speeds for DOE mandated return periods of 50,000 years (corresponding to wind design category 3 (WDC-3), and 125,000 years (meeting WDC-4) (USDOE, 2016) were estimated to be 132 mph and 147 mph, respectively. By contrast, default tornado wind speeds taken from ANSI/ANS-2.3-2011 are somewhat higher: 161 mph for return periods of 50,000 years and 173 mph every 125,000 years (ANS, 2011). Although the ANS and the SRS evaluation used the same basic model (Ramsdell and Rishel, 2007), the region defined in ANS 2.3 that encompasses the SRS also includes areas of the Great Plains and lower Midwest, regions with much higher occurrence frequencies of strong tornadoes. The SRS straight-line wind values associated with various return periods were calculated by fitting existing wind data to a GEV1 distribution and extrapolating the values for any return period from the tail of that function. For the DOE mandated return periods, we expect straight-line winds of 117 mph every 2500 years (the required WDC-3 standard) and 125 mph every 6250 years (WDC-4) at any point within the SRS. These values are similar to those from the ANS-2.3-2011 report, which has wind speeds of 125mph and 133 mph for return periods of 2500 years and 6250 years, respectively. For extreme precipitation, we compared the fits of two different theoretical extreme-value distributions and applied the one that fit the data best for each of several accumulation periods. The DOE mandated 6-hr accumulated rainfall for return periods of 10,000 years (corresponding to precipitation design category 3 (PDC-3) and 25,000 years (PDC-4) were estimated as 9.1 inches and 10.1 inches, respectively. For the 24-hr rainfall return periods of 10,000 years and 25,000 years, total rainfall estimates were 12.02 inches and 13.17 inches, respectively, higher than comparable values provided in the W2013 report.

54 ENVIRONMENTAL SCIENCES↗

LAND AND WATER USE CHARACTERISTICS AND HUMAN HEALTH INPUT PARAMETERS FOR USE IN ENVIRONMENTAL DOSIMETRY AND RISK ASSESSMENTS AT THE SAVANNAH RIVER SITE

Operations at the Savannah River Site (SRS) result in releases of small amounts of radioactive materials to the atmosphere and to the Savannah River. For regulatory compliance purposes, potential offsite radiological doses are estimated annually using computer models that follow U.S. Nuclear Regulatory Commission (NRC) Regulatory Guides. Within the regulatory guides, default values are provided for many of the dose model parameters but the use of site-specific values by the applicant is encouraged. A detailed survey of land and water use parameters was conducted in 1991 and is being updated here. These parameters include local characteristics of meat, milk and vegetable production; river recreational activities; and meat, milk and vegetable consumption rates as well as other human usage parameters required in the SRS dosimetry models. In addition, the preferred elemental bioaccumulation factors and transfer factors to be used in human health exposure calculations at SRS are documented. Based on comparisons to the 2009 SRS environmental compliance doses, the following effects are expected in future SRS compliance dose calculations: (1) Aquatic all-pathway maximally exposed individual doses may go up about 10 percent due to changes in the aquatic bioaccumulation factors; (2) Aquatic all-pathway collective doses may go up about 5 percent due to changes in the aquatic bioaccumulation factors that offset the reduction in average individual water consumption rates; (3) Irrigation pathway doses to the maximally exposed individual may go up about 40 percent due to increases in the element-specific transfer factors; (4) Irrigation pathway collective doses may go down about 50 percent due to changes in food productivity and production within the 50-mile radius of SRS; (5) Air pathway doses to the maximally exposed individual may go down about 10 percent due to the changes in food productivity in the SRS area and to the changes in element-specific transfer factors; and (6) Air pathway collective doses may go down about 30 percent mainly due to the decrease in the inhalation rate assumed for the average individual.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of variables upon pyrotechnically induced shock response spectra

Throughout the aerospace industry, large variations of 50 percent (6 dB) or more are continually noted for linear shaped charge (LSC) generated shock response spectra (SRS) from flight data (from the exact same location on different flights) and from plate tests (side by side measurements on the same test). A research program was developed to investigate causes of these large SRS variations. A series of ball drop calibration tests to verify calibration of accelerometers and a series of plate tests to investigate charge and assembly variables were performed. The resulting data were analyzed to determine if and to what degree manufacturing and assembly variables, distance from the shock source, data acquisition instrumentation, and shock energy propagation affect the SRS. LSC variables consisted of coreload, standoff, and apex angle. The assembly variable was the torque on the LSC holder. Other variables were distance from source of accelerometers, accelerometer mounting methods, and joint effects. Results indicated that LSC variables did not affect SRS as long as the plate was severed. Accelerometers mounted on mounting blocks showed significantly lower levels above 5000 Hz. Lap joints did not affect SRS levels. The test plate was mounted in an almost free-free state; therefore, distance from the source did not affect the SRS. Several varieties and brands of accelerometers were used, and all but one demonstrated very large variations in SRS.

Smith, J. L.↗