Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Swift: Status and Future Developments

We describe the current status of the Swift mission: its performance metrics and the state of health of the instruments and the mission; and in the future new functions, enhancements, and efforts to improve the quality of the science output and its productivity.

79 ASTRONOMY AND ASTROPHYSICS↗

How Real Detector Thresholds Create False Standard Candles

GRB satellites are relatively inefficient detectors of dim hard bursts. For example, given two bursts of identical peak luminosity near the detection threshold, a dim soft burst will be preferentially detected over a dim hard burst. This means that a high E{sub peak} burst will need a higher peak luminosity to be detected than a low E{sub peak} GRB. This purely detector-created attribute will appear as a correlation between E{sub peak} and luminosity, and should not be interpreted as a real standard candle effect. This result derives from Monte Carlo simulations utilizing a wide range of initial GRB spectra, and retriggering to create a final ''detected'' sample. In sum, E{sub peak} is not a good standard candle, and its appearance as such in seeming correlations such as the Amati and other L{sub iso} vs. E{sub peak} relations is likely a ghost of real energy-related detection thresholds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the Possibility of Screening High-z GRBs based on BAT Prompt Emission Properties

Being able to quickly select among gamma-ray bursts (GRBs) seen by the Swift satellite those which are high-z candidates would give ground-based observers a better chance to determine a redshift for such distant GRBs. Information about these high-z GRBs is important in helping to resolve questions about the early universe such as the formation rate of high-z GRBs, the re-ionization period of the universe, the metallicity of the early universe, and the Hubble expansion. Initially using a sample of 51 GRBs with previously measured redshifts, we have developed high-z screening criteria employing the GRB spectral as well as temporal characteristics of the prompt emission from the Burst Alert Telescope (BAT) on Swift. Now that the sample has increased to 81 GRBs, we have revisited the screening criteria and our methodology. Our updated high-z screening criteria are presented in this paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Using GRB 080723B to cross-calibrate Fermi/GBM and INTEGRAL

On July 23, 2008 GRB 080723B, a bright GRB lasting about 105 s was detected by the INTEGRAL burst alert system. This burst was also detected by the Fermi Gamma-ray burst monitor. At this time no Fermi/GBM GCN notices were distributed to the public because Fermi was still in commissioning phase. The simultaneous detection of a bright GRB by both satellites gives us the opportunity to cross-calibrate the GBM with the already well-calibrated instruments on-board INTEGRAL, the Spectrometer SPI and the Imager IBIS. Time-resolved spectroscopy of this long and structured GRB is of special importance because Fermi was slewing during the GRB was still ongoing. In this paper we present a first and still preliminary analysis of the GBM spectra and compare them to those obtained by SPI for the same selection of time intervals. A more accurate cross-calibration will be forthcoming when the improved in-flight calibration of GBM is available and the corresponding data and responses can be reprocessed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Light and Effective Wide Field Monitor for Gamma Ray Bursts and Transient Sources

We present here a concept for a light and low-power wide field monitor working in the X-ray range, suitable for simultaneous imaging of large portions of the sky and GRB localizations. Our concept evolves from and improves on the design of the 5-kg SuperAGILE experiment, flying on the AGILE mission and currently delivering arcmin-localizations of GRBs at a rate of about 1/month. Similar to SuperAGILE, our concept is based on position sensitive silicon detectors equipped with one-dimensional coded masks. Different options are available for the detector, whose properties, combined with the scientific requirements, drive the design of the experiment. Our approach is based on a modular detector. The experiment design can then be tailored to specific scientific goals of the experiment or the mission (e.g., to cite GRBs only: the brightest GRBs/XRFs on a large field of view - FoV, or many low-fluence GRBs/XRFs on a smaller FoV, or the low energy spectrum of the prompt event, or the detection of high-z GRBs). In this paper we describe the concept, the main detector properties and outline some possible experiment configurations, with examples of their expected performance. Different experiment configurations in terms of area, FoV, angular resolution may be designed starting from the same detectors. Instead, the band-pass is mostly related to the detector properties. A key point of our project is the high degree of readiness of the detectors that are at production level and may be immediately proposed for a future experiment onboard missions with high readiness requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MIREDO Facility in Novi Sad

The MIREDO (Muon Induced Rare Event Dynamic Observatory) spectrometer system will be mainly devoted for the study of cosmic muon induced nuclear reactions. The system will be developed around the 100% nominal efficiency ultra low-background HPGe spectrometer. Our previous detection system enabled only the detection of secondary muon induced events mostly from the interaction of cosmic muons with the shielding materials. The improved geometry of the MIREDO scintillation detection system will enable the direct measurement of the cross section of the muon induced reactions with the sample material.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The XENON Dark Matter Project: Status of the XENON100 Phase

The XENON100 experiment aims to detect cold dark matter particles via their elastic collisions with xenon nuclei. An ultra-low background, two-phase time projection chamber with a total of 170 kg of xenon (65 kg in the target region and 105 kg in the active veto) has been installed at the Gran Sasso Underground Laboratory and is currently in commissioning phase. We review the design and performance of the detector and its associated systems, present status, preliminary calibration results, background prediction and projected sensitivity. With a 6000 kg-day background-free exposure, XENON100 will reach a sensitivity of spin-independent WIMP-nucleon cross section of 2x10{sup -45} cm{sup 2} by the end of 2009. We also discuss our plan to upgrade the XENON100 experiment to improve the sensitivity by another order of magnitude by 2012.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The XENON10 WIMP Direct Detection Search at the Gran Sasso Underground Laboratory

The direct detection search for WIMPs with the XENON10 detector has produced among the best results in the field to date. The detector is a dual-phase liquid xenon time projection chamber, capable of 3-D position reconstruction and nuclear recoil discrimination. We summarize 58.6 live-days of WIMP search data collected at the Gran Sasso Underground Laboratory (LNGS) in Italy. With this data we have been able to set stringent upper limits on the spin-dependent and spin-independent WIMP scattering cross sections, in addition to a lower limit of 2.2 TeV/c{sup 2} on the mass of the heavy Majorana neutrino.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ZEPLIN-II limits on WIMP-nucelon interactions

ZEPLIN II is a two-phase xenon detector designed to detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs). Following the first 31-day underground run in Boulby Mine, UK, the collaboration published dark matter limits in January 2007; the first such limits using two-phase xenon technology. We outline the key detector design, performance and results here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ZEPLIN-III

The direct detection of weakly interacting massive particles by a terrestrial device is widely recognised as a definitive proof of the cold dark matter hypothesis and a robust test of physics beyond the Standard Model. ZEPLIN-III is one of the latest generation of instruments specifically designed for this objective. This instrument has developed the two-phase liquid-gas xenon technology, and features high-field extraction, open plan geometry and low background components. Here we present the status of the project as of February 2008.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MOON for neutrino-less {beta}{beta} decays and {beta}{beta} nuclear matrix elements

The MOON project aims at spectroscopic 0v{beta}{beta} studies with the v-mass sensitivity of 100-30 meV by measuring two beta rays from {sup 100}Mo and/or {sup 82}Se. The detector is a compact super-module of multi-layer PL scintillator plates. R and D works made by the pro to-type MOON-1 and the small PL plate show the possible energy resolution of around {sigma}{approx}2.2%, as required for the mass sensitivity. Nuclear matrix elements M{sup 2v} for 2v{beta}{beta} are shown to be given by the sum {sigma}{sub L}M{sub k} of the 2v{beta}{beta} matrix elements M{sub k} through intermediate quasi-particle states in the Fermi-surface, where Mi is obtained experimentally by using the GT(J{sup {pi}} = 1{sup +}) matrix elements of M{sub i}(k) and M{sub f}(k) for the successive single-{beta} transitions through the k-th intermediate state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chemical vapor deposition diamond based multilayered radiation detector: Physical analysis of detection properties

Recently, solid state photovoltaic Schottky diodes, able to detect ionizing radiation, in particular, x-ray and ultraviolet radiation, have been developed at the University of Rome 'Tor Vergata'. We report on a physical and electrical properties analysis of the device and a detailed study of its detection capabilities as determined by its electrical properties. The design of the device is based on a metal/nominally intrinsic/p-type diamond layered structure obtained by microwave plasma chemical vapor deposition of homoepitaxial single crystal diamond followed by thermal evaporation of a metallic contact. The device can operate in an unbiased mode by using the built-in potential arising from the electrode-diamond junction. We compare the expected response of the device to photons of various energies calculated through Monte Carlo simulation with experimental data collected in a well controlled experimental setup i.e., monochromatic high flux x-ray beams from 6 to 20 keV, available at the Diamond Light Source synchrotron in Harwell (U.K.).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tests of a C{sub 6}D{sub 6} Deuterated Scintillator Array and Measurements of (d, n) Cross Sections

A deuterated liquid-scintillator neutron detector array (C{sub 6}D{sub 6}) has been developed and tested in-beam, which permits useable neutron energy measurements without need of time-of-flight (ToF), while still providing excellent n/gamma and muon discrimination. A similar detector of the same size based on (C{sub 6}H{sub 6}) also was tested for comparison purposes. The exothermic reactions {sup 3}H(d,n){sup 4}He and {sup 2}H(d,n){sup 3}He were used to deduce neutron spectra from the specially designed C{sub 6}D{sub 6} liquid scintillators. Major features of the detector and its response to high-energy neutrons and gammas from a {sup 13}C(d,n){sup 14}N experiment are presented. Preliminary cross sections for the ground and excited states of {sup 14}N have been measured using the detector array. The array should be well-suited for study of many reactions involving neutrons, including exothermic (d, n) reactions with radioactive ion beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of radiation detectors

Several types of detectors are reviewed. The principle of operation and properties of ionization and wire chambers, semiconductor detectors, scintillation detectors are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute charge calibration of scintillating screens for relativistic electron detection

We report on new charge calibrations and linearity tests with high-dynamic range for eight different scintillating screens typically used for the detection of relativistic electrons from laser-plasma based acceleration schemes. The absolute charge calibration was done with picosecond electron bunches at the ELBE linear accelerator in Dresden. The lower detection limit in our setup for the most sensitive scintillating screen (KODAK Biomax MS) was 10 fC/mm{sup 2}. The screens showed a linear photon-to-charge dependency over several orders of magnitude. An onset of saturation effects starting around 10-100 pC/mm{sup 2} was found for some of the screens. Additionally, a constant light source was employed as a luminosity reference to simplify the transfer of a one-time absolute calibration to different experimental setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark matter signals in deflected mirage mediation

We investigate the parameter space of a specific class of model within the deflected mirage mediation (DMM) scenario. We look at neutralino properties and compute the thermal relic density as well as interaction rates with xenon direct detection experiments. We find that there are portions of the parameter space which are in line with the current WMAP constraints. Further we find that none of the investigated parameter space is in conflict with current bounds from the Xenon10 experiment and that future large-scale liquid xenon experiments will probe a large portion of the model space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hunting the Dark Matter with DEAP/CLEAN

The potential of the DEAP/CLEAN program for direct Dark Matter detection to test various dark matter models is illustrated. The scintillation pulse of a noble liquid like Argon or Neon has two well distinguished time constants allowing a very reliable correlation between pulse shape and type of event. This pulse shape discrimination already provides the power of rejecting a background10{sup 8}-10{sup 9} times larger than the signal. MiniCLEAN, a 500 kg LAr detector, is currently under construction, and a 3.6 ton detector, DEAP-3600, under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid Scintillation Detectors for High Energy Neutrinos

Large open volume (not segmented) liquid scintillation detectors have been generally dedicated to low energy neutrino measurements, in the MeV energy region. We describe the potential employment of large detectors (>1 kiloton) for studies of higher energy neutrino interactions, such as cosmic rays and long-baseline experiments. When considering the physics potential of new large instruments the possibility of doing useful measurements with higher energy neutrino interactions has been overlooked. Here we take into account Fermat's principle, which states that the first light to reach each PMT will follow the shortest path between that PMT and the point of origin. We describe the geometry of this process, and the resulting wavefront, which we are calling the 'Fermat surface', and discuss methods of using this surface to extract directional track information and particle identification. This capability may be demonstrated in the new long-baseline neutrino beam from Jaeri accelerator to the KamLAND detector in Japan. Other exciting applications include the use of Hanohano as a movable long-baseline detector in this same beam, and LENA in Europe for future long-baseline neutrino beams from CERN. Also, this methodology opens up the question as to whether a large liquid scintillator detector should be given consideration for use in a future long-baseline experiment from Fermilab to the DUSEL underground laboratory at Homestake.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗