Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Collimated electron beam accelerated at 12 kV from a Penning discharge

A pulsed electron beam accelerated at 12 kV with a duration of 40 μs per pulse is obtained from a Penning discharge with a hollow anode and two cathodes. The electrons are extracted through a hole in one of the cathodes and focused by a pair of coils. The electron beam has a diameter of a few mm in the cross section, while the beam current reaches peak values of 400 mA, depending on the magnetic field inside the focussing coils. This relatively inexpensive and compact device is suitable for the irradiation of small material samples placed in high vacuum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemical speciation of U, Fe, and Pu in melt glass from nuclear weapons testing

Nuclear weapons testing generates large volumes of glassy materials that influence the transport of dispersed actinides in the environment and may carry information on the composition of the detonated device. We determine the oxidation state of U and Fe (which is known to buffer the oxidation state of actinide elements and to affect the redox state of groundwater) in samples of melt glass collected from three U.S. nuclear weapons tests. For selected samples, we also determine the coordination geometry of U and Fe, and we report the oxidation state of Pu from one melt glass sample. We find significant variations among the melt glass samples and, in particular, find a clear deviation in one sample from the expected buffering effect of Fe(II)/Fe(III) on the oxidation state of uranium. In the first direct measurement of Pu oxidation state in a nuclear test melt glass, we obtain a result consistent with existing literature that proposes Pu is primarily present as Pu(IV) in post-detonation material. In addition, our measurements imply that highly mobile U(VI) may be produced in significant quantities when melt glass is quenched rapidly following a nuclear detonation, though these products may remain immobile in the vitrified matrices. The observed differences in chemical state among the three samples show that redox conditions can vary dramatically across different nuclear test conditions. The local soil composition, associated device materials, and the rate of quenching are all likely to affect the final redox state of the glass. The resulting variations in glass chemistry are significant for understanding and interpreting debris chemistry and the later environmental mobility of dispersed material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A high-stability non-contact dilatometer for low-amplitude temperature-modulated measurements

Temperature modulated thermophysical measurements can deliver valuable insights into the phase transformation behavior of many different materials. While especially for non-metallic systems at low temperatures numerous powerful methods exist, no high-temperature device suitable for modulated measurements of bulk metallic alloy samples is available for routine use. In this work a dilatometer for temperature modulated isothermal and non-isothermal measurements in the temperature range from room temperature to 1300 K is presented. The length measuring system is based on a two-beam Michelson laser interferometer with an incremental resolution of 20 pm. The non-contact measurement principle allows for resolving sinusoidal length change signals with amplitudes in the sub-500 nm range and physically decouples the length measuring system from the temperature modulation and heating control. To demonstrate the low-amplitude capabilities, results for the thermal expansion of nickel for two different modulation frequencies are presented. These results prove that the novel method can be used to routinely resolve length-change signals of metallic samples with temperature amplitudes well below 1 K. This high resolution in combination with the non-contact measurement principle significantly extends the application range of modulated dilatometry towards high-stability phase transformation measurements on complex alloys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal conductivity of MoS 2 monolayers from molecular dynamics simulations

Quantification of lattice thermal conductivity of two-dimensional semiconductors like MoS 2 is necessary for the design of electronic and thermoelectric devices, but direct experimental measurements on free-standing samples is challenging. Molecular dynamics simulations, with appropriate corrections, can provide a reference value for thermal conductivity for these material systems. Here, we construct a new empirical forcefield of the Stillinger-Weber form, parameterized to phonon dispersion relations, lattice constants and elastic moduli and we use it to compute a material-intrinsic thermal conductivity of 38.1 W/m-K at room temperature and estimate a maximum thermal conductivity of 85.4 W/m-K at T = 200 K. We also identify that phonon scattering by the large isotopic mass distribution of Mo and S contributes a significant correction (>45%) to the thermal conductivity at low temperatures.

36 MATERIALS SCIENCE↗

Photoelectric conversion on Earth’s surface via widespread Fe- and Mn-mineral coatings

Sunlight drives photosynthesis and associated biological processes, and also influences inorganic processes that shape Earth’s climate and geochemistry. Bacterial solar-to-chemical energy conversion on this planet evolved to use an intricate intracellular process of phototrophy. However, a natural nonbiological counterpart to phototrophy has yet to be recognized. In this work, we reveal the inherent “phototrophic-like” behavior of vast expanses of natural rock/soil surfaces from deserts, red soils and karst environments, all of which can drive photon-to-electron conversions. Using scanning electron microscopy, transmission electron microscopy, micro-Raman spectroscopy and X-ray absorption spectroscopy, Fe and Mn (oxyhydr)oxide-rich coatings were found in rock varnishes, as were Fe (oxyhydr)oxides on red soil surfaces and minute amounts of Mn oxides on karst rock surfaces. By directly fabricating a photoelectric detection device on the thin section of a rock varnish sample, we have recorded the first in situ photocurrent micromapping of the coatings, which behave as highly sensitive and stable photoelectric systems. Additional measurements of red soil and powder separated from the outermost surface of karst rocks yielded photocurrents that are also sensitive to irradiation. The prominent solar-responsive capability of the phototrophic-like rocks/soils is ascribed to the semiconducting Fe and Mn (oxyhydr)oxide mineral coatings. The native semiconducting Fe/Mn-rich coatings may play a role similar in part to photosynthetic systems and thus provide a distinctive driving force for redox (bio)geochemistry on Earth’s surfaces.

Lu, Anhuai↗

Vacuum System and Modeling for the Materials Plasma Exposure Experiment

Understanding the science of plasma-material interactions (PMI) is essential for the future development of fusion facilities. The design of divertors and first walls for the next generation of long-pulse fusion facilities, such as a Fusion Nuclear Science Facility (FNSF) or a DEMO, requires significant PMI research and development. In order to meet this need, a new linear plasma facility, the Materials Plasma Exposure Experiment (MPEX) is proposed, which will produce divertor relevant plasma conditions for these next generation facilities. The device will be capable of handling low activation irradiated samples and be able to remove and replace samples without breaking vacuum. A Target Exchange Chamber (TEC) which can be disconnected from the high field environment in order to perform in-situ diagnostics is planned for the facility as well. The vacuum system for MPEX must be carefully designed in order to meet the requirements of the different heating systems, and to provide conditions at the target similar to those expected in a divertor. An automated coupling-decoupling (“autocoupler”) system is designed to create a high vacuum seal, and will allow the TEC to be disconnected without breaking vacuum in either the TEC or the primary plasma materials interaction chamber. This autocoupler, which can be actuated remotely in the presence of the high magnetic fields, has been designed and prototyped, and shows robustness in a variety of conditions. The vacuum system has been modeled using a simplified finite element analysis, and indicates that the design goals for the pressures in key regions of the facility are achievable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scanning SQUID study of ferromagnetism and superconductivity in infinite-layer nickelates

Infinite-layer nickelates R 1-x Sr x NiO 2 (R = La, Pr, Nd) are a class of superconductors with structural similarities to cuprates. Although long-range antiferromagnetic order has not been observed for these materials, magnetic effects such as antiferromagnetic spin fluctuations and spin-glass behavior have been reported. Different experiments have drawn different conclusions about whether the pairing symmetry is s or d wave. In this paper, we applied a scanning superconducting quantum interference device (SQUID) to probe the magnetic behavior of film samples of three infinite-layer nickelates (La 0.85 Sr 0.15 NiO 2 , Pr 0.8 Sr 0.2 NiO 2 , and Nd 0.775 Sr 0.225 NiO 2 ) grown on SrTiO 3 (STO), each with a nominal thickness of 20 unit cells. In all three films, we observed a ferromagnetic background. We also measured the magnetic susceptibility above the superconducting critical temperature in Pr 0.8 Sr 0.2 NiO 2 and La 0.85 Sr 0.15 NiO 2 and identified a non-Curie-Weiss dynamic susceptibility. Both magnetic features are likely due to NiO x nanoparticles. We investigated superconductivity in Pr 0.8 Sr 0.2 NiO 2 and Nd 0.775 Sr 0.225 NiO 2 , which exhibited inhomogeneous diamagnetic screening. The superfluid density inferred from the diamagnetic susceptibility in relatively homogeneous regions shows T-linear behavior in both samples. Finally, we observed superconducting vortices in Nd 0.775 Sr 0.225 NiO 2 . We determined a Pearl length of 330 µm for Nd 0.775 Sr 0.225 NiO 2 at 300 mK, both from the strength of the diamagnetism and from the size and shape of the vortices. These results highlight the importance of considering NiO x particles when interpreting experimental results for these films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photon-counting hexagonal pixel array CdTe detector: Spatial resolution characteristics for image-guided interventional applications

Purpose: High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. Methods: A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixel pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. Results: At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Conclusions: Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraining the nuclear spin distribution using improved 197 Au neutron resonance parameters

New neutron transmission data at resonance energies using a 197 Au sample were measured using an early version of the Device for Indirect Capture Experiments on Radionuclides (DICER), which is under development at the Los Alamos Neutron Science Center (LANSCE). These data were combined with previous neutron transmission and capture data in a simultaneous R-matrix analysis to extract improved neutron resonance parameters for this nuclide. As a result, total radiation widths, Γ γ , were obtained for 33 J=1 and 44 J=2 197 Au+n resonances. Γ γ distributions for these two spins states were compared to distributions calculated according to the nuclear statistical model using published nuclear level density (NLD) and photon strength functions (PSF) measured using the Oslo technique. The calculated distributions were found to be narrower and the average values for the two spins states closer together than the data. The calculation can be brought into agreement with the data by substantial modifications to the spin distribution in 198 Au as a function of excitation energy. As far as we know, the spin distribution currently is otherwise poorly constrained. The modified spin distribution changes the shapes of the NLD and PSF extracted using the Oslo technique and so could have broad implications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Engineering at SLAC: Designing and Constructing Experimental Devices for the Stanford Synchrotron Radiation Lightsource (Final Paper)

Thanks to the versatility of the beam lines at SSRL, research there is varied and benefits multiple fields. Each experiment requires a particular set of experiment equipment, which in turns requires its own particular assembly. As such, new engineering challenges arise from each new experiment. My role as an engineering intern has been to help solve these challenges, by designing and assembling experimental devices. My first project was to design a heated sample holder, which will be used to investigate the effect of temperature on a sample's x-ray diffraction pattern. My second project was to help set up an imaging test, which involved designing a cooled grating holder and assembling multiple positioning stages. My third project was designing a 3D-printed pencil holder for the SSRL workstations.

42 ENGINEERING↗

Spectral and Microclimate Measurements in Relation to Gold-Standard Methods Field Campaign Report

Arable is an agricultural data and analytics company offering an Internet of things (IOT)-enabled irrigation management tool, weather station, and crop monitor: the Arable Mark. The device synthesizes both climate and plant data to produce actionable insights on natural resource management, mainly commercial agriculture at any scale. Arable collected 11 months of microclimate and radiometric data at the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) observatory to compare measurements of the Arable Mark to the ARM-SGP gold-standard sensors, and for demonstrating the ease of installation and system value to stakeholders. A member from Arable labs installed the device on January 10, 2018, at the ARM facilities and the site managers were in charge of maintaining the sensors in a clean state until the unit’s removal on January 15, 2019. The sampling was positively uneventful, except for a period during the winter when the device stopped posting data for about one week. The verdict was that the equipment required an external solar panel to stay powered through the shorter days of winter. A solar panel was shipped to the SGP, and the unit came back to full charge to continue sending data for the rest of the sampling period. The main goal of the project is to use the data collected by the Arable Mark and build a model that can establish a close relationship with the current methodologies applied to measure ecosystem response to environmental changes. During the sampling period, our team discovered that there was a drift in some of the meteorological data and also in the radiometry, so all efforts are focused into the development of models that would reduce the errors in the reported values.

Southern Great Plains, evapotranspiration, photosy↗

Evaluation of thermal gradients in longitudinal spin Seebeck effect measurements

In the framework of the longitudinal spin Seebeck effect (LSSE), we developed an experimental setup for the characterization of LSSE devices. This class of device consists in a layered structure formed by a substrate, a ferrimagnetic insulator (YIG) where the spin current is thermally generated, and a paramagnetic metal (Pt) for the detection of the spin current via the inverse spin-Hall effect. In this kind of experiments, the evaluation of a thermal gradient through the thin YIG layer is a crucial point. In this work, we perform an indirect determination of the thermal gradient through the measurement of the heat flux. We developed an experimental setup using Peltier cells that allow us to measure the heat flux through a given sample. In order to test the technique, a standard LSSE device produced at Tohoku University was measured. We find a spin Seebeck S{sub SSE} coefficient of 2.8×10{sup −7} V K{sup −1}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoscale Elemental Mapping of Intact Solid–Liquid Interfaces and Reactive Materials in Energy Devices Enabled by Cryo-FIB/SEM

Many modern energy devices rely on solid–liquid interfaces, highly reactive materials, or both, for their operation and performance. The difficulty of characterizing such materials means these devices often lack high-resolution characterization in an unaltered state. Here, we demonstrate how cryogenic sample preparation and transfer can extend the capabilities of FIB/SEM techniques to solid–liquid interfaces and reactive materials common to energy devices by preserving their integrity through all stages of preparation and characterization. We additionally show how cryo-FIB/SEM paired with energy dispersive X-ray spectroscopy enables nanoscale elemental mapping of cross-sections produced in these materials and discuss strategies to achieve optimal results. Finally, we consider current limitations of the technique and propose future developments that could enhance its capabilities. Our results illustrate that cryo-FIB/SEM will be a useful technique for fields where solid–liquid interfaces or reactive materials play an important role and could, thus far, not be characterized at high resolution.

25 ENERGY STORAGE↗

Adaptive Fault Detection Based on Neural Networks and Multiple Sampling Points for Distribution Networks and Microgrids

Smart networks such as microgrid (MG) and active distribution networks (ADN) have been recently playing an important role in power system operation. The design and implementation of appropriate protection systems for such networks must be addressed, which imposes new technical challenges. This paper presents the implementation and validation aspects of an adaptive fault detection strategy based on neural networks (NNs) and multiple sampling points for ADN and MG. The solution is implemented on an edge device. Artificial NNs are used to derive a data-driven model that uses only local measurements to detect fault states of the network without the need for communication infrastructure. Multiple sampling points are used to derive a data-driven model, which allows the generalization considering the implementation in physical systems. The adaptive fault detector model is implemented on a Jetson Nano system, which is a single-board computer (SBC) with a small Graphic Processing Unit (GPU) intended to run machine learning loads at the edge. The proposed method is tested in a physical, real-life, low-voltage network located at Universidad del Norte, Colombia. This testing network is based on the IEEE-13 Node Test Feeder scaled down to 220 V. The validation in a simulation environment shows the accuracy and dependability above 99.6%, while the real-time tests show the accuracy and dependability of 95.5% and 100%, respectively. Without hard-to-derive parameters, the easy-to-implement embedded model highlights the potential for real-life applications.

42 ENGINEERING↗

Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device

Purpose: Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy of this device for the purpose of mouse brain irradiation. Methods: A mouse head holder was designed for a microCT couch using CAD software and printed in an acrylic based material. Ten mice received half-brain radiation while positioned in the 3D-printed head holder. Animal placement was achieved using on-board image guidance and computerized asymmetric collimators. To evaluate the precision of beam localization for half-brain irradiation, mice were sacrificed approximately 30 min after treatment and brain sections were stained for γ-H2AX, a marker for DNA breaks. The distance and angle of the γ-H2AX radiation beam border to longitudinal fissure were measured on histological samples. Animals were monitored for any possible trauma from the device. Results: Visualization of the radiation beam on ex vivo brain sections with γ-H2AX immunohistochemical staining showed a sharp radiation field within the tissue. Measurements showed a mean irradiation targeting error of 0.14 ± 0.09 mm (standard deviation). Rotation between the beam axis and mouse head was 1.2° ± 1.0° (standard deviation). The immobilization device was easily adjusted to accommodate different sizes of mice. No signs of trauma to the mice were observed from the use of tooth block and ear bars. Conclusions: The authors designed and built a novel 3D-printed mouse head holder with many desired features for accurate and reproducible radiation targeting. The 3D printing technology was found to be practical and economical for producing a small animal imaging and radiation restraint device and allows for customization for study specific needs.

60 APPLIED LIFE SCIENCES↗

Integrated solid-state rapid thermo-cycling system

Techniques, systems, and devices are disclosed for implementing a portable lab system for PCR testing. The portable lab system comprises a thermal cycling device including a first well and a second well to receive samples to be thermally cycled, a thermoelectric cooling (TEC) element coupled to the first well and the second well, and a controller to control operation of the TEC element. The portable lab system further includes an electronic interface including a power interface to supply power to the TEC element and the controller of the thermal cycling device to allow the TEC element to transfer energy from the first well to the second well when current flows through the TEC element in a first direction, and from the second well to the first well when current flows through the TEC element in a second direction, and a data interface to collect data from the controller.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Design Alternatives of Actively Cooled RF Window for MPEX

The Materials Plasma Exposure eXperiment (MPEX) has been designed as a linear plasma divertor simulator in order to address plasma material interaction (PMI) science for next-generation fusion devices. It will have the capability to test neutron irradiated samples with plasma fluxes of greater than 10 24 m -2 s -1 . It is expected to operate steady state for up to 10 6 s to consider PMI affects through reactor end of life. The conceptual design of MPEX was completed in 2019, with preliminary design having begun in 2020. The plasma source for MPEX is a helicon antenna, where the energized helical antenna sits outside of the vacuum in order to minimize impurities in the plasma. It is expected to receive up to 200 kW of continuous power, and so the antenna and the window must be actively cooled. The water-cooled copper antenna has been operated at full power on the Proto-MPEX device (which is a test facility to demonstrate the plasma source and heating systems). The water-cooled window, however, is a novel component that must meet numerous competing requirements. It requires a low dielectric loss to allow the Radio Frequency (RF) power to create the plasma within the vacuum boundary. It must be structurally robust to handle the significant heat flux from the plasma and any heat from dielectric coupling. It must be compatible with the coolant (preferably water). It requires a vacuum seal that minimizes impurities into the plasma and does not compromise the structural integrity of the window. Two window designs have been tested. Results from these tests, where temperatures are measured and heat fluxes inferred from infrared camera data, have been correlated with thermal-structural simulations. When these simulations are extrapolated to the full power steady-state heat fluxes that are expected in MPEX, the designs do not appear to have the necessary structural robustness. This study explores design alternatives for the MPEX helicon antenna window, presents analysis results for several of the alternatives, and shows a viable solution that satisfies the requirements for MPEX operation.

Tipton Jr, Joseph↗